D7052. Installation Instructions Multiplex Dual Input Module

Similar documents
D7044. Installation Instructions Multiplex Single Input Module

D7053. Installation Instructions Multiplex Input/Output Module

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

DS7465i. Installation Instructions. Input/Output Module

Addressable NAC Output Module D327A

Multiplex Eight Input Remote Modules

F220-B6PS/M. Installation Guide. Addressable Detector Bases

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

Notification Appliance Circuit Module

FMR Installation Instructions. Addressable Fire System Controller

D250A/D253/D261AW/D280A/D290 Series

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Duct smoke housings, 4-wire D341/D341P and D342/D342P

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

D7024 Fire Alarm Control Panel

Remote NAC Power Supply D7038

Duct smoke housing, 2-wire D340/D340P

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

D343. Installation Instructions. Air Duct Smoke Housing

These instructions detail procedures to follow in order to avoid damage to equipment.

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Battery charger modules

D1255RB/D1256RB/D1257RB

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Commercial Series TriTech Motion Detector. Reference Guide

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

FireNET Plus Wiring Instructions

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

RELEASE DEVICE CONTROLS

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

Fire Alarm Control Panels FPD-7024

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Addressable Fire Alarm Control Panel

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Booster Power Supply Manual

D2071A. Operation & Installation Guide Fire Alarm Control Panel

Operation and Installation Guide. Zone Expansion Module D8125

Commercial Series TriTech+ Motion Detector with Anti-mask

Conventional Smoke Detectors KFAPO

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

1. POWERPATH Operation

Fire Control/Communicator

DS7400Xi Addressable Control/ Communicator

Print Specification. Publication. Instructions. Specific requirements. General requirements

UEI-1 UNIVERSAL END-OF-LINE / ISOLATOR TESTER

30.45 Electric Release PDRP-2001

SIGA-CC1 Single Input Signal Module Installation Sheet

D720 and D1255 Command Centers

July 14, 1999 DF C-100.

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

DS160/161 Request To Exit PIR sensors Installation Instructions

Independent Zone Control (I.Z.C.)

Protecting Lives and Assets FPD-7024 Fire Alarm Control Panel

LifeAlarm Fire Alarm Controls

June 10, 2002 DF C S2424

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

Addressable Detectors & Bases

4100U City and Relay Cards Installation Instructions

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Bosch EVAX System - High-rise Applications

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

TrueAlarm Analog Sensing

Easy Series ICP-EZM2. System Reference Guide

INSTALLATION INSTRUCTIONS

Signature Series Auto-Sync Output Module (CC1S)

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

FX-PDD Duct Smoke Detector Installation Sheet

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

MANUAL RESET ALARM RELEASE

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

TrueAlarm Analog Sensing

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Control Relay Modules

D296/D297. Application Guide. Projected Beam Smoke Detectors

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

D7212GV2. Operation and Installation Guide. Control Panel

MANUAL RESET ALARM RELEASE BOX

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Input/Output Modules Data Sheet

Installation Guide. Control/Communicator

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

TrueAlert Notification Appliances

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Remote Booster Power Supplies

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Transcription:

