310AAV/310JAV Sizes 045 thru 155 Series A

Similar documents
ama 311AAV/311JAV Sizes 045 thru 155 Series A 4-Way Multipoise Induced Combustion Gas Furnace Form No. PDS 311A.45.3

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

395CAV Sizes 045 thru 155 Series H and J

Product Data. 58DLA/DLX WeatherMaker 8000 Deluxe 4-Way Multipoise Induced-Combustion Gas Furnace. Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58DLA/DLX COMFORT 80 DELUXE 4-WAY MULTIPOISE INDUCED-COMBUSION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT DELUXE CONDENSING GAS FURNACE. Sizes 040 thru 140. Form No. PDS 350M.40.

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. 58PHA/PHX PERFORMANCE BOOST WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 135,000 Btuh

CONDENSING GAS FURNACE

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

352AAV 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE. Sizes 060 thru 120. Catalog No. PDS 352A.60.1

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Sizes 040 thru 140 FEATURES

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data. 350AAV Highly-Efficient 4-Way Multipoise Fixed-Capacity Deluxe Condensing Gas Furnace Sizes 040 thru 140

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Product Data. 352AAV 4-Way Multipoise Two-Stage Condensing Gas Furnace. Sizes 060 thru 120

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

Product Data STANDARD FEATURES

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Installation, Start---up, Operating and Service and Maintenance Instructions Series 120/C

Installation, Start-up, Operating, and Service and Maintenance Instructions -Series A

Installation, Start---up, Operating and Service and Maintenance Instructions Series 120/C

Installation, Start-up, Operating, and Service and Maintenance Instructions Series 120/C

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Installation, Start-up, Operating, and Service and Maintenance Instructions -Series 120

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace. Input Capacities: 40,000 thru 138,000 Btuh

Product Data. 58CVA/CVX INFINITY 80 VARIABLE SPEED 4---WAY MULTIPOISE GAS FURNACE Input Capacities: 70,000 thru 155,000 Btuh Series 160

Installation, Start-up, Operating, and Service and Maintenance Instructions -Series 100

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MCB 4-WAY MULTIPOISE FIXED-CAPACITY CONDENSING GAS FURNACE Input Rates: 40,000 thru 138,000 Btuh

Single-Stage Deluxe Induced-Combustion 4-Way Multipoise Furnace

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 58MTA Highly-Efficient 4-Way Multipoise Two-Stage Direct-Vent Deluxe Condensing Gas Furnace. Input Capacities: 60,000 thru 120,000 Btuh

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

311AAV Series 100. Installation, Start-up, and Operating Instructions SINGLE-STAGE INDUCED COMBUSTION DELUXE 4-WAY MULTIPOISE FURNACE

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Installation, Start-Up, and Operating Instructions For Sizes , Series 180

355MAV Sizes 040 thru 120 Series E

Product Data. Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace. Series 100 Input Rates: 40,000 thru 120,000 Btuh

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. Perfect Heatt technology, the ultimate in heating comfort...

Installation, Start-Up, and Operating Instructions For Sizes , Series 100

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

PLUS 95st MODEL 355CAV DELUXE 4 -WAY MULTIPOISE VARIABLE -SPEED MULTI -STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh

Product Data. Comfort Heatt technology, the ultimate in heating comfort...

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL SPECIFICATIONS

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data 987MA EVOLUTIONR MODULATING 4 -WAY MULTIPOSE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

Product Data. IdealComfortt technology, the ultimate in heating comfort...

RG7D 1-Stage Heat Series

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Cooling Capacity CFM range

Product Data. 59SC2A Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

G6RC Series TECHNICAL SPECIFICATIONS

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Wt. Lbs Model Number (BTUH) Hz

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

Product Data PG95XAT CONDENSING GAS FURNACE SERIES B STANDARD FEATURES

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

MERIT SERIES Downflow

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

80% A.F.U.E. DOWNFLOW GAS FURNACES

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Transcription:

