SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

Similar documents
PLAN REVIEW CHECKLIST

About This Report. Risk Id: 32 NC N Church St Charlotte NC Mecklenburg County Last Update: 3/1/2015 On-Site Survey: 3/1/2015

Sprinkler Permit Applications

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

Center for Life Safety Education

Backflow Prevention for Fire Sprinkler Systems. State of Illinois Plumbing Code

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

FIRE SPRINKLER SYSTEMS POLICY

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

ADDENDUM #1 ITB# Fire Protection Maintenance Services Responses to Clarification Questions 10/06/2015

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

FIRE SPRINKLER SYSTEMS POLICY

Fire Sprinkler System Design and Installation Requirements

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

SPRINKLER SYSTEM DRY WET

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Box-in-Box Cold Storage Fire Protection Options

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters

CITY OF PASADENA FIRE DEPARTMENT

PLAN REVIEW SUBMITTAL GUIDE

SECTION WET-PIPE SPRINKLER SYSTEMS

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

FIRE SPRINKLER SHOP DRAWING SUBMITTAL REQUIREMENTS

Deluge/Preaction Systems Annotated Instructor s Guide

Deluge/Preaction Systems Annotated Instructor s Guide

1 Exam Prep. Questions and Answers

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

By: Russell Bainbridge March 18th, 2016 FPE 596

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

DEPARTMENTAL GUIDELINES CHAPTER 6 TACTICAL OPERATIONS

HDPE PIPING SYSTEMS. FIRE FIGHTING APPLICATION by POLYETHYLENE PIPE.

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

NFPA Edition. NFPA 13 (2016 Edition) Hot Topics and NFPA 13 FAQ s. Highlights of 2016 Changes. Storage Commodity Classification 4/29/2014

Fire Sprinkler Submittal Requirements and Acceptance Testing

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Fire Sprinkler Plan Submittal Form

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

DIVISION 21 - FIRE SUPPRESSION

Design & Construction Standards, Revised January

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Fire Protection Coffee Break Training May 2016

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:

New Construction Fire Inspection Process

AUTOMATIC FIRE SPRINKLER SYSTEMS

FIRE SAFETY INSPECTION REPORT REDPOINT JACKETS LTD, DHAKA, BANGLADESH

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

HYDRAULIC CALCULATIONS. 952 Arapahoe

Gas Station & C Store SECTION CWM Job No

False Sense of Security???

Site Plans. Fire Code Requirements

Redlands Fire Department Fire Protection Standard

Tire Storage. Michigan Fire Inspectors Society Fall Conference

McMAHON FP200 OUTAGAMIE COUNTY ADMINISTRATION CENTER S. WALNUT & W. 8TH, APPLETON, WI ALTERATION / ADDITION

The Theory and Practice of Variable Orifice in Automatic Sprinkler Systems

9/15/ Cantara Lane Vista, CA (760)

DIVISION 21 - FIRE SUPPRESSION

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

What You Need to Know about Residential Sprinkler Design

Fire & Life Safety Requirements For Fire Department Access and Water Supplies

Mobile Fire Rescue Department Bureau of Fire Prevention

Fire Suppression Rating Schedule

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

Sprinkler System Installer Level 2

FIRE SAFETY INSPECTION REPORT

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

Expectations (continued)

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

FIRE SUPPRESSION RATING SCHEDULE ITEMS CONSIDERED AND ASSOCIATED POINTS OF CREDIT

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Annual Water-Based Fire Protection Systems Inspection

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

ASCR2, ASCR4, ASC2, ASR2, ASD2

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

To expedite the plan review and inspection processes, please refer to the information below.

TotalPac 3 Wet pipe system c/w retard chamber

TECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)

SECTION WATER BASED FIRE SUPPRESSION SYSTEMS

June 2018 Safety Meeting Fire Extinguishers Part I

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Port of St Helens SIA Aircraft Hanger Scappoose, OR

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

FIRE CODE. Coal City Fire District International Fire Code Update. 35 S. DeWitt Place Coal City, IL

Preview of the MA Building Code (780 CMR) 9 th edition

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

SECTION SPRINKLER SYSTEMS

Transcription:

210 N CHURCH ST CHARLOTTE NC 28202-2256 MECKLENBURG COUNTY RISK ID: 32 NC99 040235 ON-SITE SURVEY: 4/1/2009 LAST UPDATE: 4/1/2009 SUMMARY Building receiving sprinkler credit: SPRINKLERED Grade: 68 Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91% Hose Stream Demand Met: 0% Automatic Sprinkler Grade Components Water Supply 21 Sprinkler Components 9 Sprinkler Testing 0 Non-Sprinklered Areas 0 Rack Storage Obstructions 0 Building Conditions 2 Total (Maximum of 100) 32 Automatic Sprinkler Grade (Range 0-100, 100 being best) 68 The Automatic Sprinkler Grading is based on a 100-point scale, with scores below 100 indicating that deficiencies exist in the system. The final grading is the difference between 100 and the sum of the points for each identified deficiency. Six major categories of sprinkler protection features are evaluated to arrive the final sprinkler grading. * This assessment report is based on observations made by Verisk Field Representative's using Verisk's SCOPES methodology as the technical basis.

