FEATURES Model MX 4 gas detection control panel Dimensions (wall-mounted version) 7 x 99 x 9 mm (4.6 x.8 x 4. inches) Dimensions (rack) 9", 4U ; 48.8 x 77 x 9. mm (9. x 7 x 7.6 inches) Ingress protection IP (wall-mounted), IP (rack) Cable entries (wall-mounted version) M6 cable glands, 4 to 8 mm² (8 to AWG) outer diameter cable 6 M cable glands, 6 to mm² (7 to 9 AWG) outer diameter cable Display LCD back-lit display + smart keys Display in video inverse in case of fault Customizable by user (display to 6 channels simultaneously, fixed or scrolling, on events...) Bar graph with alarm threshold Visual indicators 7 LEDs per line LED fault indicator LED fault indicator Buttons smart keys audible alarm accept/reset button Operating use Operating temperature - C to + C Storage temperature - C to + C Humidity to 9% RH Power -4 Vac -6 Hz or -8 Vdc, W max Battery Embedded back up power supply in option (.6 Ah) Consumption ma min (without module) Measurement lines Digital lines8 maximum RS-48 communication, proprietary protocol, 96 Baud twisted shielded-pair cable Analog channels8 maximum - ma analog signal input (4 to ma reserved for measurement) Ohm load resistance or -core shielded cable Voltage (typical) to 8Vdc Maximum current output per line ma Maximum current output in total.4 A permanent (. A intermittently) Alarms Per channel alarm levels (A, A, A, Overscale, Underscale) + Fault Non-ambiguity reading option for combustible gases monitoring Programmable thresholds On instantenous ou averaged values, rising or falling alarms, manual or automatic acknowledgement On-board relays fully programmable alarm relays fault relay (non-configurable) Dry contact relay DPCO relays with contact rating of Vca A (inductive) Digital outputs RS-48 Modbus RTU serial link Approvals EMC According to EN7 ATEX EN7 and metrological performances according to EN679-9- Low Voltage Directive According to EN6 CSAPending
Controller presentation The MX 4 is an analog and digital controller designed for the continuous measurement and control of the gases present in the atmosphere and for 4- ma or digital contact signal. Large graphic display Smart keys make embedded menus simple to use Front panel LEDs allow a quick and basic overview of the installation. MX 4 manages both digital lines and analog channels, and covers all needs for a wide variety of applications. The MX 4 digital technology allows up to detectors to be distributed on 8 lines for increased cost savings. 4 Internal battery Strobe and horn Power supply 4 6 on-board relays Removable terminals
In 4-channel display GRAPHIC DISPLAY -% LEL methane 6 Previous Next detector detector 4 LM CH4 7 8h avg Detector OK At least line is OFF Menu 7 See 4 detectors Curve Compressor Compressor previous 7CH4 Next CH4 Menu Turbine Turbine See 6 detectors CH4 7CH4 Measurement range, gas and detector tag Detector address Current value with unit and detected gas 4 Averaged value on the last 8 hours Bar graph with alarm thresholds 6 Detector status (OK, OFF, fault) 7 MX 4 status information Calibration Curve Simplified procedure that enables time savings (i.e. nonintrusive and one man calibration). -% LEL methane OLCT LM Detector Zoom Zero Span End Gas: 4 4:4: Zoom - 7// Zoom + Calibration curve Cursors for span settings Measured value 4 Calibration gas value Detector selection, zeroing and spanning Alarm mode Up to 6 detectors can be displayed simultaneously Data-logging The MX 4 can store up to alarm events, fault events and system events. previous Next Gas alarms 4 64/64 AL AL AL AL Last Delete Detector tag Event Date and time of events appearance or clearance 4 Page number (up to 64 s) Programming Software for the COM4 Compressor A- Level VOTING / Level Level Level 4 ON ON OFF OFF Level ESC 8::9 8::9 8:: 8:: Alarm -% LEL methane CH4 4 88 8h: avg Normal Previous Next detector detector 4 Detector OK Menu See 4 detectors LM AL Curve Reverse video in alarm conditions for immediate identification of the concerned detector. Current value with unit and detected gas Averaged value on the last 8 hours Detector status (OK, OFF, fault) MX 4 status information Detector in alarm Compressor A- Alarm Alarm Compressor A- Compressor A- Compressor A- NAND AND N NAND VOTING OK Cancel Simple relay programming Up to embedded functions:, AND, N, NAND, VOTING Several timers available 4 Advanced management of audible alarms (acknowledgment, reactivation, evacuation) Siren www.oldhamgas.com
GAS DETECTION CONTROL PANEL Modules Different modules can be connected to the controller: 4 or 8-relay module 4 or 8-programmablerelay module can be located closer to the actuators for cost savings. 6-logic-input module Addressable module of 6 logic input for recovery of digital information such as fire or intrusion alarms, emergency stop, limit switch activation, etc. 8-analog-input module Configuration example This module enables standard analog transmitters (gas or flame detectors for instance) to be connected on a digital line for cost savings. 4-analog-output module Addressable 4- analogoutput module which delivers 4 analog 4-mA signal outputs (detector output copy, min, max, average of a group of detectors) for connection to a datalogger, a PLC, a Building Management System (BMS), etc.
Our fixed detector range OLCT OLCT N CTX OLCT itrans OLCT 8 OLCT 6 OLCT 6 / OLCT IR OLCT IR Safeye Sharpeye OUR MISSION Preserving human life, above and below the earth. Delivering highest quality, best customer service Every transaction, every time www.oldhamgas.com AMERICAS Phone: +-4-788-4 Fax: +-4-788-8 info@indsci.com ASIA PACIFIC Phone: +6-66-777 Fax: +6-66-7787 info@ap.indsci.com EUROPE Phone: +---6-8-8 Fax: +---6-8- info@oldhamgas.com REV 8 Ref. MX4_Lit_EN_v4