4-Way Multipoise Induced Combustion Gas Furnace 310AAV/310JAV Sizes 045 thru 155 Series A The 310AAV/310JAV 4-Way Multipoise Gas Furnace was designed by Bryant dealers f Bryant dealers. Applications are easy with 4-way Multipoise design, through-the-furnace downflow venting, 13 different venting options, and a do designed f easy service access. An inner blower do is provided f tighter sealing in sensitive applications. The 310AAV/310JAV furnace is approved f use with natural propane gas, and the 310JAV is approved f use in Low NOx Air Quality Management Districts. STANDARD FEATURES Noise elimination combustion system Four-position furnace: Upflow, Hizontal Right, Hizontal Left, Downflow Thirteen different vent options Compact design only 33-1/3-in. tall Microprocess based smart control center Adjustable heating air temperature rise LED diagnostics and self test feature On-board fuse f transfmer protection Patented blocked vent safeguard to ensure proper furnace venting Heat pump compatible All models are Chimney Friendly when used with accessy vent kit Twinning in Upflow, Downflow, and Hizontal Hot surface ignition (HSI) Residential installations eligible f consumer financing through the Comft Credit Program LIMITED WARRANTY 20-year warranty on Super S heat exchanger 5-year parts warranty on all other components A02182 Fm No. PDS 310A.45.3

28-7/8" 26-1/8" (VENT CONNECTION) 25-1/4" 22-9/16" JUNCTION BOX LOCATION F A D 13/16" 4-13/16" 1-9/16" 2-9/16" AIRFLOW 19" OUTLET 13/16" 7/8" DIA ACCESSORY 1/2" DIA THERMOSTAT WIRE ENTRY 8-7/16" 1-1/2" DIA. RIGHT HAND GAS ENTRY 11/16" 3-15/16" LEFT HAND GAS ENTRY 33-5/16" 24-7/8" 1-7/16" ALTERNATE JUNCTION BOX LOCATION (TYP) 1/2" DIA. THERMOSTAT WIRE ENTRY 7/8" DIA. ACCESSORY VENT OUTLET 5 PLACES (TYP) 3-3/4" 7/8" DIA. ACCESSORY 14-7/8" 11/16" 21-5/8" BOTTOM INLET 24" (CASING) 1-11/16" 5-1/2" E 11/16" 22-1/16" SIDE INLET 1-1/4" 1" NOTES: 1. Two additional 7/8-in. dia knockouts are located in the top plate. 2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturers recommendations f equivalent diameters. 3. Minimum return-air opening at furnace: a. F 800 CFM-16-in. round 14-1/2 x 12-in. rectangle. b. F 1200 CFM-20-in. round 14-1/2 x 19-1/2-in. rectangle. c. F 1600 CFM-22-in. round 14-1/2 x 22-1/16-in. rectangle. d. F airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature f specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, the bottom only will ensure adequate return air openings f airflow requirements above 1800 CFM. A03060 310AAV/310JAV UNIT SIZE A (CABINET WIDTH) D (SUPPLY WIDTH) E (BOTTOM RETURN WIDTH) F (C.L. TOP & BOTTOM VENT OUTLET) VENT CONNECTION SIZE (see notes 1 & 2) SHIPPING WEIGHT 024045 14-3/16 12-9/16 12-11/16 9-5/16 4 104 036045 14-3/16 12-9/16 12-11/16 9-5/16 4 107 024070 14-3/16 12-9/16 12-11/16 9-5/16 4 111 036070 14-3/16 12-9/16 12-11/16 9-5/16 4 115 048070 17-1/2 15-7/8 16-1/8 11-9/16 4 126 042090 17-1/2 15-7/8 16-1/8 11-9/16 4 127 048090 21 19-3/8 19-1/2 13-5/16 4 140 060090 21 19-3/8 19-1/2 13-5/16 4 146 036110 17-1/2 15-7/8 16-1/8 11-9/16 4 135 048110 21 19-3/8 19-1/2 13-5/16 4 146 066110 21 19-3/8 19-1/2 13-5/16 4 152 048135 21 19-3/8 19-1/2 13-5/16 4 (note 1) 149 066135 24-1/2 22-7/8 23 15-1/16 4 (note 1) 163 060155 24-1/2 22-7/8 23 15-1/16 4 (note 1) 170 NOTES: 1) 135 and 155 size furnaces require five-in. vents. Use a 4-5 in. vent adapter between furnace and vent stack. 2) See Installation Instructions f complete installation requirements. D E S I G N MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. ISO 9001:2000 C E R T I I F E D ama Befe purchasing this appliance, read imptant energy cost and efficiency infmation available from your retailer. REGISTERED REGISTERED QUALITY SYSTEM 2

