MetaAlloy CI Primer Repair System

Similar documents
Instructions for Coating Fimbel Garage Door Panels

Instructions for Coating Cellular PVC Solid Color (brushing and spraying)

Abrasion Resistance of Fluoropolymer and polyester Coatings

ST-1 Surface Treatment

SpectraPrime Color Primer Surfacer

Handheld Training Manual

SpectraSeal 2.1 VOC Color Primer Sealer

Rhinoskin Spray On Insulation Ceramic Insulation Coating

Application Instructions

DCU2050 FL601. DELTA Graffiti Resistant Clearcoat

PRODUCTION SEQUENCES OF PAINT SHOP

Case Study No. 15 UV-Cured Coatings Loewenstein, Inc. Pompano Beach, FL

SLS Etch Primer. 300g aerosol, 250ml tin, 500ml tin, 1L tin, 4L tin

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

Pot Belly Black. Overview. Suitable Surfaces

APPLICATION INSTRUCTIONS FOR MASCOAT SOUND CONTROL-dB

STOP ACRYLIC TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

3 Water Based Foam Adhesive

Roofing Adhesive SARNACOL 2172 Spray

Surface Preparation For Coatings

PRODUCT DATA KEFA AIRLESS 8125 and 8125B

ENGINEERED QUARTZ SINK Installation & Care Instructions

INSTALLATION AND CARE GUIDE MARCO VANITY FRAME BASE & SINKTOP E E E E052463

ad notam MOUNTING SYSTEM FOR RECESSED IN-WALL APPLICATION

1542 Jefferson Street, Teaneck NJ TEL: FAX:

Floor Care Methodization

Photolithography SOPs

E-Chef Hot Food Table Installation and Operation Manual

Floor Maintenance Pads

SANITATION CITATION TRAINING GUIDE

ACRYLIC PEDESTAL TUB

Guideline for Gelcoat Repair

CONTAMINANT FREE REFINISHING

HP PVC-free Durable Wall Paper

NeverStrip Color. Color Product Data Sheet

SPEEDY CARBONIUM TECHNICAL DATA SHEET

Muskogee Public Schools Custodial Procedures for Floor Care

Industrial Science Seminar

For routine maintenance of polished granite installations with a cleaner and protector:

CONTAMINANT FREE REFINISHING

STOP RESIN TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

Reference : S /27/01 Page 1 of 12

- 2 - IMPORTANT SAFETY REMINDERS IT IS IMPORTANT THAT YOU:

THE COMPACT CENTRIFUGE: OPERATOR 1

FREESTANDING ACRYLIC TUB INSTRUCTION MANUAL

Product Data Sheet. NeverStrip UV Resilient. Matte. A NeverStrip Instant Film Coating. UV Resilient Matte

Introduction The following illustrated instructions are a generic guide to the internal installation of Safety and Security Films.

Chemical Colour Codes

Timeless Classics. Designed to inspire the interior designer within you

SELF-CONTAINED FLAKER

HEDSON TECHNOLOGIES AUTOMECHANIKA 2008

PANCRETE PAN IN A CAN

Nokia Holder Easy Mount HH-20 and CR-114/115

Maitenance guide N 3. for oiled DI LEGNO parquet floors white finishing

ACRYLIC CLAWFOOT TUB

Nokia Holder Easy Mount HH-20 and CR-120

CUSTODIAL TRAINING GUIDE RESTROOM CARE

Reliability is a beautiful thing TM CUBELET ICE DISPENSER DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF INSTRUCTION MANUAL

FAQ s ABOUT TOPZERO STAINLESS STEEL SINKS: >What type of stainless steel does TopZero use?

3M Stamark Low VOC Surface Preparation Adhesive SPA60 Spray Application Instructions for Bulk Liquid for Longitudinal Pavement Marking Tapes

Write Walls Dry Erase Specification Data (Section 09720)

FLOOR CARE. Avmor s Floor Care Training Guide

Wood Floor Care. Method Bulletin Hi-Trac Pro-Floor Extreme

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

TANDUS CENTIVA CLEAN GREEN MAINTENANCE PRODUCTS CENTI Clean

HARMONI GENERAL RUBBER FACTS

ISSUED: FEB. 23, 1998 REVISED: OCT. 15, 1999 HOSHIZAKI MODULAR FLAKER MODEL F-450MAF(-C)

3 Scotch Mini-Weld Adhesive System User s Manual

Hoshizaki America, Inc.

MIMAKI ENGINEERING CO., LTD.

