Hot Water Recirculation Loop Field Verification Requirements

Similar documents
Single Dwelling Unit Hot Water System Distribution Project Name: Enforcement Agency: Permit Number:

HERS Verified Single Dwelling Unit Hot Water System Distribution (Page 1 of 6)

Building Department Informational Handout

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

DHW Measures and Concepts

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Residential Compliance June 2014

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

Read Only Document Not For Distribution

Guidelines for Specifying Structured Plumbing Systems January, 2007

Element D Services Heating, Ventilating, and Air Conditioning

MONTECITO FIRE PROTECTION DISTRICT

Gulfport, Mississippi 21 May 2007

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

Save Water... Save Energy With Efficient Hot Water Delivery

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

Proponent: Edward R. Osann, on behalf of Natural Resources Defense Council; Ryan Meres, on behalf of Institute for Market Transformation.

Allcan TM Installation Manual

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

Engineering Bulletin Rev B. Contents. Piping Arrangements for Heat Pump Water Heating Systems

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

APPENDIX L ALTERNATE PLUMBING SYSTEMS

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

GOLD Plus 30/40/60/80

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

Trade Product List 2013 BIOMASS ACCESSORIES

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

Residential Water Heater Alteration or Replacement Requirement Per the 2016 California Energy Code (CEC)

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

Special Requirements For Health Care Facilities

Installation & Operation Manual Models: TSU

Meeting the One-Cup Challenge

AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762

MECHANICAL DESIGN. Full service Mechanical Design Professionals that can provide the full package!

Design and Construction Standards SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT

DUCT LEAKAGE (Page 1 of 3)

Installation, Start-Up and Service Instructions

PCAH SERIES AIR HANDLER

Steven Winter Associates, Inc. J827

STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS

Instantaneous Water Heaters

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

HVAC Water chiller selection and optimisation of operation

Fundamentals of Hydronic Design

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

The smart way to instant hot water comfort.

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation, Start-Up and Service Instructions

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

SEISCO APPLICATIONS & DIAGRAMS

Distribution Restriction Statement

Priming Aids ASH and AHP

... Green Building Details

SECTION PLUMBING EQUIPMENT

WHY TANKLESS? HOW TANKLESS WORKS LONGER LASTING CONTINUOUS HOT WATER CLEAN & FRESH WATER ENERGY SAVINGS SPACE SAVINGS. Secondary Heat Exchanger

FIRE SPRINKLER SYSTEMS POLICY

Hot Water Delivery Systems in the ICC Green Code. ACEEE Hot Water Forum

EnergyGauge USA Release Notes

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

Circuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.

Updated: September 12, 2018 DIVISION INTEGRATED AUTOMATION. INTEGRATED AUTOMATION Page 1 of INTEGRATED AUTOMATION

2. All necessary storm and sanitary pumps shall be tied into emergency power, and sump levels shall be monitored electronically through the B.A.S.

Technical Criteria for District Energy Ready Buildings Master Requirement ENG 108 Building Department: ,

KEY POINTS OF DESIGN, INSTALLATION AND MAINTENANCE FOR CONFIGURING LIEBERT XD SYSTEMS. Technical Note

TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS

Product Manual. Companion Water Heater. Maintenance Parts. Installation Startup. for WM97+ Gas-Fired Boilers

FIRE SPRINKLER SYSTEMS POLICY

2016 Plumbing Supplemental Plan Review List

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

Thermostatic mixing valves with replaceable cartridge for centralized systems

ERGOMAX 7 INSTALLATION

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Mega-Stor II. Stainless Steel, Indirect Water Heaters INSTALLATION AND OPERATING INSTRUCTIONS

Installation & Operation Manual Models: SIT030 - SIT119

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

SECTION HYDRONIC PIPING AND SPECIALTIES

LEED for Homes V4 Provisional Alternative Compliance Paths for the Canadian market March, 2017

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

Thermostatic mixing valves with interchangeable cartridges

LIQUID RING PUMPS FOR THE POWER INDUSTRY

DIGITAL HOT WATER SOLUTIONS

Hempcrete building and Solar thermal reincarnation

CRU-S Series Stainless Steel Condensate Recovery Unit

According to the following European Regulations which come into force:

