Kirby Drop-In Packaged Refrigeration Units

Similar documents
Kirby Commander Condensing Unit

Kirby CO 2 Evaporators

DROP-IN + PLUG-IN UNITS

500 EX Fusion Compressor Series

Technical Data Ducted Three Phase Split System Air Conditioner

Evaporator E4 Series. Innovative Refrigeration Solutions. Floor Mounted Blast Chiller/Freezer F - Series

Air-Cooled Condensing Units with Compact Screw Compressors

LOW PROFILE EVAPORATORS

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Condensing Units CUS 15-60

Remote Air Cooled Condensers C2 Series

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Kramersaver Air Cooled Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MACH N-407 Heat Pump Air-Cooled Chiller

ENTHALPY TD SERIES CONDENSING UNITS. Enthalpy. Semi Hermetic TD Series Condensing Units (Medium / Low Temperature)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

ENTHALPY TD SERIES CONDENSING UNITS

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

PRODUCT RANGE: ROOFTOP PACKAGE

horizontal air discharge outdoor discus condensing unit

NATURAL REFRIGERANT SYSTEMS

SUBCRITICAL & TRANSCRITICAL SYSTEMS

PattonPak Stream Condensing Units

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

ENTHALPY HERMETIC CONDENSING UNITS

MAC N-407 Air-Cooled Chiller

Air Cooled Scroll Chiller / Heat Pump

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

49 Danfoss Thermostat Kits Ranco Varifix Kits

3-22 HP CONDENSING UNITS Technical Guide

Optyma Slim Pack Condensing Units

Stainless steel refrigerators & freezers

Copeland Scroll Outdoor Refrigeration Unit

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Benefit Cabinets. Performance. Efficiency

Benefit Cabinets. Performance. Efficiency

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

OPERATING INSTRUCTIONS

Filter Driers with Replaceable Core

Evaporators 60HZ version

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

High Profile Evaporator

Scroll Water Cooled Chiller

COMPANY PROFILE 2016

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Specifications Sheets

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

Copeland Scroll. Product Information. Outdoor condensing units for refrigeration applications

C13-Series Engineering Guide

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

Pool heating, efficiently

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

Air-Cooled Condensing Units with Bitzer Compressors

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Screw Water Cooled Chiller SCW210

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

R-410A AFFINITY SERIES DEX DEY Ton

CoolSpot Engineering Guide

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

160 Line. 1 Door Undercounter Refrigerator (+2/+10) - UK Plug. 160 Line

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PT E SERIES ACTIVE REFRIGERATORS ZANUSSI RANGE COMPOSITION FUNCTIONAL AND CONSTRUCTION FEATURES

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Mega Top Sandwich Prep Table Manual

Saving energy comes naturally to us.

Copeland Scroll Condensing Units for the Food Service Market

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

R-410A AFFINITY SERIES

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

Preparation Table Raised Condiment Rail models 8000N

Accumulators - Suction Line

N4H4. Product Specifications

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

GENESIS Indoor Air Conditioners

Specifications and Performance

MAC-120HE-03 Air-Cooled Chiller

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

Transcription:

Kirby Drop-In Packaged Refrigeration Units Ready to Install, so it s as easy as ABC 800W 4100W

Kirby Drop-In Packaged Refrigeration Units The Kirby Drop-in unit range will make it easier for you to install and complete your job. Front Cover - ABC With the Kirby range of Drop-In Packaged Units, life has been made easy. These plug and play, feature packed systems are supplied complete - ready to run and easy to install. It means the hard work is taken out of the job, so you can be on your way, sooner. Now Heatcraft have made it even easier to use the Kirby Drop-in units with a Dixell control installed as standard on all models, plus the medium temperature application units come with an extended cable so you are able to remote mount the digital thermostat. It s as easy as ABC! Kirby Drop-In Packaged Refrigeration Unit Nomenclature Data KS C 1800 4 Release Number Unit Capacity (Watts) R22 for M/T & R404a for L/T eg: 1800 = 1800 Watts Application C = Cool Room Range, M/T F = Freezer Room Range, L/T Unit Type KP = Low Profile Series KS = Standard Profile Series 2