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout


CARE & MAINTENANCE ALUMINIUM WINDOW & DOOR SYSTEMS BY

Care and Maintenance Guide

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

FRYMASTER TCF. Chicken Fryer

INSTRUCTIONS AND WARRANTY

MaxCel PLANT GROWTH REGULATOR COMMERCIAL CAUTION KEEP OUT OF REACH OF CHILDREN READ THE LABEL BEFORE USING

Page 1 of 18. Part# /5/2013

High Performance Mold Maintenance Products CLEANERS RUST PREVENTATIVES MOLD RELEASES GREASES COATINGS

Recommended Floor Care Procedures

Inhibitaur. Rust Blocker. Use On: Snow & Ice Removal Equipment Highway & Off-Road Trucks Heavy Equipment Fleet Vehicles

NeverStrip Gloss. Gloss Product Data Sheet

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80002

TH ANK YOU FOR CH OOS ING H BF

LINOLEUM FLOOR CARE MANUAL

Equipment Specifications / Applications Guidelines

PRO 2000i LOW LEVEL DEPOSITOR

WITH OMRON E5CC CONTROL

Cleaning the internal optics surfaces

MERIDIAN MODEL# 3793

PERFORM Operating Document. General maintenance of Stoves, Fridges and Pots and Pans in the Nutrition Suite

2003 Saturn ION. Some customers may comment on moisture leaking onto the floor of the vehicle when the A/C system is running.

ENGLISH Parcan 16 GU10D socket V1

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

REGULAR MAINTENANCE AND CARE

CAST IRON CLAWFOOT TUB

ACIDS & ACID CLEANERS

Introducing Solar Identification Labels

Transcription:

Pretreatment / Rinsing Product Description North America Technical Data Sheet # The MetaAlloy CI system consists of a Pre-treatment and Neutralizer rinse: 1. MetaAlloy CI Treatment is a water based chrome-free surface pre-treatment that gives superior adhesion, improved paint flexibility and advances corrosion protection under painted surfaces. 2. MetaAlloy CI Neutralizer Rinse is a water based solution specifically designed for rinsing and preparing of repairs that are to be cleaned for refinishing while also providing corrosion protection on painted surfaces. Safety Considerations Use suitable personal protection. Refer to the product Material Safety Data Sheet (MSDS) for more complete safety information. Mixing Each product is used as is. HVLP or Compliant Spray-Gun Set-Up: Spray guns are not required. Application Both products are applied using spray bottles. Flash Between Coats at 70 F (20 C) MetaAlloy CI Treatment should not be allowed to dry. Flash Before Force Drying at 70 F (20 C) No force drying recommended MetaAlloy CI Neutralizer Rinse should be air dried completely. Air Drying at 70 F (20 C) Following rinse application, allow surface to air dry completely without using towels. MetaAlloy CI must be applied over pretreated surface within 24 hours or the pre-treatment / rinse process must be repeated. Force Drying at 140 F (60 C) No force drying is recommended. Infra-Red No infra-red drying is recommended. 1 / 6

Re-Coatable With: MetaAlloy CI Aerosol Aerosol Description Following the pretreatment and cleaning process the MetaAlloy CI should be used. 3. MetaAlloy CI is a 2K chrome-free aerosol epoxy primer. Safety Considerations Use suitable personal protection. AkzoNobel Car Refinishes recommends the use of a fresh air supply respirator. Refer to the product Material Safety Data Sheet (MSDS) for more complete safety information. Mixing The MetaAlloy CI Aerosol needs activation followed by 2-3 minutes of vigorous shaking. A 15 minute induction time is then required prior to use. Application Apply a single uniform wet coat. Air Drying at 70 F (20 C) Minimum of 2.5 hours prior to Surfacer / Sealer application. Maximum of 48 hours prior to Surfacer / Sealer application. Force Drying at 140 F (60 C) No force drying is recommended. Infra-Red The use of infra-red drying is not recommended. Re-Coatable With: Sikkens Colorbuild Plus Sikkens Colorbuild Plus 250 2 / 6

Description The is a chrome-free, corrosion inhibiting system for application and repair of aluminum. These products offer excellent corrosion protection and optimized system adhesion. The products supplied as part of the are VOC complaint with current regulations for United States, Canada and Mexico. Suitable Substrates Prepped aluminum surfaces. Substrate Preparation Pre-Cleaning Clean all surfaces with Sikkens M600 Surface Cleaner or Sikkens AutoPrep Ultra Prep Surface Cleaner. MetaAlloy CI Treatment Application Liberally apply MetaAlloy CI Treatment on areas to be repaired. Work in section of 6-12 inches DO NOT ALLOW MATERIAL TO DRY Completely scrub with red Scotch Brite pad such as Scotch-Brite Pad No 07447. MetaAlloy CI Neutralizer Rinse Application Following the MetaAlloy CI Treatment application and scuffing, flush surface with MetaAlloy CI Neutralizer Rinse. Rinse should sheet on the surface. If it beads, repeat the cleaning process. o The rinse waste created is non-hazardous and can be disposed of as such. Allow the surface to air dry completely prior to MetaAlloy CI application. o Do not use towels. o Do not force dry. o Do not use a solvent wipe after process is completed. Prior to painting, if there is dust on the surface, remove with water dampened lint free cloth. MetaAlloy CI must be applied within 24 hours of the pretreatment process or the entire process must be repeated. Failure to repeat the process could result in poor system performance. MetaAlloy CI Aerosol Activation To Activate Remove the red button from the over cap and attach to the plastic pin at the bottom of the aerosol. Place aerosol upright on a flat surface and push down to break the inner seal. A pop must be heard inside of the container to indicate the seal is broken. 3 / 6