2007 CALIFORNIA BUILDING CODE & 2008 BUILDING ENERGY EFFICIENCY STANDARDS

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

Indirect Fired Water Heaters

Transcription:

Hot Water Recirculation Loop Field Verification Requirements Multiple Recirculation Loop Credit, Multifamily The HERS Rater is required to verify the following items including the installation criteria below according to forms CF-3R-PLB-21-H or for non-residential projects the NRCV-PLB-21-H as applicable. 1. All buildings with 8 or more dwelling units have a minimum of 2 recirculation loops. 2. Each loop roughly serves the same number of dwellings. 3. Each loop will have its own pump and controls. RA3.6.9 HERS-Multiple Recirculation Loop Design for DHW Systems Serving Multiple Dwelling Units The visual inspection shall verify that a central DHW system serving a building with more than eight dwelling units has at least two recirculation loops, each serving roughly the same number of dwelling units. Unique building sections may have additional recirculation loops. These recirculation loops may be connected to the same water heating equipment or be connected to independent water heating equipment. The HERS inspector shall verify that: (a) There are at least two recirculation loops each serving roughly the same number of dwelling units. Unique sections of the building may have separate loops. Ideally each loop will have its own pump and controls. 1. Installation Criteria Recirculation Systems Serving Multiple Dwelling Units Multifamily buildings may have individual water heaters for each unit, but they are more likely to have a central water heating system with a recirculation loop that supplies each of the units. This recirculation loop is comprised of a supply portion, of larger diameter pipe connected to smaller diameter branches that serve multiple dwelling units, guest rooms, or fixtures and a return portion that completes the loop back to the water heating equipment. The large volume of water which is recirculated during periods of high use creates situations that require the installation of certain controls and servicing mechanisms to optimize performance and allow for lower cost of maintenance. The following paragraphs cover the requirements for systems serving multiple dwelling units and with recirculation loops and may also apply to individual dwelling units with recirculation systems. Outlet Temperature controls 110.3(c)1 On systems that have a total capacity greater than 167,000 Btu/hr., outlets that require higher than service water temperatures as listed in the ASHRAE Handbook, Applications Volume, shall have separate remote heaters, heat exchangers, or boosters to supply the outlet with the higher temperature. Copyright CalCERTS, Inc. 2014 1 P a g e

Controls for Hot Water Distribution Systems 110.3(c)2 Service hot water systems with circulating pumps or with electrical heat trace systems shall be capable of automatically turning off the system. Insulation, Storage Tanks 110.3(c)4 Insulation. Unfired service water heater storage tanks and backup tanks for solar water-heating systems shall have: i. External insulation with an installed R-value of at least R-12; or ii. iii. Internal and external insulation with a combined R-value of at least R-16; or The heat loss of the tank surface based on an 80 F water-air temperature difference shall be less than 6.5 Btu per hour per square foot. Any unfired tanks (used as a back-up for solar water heating or as storage for a boiler) must either be insulated externally with R-12 or have a label indicating the tank is internally insulated with R-16. Air Release Valves 110.3(c)5A Air release valve or vertical pump installation. An automatic air release valve shall be installed on the recirculation loop piping on the inlet side of the recirculation pump and no more than 4 feet from the pump. This valve shall be mounted on top of a vertical riser at least 12 in length and shall be accessible for replacement and repair. Alternatively, the pump shall be installed on a vertical section of the return line. The constant supply of new water in combination with the continuous operation of the pump creates the possibility of the pumps cavitation due to air in the water. Cavitation is the formation of bubbles in the low pressure liquid on the suction side of the pump. The cavities or bubbles will collapse when they pass into the higher regions of pressure, causing noise, and vibration, which may lead to damage to many of the components. In addition there is a loss in capacity and the pump can no longer build the same head (pressure). Ultimately this impacts the pump s efficiency and life expectancy. Cavitation shall be minimized by either the installation of an air release valve or mounting the pump vertically. The air release valve must be located no more than 4 feet from the inlet of the pump. The air release valve must be mounted on a vertical riser with a length of at least 12 inches. Copyright CalCERTS, Inc. 2014 2 P a g e

