Labconco Small Stoppering Chamber

Similar documents
Open Kjeldahl Apparatus INSTRUCTION MANUAL

Hooded Kjeldahl Apparatus

Models Goldfisch Fat Extraction Apparatus

RapidStill II MODEL INSTRUCTION MANUAL. Product designs are subject to change without notice REV. B / ECO A631

RAPID DIGESTORS. Model Rapid Digestor-25 without digestion tubes Model Rapid Digestor - 4 without digestion tubes INSTRUCTION MANUAL

CentriVap Centrifugal Concentrators and Cold Traps

User s Manual. FreeZone 6, 12 and 18 Liter Freeze Dry Systems

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

User s Manual. FreeZone 1 Liter Benchtop Freeze Dry Systems. Models

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

CLS-1450 Series Spinner Flask Instruction Manual

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

92831 TEL: (714) FAX:

OPERATOR S MANUAL DEAD AIR WORKSTATION. AC600 Series Dead Air Box & Timed UV Light with UVTect Controller

Labconco XPress Laboratory Equipment Where You Need It, When You Need It

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

FreeZone 2.5 Liter Benchtop Freeze Dryers

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

Humidistat-Thermostat

Professional Warming Drawer and Warming Drawer Cabinet

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

M Series Fan Filter Units

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

IQ/OQ Protocol Installation Qualification/ Operation Qualification

TL-105 COLUMN HEATER

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

MACHO POP Instruction Manual Model 2554EX, 2554BCX

MIGHTY PRO 1/4 HP CHILLER

Model # VWK-2 INSTRUCTION MANUAL

A2Z Ozone, Inc. PRODUCT MANUAL

Air Pump Up to 800 gallons

MN908 No. 282C Replaces 282B LB7013

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

User s Manual. FreeZone 2.5 Liter Freeze Dry Systems

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

Ozone + UV Sanitation

Operation Maintenance. Mobile Oil Caddy

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

THE BOARD 100IB / 200IB HOME IRONING BOARD INSTRUCTION MANUAL

InstructIon Manual KrEs EQuIPMEnt stands

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

CentriVap DNA Systems. Models

Owner s Manual. Terpene Trap CF 1000

AQUA LOGIC S CORONA SERIES UV STERILIZERS

Pressurized Filter Up to 1250 gallons

INSTRUCTIONS FOR OPERATION AND CARE OF

Field Top Mounted Condensing Unit

TrueClean ToteCleaner

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

Quick-Start Operating Guide Document No Series 200 Glove Box Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

Comfort Series Instant Hot Water System

REMOTE MOBILE SECURITY SYSTEM USER MANUAL

Instruction Manual GP110 GelPump

MODEL HBX-1 P/N 3G59332

Freeze Dry Systems and Accessories

Operation Manual and Parts Directory

Installation & Operation Manual Ice Cream Freezers

USER S OPERATING AND INSTRUCTION MANUAL

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Freeze Dry Systems and Accessories

TECHNICAL BULLETIN ACCESSORY INFORMATION NU-984 FORMALIN/AMMONIA VAPORIZER


Instruction Manual. Nacho Cheese Dispenser and Warmer

Q Model AuCS A Accessory

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Part No Revised Nov Lil Max. Instruction Manual Model #2389, 2389EX

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

USER MANUAL IMPORTANT

Installation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets

ELECTRIC GRIDDLES TMGE24, TMGE36, TMGE48. Installation and Operation Instructions 2M-Z12971 Rev. - Oct. 1, 2009 MODEL TMGE36 IL1880

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

M1200 Series Limited Warranty Dependability Promise

VACUUM LOADERS GSL Series

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

TrueClean ToteCleaner

!"" #$% "!&' ( ( ) *

Blueair EC010. User Manual

WET/DRY VACUUMS POLYETHYLENE, POLYPROPYLENE & STEEL

Steam Distribution. Installation Manual. Includes installation instructions for steam distributions ASD/BSD/CSD/RSD/SSD.

COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

Volterra. Owner s Manual WARNING WARNING WARNING FOR OUTDOOR USE ONLY CAUTION: OUTDOOR FIREPIT TABLE

SANI-VAC MODEL #750 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION

Part No Revised April Pop Maxx. Instruction Manual Model #2552, #2552C, #2552EX, #2552XJ

Immersion Cell (with Small Volume Vessel) User Guide Rev. C

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Retro Flip Alarm Clock MODEL: CH1200/1/2

Transcription:

LABCONCO CORPORATION 8811 Prospect Ave, Kansas City, MO 64132 (816) 333-8811, Fax (816) 363-0130, (800) 821-5525 Labconco Small Stoppering Chamber 7569000 Introduction- The Small Stoppering Chamber is ideal for Lyophilizing sample in small serum vials with split stoppers. Once the samples are lyophilized the vials can then be stoppered while still under vacuum. The chamber comes complete with PVC tubing and ½ adapter to connect directly to the ports of Labconco s Freeze Dry Chambers. Installation of Small Chamber To Freeze Dry Chamber (Refer to Figure 1) 1. Place one end of the PVC Tubing over the ½ fitting on the side of the chamber and secure with a clamp. 2. Insert the ½ Stainless Steel Adapter approximately 1 into the other end of the PVC Tubing and secure with a clamp. 3. Insert the open end of the ½ adapter into one of the Ports on the Freeze Dryers Chamber. 4. Position the switch on the Small Stoppering Chamber to the CLOSE position. 5. The Small Stoppering Chamber is now ready to use. Figure 1 Labconco Instruction Sheet 1049200, Rev -, ECO H250 01/13 1 of 5

Set-up 1. The Small Stoppering Chamber has a stoppering travel distance of ½ (12.7mm), it can accommodate vials that range in height from 1.38 (35mm) to 2.48 (63mm) tall by using zero, one, or two of the spacers which are provided. Labconco offers 6 sizes of serum vials that can be used in the Small Stoppering Chamber. See the chart below to determine the number of spacers required for specific vials and the total number of vials the chamber will hold of each size. Size Part no. Number of Bottles/run Spacers Required Vial Dimensions Diameter x Height Split Stopper Part No. Alum Seal Part No. 2 ml 7575000 48 2 18mm x 35mm 7576000 7577000 3ml 7575200 43 2 17mm x 28mm 7576000 7577000 5 ml 7573000 21 1 23mm x 47mm 7576200 7577100 10 ml 7573200 19 1 25mm x 54mm 7576200 7577100 20 ml 7573400 11 0 32mm x 58mm 7576200 7577100 30 ml 7573600 8 0 37mm x 63mm 7676200 7577100 2. Once the vial size is selected place a stoppered vial in the chamber with the tray and correct number of spacers. The top of the stopper should be located between the two scribed lines marked on the inside diameter of the clear chamber. If the vial is lower than the bottom line, the Stoppering device will not stopper fully. If the vial is higher than the top line the lid will prematurely stopper the vials when it is placed on top of the chamber. Caution: only one size (height) vial can be Lyophilized and stoppered during the same run. Figure 2 Labconco Instruction Sheet 1049200, Rev -, ECO H250 01/13 2 of 5

