OPERATING INSTRUCTIONS

Similar documents
2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE

1909/1910 QUICK START GUIDE. Simpler Soil Water Samplers 02/2018. Fig. 1 - Model 1910LL Fig. 2 - Model 1910PL Fig. 3 - Model 1909L

MEASURING A WORLD OF DIFFERENT SOILS SOIL WATER RETENTION CURVES

04.SOIL MOISTURE MEASUREMENT

English Manual for Jewelry Casting and Investing The professional choice

Unit 21 Charles's Law. Procedure

Chemistry Materials Separation Processes

SECTION METERS AND GAGES FOR HVAC PIPING

HH80C HYDRAULIC CRIMP TOOL

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

Models Goldfisch Fat Extraction Apparatus

Science Lab Equipment

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Troubleshooting the MPH 24FP Series Pedestal Hydrant

COMMERCIAL ELECTRIC WATER HEATER OWNER S MANUAL OPERATION AND MAINTENANCE INSTRUCTIONS

MKV MILK METER ICAR approved TECHNICAL MANUAL. Part Number: Waikato Milking Systems NZ Ltd, 2006

OPERATING INSTRUCTIONS

FRESH HEAD. MANUAL TOILET for pressurized fresh water rinse INSTALLATION AND MAINTENANCE INSTRUCTIONS

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

TUBULAR LLdia-PUMPyy INSTRUCTIONS

FRESH HEAD. MANUAL TOILET for pressurized fresh water rinse INSTALLATION AND MAINTENANCE INSTRUCTIONS

7800 Neutralizer Installation & Start-Up Guide

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

Clean Water Made Easy

Test Tube Rack. Test Tube

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC015 - AC016 - AC018

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

CryoProbe System. Pneumatic Vacuum Operator User Manual. Version

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

26/06/2018 USER MANUAL HOBBY 100 GPH REVERSE OSMOSIS. All Rights reserved Les Équipements d Érablière CDL inc.

DRY 150 Quest PowerDry 1300

Clean Water Made Easy

CHILLER. Operator s & Installation Manual

Movement of soil water- Infiltration, percolation, permeability Drainage -

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

FLECK 5600 WATER SOFTENER INSTALLATION

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Ink Degasser for Pro-HP Bulk System Installation and Operation Manual

Determination of the enthalpy of vaporization of liquids

COVER PLATE GREY PLASTIC OR OPTIONAL SOLID BRASS DIAL

Operation Manual R205BV, R209BV

Owner s Manual. Terpene Trap CF 1000

SOILS SPEEDY 2000 MOISTURE TESTER MICROWAVE MOISTURE METER PERMEAMETER MODELS MODELS DESCRIPTION STANDARDS

Humidistat-Thermostat

Scheduling Irrigation for Horticultural Crops. Patrick Byers Regional Horticulture Specialist Greene County

Scheduling Irrigation for Horticultural Crops

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

Cabinet Non-Electric Water Softener

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

R Series Cooling Modules

User Instructions. Visit us at us at RB5, RB10, RB15 Maple Sap Buckets

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions


5700-E Sediment Filter Installation & Start-Up Guide

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Laboratory Equipment. Section 1L. Chemistry I & II

Clean Water Made Easy

0 to 175 centibars (kilopascals)

Installation and Owners manual

OPERATING INSTRUCTIONS

Coffee Shop. Soil Moisture Monitoring

OPER LV Wheeler Way

20 TON AIR/MANUAL SHOP PRESS

Global Water Instrumentation, Inc.

Above Ground Pool Solar Heating System

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

INSTANT-FLOW C-MICRO WATER HEATER

RK/ RK Oxygen Detector Operator s Manual

REVISION STATUS AMENDED PAGES. Initial release D. All

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

Fleck 7000 Sediment Filter Installation & Start-Up Guide

PULSE JET DE-ICER OPERATING MANUAL SETUP OPERATION MODEL PJDX-C (REV B) Mode Adjustment Knob WATER SERVICE LINE THAWER FLOW MODE PULSE MODE

BAXTER: FACTOR VII 600 IU (Plasma Derived)

Scotsman Technical Training. CU50 Cube Ice Machine

TABLE 1 Electrical Specifications

Parts & Material Included

26/06/2018 USER MANUAL OSMOSE HOBBY GPH. All rights reserved Les Équipements d Érablière CDL inc.

