Modelling of divided wall column

Similar documents
Capital Cost Reduction by the Use of Divided Wall Distillation Column

Shortcut Model for Predicting Refrigeration Cycle Performance

Practical Approach to DWC Design & Optimization Plant Basic Engineering Team

MASS TRANSFER EQUIPMENT DESIGN CONSIDERATIONS FOR CRYOGENIC ABSORBERS, DEMETHANIZERS AND DEETHANIZERS

REFRIGERATION CYCLES

REFRIGERATION CYCLES

Application of a divided wall column for gas separation in floating liquefied natural gas plant

KBC Petro-SIM Design Tools Integrated Equipment Operations. Al Shelton - KBC

Evaluation of Sorbents at Elevated Temperatures for Downhole Application

A New Graphical Approach for Heat Exchanger Network Retrofit Considering Capital and Utility Costs

Identification of the Most Effective Heat Exchanger for Waste Heat Recovery

Minimising Energy Use in Milk Powder Production using Process Integration Techniques

Process Simulation and Optimization of Cryogenic Operations Using Multi-Stream Brazed Aluminum Exchangers

Chapter 5 Heat-transfer Equipment

In order to be useful, many substances must be available in pure form.

Economic Analysis Based on Energy and Water Consumptions between Air-Cooling and Water-Cooling

Effect of the Outlet Air Reuse on Thermal Efficiency of a Pilot Plant Spray Dryer with Rotary Atomizer

Oil Stabilization Optimization

International Association of Certified Practicing Engineers

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

TROUBLESHOOT PACKING MALDISTRIBUTION UPSET PART 2: BOILING AND FLASHING IN PACKED TOWER DISTRIBUTORS

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

5 Separation Processes

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Chemical engineering range - 11/01 MULTI-FUNCTION DISTILLATION DVI/6000. Version presented DVI/6000 PIGNAT S.A.S. Subject to technical modifications

Modelling the Performance of a Diffusion Absorption Refrigeration System

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

J. LINES, Graham Corp., Batavia, New York

Experimental study and steady-state modelling of a Commercial diffusion-absorption refrigerator

Innovative Hybrid Heat Pump for Dryer Process Integration

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Limiting Distances for Flame Merging of Multiple n-heptane and Di-tert-Butyl Peroxide Pool Fires

New Software for Simulation of Drying and Evaporation Systems

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Efficiency of Non-Azeotropic Refrigerant Cycle

Study of R161 Refrigerant for Residential Airconditioning

Development of Rotating Tray Dryer and Study of the Hot Air Flow Pattern with Computational Fluid Dynamics

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

ENERGY OPTIMIZATION IN THE MAA GAS PROCESSING FACILITIES

CHAPTER 1 INTRODUCTION

Modelling of End-use Electricity Consumption and Saving Potential in Household Sector in Northern Thailand

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

A Novel Freeze Drying Process by Using Self-Heat Recuperation Technology

The Effect of Condenserfluid Quality on the Performance of a Vapour Compression Refrigeration Cycle A Simulation Model Approach

2007 KBC Advanced Technologies plc. All Rights Reserved.

Numerical Analysis of Heat Transfer in Radiant Section of Fired Heater with Realistic Imperfect Geometry of Tube Coil

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

OPERATION OF A BATCH DISTILLATION COLUMN WITH A MIDDLE VESSEL: EXPERIMENTAL RESULTS FOR THE SEPARATION OF ZEOTROPIC AND AZEOTROPIC MIXTURES

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Optimization of Cooler Networks Considering Different Types of Cooling

VACUUM TOWER WASH SECTION DESIGN: MYTH AND REALITY

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Compression of Fins pipe and simple Heat pipe Using CFD

Vacuum Booster for Distillation Process

Computational Approach for Energy Intensity Reduction of Professional Laundry Care Process

Modeling And Testing Of R23/R134a Mixed Refrigerant System With Water Cooled Separator For Low Temperature Refrigeration

Experimental Evaluation of a Gas Engine Driven Heat Pump Incorporated with Heat Recovery Subsystems for Water Heating Applications

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

DELAYED COKER UNIT (DCU)

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Dynamic Models of a Home Refrigerator

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Performance investigation of Air-conditioning system using ejector as expansion device

Experimental investigation on the performance of air conditioner using R32 Refrigerant