Ø * INSTALLATION MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION DISTANCE MINIMALE EN POUCES AUX CONSTRUCTIONS COMBUSTIBLES This fced air furnace is equipped f use with natural gas at altitudes 0-10,000 ft (0-3,050m). An accessy kit, supplied by the manufacturer, shall be used to convert to propane gas use may be required f some natural gas applications. This furnace is f indo installation in a building constructed on site. This furnace may be installed on combustible floing in alcove closet at minimum clearance as indicated by the diagram from combusitble material. This furnace may be used with a Type B-1 Vent and may be vented in common with other gas fired appliances. Cette fournaise à air pulsé est équipée pour utilisation avec gaz naturel et altitudes comprises entre 0-3,050m (0-10,000 pi). Utiliser une trousse de conversion, fournie par le fabricant, pour passer au gaz propane ou pour certaines installations au gaz naturel. Cette fournaise est prévue pour être installée dans un bâtiment construit sur place. Cette fournaise peut être installée sur un plancher combustible dans une alcôve ou dans un garde-robe en respectant le minimum d'espace libre des matériaux combustibles, tel qu indiqué sur le diagramme. Cette fournaise peut être utilisée avec un conduit d évacuation de Type B-1 ou connectée au conduit ommun d 'autres appareils à gaz. This furnace is approved f UPFLOW, DOWNFLOW, and HORIZONTAL installations. Cette fournaise est approuvée pour l 'installation HORIZONTALE et la circulation d 'air VERS LE HAUT et VERS LE BAS. Clearance arrows do not change with furnace ientation. 0" B A A R C R K I È R E DÉGAGEMENT MINIMUM EN POUCES AVEC ÉLÉMENTS DE CONSTRUCTION COMBUSTIBLES POUR LA POSITION COURANT DESCENDANT: Pour l installation sur plancher non combustible seulement. Pour l installation sur un plancher combustible seulement quand on utilise la base spéciale, pièce nº KGASB0201ALL, l ensemble serpentin, pièce nº CD5 ou CK5, ou le carter de serpentin, pièce nº KCAKC. Ø Dans une alcôve, on doit maintenir un dégagement à l avant de 18 po (450mm). La poistion indiquée concerne le côté d entrée ou de retour quand la fournaise est dans la * position hizontale. Le contact n est permis qu entre les lignes fmées par les intersections du dessus et des deux côtés de la cherrise de la fournaise et les solives, montant sous cadre de charpente. 327590-101 REV. C * 0" S I DE C Ô T É 1" TOP / PLENUM DESSUS / CHAMBRED'AIR BOTTOM DESSOUS 0" F URNACE FOURNAISE FRONT AVANT F R O N T A V A N T 3" Ø S I DE C Ô T È * 0" S E E NTR R VI E C T E I E N MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION DOWNFLOW POSITIONS: Installation on non-combusibible flos only. F Installation on combustible floing only when installed on special base, Part No. KGASB0201ALL, Coil Assembly, Part No. CD5 CK5, Coil Casing, Part No. KCAKC. 18 inches front clearance required f alcove. Indicates supply return sides when furnace is in the hizontal position. Line contact only permissible between lines fmed by intersections of the Top and two Sides of the furnace jacket, and building joists, studs framing. Les fléches de dégagement ne change pas avec l 'ientation de la fournaise. MIN 24" MIN Clearance in inches Dégagement (po). Vent Clearance to combustibles: F Single Wall vents 6 inches (6 po). F Type B-1 vent type 1 inch (1 po). Dégagement de l évent avec combustibles: Pour conduit d évacuation à paroi simple 6 po (6 inches). Pour conduit d évacuation de Type B-1 1 po (1 inch). 3