WATER SUPPLY This section evaluates the adequacy of water supply available with respect to the sprinkler system demand, including details about system design, available water supply sources, and related deficiencies. DESIGN INFORMATION & SPRINKLER DEMAND Ground Floor Area: N/A Building Combustibility Class: 2 Elevation to the highest line of sprinklers: 330 Feet x 0.434 = 143 Elevation PSI HYDRAULICALLY CALCULATED SYSTEM Building Sprinkler Occupancy Class: 2 Sprinkler System Demand: Hose Stream Demand: Water Duration: 430 GPM at 100 PSI at base of riser 250 GPM 90 minutes Determination of Sprinkler Occupancy Class (SPOC) Square Feet Percentage SPOC 1 574,900 66% SPOC 2 292,540 34% Hydraulically Designed Systems Information Density 0.200 GPM/sq.ft. Remote Area 1,950 sq.ft. Demand 680 GPM at 100 PSI at base of riser, Including 250 GPM Hose, 90 minutes duration SPOC 3 2,580 Total 870,020 100% SPOC is a determination of the overall occupancy hazard for the building for sprinkler system design, similar to the occupancy classifications (e.g., light hazard, ordinary hazard, etc.) in NFPA 13, Standard for the Installation of Sprinkler Systems. Information source ESFR PLACARD No EVALUATION OF WATER SUPPLIES Water Supply Sources Source Supply Source / Static Residual Flow Limited Test Feet Gauge Location Pressure (PSI) Pressure (PSI) (GPM) Storange Date Above/Below Riser Volume 1 City Water Supply / hydrant 110 95 1230 3/1/2004 0 2 of 6 6/5/2015 5:13 PM

HYDRAULICALLY CALCULATED SYSTEMS Water Supply Deficiency Evaluation Supply Flow at Pressure at Storage Deficient Deficient Water Supply Points Source Intersection Intersection Deficiency Storage Pressure Deficiency (GPM) (PSI) Percent Adjustment Adjustment Percentage Factor Factor Supply Source 1 389 107 N/A 1 1 9 6 System with worst demand: Hydraulic Primary Water Supply Source: 1 Water Supply Primary water supply deficiency 6 Secondary water supply deficiency No or insufficient secondary water supply 10 Hose stream supply deficiency Insufficient hose stream supply 5 Water Supply 21 SPRINKLER SYSTEM COMPONENTS This section evaluates key system components and lists related deficiencies identified. Key components evaluated include those items that may have direct effects on sprinkler system performance, such as the condition and layout of valves, piping and sprinklers, and miscellaneous items of design, installation and maintenance. Sprinkler System Components Deficiency for dry pipe protection Dry-pipe valve with required operable quick opening device and supervised 4 Deficiency for miscellaneous items and maintenance No sprinkler plans and/or hydraulic calculations with sprinkler grading based on riser placard 5 Sprinkler System Components 9 3 of 6 6/5/2015 5:13 PM

SPRINKLER SYSTEM TESTING This section reviews the initial and periodic tests conducted for the sprinkler system in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-based Fire Protection, including the initial flushing and hydrostatic testing of underground and aboveground piping, annual main drain test, dry-pipe valve trip test, fire pump discharge test and internal pipe exam. Periodic Test Information Date Installed Date Tested Main Drain N/A 1/29/2009 Dry Pipe Valve N/A 1/29/2009 Fire Pump Perf N/A N/A Internal Pipe Exam 9/1/2008 N/A Dry pipe system covers less than 5,000 Square Feet and less than 25% of protected building area: No Sprinkler System Testing No deficiencies observed 0 Sprinkler System Testing 0 NON SPRINKLERED/OBSTRUCTED AREAS This section identifies all unused and usable areas that lack required sprinkler protection in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, and the specific requirements of the Specific Commercial Property Evaluation Schedule (SCOPES). Non-Sprinklered/Obstructed Areas No deficiencies observed 0 Non-Sprinklered/Obstructed Areas 0 RACK STORAGE OBSTRUCTIONS 4 of 6 6/5/2015 5:13 PM

Rack Storage Obstruction No deficiencies observed 0 Rack Storage Obstruction 0 BUILDING CONDITIONS This section evaluates structural conditions in the building that can have negative impact on the effectiveness and efficiency of the sprinkler system, including unprotected floor openings, open sided levels and stories that have excessive single story height. Building Condition Deficiency for floor opening protection Floor opening(s) protected with closely spaced sprinklers and draft curtain 2 Building Condition 2 5 of 6 6/5/2015 5:13 PM

HYDRAULIC GRAPH Hydraulic graph is a graphical comparison of the available water supply and sprinkler system demand, which also displays the key variables used in the water supply assessment. 160 ( 0, 1 4 3 ) 140 Pressure (PSI) 120 ( 3 7 3, 1 1 0 ) 100 ( 4 3 0, 1 0 0 ) 80 0 400 800 1 Flow (GPM) Hydraulic Sprinkler System Demand Water Supply Water Supply Adjusted to Base of Riser POLICY#/INSURED: 543216789-A287 ORDERED BY: INSURANCE SERVICES OFFICE - ISO MARKETING SUPPORT (S. RAMAMURTHY) 2008, 2014 Insurance Services Office, Inc. All rights reserved., 6 of 6 6/5/2015 5:13 PM