Installation and User's Manual for Cuber Model CU0515

92831 TEL: (714) FAX:

- 1 - Updated on 18 March, 2010

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

ASPIRE Laboratory Aspirator

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

RCM Refrigerant Module

OPERATING AND MAINTENANCE MANUAL

NEW Restek Electronic Leak Detector

TABLE 1 Electrical Specifications. Phase

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

OWNER S INSTRUCTION & INFORMATION

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

Hg5 Amalgam Separator Installation and Operations Manual

NOTICE TO INSTALLER: Instructions must remain with installation. FW Supersedes HomeGuard OPTIMA

Transcription:

OPERATING INSTRUCTIONS 2005G2 Vacuum Hand Pump July 2008 (Figure 1) Vacuum Hand Pump with Accessories The 2005G2 Vacuum Hand Pump is a convenient and easily operated vacuum device0. It is designed for air and/or water, pulled in at the front and exhausted through the upper side fitting located directly below the handle end of the pump. Not only will the pump pull a vacuum in short order, but due to the exceptional sealing of the valves, will maintain a large evacuated volume over an extended period of time. 1

WARRANTY & LIABILITY Soilmoisture Equipment Corp. (SEC) warrants all products manufactured by SEC to be free from defects in materials and workmanship under normal use and service for twelve (12) months from the date of invoice provided the section below has been met. Soilmoisture Equipment Corp. (SEC) is not liable for any damages, actual or inferred, caused by misuse or improper handling of its products. SEC products are designed to be used solely as described in these product operating instructions by a prudent individual under normal operating conditions in applications intended for use by this product. PARTS 2 1 3 5 4 (Figure 2) Hand Pump Kit List (Assembled) Item # Part # Description 1. MML010 Utility Hand Pump 2. 2060FG3 Vacuum Dial Gauge Recalibrator Style 3. 2005-007 Hose, 3/16" ID X1/8" wall, 2 ft. long 4. 2701-001 Service Cap 5. 2029 Gauge adjusting screwdriver SPECIFICATIONS Capable of developing vacuums to 90 centibars (90 kilopascal) Rugged portable design for prolonged use in the field, brass and rugged elastomers. Use for air primarily and water Each pumping stroke = 86 ml / stoke volume of air or water Recalibrator style gauge 0-100 cbar Hose and service cap for use with standard Soilmoisture tensiometers 2

A PUMP WITH MANY PURPOSES The 2005G2 Vacuum Hand Pump is used for servicing all varieties of standard Soilmoisture Tensiometers; Model 2710 Soilmoisture Tensiometer, the Model 2725 Jet Fill Tensiometers and all other types that use our quick thread top connections. It can be used for a many other purposes from checking out Soil Water Samplers and evacuating them to work with portable vacuum extraction systems. The pump will find a number of handy uses. FOR USE WITH OUR TENSIOMETERS (Figure 3) Pulling water into the tensiometer (Figure 4) Removing air from gauge (Figure 5) Ready for use As shown in (Figure 3), the first item of business is in pulling water into the tensiometer. First, boil some water (it helps remove the entrapped air), let it cool in a container. Place the tensiometer in the container and create a vacuum in the tensiometer by slowly pulling the handle on the 2005G2 Vacuum Hand Pump. This brings water up through the ceramic cup, through the interior of the tensiometer and finally into the cap. Air will also begin to come out of the gauge. Pull in a bit more water until the big bubbles stop. Remove the tensiometer from the bucket (Figure 4) and pull a high vacuum of 80 cb. on the hand pump and watch as air comes out of the gauge. Insert back into the bucket and repeat the process of pulling water into the tensiometer. Again, remove the unit and pump and draw another high vacuum to evacuate more air. This purging of air from the gauge is an important step in making the tensiometer sensitive to its placement in the soil. Once installed in the soil, as shown in (Figure 5) on a Model 2710 Soilmoisture Tensiometer, remove the cap for a short period of time. This allows water to move out of the unit and into the soil. Attach the 2005G2 Vacuum Hand Pump to your Model 2710 Soilmoisture Tensiometer, and once again pull a moderate vacuum, this pulls back some of the water allowed to go into the soil and establishes a good working hydraulic relationship between the soil pore water. (For more on this procedure consult the instruction manuals for the Model 2725 Soilmoisture Tensiometer or Model 2710 Soilmoisture Tensiometer.) 3

FOR USE WITH OUR SOIL WATER SAMPLERS (Figure 6) Checking the sampler for leaks (Figure 7) Taking a pore water sample (Figure 8) Withdrawing a Sample The 2005G2 Vacuum Hand Pump is essential when working with our 1900 Series Soil Water Samplers as shown above. Prior to (Figure 6), the soil water sampler must be placed in a container of water (letting the ceramic cup wet 15 min.) Pour the excess water out of the sampler, place the stopper on top of the sampler and connect the hose to the outlet stem of the stopper, use the hand pump to pull a vacuum of 60 cb. on the wetted sampler. The sampler should maintain this vacuum for 7-10 minute period, assuring a leak free assemblage prior to installation. In (Figure 7) the soil water sampler has been installed and is being prepared to take a sample. After pulling a vacuum at 60 kpa (cb), remove the hand pump, place a clamping ring on the tube and leave the sample alone for 24-48 hours. The suction within sampler will pull in pore water (with a force less than 60 kpa) from surrounding soil pores directly into the sampler. In (Figure 8) the pore water volume collected by the sampler is being transferred by applying a slight vacuum. The Erlenmeyer flask decants the liquid from the sampler into the flask for later lab analysis. (If you'd like to know more, consult our installation and instruction manuals for our extensive line of 1900 Series Soil Samplers.) 4

