SMALL AIR COOLED CONDENSERS

Similar documents
BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

Air-Cooled Condensers

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

Air-Cooled Condensers

Air-Cooled Condensers

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Air-Cooled Condensers

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

JCseries EVAPORATIVE CONDENSER. engineering data

KCC Centrifugal Fan Air Cooled Condensers

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Installation, Operation, and Maintenance Information

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

MACH N-407 Heat Pump Air-Cooled Chiller

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

C13-Series Engineering Guide

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Kramersaver Air Cooled Condensing Units

KCS-Line Air Cooled Condensers

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

MAC N-407 Air-Cooled Chiller

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

High Profile Evaporator

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Center Mount Unit Coolers

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

VertiCool Aurora Engineering Guide

TAB Centrifugal Fan Air Cooled Condensers

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

PACKAGED AIR COOLED Product Data Catalog

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

MAC-120HE-03 Air-Cooled Chiller

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

E ASY INSTALLATION M ULTIPLE REFRIGERATION CIRCUITS

Super-Flo Low Profile Unit Cooler

Low Profile Unit Coolers

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

technical guide Water-Cooled Self-Contained Units

Liebert Air-Cooled Fin/Tube Condensers

Commercial High-Efficiency Condensing Units

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

LOW PROFILE UNIT COOLER

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Commercial High-Efficiency Condensing Units

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Model VDC Direct-Drive Remote Air-Cooled Condensers

Water-Cooled Self-Contained Units

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Low Profile Unit Coolers

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

13 SEER CONDENSING UNITS & AIR HANDLERS

RSG16**S1M. Split System Air Conditioner 16 SEER

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Advance Release September 2009

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Condensing Units & Air Handlers

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

PAR5. Product Specifications

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

Transcription:

Catalog KM-KDX-0816A Supersedes Catalog KM-KDS-1014A UNICON SMALL AIR COOLED CONDENSERS

2 Unicon Efficient and Reliable Kramer s Remote Air Cooled Condensers innovative design provides a wide array of solutions focusing on performance, energy efficiency, reduced sound output and other requirements to meet the needs of the grocery, supermarket, industrial cooling and commercial warehousing industries. Standard Features Direct drive motor arrangement Vertical air flow 1075 or 850 RPM motors Motors with inherent thermal overload protection Copper tube, aluminum fin coils Leak tested at 450 PSIG Vinyl coated heavy gauge steel fan guards Heavy gauge galvanized steel construction for superior corrosion resistance Internal divider isolates fan cells (2 fan models) Options Fan cycling head pressure control (2 fan models) Variable speed fan control (header end fan only) Flooded head pressure control Sub-cooling circuit Horizontal air flow Multi-circuited coils Wide selection of fin coatings and materials MODEL NUMBER NOMENCLATURE K D S 007 D A 2 B 1 2 A 1 A I II III IV V VI VII VIII IX X XI XII XIII I. Model Series K Witt II. III. Unit Type D Condenser Series S Single fan wide IV. Capacity Three Number Characters V. Voltage Code A 115V/1/60 D 208-230V/1/60 E 208-230V/3/60 F 460V/1/60 G 460V/3/60 VI. Motor/Fan Type A 1075 RPM, 0.33 HP, Metal Blade C 850 RPM, 0.25 HP, Metal Blade H 1075 RPM, 0.5 HP Totally Enclosed, Metal Blade VII. Length in Fans 1 or 2 VIII. Coil Density A 8 fpi B 10 fpi C 12 fpi H 575V/1/60 Codes D, E, F, and G can be used with 50 or 60 Hz power D 14 fpi IX. Coil Material and Coating Options* 1 Aluminum fins 2 Copper fins 3 Al + AST coating 6 Al + Heresite 7 Al + Polyester coat - Pre Coated Fin Material X. Housing Material and Coatings* 1 Aluminum 2 Galvanized 7 Stainless Steel 316L XI. Unit Design Configuration A Vertical Fan Discharge, Standard Legs E Vertical Fan Discharge, 30 Legs N Horizontal Fan Discharge, Standard Legs XII. Circuit Splitting Options 1 Full 2 50/50 XIII. Revision Code Single Alphanumeric Character A Initial Release * Contact Application Engineering to obtain price quotes for special fin materials or coatings. Table of Contents Page(s) Features and Options Chart... 3 Condenser Selection Procedure... 4-5 Head Pressure Control Option... 6 Performance and Specifications Physical Dimensions and Drawings... 6 1140 RPM Models... 7 850 RPM Models... 8

