Safety Hazards Thermal Systems Laboratory Rooms 106 & 110

Similar documents
As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

In the name of God. Jami Institute of Jami - Mehdi Rasti

ENSC 388: Engineering Thermodynamics and Heat Transfer

Heat Exchangers. Heat Exchangers 1

How is the heat transfer?

armfield COMPUTER CONTROLLED HEAT EXCHANGER SERVICE MODULE HT30XC series issue 2

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Heat exchangers are devices that facilitate the exchange of heat between

2. HEAT EXCHANGERS MESA

Performance Study of Triple Concentric Pipe Heat Exchanger

Mechanical Engineering Department Sheet (1)

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

MECHANICAL SCIENCE Module 2 Heat Exchangers

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

COMPUTER-CONTROLLED HEAT TRANSFER TEACHING EQUIPMENT HT10XC NEW ACCESSORY HT20 CONDUCTIVITY OF LIQUIDS AND GASES

Outlines. 1. Introduction of Safety at Laboratories. 2. Emergency Situations. 3. Basic Safety Rules for All the Labs (Engg.

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

CL4001 HEAT TRANSFER OPERATIONS

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Mill, Microcut Grinder STANDARD OPERATING PROCEDURE

Extruder, Twin-screw, Large STANDARD OPERATING PROCEDURE

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Study on the Effect of Blade Angle on the Performance of a Small Cooling Tower

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998

P.A. Hilton Ltd. Figure 2: HC655A Optional Computer Linking Upgrade

Keywords: Triple tube heat exchanger (TTHE), hot water, cold water, CFD simulation.

NUMERICAL AND EXPERIMENTAL ANALYSIS OF A DEMAND-SIDE HEAT EXCHANGER FOR DOMESTIC HOT WATER HEATING

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER

Influence of Feed Water Heaters on the Performance of Coal Fired Power Plants

International Journal of Engineering Research & Technology (IJERT) ISSN: Vol. 2 Issue 10, October

3.5-GALLON PARTS WASHER OWNER S MANUAL

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Centrifuge STANDARD OPERATING PROCEDURE

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

SECTION 1-1 SAFETY PRECAUTIONS DOUBLE ARM MIXER CHAPTER 1: SAFETY

Eastern Mediterranean University Department of Mechanical Engineering Laboratory Handout

Mixer, Planetary Food STANDARD OPERATING PROCEDURE

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Java Development Program on Parallel and Counter Flow Heat Exchanger

Helicoil and Shell-Tube Heat Exchanger. Abdullah AlThomairi, Ahmed Sajjad, and Faris AlShuaibi. October 25, 2014

Falling Film Heat Exchangers for Solar Water Heaters

A Study of Heat Transfer Using Corrugated Al 2 o 3 microparticles

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Centrifuge STANDARD OPERATING PROCEDURE

Enhancement of COP in Vapour Compression Refrigeration System

STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER USING AL 2 O 3 MICROPARTICLES

FACSCalibur Startup Procedures

Design and Experimental Analysis of Concentric Tube Heat Exchangers with Various Fins

LABORATORY INSPECTION CHECKLIST

Mixer with Lifting Cart STANDARD OPERATING PROCEDURE

Heat Exchangers. Seminar report. Submitted in partial fulfillment of the requirement for the award of degree Of Mechanical

HEAVY REFRIGERATION MECHANIC// SR. HEAVY REFRIGERATION MECHANIC

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2" to 4" lines up to 75' N O T F O R R O O T S

Design of a Low capacity Evaporator of a Refrigeration Unit

LABORATORY SAFETY. Discipline of Metallurgy Engineering and Materials Science Indian Institute of Technology (IIT) Indore DECLARATION

Drying rate 1. Section B to C of the curve, known as the constant rate periods, represents removal of unbound water from the product.