FOR USE WITH MODEL 2900 QUICK DRAW PROBE Model 2790U1 Filling Fixture (Figure 9) Filling the Probe with water (Figure 10) Evacuating air from the Probe Gauge The Model 2900 Quick Draw Soilmoisture Probe is a natural when used with the 2005G2 Vacuum Hand Pump. For this job we recommend the Model 2790U1 Filling Fixture used in conjunction with the 2005 pump. The Model 2790U1 Filling Fixture allows water to be slowly drawn from the tip up through the internal capillary tubing, the gauge and into the filling fixture. The filling fixture provides a reservoir of water as air is purged from gauge after filling. As shown with the tensiometer earlier, the Model 2900 Quick Draw Soilmoisture Probe (a modified tensiometer) absolutely requires a filling - purging cycle. To accomplish the filling one takes a water container and inserts the porous ceramic tip into the water and create a moderate suction of 40-50 kpa (40-50 cb) at the end of the probe body as shown in (Figure 9). To purge or remove entrapped air from the probe gauge you need to remove the probe from the water and lay on a flat surface as shown in (Figure 10). A very high vacuum of 80-90 kpa (80-90 cb) is placed on the filling fixture and you will see air as bubbles coming into the water remaining filling fixture. The high vacuum is removed and water from the fixture is taken into the probe. Again, a high vacuum is applied and more air removed. This is done a number of times 5-6 times to remove all the air from the system. The filling fixture and the hand pump are removed, the probe body filled with water and a null knob (not shown) is then inserted into the fully filled probe body and slowly screwed in as extra water is pushed out the ceramic tip at the end of the probe. A sensitive hydraulic probe, properly serviced, when set to 80 kpa with the null knob will go from 80kPa to 0 kpa in less than 3 seconds. (For more on this procedure please consult the Model 2900 Quick Draw Soilmoisture Probe operating instructions.) 5

FOR USE WITH PORTABLE EXTRACTOR SYSTEM (Figure 11) Model 1300 Filter Funnel Kit (Figure 12) Model 1428 Tempe Kit Whether it s a portable Model 1300 Filter Funnel System, as shown in (Figure 11) for on site analysis of dissolvable mineral and salt content or (Figure 12) which shows the new Model 1428 Tempe Kit, that's used in in determining the saturated conductivity or low end release curve information, the 2005G2 Vacuum Hand Pump will come in handy. Both systems need a reliable method of creating a partial vacuum of between 5kPa (5cb) to 80kPa (80cb) in any method used. The 2005G2 Vacuum Hand Pump will produce the required vacuums and assure that the values remain in the sample containers used in the systems. Simply connect the hose and pull the partial vacuum wanted and that s all there is to it. CHECKING CALIBRATION TENSIOMETER DIAL GAUGES USING THE 2005G2 VACUUM TEST HAND PUMP The 2005G2 Vacuum Hand Pump should always be kept in mind as a handy calibration device for any and all tensiometers having similar vacuum gauges. When applying a partial vacuum both the hand pump and the device being evacuated should read the same kpa (cb) values assuring that both the instruments are reading correctly in the field. Many times with an early winter frost the gauge bourdon tube can become distended and distorted by water inside freezing. The gauge may look alright but will read poorly or erratic. Using the hand pump as seasonal check for functionality prior to an install is always a good idea. 6

HELPFUL HINTS AND MAITENANCE When the 2005G2 Vacuum Test Hand pump is used for air removal or pulling a vacuum, very little maintenance of the unit is required. REPLACEMENT PARTS (Figure 13) 2005G2 Vacuum Hand Pump Replacement Parts ITEM PART # DESCRIPTION 1. Z2005-003 Plunger valve-assembly 2. Z2005-004 Intake Valve 3. Z2060FG3 Vacuum Dial Gauge 4. Z2005-001 Adapter Fittings 5. ZMML010-005 Rod 6. ZMML010-004 Top Cap 7. ZMMl010-003 Brass Tube 8. Z2005K1 Intake Cap 9. ZMML051 Check Valve 10. ZMM1010-002 Handle 7

With dealers throughout the world, you have convenience of purchase and assurance of after-sales service. COPYRIGHT 2008 ALL RIGHTS RESERVED 0898-2005G2 8