Freeze Dry 1. The samples should be pre-frozen in the vials with the stoppers installed in the unstoppered position. A tray is provided so that the vials can be loaded and then placed in the freezer. Once the samples are frozen and the Freeze Dryer is ready, the tray can quickly be transferred to the Small Stoppering Chamber for Lyophilizing. 2. Start the Freeze Dry System as directed in the owner s manual. When the Freeze Dry system is started all of the Freeze Dry Ports should be in the vent position. (The bevel on the knob should point away from the sample port). This will allow vacuum to build up in the system. 3. When the freeze dry system is ready, make sure the switch on the Small Stoppering Chamber in the CLOSE position. Place the tray with the frozen samples in the Small Stoppering Chamber with the proper spacers. Make sure the Clear Chamber and Clear Lid are centered and resting on their o-ring seals. Apply vacuum to the sample by rotating the knob on the Freeze Dry Port to the vacuum position. (The bevel on the knob should be positioned toward the sample port). 4. The vacuum should pull the Clear Chamber and Clear Lid together to seal the system. Check the Vacuum after some time to confirm there are no vacuum leaks. 5. Lyophilization has begun. Stoppering 1. Let the samples run until primary and secondary freeze-drying is complete. 2. To stopper the vials move the toggle switch on the Small Stoppering Chamber to the middle position marked STOPPER. The vials will move up, the stoppers will press against the clear lid and then seal the vials. 3. Once all of the vials are stoppered return the toggle switch to the closed position. 4. Release vacuum by turning the Freeze Dry Port to the vent position. Notes: Always vent the vacuum line before turning off the vacuum pump. Make sure all vacuum lines are secured to prevent leaks. Wear appropriate protective attire and eye protection. Clean after use. Installation of Small Chamber Cold Trap (Refer to Figure 2) 6. Place one end of the PVC Tubing over the ½ fitting on the side of the chamber and secure with a clamp. 7. Insert the ½ Stainless Steel Adapter approximately 1 into the other end of the PVC Tubing and secure with a clamp. 8. Insert the open end of the ½ adapter into one of the Ports on the Freeze Dryers Chamber. Labconco Instruction Sheet 1049200, Rev -, ECO H250 01/13 3 of 5

9. Position the switch on the Small Stoppering Chamber to the CLOSE position. 10. The Small Stoppering Chamber is now ready to use. Figure 1 Labconco Instruction Sheet 1049200, Rev -, ECO H250 01/13 4 of 5

Warranty- We are committed to providing our customers with quality equipment and service after the sale. Part of this objective involves keeping you informed of changes and new product additions. Labconco provides a warranty on all parts and factory workmanship. The warranty includes areas of defective material and workmanship, provided such defect results from normal and proper use of the equipment. The warranty for all Labconco products will expire one year from date of installation or two years from date of shipment from Labconco, whichever is sooner, except the following: Purifier Delta Series Biological Safety Cabinets, which carry a three-year warranty from date of installation or four years from date of shipment from Labconco, whichever is sooner. Carts carry a lifetime warranty. Glassware is not warranted from breakage when dropped or mishandled. This limited warranty covers parts and labor, but not transportation and insurance charges. In the event of a warranty claim, contact Labconco Corporation or the dealer who sold you the product. If the cause is determined to be a manufacturing fault, the dealer or Labconco Corporation will repair or replace all defective parts to restore the unit to operation. Under no circumstances shall Labconco Corporation be liable for indirect, consequential, or special damages of any kind. This statement may be altered by a specific published amendment. No individual has authorization to alter the provisions of this warranty policy or its amendments. Lamps and filters are not covered by this warranty. Damage due to corrosion or accidental breakage is also not covered. WARNING: various federal, state or local regulations may govern the disposal and/or emission of substances used in connection with this equipment. All users of this equipment are urged to become familiar with any regulations that apply in the user s area concerning the dumping of waste materials in or upon water, land or air and to comply with such regulations. Shipping Claims- If a shipment is received in visibly damaged condition, be certain to make a notation on the delivering carrier s receipt and have his agent confirm the damage on your receipt. Otherwise, the damage claim may be refused. If concealed damage or pilferage is discovered, notify the carrier immediately and retain the entire shipment intact for inspection. Interstate Commerce Commission rules requires that the claim be filed with the carrier within 15 days after delivery. NOTE: Do not return goods. Goods returned without prior authorization will not be accepted. Labconco Corporation and its dealers are not responsible for shipping damage. The recipient must file claims directly with the freight carrier. If authorization has been received to return this product, by accepting this approval, the user assumes all responsibility and liability for biological and chemical decontamination and cleansing. Labconco reserves the right to refuse delivery of any products that do not appear to have been properly cleaned and/or decontaminated prior to return. Contacting Labconco- If you have any questions that are not addressed in these instructions, or if you need technical assistance, please contact Labconco Sales Information Department at either (800) 821-5525, and Service Information at (800)-522-7658 or (816) 333-8811, between the hours of 7:00 a.m. and 6:00 p.m. Central Standard Time. Visit the Internet at http://www.labconco.com Or email: labconco@labconco.com Labconco Instruction Sheet 1049200, Rev -, ECO H250 01/13 5 of 5