SPECIFICATIONS UNIT SIZE 024045 036045 024070 036070 048070 042090 048090 RATINGS AND PERFORMANCE Input Btuh* 310JAV Upflow; all 310AAV 44,000 44,000 66,000 66,000 66,000 88,000 88,000 Nonweatherized ICS 310JAVDownflow/Hizontal 42,000 42,000 63,000 63,000 63,000 84,000 84,000 Output Capacity (Btuh) 310JAV Upflow; all 310AAV 35,000 36,000 53,000 54,000 53,000 71,000 71,000 Nonweatherized ICS 310JAVDownflow/Hizontal 34,000 34,000 51,000 51,000 51,000 68,000 68,000 AFUE 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range F 30-60 20-50 40-70 30-60 25-55 40-70 30-60 Certified External Static Pressure Heat/Cool 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.15/0.50 0.15/0.50 Airflow CFM Heating 920 1250 720 1195 1450 1375 1505 Cooling 845 1160 900 1200 1530 1385 1720 ELECTRICAL Unit VoltsHertzPhase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 5.4 7.0 5.0 6.8 9.5 8.2 10.0 Maximum Wire Length (Measure 1 Way in Ft) 49 39 52 40 29 34 28 Minimum Wire Size 14 Maximum Fuse Ckt Bkr Size (Amps)** 15 Transfmer (24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners (Monopt) 2 2 3 3 3 4 4 Gas Connection Size 1/2-in. NPT GAS CONTROLS Gas Valve (Redundant) White Rodgers Min Inlet Pressure (In. wc) 4.5 (Natural Gas) Max Inlet Pressure (In. wc) 13.6 (Natural Gas) Ignition Device Hot Surface Facty-installed ifice Size 43 BLOWER DATA Direct-Drive Mot HP (PSC) 1/5 1/3 1/5 1/3 1/2 1/3 1/2 Mot Full Load Amps 2.9 5.2 2.9 5.2 7.9 5.2 7.9 RPM (Nominal)-Speeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 Blower Wheel Diameter x Width (in.) 10 x 6 10 x 6 10 x 6 10 x 6 11 x 8 10 x 8 10 x 10 * Gas input ratings are certified f elevations to 2000 ft. F elevations above 2000 ft, reduce ratings 4 percent f each 1000 ft above sea level. Refer to National Fuel Gas Code Table F4 furnace installation instructions. In Canada, derate the unit 10 percent f elevations 2000 ft to 4500 ft above sea level. Capacity in accdance with U.S. Government DOE test procedures. Airflow shown is f bottom only return-air supply f the as-shipped speed tap. F air delivery above 1800 CFM, see Air Delivery table f other options. A filter is required f each return-air supply. An airflow reduction of up to 7 percent may occur when using the facty-specified 4-5/16 in. wide, high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 4

SPECIFICATIONS continued UNIT SIZE 060090 036110 048110 066110 048135 066135 060155 RATINGS AND PERFORMANCE Input Btuh* 310JAV Upflow; all 310AAV 88,000 110,000 110,000 110,000 132,000 132,000 154,000 Nonweatherized ICS 310JAVDownflow/Hizontal 84,000 105,000 105,000 105,000 126,000 126,000 147,000 Output Capacity (Btuh) 310JAV Upflow; all 310AAV 71,000 89,000 89,000 89,000 107,000 107,000 125,000 Nonweatherized ICS 310JAVDownflow/Hizontal 68,000 85,000 85,000 85,000 102,000 102,000 119,000 AFUE 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range F 25-55 50-80 40-70 30-60 50-80 40-70 45-75 Certified External Static Pressure Heat/Cool 0.15/0.50 0.20/0.50 0.20/0.50 0.20/0.80 0.20/0.50 0.20/0.50 0.20/0.50 Airflow CFM Heating 1990 1335 1515 1900 1525 1850 Cooling 2025 1355 1680 2220 1710 2110 2230 ELECTRICAL Unit VoltsHertzPhase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 13.6 8.2 10.1 14.8 10.2 14.4 15.0 Maximum Wire Length (Measure 1 Way in Ft) 32 34 28 30 27 30 29 Minimum Wire Size 12 14 12 14 12 Maximum Fuse Ckt Bkr Size (Amps)** 20 15 20 15 20 Transfmer (24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners (Monopt) 4 5 5 5 6 6 7 Gas Connection Size 1/2-in. NPT GAS CONTROLS Gas Valve (Redundant) White Rodgers Min Inlet Pressure (In. wc) 4.5 (Natural Gas) Max Inlet Pressure (In. wc) 13.6 (Natural Gas) Ignition Device Hot Surface Facty-installed ifice Size 43 BLOWER DATA Direct-Drive Mot HP (PSC) 3/4 1/3 1/2 3/4 1/2 3/4 3/4 Mot Full Load Amps 11.1 5.2 7.9 11.1 7.9 11.1 11.1 RPM (Nominal)-Speeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 Blower Wheel Diameter x Width (in.) 11 x 11 10 x 8 10 x 10 11 x 11 10 x 10 11 x 11 11 x 11 * Gas input ratings are certified f elevations to 2000 ft. F elevations above 2000 ft, reduce ratings 4 percent f each 1000 ft above sea level. Refer to National Fuel Gas Code Table F4 furnace installation instructions. In Canada, derate the unit 10 percent f elevations 2000 ft to 4500 ft above sea level. Capacity in accdance with U.S. Government DOE test procedures. Airflow shown is f bottom only return-air supply f the as-shipped speed tap. F air delivery above 1800 CFM, see Air Delivery table f other options. A filter is required f each return-air supply. An airflow reduction of up to 7 percent may occur when using the facty-specified 4-5/16 in. wide, high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 5