Small Air Cooled Condensers 3 Features and Options GENERAL CONSTRUCTION CONDENSER COIL AND CIRCUITING FIN MATERIALS, SPACING AND COATINGS FAN/ MOTOR ELECTRICAL PANEL REFRIGERANT SPECIALTIES SHIPPING Vertical Air Discharge Configuration Horizontal Air Discharge Configuration* Galvanized Steel Casing Stainless Steel 316 or Aluminum Casing Protective Coating for External Casing Heavy Guage Galvanized Steel Legs Aluminum Tube Sheets DESCRIPTION Vertical Discharge - Leg Length 15" Vertical Discharge - Leg Length 30 Copper Tubes Mechanically Expanded into Aluminum Fins Leak tested at 450 PSIG Coil Circuiting: Fin Spacing: Fin Materials: Fin Coatings: Single Circuit 50/50 Multi-Circuiting Sub-Cooling Circuits 10 Fins per inch 8, 12 or 14 Fins Per Inch Aluminum Fins Copper Fins or Polyester-Coated Fin Stock None Welded Heavy Gauge Rod Mounting Frame Fully Baffled Fan Modules Motor Type: ElectroFin or Heresite, or Energy Guard Open Type Enclosed Opposite Header End Mounting Location: Left hand or Right hand (viewing header) or Header End Temp. or Press. Fan Cycling (2 fan models only) Variable Speed Header End Fan Control - Pressure Controlled Flooded-Condenser Control Valve System (Loose) Vertical Air Discharge Models - Legs Disassembled - Unit in Carton or Crate Horizontal Discharge Models* - Legs Disassembled - Unit in Carton or Crate * Horizontal discharge orientation is available using standard leg arrangement.

4 Unicon Condenser Selection Air-cooled condenser capacity ratings are based on the total heat rejection of the refrigeration system. Total heat of rejection is the sum of the net refrigeration effect and heat of compression added to the refrigerant in the compressor. The heat of compression varies with the compressor design, so the compressor manufacturer s information should be used whenever possible. If the compressor manufacturer s heat of compression information is not available, Tables 1 and 2 (page 5) may be used to determine the heat of compression. The following formulas may be used to calculate the total heat rejection (THR) for systems that fall outside the normal limits of single stage compressor applications, such as compound or cascade systems. Suction cooled hermetic compressors: THR = Compressor Capacity (BTUH) + (3,413 x KW) Open Compressors THR =Compressor Capacity (BTUH) + (2,545 x BHP) ELEVATION CORRECTION Elevation above sea level has an effect on the performance of air cooled condensers. Divide the required capacity by the Elevation Correction Factor in the table on page 5 to correct the requirement to Sea Level Conditions. The proper condenser can then be selected from the appropriate table on Pages 7 or 8. SINGLE CIRCUIT CONDENSERS All units are available for single circuit applications. SELECTION EXAMPLE Given: Ambient Air Temperature = 95 F Maximum Condensing Temperature = 110 F Evaporator Temperature = 20 F Refrigerant = R-404A Compressor Capacity = 50,000 BTU Compressor Type = Suction Cooled Semi-Hermetic Solution: Multiply the compressor capacity by the heat of compression factor to calculate the required total heat of rejection (THR). Table 1 shows that for 110 F condensing temperature and 20 F evaporator temperature, the heat of compression factor is 1.33. The required total heat rejection (THR) is: 50,000 x 1.33 = 66,500 BTUH THR Divide the THR by the design condensing temperature of 15 F TD. (TD = Condensing Temperature - Ambient Temperature) 66,500 15 = 4,433 BTUH per 1 F TD Convert BTUH to MBH. 4,433 BTUH 1,000 = 4.43 MBH per 1 F TD The correct selection of a single fan width unit with 1140 RPM fan motors (page 7) is a model KDS007*A2B12A1A with a capacity of 4.6 MBH @ 14FPI. Since the unit selection will almost never have the exact required capacity, the actual TD will vary slightly from the design TD. The actual TD can be calculated using the following formula: Actual TD = Design THR Actual Condenser THR x Design TD For this example the actual TD would be: Actual TD = 4.43 4.6 x 15 = 14.4 F TD