Features & Benefits The Kirby Drop-in Packaged Refrigeration Units offer: Evaporator coil corrosion protection, liquid line dryer, capillary tube refrigerant control, pressure control & Dixell electronic control on all units Medium Temperature Units feature off cycle defrost only Low Temperature Units feature electric defrost with temperature switch termination and a pressure safety switch Fully wired with 3-pin domestic cable plug for all units New Design All new units now come with encapsulated pressure controls All new units now have 3 different temperature probes (one for the evaporator coil, one for the condenser coil, and one for the room temperature) All tubes in the top half of the drop-in units have been modified and re-modelled All new units use tube support and saddles for the drier to reduce vibration and noise All models use CFC-free foam insulation New and improved, slimline electrical box Units are ready to install straight from the box Notes Qualified refrigeration professionals should supervise initial selection and commissioning Kirby Drop-In Packaged Refrigeration Units are distributed via refrigeration professionals who provide on-going warranty and support Standard Profile Series Now supplied with a Dixell control installed as standard on all models Low Profile Series 3

Performance Data Medium Temperature Compressor Watts Grams Max Max Nom. Capacity @ +2 C Evap. KTD Model R22 Charge Amb. SST@Amb. HP Room Temp. KPC 800-4 BA9MG-1KS 1/3 800 6 620 43ºC +5 C KPC 1000-4 BA12MG-1KS 3/8 1000 6.5 645 43ºC +5 C KPC 1200-4 BA14MG-1KS 1/2 1150 6.5 980 43ºC +5 C KPC 1400-4 BA16MG-4KS 3/4 1440 6.2 1150 43ºC +5 C KPC 1700-4 BA18MG-1KS 7/8 1650 6.5 1100 43ºC +10 C KSC 1800-4 BA18MG-1KS 7/8 1750 6 1100 43ºC +10 C KSC 2000-4 WJ26MHG-3C 1-1/4 2110 6.5 1435 43ºC +10 C KSC 2900-4 WJ31MHG-1C 1-1/2 2850 7 1800 43ºC +10 C KSC 4100-4 AW48MHG-1C 2 4100 6.5 2700 43ºC +10 C NOTES: Ratings given on medium temperature units are at conditions of +2 C room temperature, +32 C ambient with R22 The M/T range packaged units are designed to operate within an ambient temperature range of +10 C to +43 C and a room temperature range of +2 C TO +15 C. Medium Temperature Cool Rooms - Units from 1140W to 4100W at +2 C storage. Approved range 2 C to 15 C Low Temperature Compressor Watts Grams Max Max Nom. Capacity @ -15 C Evap. KTD Model R404a Charge Amb. SST@Amb. HP Room Temp. KPF 1000-4 WJ26LZ-3C 3/4 940 6.5 975 43ºC -15 C KPF 1200-4 WJ31LZ-1C 1 1150 6.5 820 43ºC -15 C KSF 1500-4 AW43LZ-5C 1-1/4 1525 4 1450 43ºC -15 C KSF 2000-4 AW54LZ-1 1-1/2 1970 4.5 1500 43ºC -15 C KSFT 2600-4 AVA2490ZXG 2 2540 4.5 1700 43ºC -15 C NOTES: Ratings given on low temperature units are at conditions of -15 C room temperature, +32 C ambient with R404a The L/T range packaged units are designed to operate within an ambient temperature range of +10 C to +43 C and a room temperature range of -10 C TO -25 C. Low Temperature Freezer Rooms - Units from 1970W to 2540W at -15 C. Approved range -25 C to -10 C Capacity Correction Factors & Application Range Obtain capacity correction factor from the appropriate graph, using the design conditions for ambient temperature and storage room temperature (air on). Multiply the unit capacity by the capacity correction factor to obtain the adjusted unit capacity in watts. CAPACITY CORRECTION FACTORS - M/T UNITS CAPACITY CORRECTION FACTORS - L/T UNITS FACTOR 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 FACTOR 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.6 10 15 20 25 30 35 40 43 AMBIENT (ºC) ON AIR ON 10ºC 0ºC AIR 5ºC AIR ON 15ºC AIR ON 0.0 10 15 20 25 30 35 40 43 AMBIENT (ºC) -25ºC AIR ON -20 ºC AIR ON- 15ºC AIR ON -10ºC AIR ON 4