D EN Installation Instructions Multiplex Dual Input Module

D Installation Instructions Notices Notices Figure : D Features These instructions cover the installation of the D Multiplex Dual Input Module in a fire system supervised by a D or DSM Fire Alarm Control Panel (FACP) with firmware revision. or greater and a D or DS Multiplex Expansion Module. Install, test, and maintain the D according to these instructions, NFPA, local codes, and the Authority Having Jurisdiction (AHJ). Follow the procedures in these instructions to avoid personal injury and damage to equipment. Failure to follow these instructions can cause the D to not operate properly. Bosch is not responsible for improperly installed, tested, or maintained devices. A B Test the FACP according to NFPA.. Description The D (Figure ) is a general purpose module that connects to the multiplex bus of the control panel. It provides two supervised Class B input zones or one Class A input zone. Use a jumper pin setting for a Class A or Class B wiring configuration. All operating power for the D is drawn from the control panel. Rotary switches provide convenient address setting. An on-board Status LED, visible through the faceplate, indicates normal operation and communication with the control panel. The LED flash rates are: Fast: Approximately sec indicating an alarm condition. Medium: Approximately sec indicating a normal operation. Slow: Approximately sec indicating a trouble condition. The D can be mounted in a standard double-gang or a in. x in. electrical box. - Status LED - Class A and Class B jumper pins - MUX bus loop terminals - Zone input terminals - Rotary address switches. Setting the Address Set the D address using a flat-blade screwdriver to position each rotary switch located on the front of the module (Figure ). Note that the switches click when turned. Figure : Setting the Address A B - Hundreds - Tens - Ones A = D FACP, B = DSM FACP For example: hundreds, tens, ones = Address on the D FACP The valid address range is to. Refer to the D Operation and Installation Guide (P/N: ) or the DSM Reference Guide (P/N: ) for additional address limitations. The D requires two program addresses. The address cannot be or a multiple of, such as,,, and so on. Bosch / F

D Installation Instructions. Wiring The A address range works on the D Multiplex Expansion Module with the D FACP. The B address range works on the DS Multiplex Expansion Module with the DSM FACP. Figure : Class B Wiring Connections Figure on page shows the input address set at. The second input address will be set to the next consecutive address,. Because the hundreds address is within the input address range, it works on the D with the D FACP.. Wiring Remove all power before making electrical connections. Failure to do so can result in personal injury and damage to the equipment. Use normally-open (NO) contacts for Underwriters Laboratories, Inc. (UL) Listed fire installations. The wiring connections are made using the terminals on either side of the D (refer to Figure on page ). All terminals can accommodate up to and including AWG (. mm) wire. Follow the wiring guidelines as specified by NFPA- and the local AHJ. All wiring is power limited and supervised. Refer to Figure and Figure for the two types of wiring connections. Ensure the D is correctly configured for Class A or Class B. Refer to Figure for jumper settings. A B -. kω end-of-line (EOL) resistor, UL Listed (P/N: ) - Input Zone - Input Zone - Zone in (+) - Zone in (-) Note: The maximum zone wire resistance = Ω Figure : Loop and Control Panel Wiring Connections Figure : Class A Wiring Connections - Zone in (+) - Zone in (-) Note: The maximum zone wire resistance = Ω A B - Class A and Class B jumper pins - Class B - Class A - MUX bus loop (+) - MUX bus loop (-) - To next device - From previous device, the D, or the DS Bosch / F

D Installation Instructions. Installation. Installation Complete all wiring before installing the D and faceplate.. Wire the D according to Figure or Figure on page.. Set the Class A and Class B jumper pins (Figure on page ).. Mount the D on a standard double-gang box (Figure ) or in. x in. electrical box (Figure ). Figure : Mounting the D to a Standard Double-Gang Box A B - Screws () - not supplied - D Module - Double-gang box Figure : Mounting the D on an Electrical Box A B - Screws () - not supplied - D Module - in. x in. electrical box Bosch / F

Bosch / F D Installation Instructions. Installation D A B - Supplied screws () - Faceplate - D Module on electrical box Figure : Mounting the Faceplate. Secure the faceplate to the front of the D (Figure ).

D Installation Instructions. Specifications. Specifications Table : Specifications Control Panel Programming Type Control Panel Requirements Multiplex Bus Average Current Draw Operating Temperature Relative Humidity Listings and Approvals Class B : Dual input Class A : Single input D or DS Series FACP with ROM v. or greater and a D or DS Multiplex Expansion Module installed. Refer to the D Operation and Installation Guide (P/N: ) or the DSM Reference Guide (P/N: ) for specific programming information. Refer to the D Installation Instructions (P/N: ) of the DS Installation Instructions (P/N: ) for multiplex wiring information. Alarm: µa Standby: µa Nominal: V C to + C (+ F to + F) % non-condensing UL California State Fire Marshall (CSFM) Bosch / F

D Installation Instructions Notes Notes Bosch / F

Bosch Perinton Parkway Fairport, NY - USA Customer Service: () - Technical Support: () - Bosch F