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Chapter 11 HEAT EXCHANGERS

OPERATING MANUAL UNIT 8 - WHITEBRIDGE INDUSTRIAL ESTATE STONE STAFFORDSHIRE ST15 8LQ ENGLAND TEL: +44 (0) FAX: +44 (0)

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

THERMODYNAMIC PERFORMANCE EVALUATION OF AN AIR-AIR HEAT PIPE HEAT EXCHANGER

S water = J/gC

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Jet Cooker with Pump and Hydro-heater

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

PRINCIPLES OF HEATING, VENTILATION AND AIR CONDITIONING with Worked Examples

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Global Journal of Engineering Science and Research Management

LAB EQUIPMENT DETAILS

Evaporation studied on a duplicated vessel, pilot scale evaporator equipped with a heat pump

Section 9. Comparing Energy Consumption: More for Your Money. What Do You See? What Do You Think? Investigate. Learning Outcomes

PORTABLE HAND POWER THREADER 1/2-2

In this issue of the Environmental Health and Safety (EHS) Listserv, December 15, 2011:

Accessories. Safety Warnings. Table of Contents

High-Velocity Floor Fan

DESIGN AND ANALYSIS OF AIR CONDITIONING CUM WATER DISPENSER SYSTEM

CF35 # INSTALLATION & OPERATION

Bread Slicer, Countertop STANDARD OPERATING PROCEDURE

WL 110 Series. Heat Exchanger with Supply Unit EQUIPMENT FOR ENGINEERING EDUCATION

HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

WizCG grinder. WizlingCG grinder INSTRUCTION MANUAL

Safety In Chemistry. Identified Risks and Hazards

1. Conduct yourself in a responsible manner at all times in the laboratory.

Transcription:

Safety Hazards Thermal Systems Laboratory Rooms 106 & 110 Rotating Equipment Be aware of pinch points and possible entanglement Personal Protective Equipment: Safety Goggles; Standing Shields, Sturdy Shoes No: Loose clothing; Neck Ties/Scarves; Jewelry (remove); Long Hair (tie back) Projectiles / Ejected Parts Articles in motion may dislodge and become airborne Personal Protective Equipment: Safety Goggles; Standing Shields Heating - Burn Be aware of hot surfaces Personal Protective Equipment: Safety Goggles; High Temperature Gloves; water. Electrical - Burn / Shock Care with electrical connections, particularly with grounding and not using frayed electrical cords, can reduce hazard. Use GFCI receptacles near High Pressure Air-Fluid / Gas Cylinders / Vacuum Inspect system integrity before operating any pressure / vacuum equipment. Gas cylinders must be secured at all times. Use appropriate equipment guards. Personal Protective Equipment: Safety Goggles / Slip Hazard Clean any spills immediately. Noise Personal Protective Equipment: Use Rated Ear Plugs

ME 406: Experiment 6 Performance Test of a Concentric Tube Heat Exchanger I. Objective: To evaluate the performance of a concentric tube heat exchanger in parallel flow (cocurrent flow) and counter flow under variations of high temperature and low temperature flow rates. II. Background A concentric tube heat exchanger is composed of a tube, through which one fluid flows, located concentrically inside another tube. The other fluid flows through the annular region between the two tubes. In this heat exchanger, the hot fluid (water) flows through the inside tube and the cold fluid (water) flows through the annular space. For parallel flow, both hot and cold water enters the same end of the heat exchanger. T ci = cold water inlet Temperature T co = cold water outlet Temperature T hi = hot water inlet Temperature T ho = hot water outlet Temperature Cold In Hot In T hi T ci T 1 T 2 Hot Out Cold Out T ho T co T 1 = T hi T ci T 2 = T ho T co

For counter flow, the hot water enters one end of the heat exchanger, the cold water enters the opposite end. Hot In Cold Out Hot Out T hi Cold In T 1 T ho T co T 2 T ci Since the temperatures of the hot and cold water vary over the length of the tubes, the temperature difference, T = T h - T c, is not constant over the length. To account for the variation, a Log Mean Temperature Difference (LMTD) is used. T 1 - T 2 LMTD = ln( T 1 / T 2 ) The rate of heat transfer from the hot water to cold water is then given by; Q = UA*LMTD UA = Q/LMTD Q = heat transfer rate (kj/min) U = overall heat transfer coefficient (kj/min-m 2 - o C) A = Hot water tube surface area (ft 2 ) NOTE: It is possible that for counter flow, T 1 = T 2. In that case, Q = UA*(T hi T co ) or Q = UA*(T ho T).