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

1.1. SCOPE OF THE WORK:

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

MODELING OF THE SINGLE COIL, TWIN FAN AIR-CONDITIONING SYSTEM IN ENERGYPLUS

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Effect of different air velocities on convective thin-layer drying of alfalfa for livestock feeding

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

OIL AND GAS INDUSTRY

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Transcription:

CHEMICAL ENGINEERING TRANSACTIONS Volume 21, 2010 Editor J. J. Klemeš, H. L. Lam, P. S. Varbanov Copyright 2010, AIDIC Servizi S.r.l., ISBN 978-88-95608-05-1 ISSN 1974-9791 DOI: 10.3303/CET1021012 67 Modelling of divided wall column László Szabó, Miklós Balaton*, Sándor Németh, Ferenc Szeifert Department of Process Engineering University of Pannonia, Egyetem Str. 10, H-8200 Veszprém, Hungary, szabol@fmt.uni-pannon.hu The rectification is the most often used fluid separation technology. The improvement of the distillation equipment and process is significant (Haddad and Manley, 2008) because the rectification has relatively low energy efficiency. In practice, the aim is the separation of the multi-component mixture. This task can be solved with a number of columns depending how many components there are or one column with side product(s). This paper focuses on how to find a better structure with minimal energy consumption. The divided wall column (DWC) system is a promising energy-saving alternative for separating multi-component mixtures (Serra et al, 1999). The innovation of this equipment is a wall which divides the space in of the tower so the feed and the side stream-product zones are separated. This wall prevents contamination of the side stream by the feed stream. The dividing wall column has greater efficiency than common column sequence (Hernández et al V, 2006). The conventional columns with side stream are also convertible to DWC. In this paper different constructions of the DWC were investigated with simulation experiments. The structure of the column was implemented in Aspen Plus TM simulator using the Radfrac unit of the software. The effects of the main parameters of the divided wall column like split ratio of the liquid and vapor stream, height of the wall, vertical position of wall, and the heat transfer of the wall were analyzed. 1. Separation task Separation of a ternary-mixture (benzene, toluene, o-xylene) was investigated. Normal boiling temperature of the components can be found in the Table 1. The mass flow of the feed stream was 90 kg/h. The mass fractions of the components were the following: 0.333 for the benzene, 0.333 for the toluene, 0.333 for the o-xylene. The boiling points of the components are far from one other, and there is no azeotrope formation. The 99% purity of the products was required. Table 1:Boiling point of the components Boiling point ( C) Feed concentration (kg/kg) Benzene 80.1 0.33 Toluene 112.1 0.33 o-xylene 144.4 0.33 Please cite this article as: Szabó L., Balaton M. G., Németh S. and Szeifert F., (2010), Modelling of divided wall column, Chemical Engineering Transactions, 21, 67-72 DOI: 10.3303/CET1021012

68 2. Implementation of the dividing wall column In chemical industry flowsheeting simulators are used for design and research work. With these simulators the user can define the structure of the technology as a flowsheet. The blocks (units) represent the main equipments, and the connect lines show the streams. The simulator also includes the models of the equipments. The model of the DWC is not included in any flowsheeting simulators. To solve that problem the column was divided in four parts (Figure 1) and each part was simulated using an existing model of the software (Adrian et al, 2004). The parts are the following: the top partition (above the divider wall, with condenser and reflux drum), the bottom partition (under the wall, with reboiler), and the feed and the product partition separated by the wall. The four parts are performed with four rigorous (Radfrac) units. Heat transfer between the feed and product zone was also calculated. The driving force of the heat transfer is the temperature difference between the two zones. The product of the heat transfer coefficient and the surface of the heat transfer were defined as a model parameter. The dimension of the DWC are equal to the dimension of a column with sidestream which can solve the separation task. The number of stages in the column is 23. There are the feed and the side stream in the middle of the column (the 12th stage from the top). The sum of the surfaces of the feed and side-product partition is equal to the surface of the top and bottom partitions. Top part Benzene Feed part Product part Toluene Bottom part o-xylene Figure 1: Structure of the simulator