Small Air Cooled Condensers 5 Table 1: Heat of Compression Factors Suction Cooled Compressors Evap Temp F Condensing Temperature F 90 95 100 105 110 115 120 125 130-40 1.66 1.70 1.73 1.76 1.80 1.90 2.00-35 1.61 1.64 1.68 1.70 1.74 1.82 1.90-30 1.57 1.60 1.62 1.65 1.68 1.74 1.80-25 1.53 1.56 1.58 1.60 1.63 1.67 1.72-20 1.49 1.51 1.53 1.55 1.58 1.61 1.65-15 1.46 1.48 1.50 1.51 1.54 1.57 1.61-10 1.42 1.44 1.46 1.48 1.50 1.53 1.57 1.60 1.64-5 1.39 1.41 1.43 1.45 1.47 1.50 1.53 1.56 1.60 0 1.36 1.38 1.40 1.42 1.44 1.47 1.50 1.53 1.56 +5 1.33 1.35 1.37 1.39 1.41 1.43 1.46 1.49 1.52 +10 1.31 1.32 1.34 1.36 1.38 1.40 1.43 1.46 1.49 +15 1.28 1.30 1.32 1.33 1.35 1.37 1.40 1.43 1.46 +20 1.26 1.27 1.29 1.31 1.33 1.35 1.37 1.40 1.43 +25 1.24 1.25 1.27 1.29 1.31 1.33 1.35 1.37 1.40 +30 1.22 1.23 1.25 1.26 1.28 1.30 1.32 1.34 1.37 +35 1.20 1.21 1.23 1.25 1.26 1.27 1.29 1.31 1.34 +40 1.18 1.19 1.21 1.23 1.24 1.25 1.27 1.29 1.31 +45 1.16 1.17 1.19 1.21 1.22 1.23 1.25 1.26 1.28 +50 1.14 1.15 1.17 1.19 1.20 1.22 1.23 1.24 1.26 A. Beyond the normal limits for single stage compressor application. Table 2: Heat of Compression Factors Open Compressors Evap Temp Condensing Temperature F F 90 95 100 105 110 115 120 125 130-30 1.37 1.39 1.42 1.44 1.47-20 1.33 1.35 1.37 1.39 1.42 1.44 1.47-10 1.28 1.30 1.32 1.34 1.37 1.39 1.42 1.44 1.47 0 1.24 1.26 1.28 1.30 1.32 1.34 1.37 1.39 1.41 +10 1.21 1.23 1.24 1.26 1.28 1.30 1.32 1.34 1.36 +20 1.17 1.18 1.20 1.22 1.24 1.26 1.28 1.30 1.32 +30 1.14 1.15 1.17 1.18 1.20 1.22 1.24 1.25 1.27 +40 1.12 1.14 1.15 1.16 1.17 1.18 1.20 1.21 1.23 +50 1.09 1.11 1.12 1.13 1.14 1.16 1.17 1.19 1.20 A. Beyond the normal limits for single stage compressor application. Table 3: Elevation Correction Factors Elevation (ft) 1,000 2,000 3,000 4,000 5,000 6,000 8,000 10,000 12,000 14,000 16,000 Correction Factor 0.94 0.93 0.90 0.88 0.86 0.83 0.79 0.75 0.71 0.66 0.62

6 Unicon Head Pressure Control Options FLOODED CONDENSER The Flooded Condenser Head Pressure Control Option maintains adequate condensing pressure while operating in low ambient temperatures. By flooding the condenser with liquid refrigerant, the amount of coil surface available for condensing is reduced. The resulting reduction in capacity ensures proper operation of the thermal expansion valve. This option requires a modulating three-way valve, dependent on refrigerant discharge pressure, be placed at the condenser outlet. A fall in ambient temperature causes a corresponding fall in discharge pressure. The valve modulates allowing discharge gas to flow to the receiver, creating a higher pressure at the condenser outlet. This higher pressure reduces the flow out of the condenser, causing liquid refrigerant to back up in the coil. Flooding the condenser reduces the available condensing surface and raises the condensing pressure so that adequate high-side pressure is maintained. A larger receiver and additional refrigerant are required for systems with flooded condenser control. The receiver can be conveniently installed directly under the condenser in most applications. However, if the system will be operational in ambient temperatures below 55 F, the receiver should be located in a warm environment or heated. In this situation, a check valve must be installed in the line between the receiver and condenser valve. This prevents refrigerant migration from the receiver to the condenser. The amount of additional refrigerant charge is based on the lowest expected winter operating temperature and the design TD. In addition to the condenser charge, the operating charges of the evaporator, receiver and refrigerant lines must be added to determine the total system refrigerant charge. The pump-down capacity (80% of full capacity) of the receiver must be at least equal to the total system charge. Physical Data Drawing A B C D E F KDS001*A1 KDS001*C1 1 12-1/2 28 25-9/16 13-3/4 26-5/8 26-13/16 KDS002*A1 KDS002*C1 1 12-1/2 28 25-9/16 13-3/4 26-5/8 26-13/16 KDS003*A1 KDS003*C1 1 14-3/8 33 30-9/16 15-5/8 31-5/8 31-13/16 KDS005*A1 KDS004*C1 1 14-3/8 33 30-9/16 15-5/8 31-5/8 31-13/16 KDS007*A2 KDS006*C2 2 14-3/8 66 30-9/16 15-5/8 64-5/8 31-13/16 KDS009*A2 KDS008*C2 2 14-3/8 66 30-9/16 15-5/8 64-5/8 31-13/16 KDS011*A2 KDS009*C2 2 14-3/8 66 30-9/16 15-5/8 64-5/8 31-13/16 DRAWING - 1 FAN DRAWING - 2 FAN Note: All dimensions are in inches.

