Weed Model N9013. Surface Mount Thermocouple. Nuclear Qualified

Similar documents
EXCELLENCE in Solutions Products Service

High Performance Heater with More Efficient Heat

Weed Instrument The Only Name You Need to Know for Temperature Measurement

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Light Duty Commercial Electric Water Heater

VACUUM VALVES AND HOSES

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Indirect Fired Water Heater

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

Weed Instrument Application Driven Designs for Pharmaceuticals and Biotech

W A T L O W. Straight Resistance Wire. Welded End Cap

SECTION SPRINKLER SYSTEMS

DI/RO GAS TANKLESS WATER HEATER

INSTALLATION INSTRUCTIONS

Shipboard Electric Water Heater

Mineral Insulated Band Heater

Thermostat Catalog 2004

Temperature Sensors & Compression Seal Fittings

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames

108A OTP1800. Grid Support. General Description

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Continental Industries STEEL COUPLINGS or FAX Visit

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Instrumentation for Nuclear Applications

SPECIAL THERMOCOUPLES IN STOCK - TYPE J AND K STYLES. DESCRIPTION (Includes 1/8 NPT Compression Fitting) PART # PRICE

Sensor Wiring Instructions and Approval Drawings

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

February 21, 2003 Team Page 1

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Immersion Heaters. Screw Plug Immersion Heater

NATURAL GAS PIPING

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

TWIP Level Switches. Water Detection for Alarms, Trips, Drain Pot, Heaters, Deaerators, and Condensate Tank Applications

W A T L O W. Straight Resistance Wire. Welded End Cap

Nuclear Electric Heating

Temperature Sensors & Compression Seal Fittings for Semiconductor Processing

Flexible Power Cable DLO

the next generation thermometer from the global leader

BAGI - MIXER. Magnetically Driven Bottom Mounted Mixers. Sealless ZERO LEAKAGE Design. CIP / SIP Capable. Non Contaminating Mixing

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

MAC N-407 Air-Cooled Chiller

Jan05 Rev A EC

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Two Circuit Heavy Duty Burner Connector

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

y Small dimensions. Easy to install in refrigerated counters or cold rooms

MACH N-407 Heat Pump Air-Cooled Chiller

Table of Contents. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction 3.0 TEST PROGRAM 2

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

K4RH(X) Solids-Handling Pumps

Cartridge/Insertion Heaters

temperature Controllers

SECTION FAN COIL UNITS

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications

The next generation thermometer from the global leader

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

Thermostat Catalog 2004

SPECIAL THERMOCOUPLES IN STOCK - TYPE J AND K STYLES. DESCRIPTION (Includes 1/8 NPT Compression Fitting) PART # PRICE

T7079A,B Solid State Remote Temperature Controllers

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

mtc001 Thermocouple Converter

Ceiling Mount Temperature Sensor

Renewable Energy. System Solutions

Coil Heaters. Design Features: Typical Applications: Coil Heaters

Ramsey Motion Monitoring Systems

Nozzle Band Heaters. Construction Characteristics. Single Port Igloo TM Covers

Cartridge/Insertion Heaters

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Packaged Semi-Instantaneous Steam Fired Water Heater

Machining: Moderate to Extensive. Pattern Shop

PORTABLE DEW POINT MONITOR

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

Cartridge. SORB-AC Cartridge Pumps MK5 Series. Pump Body. Heater. Thermocouple. Flange. Electrical Connector

Machining: Moderate to Extensive. Pattern Shop

Standard Heat Treating Equipment Product Catalogue

INSTRUCTION MANUAL with Replacement Parts

Dual Column Dehydrating Breather Manual

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

TECHNICAL INSTRUCTIONS

FLT93 Installation, Operation and Troubleshooting Guide

SECTION HYDRONIC PIPING

TEMPERATURE CONTROLLER

Product Catalog E-Book

M7100 Pressure Transducer

SECTION AIR COILS

Stratomaster Smart Single

24 VAC SYSTEM CONTROL KIT

SERVICE PARTS for ECO353N

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

DGH Series Global Air Treatment

Mineral Insulated Band Heaters

Transcription:

DELIVERING CRITICAL MEASUREMENTS Nuclear Qualified Weed Model N9013 Surface Mount Thermocouple Strap-on Mounting Thermocouple Types: J, K, T and E IEEE 323-1974 & 1983, IEEE 344-1975 & 1987 and NUREG 0588 Qualified Easy Installation & Removal Available for Non-safety Related Applications Nuclear Sensors & Process Instrumentation