Backflow Prevention 110.3(c)5B Recirculation loop backflow prevention. A check valve or similar device shall be located between the recirculation pump and the water heating equipment to prevent water from flowing backwards though the recirculation loop. Temperature and pressure differences in the water throughout a recirculation system can create potentials for backflows. This can result in cooler water from the bottom of the water heater tank and water near the end of the recirculation loop flowing backwards towards the hot water load and reducing the delivered water temperature. To prevent this from occurring, the Standards require that a check valve or similar device be located between the recirculation pump and the water heating equipment. Equipment for Pump Priming/Pump Isolation Valves 110.3(c)5C Equipment for pump priming. A hose bibb shall be installed between the pump and the water heating equipment. An isolation valve shall be installed between the hose bibb and the water heating equipment. This hose bibb is used for bleeding air out of the pump after pump replacement. 110.3(c)5D Pump isolation valves. Isolation valves shall be installed on both sides of the pump. These valves may be part of the flange that attaches the pump to the pipe. One of the isolation valves may be the same isolation valve as in Item C. A large number of systems are allowed to operate until complete failure simply because of the difficulty of repair or servicing. Repair labor costs can be reduced significantly by planning ahead and designing for easy pump replacement when the pump fails. Provision for pump priming and pump isolation valves help reduces maintenance costs. To meet the pump priming equipment requirement, a hose bibb must be installed between the pump and the water heater. In addition, an isolation valve shall be installed between the hose bibb and the water heating equipment. This configuration will allow the flow from the water heater to be shut off, allowing the hose bibb to be used for bleeding air out of the pump after pump replacement. The requirement for the pump isolation valves will allow replacement of the pump without draining a large portion of the system. The isolation valves shall be installed on both sides of the pump. These valves may be part of the flange that attaches the pump to the pipe. One of the isolation valves may be the same isolation valve as in paragraph C. Copyright CalCERTS, Inc. 2014 3 P a g e

Connection of Recirculation Lines 110.3(c)5E Cold water supply and recirculation loop connection to hot water storage tank. Storage water heaters and boilers shall be plumbed in accordance with the manufacturer s specifications. The cold water piping and the recirculation loop piping shall not be connected to the hot water storage tank drain port. Manufacturer s specifications should always be followed to assure optimal performance of the system. The cold water piping and the recirculation loop piping should never be connected to the hot water storage tank drain port. Backflow Prevention in Cold Water Supply 110.3(c)5F Cold water supply backflow prevention. A check valve shall be installed on the cold water supply line between the hot water system and the next closest tee on the cold water supply line. The system shall comply with the expansion tank requirements as described in the California Plumbing Code Section 608.3. The dynamic between the water in the heater and the cold water supply are similar to those in the recirculation loop. Thermo-syphoning can occur on this side of this loop just as it does on the recirculation side of the system. To prevent this, the Standards require a check valve to be installed on the cold water supply line. The valve should be located between the hot water system and the next closest tee on the cold water supply line. Note that the system shall comply with the expansion tank requirements as described in the California Plumbing Code Section 608.3. Copyright CalCERTS, Inc. 2014 4 P a g e

Dedicated Return Line 120.3 Distribution systems must have a dedicated return line which is fully insulated. Requirements for Pipe Insulation HERS verification of Pipe Insulation requirements follows RA3.6.2 and the associated installation criteria discussed previously. All hot water pipes are insulated per the insulation requirements of Table 120.3A (1 insulation for 1 and smaller pipes. 1.5 insulation for 1 to 1.5 inch pipes). 150.0(j)2 All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated and the insulation thickness shall be selected based on the conductivity range in TABLE 120.3-A and the insulation level shall be selected from the fluid temperature range based on the thickness requirements in TABLE 120.3-A: i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. iii. iv. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. All piping associated with a domestic hot water recirculation system. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. Copyright CalCERTS, Inc. 2014 5 P a g e