SEE NOTES: 1,2,4,7,8,9 UPFLOW A02058 SEE NOTES: 1,2,3,4,7,8,9 UPFLOW A02059 SEE NOTES: 1,2,4,5,7,8,9 DOWNFLOW A02061 SEE NOTES:1,2,3,4,5,7,8,9 DOWNFLOW A02060 SEE NOTES: 1,2,3,4,5,7,8,9 DOWNFLOW A02063 SEE NOTES: 1,2,4,5,6,7,8,9 DOWNFLOW A02062 Venting Notes 1. F common vent, vent connect sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), ANSI Z223.1/NFPA 54. In Canada, latest edition of the National Standards of Canada, Natural Gas and Propane Installation Code (NSCNGPIC), CSA B149.1-00. 2. Immediately increase to 5-in. vent connect outside furnace casing when 5-in. vent connect required, refer to Note 1. 3. Side outlet vent f upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when KGAVG0101DFG is used in downflow position. 4. Type B vent where required, refer to Note 1. 5. 4 in. single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit. 6. Accessy Downflow Vent Guard Kit, KGAVG0101DFG required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required f exteri masonry chimney applications. Refer to Chimney Adapter Kit, KGACA02014FC and KGACA02015FC f sizing and complete application details. 8. Secure vent connect to furnace elbow with (2) crosion-resistant sheet metal screws, space approximately 180 o apart. 9. Secure all other single wall vent connect joints with (3) crosion-resistant screws spaced approximately 120 o apart. Secure Type B vent connects per vent connect manufacturer's recommendations. 6

SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT A02068 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT A02070 SEE NOTES: 1,2,4,7,8,9 HORIZONTAL RIGHT A02069 SEE NOTES: 1,2,4,7,8,9 HORIZONTAL LEFT A02064 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT A02065 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT A02066 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT A02067 7

ACCESSORIES DESCRIPTION PART NO. 024045 036045 024070 036070 048070 042090 048090 060090 036110 048110 066110 048135 066135 060155 Preferred Series Filter Cabinet Cartridge Media Filter EZ Flex Media Filter with End Caps Replacement EZ Flex Filter Media FILCABBB0016 X X X X X X X FILCABBB0020 X X X X X FILCABBB24 X X FILBBCAR0016 X X X X X X X FILBBCAR0020 X X X X X FILBBCAR0024 X X EXPXXUNV0016 X X X X X X X EXPXXUNV0020 X X X X X EXPXXUNV0024 X X EXPXXFIL0016 X X X X X X X EXPXXFIL0020 X X X X X EXPXXFIL0024 X X KGAFR0401B14 X X X X External Return Filter Rack KGAFR0501B17 X X X KGAFR0601B21 X X X X X KGAFR0701B24 X X External Side Return Filter Rack KGAFR0801SRE X X X X X X X X X X X X X X KGAWF1306UFR X X X X X X S S X S S S S S Unframed Filter, 1-in. KGAWF1406UFR X X X X X KGAWF1506UFR X X Flue Extension KGAFE0112UPH X X X X X X X X X X X X X X Twinning Kit KGATW0601HSI X X X X X X X X X X X X X X Combustible Flo Base KGASB0201ALL X X X X X X X X X X X X X X Downflow Vent Guard KGAVG0101DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X Chimney Adapter Kit KGACA02014FC X X X X X X X X X X X Chimney Adapter Kit KGACA02015FC X X X Natural-to-Propane Conversion Kit * KGANP3001ALL X X X X X X X X X X X X X X Propane-to-Natural Conversion Kit KGAPN2301ALL X X X X X X X X X X X X X X Label Kit KGALB0101KIT X X X X X X X X X X X X X X Gas Orifice Kit (Qty 50) UV Lights Heat/Energy Recovery Ventilat Humidifier Electronic Mechanical Air Cleaner KGAHA0150N42 KGAHA0250N43 (facty supplied) KGAHA0350N44 KGAHA0450N45 KGAHA0550N46 KGAHA1550N47 KGAHA1650N48 KGAHA0650P54 KGAHA0750P55 * Facty authized, field installed. Fuel conversion kits are CSA recognized. Suitable f side return. An external filter is required f right-side return-air installations. See Installation Instructions f model, altitude, and heat value usages. Model UVL Models HRV ERV Model HUM Model EACA, EZXCAB, FILCAB 8