Remove the red button from the bottom of the aerosol. The pin should move freely. Turn the can upside down. Shake vigorously for 2-3 minutes after activation for thoroughly mixing. IMPORTANT A 15 MINUTE INDUCTION TIME IS REQUIRED PRIOR TO APPLICATION. Pot-Life when Activated Product Mix MetaAlloy CI 70 F (20 C) 4 hours Application Apply a single flowing coat. The material delivery is faster than a normal aerosol and the fan is larger. Film Thickness Using Suitable Application 1 Coat will achieve a dry film thickness of 0.6 1.0 mils (15 25μm). Drying / Curing Time Drying times are stated a recommended application method, film thickness and object temperature. 70 F (20 C) 95 F (35 C) 120 F (49 C) 140 F (60 C) Recoatable Min - 2.5 hours Max 48 hours Not recommended Not recommended Not recommended IR curing is not recommended. 4 / 6

Recoating Sanding / De-Nibbing MetaAlloy CI must be recoated with Colorbuild Plus or Colorbuild Plus 250 Sealer or Surfacer followed by Sikkens Basecoat and Clearcoat. MetaAlloy CI primer must be allowed 2.5 hours to dry prior to sealer application but no longer than 48 hours. No sanding of the MetaAlloy CI is needed prior to Sealer / Surfacer application. If during the sanding of Colorbuild Plus Surfacer or Colorbuild Plus 250 Surfacer break through to the substrate occurs, reapply MetaAlloy CI and repeat recoat process. Cleaning of Equipment After use, invert the can and spray until clear to clean the nozzle. If aerosol is left standing, shake vigorously prior to each use. Theoretical Coverage Theoretical coverage is dependent of many factors. These may include; the shape of the object, surface smoothness, application technique and other application variables among others. 44 square feet per aerosol can at 1.0 mils dry film thickness and 100% transfer efficiency. VOC / Regulatory Information The products supplied as part of the are VOC complaint with current regulations for United States, Canada and Mexico. Product Storage Stock unopened or used products in approved closed containers with proper labeling. Store in moderate temperatures between 40 F - 95 F (5 C 35 C). Avoid too much temperature fluctuation. Optimum storage temperature is approximately 70 F (21 C). If pretreatment or rinse arrives in a frozen state, allow 24 hours to thaw and use. The product integrity and performance will not be affected. 5 / 6

527894 MetaAlloy CI Treatment Prefill (Quart) 36 months 527655 MetaAlloy CI Neutralizer Rinse (Quart) 36 months 527895 MetaAlloy CI Neutralizer Rinse Prefill (Quart) 36 months 527856 MetaAlloy CI (400mL Aerosol) 12 months 527924 MetaAlloy CI Repair Kit (3 Piece Box) AkzoNobel Car Refinishes Inc, North America Address: 1845 Maxwell Street Troy, MI USA Telephone: 800.618.1010 IMPORTANT NOTE The information in this data sheet is not intended to be exhaustive and is based on the present state of our knowledge and on current laws: any person using the product for any purpose other than that specifically recommended in the technical data sheet without first obtaining written confirmation from us as to the suitability of the product for the intended purpose does so at his own risk. It is always the responsibility of the user to take all necessary steps to fulfill the demands set out in the local rules and legislation. Always read the Material Data Sheet and the Technical Data Sheet for this product if available. All advice we give or any statement made about the product by us (whether in this data sheet or otherwise) is correct to the best of our knowledge but we have no control over the quality or the condition of the substrate or the many factors affecting the use and application of the product. Therefore, unless we specifically agree in writing otherwise, we do not accept any liability whatsoever for the performance of the product or for any loss or damage arising out of the use of the product. All products supplied and technical advices given are subject to our standard terms and conditions of sale. You should request a copy of this document and review it carefully. The information contained in this data sheet is subject to modification from time to time in the light of experience and our policy of continuous development. It is the user's responsibility to verify that this data sheet is current prior to using the product. Coatings brand names mentioned in this data sheet are trademarks of or are licensed to AkzoNobel. Head Office AkzoNobel Car Refinishes B.V., PO Box 3 2170 BA Sassenheim, The Netherlands. www.sikkenscr.com 6 / 6