Small Air Cooled Condensers 7 Performance Data - 1075 RPM Fan Motors THR MBH 1 F TD - R407A THR MBH 1 F TD - R404A & R507 Fins Per Inch Fins Per Inch 8 10 12 14 8 10 12 14 KDS001*A1B12A1A 0.67 0.77 0.82 0.95 0.73 0.84 0.90 1.04 KDS002*A1B12A1A 1.16 1.26 1.38 1.48 1.17 1.33 1.45 1.57 KDS003*A1B12A1A 1.52 1.72 1.89 2.04 1.60 1.81 1.99 2.15 KDS005*A1B12A1A 2.18 2.43 2.61 2.75 2.23 2.48 2.68 2.81 KDS007*A2B12A1A 3.25 3.69 4.05 4.37 3.42 3.89 4.27 4.60 KDS009*A2B12A1A 4.47 4.98 5.34 5.64 5.46 5.06 5.45 5.76 KDS011*A2B12A1A 5.37 5.85 6.16 6.52 5.31 5.79 6.10 6.45 * Each asterisk represents a variable character based upon voltage and vintage ordered. See page 2 for complete nomenclature. For R-22 capacity, multiply R404A unit capacity by 1.02 For R-407C capacity, multiply R407A capacity by.98 For R-134a capacity multiply R-404A unit capacity by.97 For R-410A capacity, multiply R404A capacity by 1.08 Notes: R-407A ratings are based on Mean Condensing Temperature which is the average of the Dew Point and Bubble Point temperatures corresponding to the refrigerant temperature at the condenser inlet. Specifications - 1075 RPM Fan Motors Fans Quantity Diameter CFM dba Maximum Circuit Quantity Connection (Inches)^ Connection Quantity Net Weight (Lbs.) Unit kw KDS001*A1B12A1A 1 18 3,020 47.0 5 7/8 2 80 0.28 KDS002*A1B12A1A 1 18 2,840 47.0 10 7/8 2 86 0.28 KDS003*A1B12A1A 1 22 4,450 57.0 12 7/8 2 107 0.47 KDS005*A1B12A1A 1 22 3,900 57.0 18 7/8 2 116 0.47 KDS007*A2B12A1A 2 22 8,640 60.0 18 1-1/8 2 164 0.94 KDS009*A2B12A1A 2 22 7,780 60.0 27 1-1/8 2 179 0.94 KDS011*A2B12A1A 2 22 7,080 60.0 36 1-1/8 2 195 0.94 208-230/1/60 208-230/3/60 460/1/60 460/3/60 575/1/60 FLA MCA MOPD FLA MCA MOPD FLA MCA MOPD FLA MCA MOPD FLA MCA MOPD KDS001*A1B12A1A 3.2 15.0 15 1.8 15.0 15 1.3 15.0 15 0.9 15.0 15 1.0 15.0 15 KDS002*A1B12A1A 3.2 15.0 15 1.8 15.0 15 1.3 15.0 15 0.9 15.0 15 1.0 15.0 15 KDS003*A1B12A1A 3.2 15.0 15 1.8 15.0 15 1.3 15.0 15 0.9 15.0 15 1.0 15.0 15 KDS005*A1B12A1A 3.2 15.0 15 1.8 15.0 15 1.3 15.0 15 0.9 15.0 15 1.0 15.0 15 KDS007*A2B12A1A 6.4 15.0 15 3.6 15.0 15 2.6 15.0 15 1.8 15.0 15 2.0 15.0 15 KDS009*A2B12A1A 6.4 15.0 15 3.6 15.0 15 2.6 15.0 15 1.8 15.0 15 2.0 15.0 15 KDS011*A2B12A1A 6.4 15.0 15 3.6 15.0 15 2.6 15.0 15 1.8 15.0 15 2.0 15.0 15 * Each asterisk represents a variable character based upon voltage and vintage ordered. See page 2 for complete nomenclature. Sound pressure dba @ 10 feet. ^ Standard connection sizes are for no circuit split. Header diameters are one size larger than connection sizes. Variance from standard operating conditions may result in connection sizes which are different from those listed above.