AIR DELIVERY-CFM (With Filter)* 310AAV/JAV UNIT SIZE 024045 036045 024070 036070 048070 042090 048090 060090 036110 048110 066110 048135 066135 060155 RETURN-AIR SUPPLY Only Both Sides 1 Side & 1 Side Only Only Both Sides 1 Side & 1 Side-Only Only Both Sides 1 Side & 1 Side-Only Only Both Sides 1 Side & 1 Side Only SPEED Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- Med- EXTERNAL STATIC PRESSURE (In. wc) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1085 920 820 1440 1360 1250 1030 835 725 1425 1320 1200 1805 1630 1460 1650 1515 1385 2060 1505 2405 2225 2020 2530 2285 1995 2475 2260 1950 1625 1510 1360 2035 1745 1530 2530 2230 1920 2235 2540 2125 2090 1545 2485 2195 2180 2135 2465 2115 1800 2155 1800 2140 1800 1035 875 775 1375 1300 1210 1010 815 700 1375 1280 1175 1740 1585 1420 1600 1485 1360 1985 1765 1505 2310 2155 1955 2450 2215 1945 2395 2190 1910 1575 1470 1335 1965 1710 1515 2470 2205 1900 2200 2495 2120 1795 2010 1755 1520 2400 2150 1850 2145 1850 2085 1850 2430 2105 2135 2095 975 830 730 1305 1240 1160 980 790 675 1320 1240 1145 1670 1530 1385 1535 1440 1320 1915 1715 1480 2220 2080 2365 2150 1900 2300 2110 1855 1515 1415 1295 1650 1470 2400 2165 2415 2155 2430 2105 1930 1705 1500 2310 2090 1820 2385 2060 1820 2245 2035 1820 2375 2075 1770 2375 2095 1770 2260 2040 1770 915 770 680 1240 1175 1100 945 760 645 1265 1205 1105 1600 1470 1325 1465 1380 1260 1820 1645 1440 2130 1995 1805 2270 2075 1840 2200 2035 1795 1445 1355 1250 1560 1400 2320 2110 1845 2350 2100 2355 2060 1765 1835 1640 1450 2215 2000 1780 2305 2010 1780 2155 1975 1780 2305 2030 1735 2285 2040 1735 2180 1975 1735 845 710 620 1160 1115 1040 900 720 600 1200 1140 1050 1530 1405 1280 1385 1300 1195 1720 1560 1375 2025 1895 2165 1985 1770 2090 1940 1355 1285 1180 1680 1450 1310 2220 2035 1795 2250 2040 2265 2010 1720 1710 1550 1380 2110 1920 1715 2195 1945 1715 2055 1895 1715 2230 1980 1695 2200 1975 1695 2085 1890 1695 770 640 555 1070 1040 965 845 675 555 1125 1075 990 1445 1330 1220 1285 1220 1120 1610 1470 1300 1920 1785 1630 2065 1890 1685 1985 1845 1650 1260 1185 1100 1495 1340 1215 2115 1950 2145 1955 2175 1940 1650 1590 1465 1315 2000 1825 1635 2085 1865 1635 1940 1795 1635 2110 1910 1640 2105 1895 1640 1975 1810 1640 675 555 470 975 950 885 775 610 475 1035 995 920 1360 1255 1155 1175 1115 1025 1490 1345 1190 1675 1535 1940 1780 1600 1865 1735 1555 1165 1070 985 1365 1205 1095 2000 1855 1650 2015 1850 2065 1840 1585 1470 1360 1215 1720 1540 1960 1765 1540 1825 1685 1540 2000 1830 1570 1995 1570 1865 1705 1570 565 440 360 870 850 790 680 490 390 940 905 840 1280 1170 1080 1055 990 915 1340 1195 1045 1660 1565 1420 1805 1660 1480 1620 1445 990 890 810 1215 1090 990 1865 1740 1555 1875 1740 1935 1500 1335 1210 1005 1725 1565 1415 1825 1660 1415 1695 1565 1415 1865 1725 1465 1870 1685 1465 1740 1595 1465 390 250 190 730 725 670 490 375 300 830 790 725 1180 1080 995 895 830 710 1135 1010 890 1530 1420 1275 1670 1525 1350 1585 1475 1310 195 560 575 520 335 265 655 620 555 1075 990 910 645 600 565 925 820 740 1350 1260 1135 1505 1360 1180 1425 1325 1150 785 725 1075 955 830 1615 1460 1715 1595 1785 1615 1390 1025 945 855 1535 1405 1290 1670 1515 1290 1555 1445 1290 1725 1590 1345 1550 1345 1605 1480 1345 875 750 670 1590 1485 1340 1560 1470 1650 1485 1280 835 785 670 1355 1255 1160 1465 1325 1160 1385 1265 1160 1545 1425 1225 1570 1400 1225 1455 1325 1225 * A filter is required f each return-air supply. Airflow perfmance includes 1 in. washable filter media such as contained in facty-authized accessy filter rack. To determine airflow perfmance without this filter, assume an additional.1 available external static pressure. Indicates unstable operating conditions. 9