Weed Model N9013 Surface Mount Thermocouple Ultra Electronics, Nuclear Sensors & Process Instrumentation s (NSPI) Model N9013 thermocouple strap-on temperature sensor is very convenient for the measurement of surface temperatures of tanks, pipes, motors, bearings, and various other surface mount applications. The easy strap-on installation method makes it very cost effective to use the Model N9013 for temporary, semipermanent or permanent temperature measurements. The N9013 has been environmentally and seismically qualified for use in 1E applications in nuclear power generating stations. The N9013 can be ordered as non-safety related, offering the same reliability and construction as the safety related version but at a much lower cost. NSPI thermocouples are supplied in accordance with NSPI s Quality Assurance Program which is ISO 9001 Registered. The program is also in compliance with 10CFR50 Appendix B, ANSI N45.2 and ASME NQA-1. Application assistance is available for special applications and design requirements. Assistance includes physical configuration requirements such as leadwire length, quick disconnects and other physical details. Actual installation details can affect measurement accuracy and response time. Such things as thermocouple contact with the surface, surface cleanliness and isolation from ambient temperatures may cause variations in accuracy and response times. For the best performance consult NSPI for application assistance. 2

Weed Model N9013 Surface Mount Thermocouple Thermocouple Specifications Thermocouple Type Wire Material Wire Insulation Color (ANSI) Temperature Range ANSI Standard Limits of Error J Iron (+) Constantan (-) White 32 to 1400 F 0 to 760 C ±2.2 C or 0.75% K Chromel (+) Alumel (-) Yellow 32 to 2300 F 0 to 1260 C ±2.2 C or 0.75% T Copper (+) Constantan (-) Blue 0 to 700 F 0 to 370 C ±1.0 C or 0.75% E Chromel (+) Constantan (-) Purple 32 to 1600 F 0 to 870 C ±1.7 C or 0.5% Tolerances do not include system or installation error. Performance Specifications Item Specifications Accuracy Thermocouple accuracy is defined in Standard ASTM E230. Insulation Resistance Environmental/Seismic Qualification (Applicable Qualification/ Test reports are available upon request) At room temperature and dry external surfaces, the insulation resistance between any terminal and the sensor case will exceed 10 Megohms with 100 VDC applied (ungrounded and exposed tip only). Thermocouples are qualified to IEEE-323 1974 & 1983, and IEEE-344 1975 & 1987 and NUREG 0588 for a design life of 40 years. The thermocouple assembly will withstand 300 Megarads T.I.D. and LOCA conditions. Thermocouples are capable of surviving a maximum combined horizontal and vertical seismic acceleration of 20 g s within a range of 1 to 33 Hz. General Specifications Torque Torque to tighten the standard heavy duty hose clamp is 60 to 84 inch pounds Storage Storage of the thermocouples should be in accordance with ANSI N45.2 Level B Shipping Weight Approximately 0.75 pounds with one foot of flex tubing 3

Dimensional Drawings POLYOLEFIN INSULATED STRANDED CONSTANTAN EXTERNAL LEADS WITH POLYOLEFIN JACKET 3.0" (REF.) 1/2 NPT SEAL WELD OR BRAZED TO FITTING "xx" TUBE SOCKET WELD MALE CONNECTOR 45 L WORM DRIVE CLAMP OR CONSTANT TORQUE CLAMP SENSOR HOUSING (SEE DETAIL -A-) WIRING DIAGRAMS TERMINAL BLOCK EXTENSION WIRE TERMINAL BLOCK EXTENSION WIRE THERMOCOUPLE THERMOCOUPLE 4

Weed Model N9013 Surface Mount Thermocouple 5

Ordering Information N9013 S D Surface Mount Thermocouple Single, 2 wire Dual, 4 wire Type J K T E Iron - Constantan Chromel - Alumel Copper - Constantan Chromel - Constantan Junction Type G U B Grounded Ungrounded Exposed tip Flexible Tubing Length L Inches Leadwire Length (after exiting flexible tubing) XX Inches N9013S J G 12.0 4.0 (Example Model Number) Nuclear Sensors & Process Instrumentation DELIVERING CRITICAL MEASUREMENTS Ultra Electronics NUCLEAR SENSORS & PROCESS INSTRUMENTATION 707 Jeffrey Way, PO Box 300 Round Rock, TX 78680-0300 USA Tel: +1 512 434 2950 Fax: +1 512 434 2951 Email: nuclear@ultra-nspi.com www.ultra-nspi.com This document is not intended to serve as a design document and is subject to change. Actual specifications are per customer order. Ultra Electronics reserves the right to vary these specifications without notice. Ultra Electronics 2016. Printed in USA Rev. 1, Pub. 0015-002-1108 05/16