Unicon Performance Data - 850 RPM Fan Motors THR MBH 1 F TD - R407A THR MBH 1 F TD - R404A & R507 Fins Per Inch Fins Per Inch 8 10 12 14 8 10 12 14 KDS001*C1B12A1A 0.63 0.73 0.81 0.90 0.68 0.79 0.88 0.97 KDS002*C1B12A1A 1.05 1.19 1.31 1.41 1.09 1.24 1.36 1.47 KDS003*C1B12A1A 1.38 1.57 1.72 1.86 1.44 1.63 1.79 1.93 KDS004*C1B12A1A 1.97 2.19 2.35 2.49 1.97 2.19 2.35 2.49 KDS006*C2B12A1A 2.97 3.37 3.71 4.00 3.09 3.51 3.86 4.16 KDS008*C2B12A1A 4.04 4.50 4.82 5.10 4.05 4.51 4.83 5.11 KDS009*C2B12A1A 4.69 5.12 5.39 5.70 4.53 4.94 5.21 5.50 * Each asterisk represents a variable character based upon voltage and vintage ordered. See page 2 for complete nomenclature. For R-22 capacity, multiply R404A unit capacity by 1.02 For R-407C capacity, multiply R407A capacity by.98 For R-134a capacity multiply R-404A unit capacity by.97 For R-410A capacity, multiply R404A capacity by 1.08 Notes: R-407A ratings are based on Mean Condensing Temperature which is the average of the Dew Point and Bubble Point temperatures corresponding to the refrigerant temperature at the condenser inlet. Specifications - 850 RPM Fan Motors Fans Quantity Diameter CFM dba Maximum Circuit Quantity Connection (Inches)^ Connection Quantity Net Weight (Lbs.) Unit kw KDS001*C1B12A1A 1 18 2,470 47.0 5 7/8 2 80 0.11 KDS002*C1B12A1A 1 18 2,110 47.0 10 7/8 2 86 0.11 KDS003*C1B12A1A 1 22 3,290 52.0 12 7/8 2 107 0.20 KDS004*C1B12A1A 1 22 2,880 52.0 18 7/8 2 116 0.20 KDS006*C2B12A1A 2 22 6,390 55.0 18 1-1/8 2 164 0.40 KDS008*C2B12A1A 2 22 5,760 55.0 27 1-1/8 2 179 0.40 KDS009*C2B12A1A 2 22 5,170 55.0 36 1-1/8 2 195 0.40 208-230/1/60 208-230/3/60 460/1/60 460/3/60 575/1/60 FLA MCA MOPD FLA MCA MOPD FLA MCA MOPD FLA MCA MOPD FLA MCA MOPD KDS001*C1B12A1A 1.4 15.0 15 1.1 15.0 15 0.7 15.0 15 0.6 15.0 15 KDS002*C1B12A1A 1.4 15.0 15 1.1 15.0 15 0.7 15.0 15 0.6 15.0 15 KDS003*C1B12A1A 1.4 15.0 15 1.1 15.0 15 0.7 15.0 15 0.6 15.0 15 KDS004*C1B12A1A 1.4 15.0 15 1.1 15.0 15 0.7 15.0 15 0.6 15.0 15 KDS006*C2B12A1A 2.8 15.0 15 2.2 15.0 15 1.4 15.0 15 1.2 15.0 15 KDS008*C2B12A1A 2.8 15.0 15 2.2 15.0 15 1.4 15.0 15 1.2 15.0 15 KDS009*C2B12A1A 2.8 15.0 15 2.2 15.0 15 1.4 15.0 15 1.2 15.0 15 * Each asterisk represents a variable character based upon voltage and vintage ordered. See page 2 for complete nomenclature. Sound pressure dba @ 10 feet. ^ Standard connection sizes are for no circuit split. Header diameters are one size larger than connection sizes. Not available in 575V. Variance from standard operating conditions may result in connection sizes which are different from those listed above. Due to continuing product development, specifications are subject to change without notice. 3885 Crestwood Pkwy., Ste. 500 Duluth, Georgia 30096 PHONE (678) 323-4904 FAX (678) 323-4920 kramer.htpgusa.com E-mail or call us for help: parts@htpgusa.com or (800) 288-9488