CONTROLS THERMOSTAT AND ZONING DESCRIPTION NON-PROGRAMMABLE F use with 1-speed Air Conditioner - deg. F/C, Auto Changeover F use with 1-speed Air Conditioner - deg. F/C, Auto Changeover F use with 2-speed Air Conditioner - deg. F/C, Auto Changeover F use with multi-use / stage configurations - deg. F/C, Auto Changeover/Temperature and Humidity Control PROGRAMMABLE THERMOSTAT SELECTION F use with 1-speed Air Conditioner - deg. F/C, Auto Changeover, 7-Day Programmable F use with 1-speed Air Conditioner - deg. F/C, Auto Changeover, 7-Day Programmable F use with 2-speed Air Conditioner - deg. F/C, Auto Changeover, 7-Day Programmable F use with 1-speed Air Conditioner - deg. F/C, 5-2 Day Programmable F use with multi-stage applications - deg. F/C, Auto Changeover, 7-Day Programmable F multi-use / stage configurations - deg. F/C, Auto Changeover, 7-Day Programmable/Temperature and Humidity Control ZONING CONTROL SELECTION Zone Perfect 2-Zone kit Zone Perfect Plus 2-Zone kit/temperature and Humidity Control Zone Perfect Plus 4-Zone kit/temperature and Humidity Control Zone Perfect Plus 8-Zone kit/temperature and Humidity Control PART NO. TSTATBBNAC01-B TSTATBBNHP01-B* TSTATBBN2S01-B* TSTATBBPRH01-B TSTATBBPAC01-B TSTATBBPHP01-B* TSTATBBP2S01-B* TSTATBBSAC01 TSTATBBPDF01-B TSTATBBPRH01-B ZONEKIT2ZBDP ZONEBB2KIT01-B ZONEBB4KIT01-B ZONEBB8KIT01-B * Model HP and 2S thermostat must be field converted to air conditioner operation. Thermidistat Control can be configured f multiple use and staging, it must be configured f each specific application. Dual Fuel thermostat is used with furnace and heat pump application. 10

11

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Fm: PDS 310A.45.3 Cancels: PDS 310A.45.2 2004 Bryant Heating & Cooling Systems, 7310 W. Mris St., Indpls., IN 46231 PRINTED IN USA Catalog No. 5231-003 09-04 12