Reboiler duty (kw) 69 3. User interface of the simulation A user interface was created for the simulation, because the parameter-determination of the four blocks was difficult. The Aspen Plus TM was connected to Microsoft Excel in order to have an easy-to-use graphical user interface. The user may set the parameters of the DWC in an Excel worksheet. The Excel calculates the parameters of the four partitions, and sends the data for the Aspen Plus TM. The simulation software sends back the results data of DWC. The results can be shown in an Excel worksheet. 4. Vertical position of the wall It was investigated how the heat duty of the reboiler was changing with the vertical position of the wall. The length of the wall was equal to the height of nine trays tall. The number of stages had not been changed, and the numbers of stages in the feed and product partitions were equal. The central position (when stage number of the bottom and the top partition was equal) was marked zero in the Figure 2. In the negative range the top partition has more stages than the bottom partition. The surfaces of the feed and product zone were the same. As Figure 2 shows, the energy consumption is the lowest when the top partition has the same number of stages as the bottom partition. The asymmetry increases the energy consumption. One of its reasons may be that the components have the same mass fraction in the feed. 60 55 50 45 40 35 30 25 20-3 -2-1 0 1 2 3 Relative position (midle of the column) Figure 2: Effect of the vertical wall position 5. Height of the wall It was investigated how the heat duty of the reboiler was changing with the height of the wall. The central vertical position wall was analyzed from the previous part. The surfaces of the feed and product zones were the same. As Figure 3 shows, the energy consumption is the lowest when the length of the wall was equal to the height of nine trays.

Reboiler duty (kw) 70 60 55 50 45 40 35 30 25 20 5 6 7 8 9 10 11 12 13 Height of the wall (tray) Figure 3: Effect of the height of the wall From the five to the nine units tall wall the energy consumption is decreasing higher wall than that slightly increases the reboiler heat duty. The effect of the wall is not significant when the length of the wall was lower than nine units tall. If the wall is higher than nine units, the number of stages in the top and the bottom partitions decreases. That is why the reboiler duty and the reflux increase for suitable separation. 6. Split ratio It was investigated how the heat duty of the reboiler is changing with the split ratio. The split ratio means the ratio of the surface of the feed and product zones, and the proportion of the vapor and liquid phases under and above the wall. The split ratio equals to the quotient of the surface of the feed zone and the all the surface. The height of the investigated wall was nine unit tall and the vertical position of the wall was central. The result of the investigation is shown in Figure 4Figure. At 50% the minimum energy consumption is minimal.

Reboiler duty(kw) Reboiler duty (kw) 71 70 65 60 55 50 45 40 35 30 25 20 0 10 20 30 40 50 60 70 80 90 100 Splitting ratio (%) Figure 4: Effect of splitting ratio 7. Comparison of the DWC and column with side stream product In the previous sections the optimal parameter combination of the DWC was studied. In this section, this construction is compared with a column with sidestream product which can solve the separation task. The reboiler heat duties of the equipments were compared in a range of the feed rate. The results are shown in Figure 5. It can be seen that the DWC is better in terms of reboiler heat duty than the classical construction. 700 600 500 Divided wall column Column with side product 400 300 200 100 0 50 100 150 200 250 300 Feed rate (kg/h) Figure 5: Comparison of the DWC with the side stream column

72 8. Conclusion Different constructions of the DWC were investigated with simulation experiments. The structure of the column was implemented in Aspen Plus TM simulator using the rigorous (Radfrac) unit of the software. The column was divided in four parts. These parts were implemented with different blocks. The heat transfer between the feed and product zone was also calculated. User interface of the simulation was also created. The effects of the main parameters of the divided wall column like split ratio, height of the wall, vertical position of wall were analyzed. The optimal parameter combination of the DWC was determined. This construction was compared with column with sidestream product which can solve the separation task. In this case the DWC is better than customary construction. Acknowledgements The financial support from the TAMOP-4.2.2-08/1/2008-0018 (Livable environment and healthier people Bioinnovation and Green Technology research at the University of Pannonia) project is gratefully acknowledged. László Szabó is grateful for the support of the PhD Fellowship of the MOL Plc References Haddad, H.N. and Manley, D.B., 2008, Improve crude oil fractionation by distributed distillation, Hydrocarbon Processing, 87; numb 5, 93-110 Serra, M., Espun, A., and Puigjaner, L., 1999, Control and optimization of the divided wall column, Chemical Engineering and Processing, 38, 549 562 Adrian, T., Schoenmakers, H. and Boll, M., 2004, Model predictive control of integrated unit operations: Control of a divided wall column, Chemical Engineering and Processing, 43, 347 355 Hernández, S., Segovia-Hernández, J.G. and Rico-Ramírez, V., 2006, Thermodynamically equivalent distillation schemes to the Petlyuk column for ternary mixtures, Energy, 31, 1840 1847