Applying the First Law of Thermodynamics, to the hot water side, Q h = M h C h (T hi T ho ) to the cold water side, Q c = M c C c (T co T ci ) M = mass flow rate of water (kg/min) C = specific heat of water (kj/min-kg- o C) With negligible losses to the surrounding air from the cold water, Q c = Q h If the tube surface area is based on inside diameter, (A i = πd i L), then U = U i. If the tube surface area is based on outside tube diameter, (A o = πd o L), then U= U o. Using a 1 dimensional steady state analysis for cylindrical surfaces, the total thermal resistance, R t, is the sum of the hot water convection resistance (R h ), the tube wall conduction resistance (R w ), and the cold water convection resistance (R c ). R t = R h + R w + R c R h = 1/h h A i (hot water convection resistance) R w = ln(d o /D i )/2πkL (tube wall conduction resistance) R c = 1/h c A o (cold water convection resistance) k = tube wall thermal conductivity h = convection heat transfer coefficient The convection heat transfer coefficients can be determined from empirical relations for Nusselt Number (Nu) for flow through a tube, (hot water side), and flow through an annulus, (cold water side). The overall heat transfer coefficient is related to the total thermal resistance as, U i A i = U o A o = 1/R t Heat exchanger effectiveness, ε, is defined as, M h C h (T hi - T ho ) M c C c (T co T ci ) ε = = MC min (T hi T ci ) MC min (T hi T ci ) MC min = minimum of either M h C h or M c C c.

The number of transfer units (NTU) for a heat exchanger is defined as, NTU = UA/MC min

The effectiveness of the heat exchanger is a function of heat exchanger NTU, represented typically by the graph below. ε C* C * = MC min /MC max NTU Empirical relations for the above are; Parallel Flow Counter Flow 1 exp[-ntu(1 + C * )] 1 exp[-ntu(1 C*)] ε = ε = 1 + C * 1 C*exp[-NTU(1 C*)] In the special case of C* = 1 Parallel Flow ε = ½ [1 exp(-2ntu)] Counter Flow ε = NTU/(1 + NTU) III. Equipment Armfield HT30X Heat Exchanger Apparatus Hot Tube Di = 0.0083 m Do = 0.0095 m L = 0.660 m Stainless steel Computer/Software Armfield HT31 Tubular Heat Exchanger Log in Username: student Log in Password: meclab

IV. Procedure 1. Make sure the drain valves for the refrigeration apparatus and convection apparatus are closed 2. Open drain valve for the heat exchanger apparatus 3. Check that the 3-way valve on the heat exchanger is in the cocurrent (parallel flow) arrangement. If not, set the valve that way. 4. Turn on the computer, log in, and open the HT31 Tubular Heat Exchanger. 5. Open exercise D Overall Heat Transfer Coefficient. 6. Click through the, Walk through presentation, (procedure and questions can be ignored). 7. Make sure the hot water reservoir is primed (full). If not, fill the reservoir up to the overflow. 8. Turn on the power to the HT30X apparatus 9. Set the temperature controller on the HT30X to 60 o C by pressing SET and the up or down arrows. 10. Turn on the cooling water supply (main valve and heat exchanger apparatus water valve). 11. Switch on the hot water toggle switch (from 0 to 1) on the HT30X. 12. On the computer Results screen, make sure the radio button for flow orientation is set to the appropriate cocurrent (parallel flow) or counterflow orientation. 13. Adjust the hot water flow valve to 1 L/min. 14. Adjust the cold water flow valve to 3 L/min. 15. Allow the temperatures to stabilize (monitor on the computer Results screen), then click on Sample Now. 16. Adjust the cold water flow valve to 2 L/min. 17. Allow the temperatures to stabilize (monitor on the computer Results screen), then click on Sample Now. 18. Adjust the cold water flow valve to 1 L/min. 19. Allow the temperatures to stabilize (monitor on the computer Results screen), then click on Sample Now. 20. Adjust the hot water flow valve to 2 L/min. 21. Repeat steps 14 to 19. 22. Adjust the hot water flow valve to 1 L/min. 23. Repeat steps 14 to 19. 24. Turn off the hot water toggle switch. 25. Turn off the cooling water flow valve. 26. Turn the 3-way valve to the counter-flow orientation, change the radio button to counter-flow. 27. Repeat steps 10 to 25. 28. Turn off hot water toggle switch, HT30X power, cooling water main supply valve and heat exchanger water supply valves. 29. The results in the Results table can be saved to a floppy disk or emailed.

V. Analysis 1. Calculate the Overall Heat Transfer Coefficient (U) using measured values. Compare these to the U s calculated using the empirical equations. 2. Determine the NTU and ε for each flow orientation and flow rate combination. 3. Plot the ε versus NTU for each flow orientation. 4. Compare the ε calculated from measured values to those calculated from empirical equations.