Technical Data Medium Temperature Compressor Condenser Fan Evaporator Fan Unit Amps Amps Watts Amps Watts Amps Model Volts / Ph Volts / Ph RLA* MCC* LRA RLA* Input RLA* Input RLA* MCC* LRA KPC 800-4 BA9MG-1KS 2.9 4.2 14.5 240 / 1 0.32 40 240 / 1 0.26 27 4.2 5.3 14.5 KPC 1000-4 BA12MG-1KS 2.5 3.6 14.8 240 / 1 0.32 40 240 / 1 0.26 30 3.2 4.7 14.8 KPC 1200-4 BA14MG-1KS 2.9 3.8 15.2 240 / 1 0.6 80 240 / 1 0.3 35 3.6 5.3 15.2 KPC 1400-4 BA16MG-4KS 3.8 4.4 14.6 240 / 1 0.6 80 240 / 1 0.28 45 4.2 5.8 14.6 KPC 1700-4 BA18MG-1KS 3.8 5.8 19 240 / 1 0.6 80 240 / 1 0.28 45 4 7.2 19 KSC 1800-4 BA18MG-1KS 3.8 5.8 19 240 / 1 0.6 80 240 / 1 0.32 73 4.3 6.7 19 KSC 2000-4 WJ26MHG-3C 6.7 10.5 31 240 / 1 0.32 73 240 / 1 0.32 73 5.4 11.1 31 KSC 2900-4 WJ31MHG-1C 7.6 11.9 36 240 / 1 0.6 80 240 / 1 0.32 73 7.4 13.7 36 KSC 4100-4 AW48MHG-1C 10.8 16.8 55 240 / 1 0.6 80 240 / 1 0.32 73 10.6 18.6 55 * = Unit and Compressor RLA data are taken at +2 C air on, +32 C ambient condition for M/T application units. Unit MCC data are based on compressor MCC + fan RLA. Air Flow (L/S) * LwA: Sound power level, db(a) ** LpA: Sound pressure level, db(a) Condenser Evaporator Cut Hole Sound Data Fan Dia. X QTY Air Flow (L/S) Fan Dia. X QTY Length Dimm. in mm Width LwA * LpA 3m ** KPC 800-4 120 230 x 1 165 178 x 3 825 435 67.6 47.1 KPC 1000-4 105 230 x 1 175 178 x 3 825 435 68.1 47.6 KPC 1200-4 275 300 x 1 235 178 x 3 1045 435 70.1 49.6 KPC 1400-4 245 300 x 1 270 178 x 3 1045 435 70.6 50.1 KPC 1700-4 245 300 x 1 270 178 x 3 1045 435 71.6 51.1 KSC 1800-4 245 300 x 1 380 300 x 1 660 550 71.6 51.1 KSC 2000-4 340 300 x 1 360 300 x 1 660 550 73.3 52.8 KSC 2900-4 580 300 x 2 755 300 x 2 1085 660 73.6 53.1 KSC 4100-4 560 300 x 2 820 300 x 2 1085 660 74.1 53.6 Low Temperature Compressor Condenser Fan Evaporator Fan Unit Amps Amps Watts Amps Watts Amps Model Volts / Ph Volts / Ph RLA* MCC* LRA RLA* Input RLA* Input RLA* MCC* LRA KPF 1000-4 WJ26LZ-3C 4.2 6.2 30 240 / 1 0.6 80 240 / 1 0.3 35 4.2 7.7 30 KPF 1200-4 WJ31LZ-1C 4.9 7.4 36 240 / 1 0.6 80 240 / 1 0.3 35 6.7 8.9 36 KSF 1500-4 AW43LZ-5C 6.9 9.9 43 240 / 1 0.32 73 240 / 1 0.65 155 7.9 10.9 43 KSF 2000-4 AW54LZ-1 8.1 12.3 43 240 / 1 0.6 80 240 / 1 0.32 73 10.6 14.1 43 KSFT 2600-4 AVA2490ZXGB-1 3.6 / Ph 8.3 / Ph 38.3 / Ph 240 / 1 0.6 80 240 / 1 0.32 73 6.4 / Ph 10.1 / Ph 38.3 / Ph * = Unit and Compressor RLA data are taken at -15 C air on, +32 C ambient condition for L/T application units. Unit MCC data are based on compressor MCC + fan RLA. Fan Dia. X QTY * LwA: Sound power level, db(a) ** LpA: Sound pressure level, db(a) Condenser Evaporator Cut Hole Sound Data Air Flow (L/S) Fan Dia. X QTY Air Flow (L/S) Heater Element (Watts) Dimm. in mm LwA * LpA 3m ** KPF 1000-4 300 x 1 275 178 x 3 235 1480 1045 435 70.4 49.9 KPF 1200-4 300 x 1 245 178 x 3 235 1480 1045 435 70.9 50.4 KSF 1500-4 300 x 1 340 350 x 1 530 1795 660 550 72.9 52.4 KSF 2000-4 300 x 2 580 300 x 2 750 2300 1085 660 73.4 52.9 KSFT 2600-4 300 x 2 560 300 x 2 820 2300 1085 660 76.4 55.9 Length Width Notes: All Kirby Kulthorn hermetic reciprocating compressors used in Kirby drop-in packaged units are charged with PolyolEster (POE) oil. POE oil can be used with HCFC refrigerants, such as R22, and HFC refrigerants, such as R404A, R507, R407C and R134a. Use ONLY POE oil, do NOT mix POE with other oils, when using HFC refrigerants. Sound data is based on manufacturers data for compressor and tested fan data. Actual results may vary depending on condtions and application 5

Technical Data Dixell Control Settings Dixell controls are supplied with factory default settings as listed in the Dixell instruction manual, supplied with individual units. Heatcraft alters some of these settings as listed in the table below. Control Temperature Defrost Cut In Cut Out Defrost Termination Fans Stop Time Defrost Type Control Type * KPC 800-4 XR30CX 3 C 1 C - - - Off Cycle Fixed To Unit KPC 1000-4 XR30CX 3 C 1 C - - - Off Cycle Fixed To Unit KPC 1200-4 XR30CX 3 C 1 C - - - Off Cycle Fixed To Unit KPC 1400-4 XR30CX 3 C 1 C - - - Off Cycle Fixed To Unit KPC 1700-4 XR30CX 3 C 1 C - - - Off Cycle Fixed To Unit KSC 1800-4 XW60K 3 C 1 C - - - Off Cycle Fixed To Unit KSC 2000-4 XW60K 3 C 1 C - - - Off Cycle Fixed To Unit KSC 2900-4 XW60K 3 C 1 C - - - Off Cycle Fixed To Unit KSC 4100-4 XW60K 3 C 1 C - - - Off Cycle Fixed To Unit KPF 1000-4 XW60K -15 C -17 C 2 C 11 C 20 Min Electric Defrost Remote Mount Option KPF 1200-4 XW60K -15 C -17 C 2 C 11 C 21 Min Electric Defrost Remote Mount Option KSF 1500-4 XW60K -15 C -17 C 2 C 11 C 22 Min Electric Defrost Remote Mount Option KSF 2000-4 XW60K -15 C -17 C 2 C 11 C 23 Min Electric Defrost Remote Mount Option KSFT 2600-4 XW60K -15 C -17 C 2 C 11 C 24 Min Electric Defrost Remote Mount Option * Remote touch pad supplied with cable up to 10 metres for units supplied with XW60K thermostat. * Note: Temperature ratings are available on page 4. 6

Physical Specifications Medium Temperature Dimensions (mm) A B C D E F G H K Packed Weight (kg) Shipping Volume (m 3 ) KPC 800-4 810 420 890 500 290 210 60 500 20 33 0.24 KPC 1000-4 810 420 890 500 290 210 60 500 20 35 0.24 KPC 1200-4 1030 420 1117 507 351 226 35 577 33 48 0.35 KPC 1400-4 1030 420 1117 507 351 226 35 577 33 52 0.35 KPC 1700-4 1030 420 1117 507 351 226 35 577 33 60 0.35 KSC 1800-4 645 535 705 595 338 582 105 920 20 104 0.45 KSC 2000-4 645 535 705 595 384 566 105 950 20 107 0.45 KSC 2900-4 1070 645 1150 730 420 576 130 996 25 140 0.98 KSC 4100-4 1070 645 1150 730 420 637 130 1057 25 172 0.98 Low Temperature Dimensions (mm) A B C D E F G H K Packed Weight (kg) Shipping Volume (m 3 ) KPF 1000-4 1030 420 1117 507 351 226 35 577 33 48 0.35 KPF 1200-4 1030 420 1117 507 351 226 35 577 33 60 0.35 KSF 1500-4 645 535 705 595 385 579 105 964 20 108 0.45 KSF 2000-4 1070 645 1150 730 420 576 130 996 25 155 0.98 KSFT 2600-4 1070 645 1150 730 430 637 130 1067 25 160 0.98 Note: Add 15mm to plug dimensions A & B shown in diagrams for clearance hole size. Hole must be cut square. For further information please refer to your Kirby Drop-In Handbook which is supplied with the product. 7

australia 13 23 50 heatcraft.com.au new zealand 0800 653 330 heatcraft.co.nz Australia Head Office Heatcraft Australia Pty Ltd, 286 Horsley Road, Milperra NSW 2214 Locked Bag 63, Wetherill Park NSW 1851 (+61) 2 9774 7155 New Zealand Head Office Heatcraft New Zealand Pty Ltd 12 George Bourke Drive, Mt Wellington PO Box 12371 Penrose, Auckland (+64) 9 276 4888 All trade marks and registered trade marks are the property of their respective owners and are used for identification purposes only. Copyright 2015 Heatcraft Australia Pty Limited. Heatcraft Australia continually strive to improve products and processes. We reserve the right to modify product features without notice. Information is correct at time of printing.