SMITH STAINLESS FLOOR DRAIN SERIES - CAST

Similar documents
MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

Type A. Part # Description

Protected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

2015 UPC Chapter 8 Indirect Wastes RV

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

SECTION PLUMBING

Read Only Document Not For Distribution

DOMESTIC WATER PACKAGED BOOSTER PUMPS

O.D / 2" (444) 15 1 / 2 " (393) Maximum I.D / 4 " (336) 1 3 / 4 " (45) 1 1 / 4 " (32)

UNIVERSAL STYLE STEAM TRAPS WU450 Series

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

Liquid Drainers LIQUID DRAINERS

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Willoughby Industries - Security Products

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

EL SERIES INSTALLATION INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

THERMOSTATIC STEAM TRAPS

Installation & Operation Manual

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION WET-PIPE SPRINKLER SYSTEMS

66 Series 4ft Recessed, Surface or Pendant Mount

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SYSTEMS. 0. Pipe and pipe fittings are specified in the following sections:

APPENDIX J ILLUSTRATIONS

Canning Shed/Facility Equipment Specifications

Packaged Steam Fired Water Heater

CHAPTER 10 TRAPS AND INTERCEPTORS

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

Classic 6 & 18 Prep Procedure Tables Owner s Manual

SCREWPLUG HEATERS. immersion heaters

SECTION PLUMBING SPECIALTIES

Willoughby Industries - Security Products

OPERATING AND MAINTENANCE MANUAL FOR BOILER WATER OR HIGH TEMPERATURE HOT WATER (HTHW) POWERED WATER HEATER

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Products + Accessories. Kitchen, bathroom, bar sinks, bathtubs, barware, accessories, and more.

Specialty Products SUCTION/MIXING TEES

Flange Heaters Type CX

Is Sewer Gas Giving Your Customers the Wrong Impression?

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Price Sheet 104. Dilution Tanks/Traps 1/1/2019

1-1/2 gallon square dilution tank, 1-1/2" or 2" inlet/outlet with 3" cleanout on top

CAST IRON CLAWFOOT TUB

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

GLOBAL FLOW PRODUCTS

Read Only Document Not For Distribution

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL

1 Exam Prep Plumber s Handbook Tabs and Highlights

PHCC Educational Foundation Plumbing Year 4

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

Checklist Selecting the Proper Flanged Heater

Grease Interceptors. General For the purpose of this standard, the following terms shall have the meaning indicated in this section.

Technical and Dimensional Data. Saf-T Vent SC Plus

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

University of Delaware

W Limestone Chips, 50 lb. bag 31.80

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Domestic Pump Condensate Transfer Equipment

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

Packaged Semi-Instantaneous Steam Fired Water Heater

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

Semi-Instantaneous Indirect Fired Water Heater

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

SSV Mixers. The clear leader for cleanability, versatility and performance.

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

Flow Control for Fire Protection

SECTION PLUMBING SPECIALTIES

University of Rochester October 17, 2008 Brooks Landing Business Center

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Are you a Full Service Restaurant? 900XP & 700XP

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

ROVAL COLLECTION PAPER TOWEL DISPENSERS TOILET TISSUE DISPENSERS MIRRORS AUTOMATIC HAND DRYERS

Building Utilities 1 Plumbing and Sanitary Systems

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Special Requirements For Health Care Facilities

FT1000S BASE FLIGHT-TYPE DISHWASHER

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

A. This Section includes the following domestic water piping specialties:

ADA Compliant Wall-Mount Fountain and Bottle Filler

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Are you a Quick Service Restaurant? 900XP & 700XP

SECTION DUCTWORK

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

A. Codes and Standards that are Standard at the University:

Hoshizaki America, Inc.

Test Code: 8117 / Version 1

Transcription:

SMITH STINLESS FLOOR DRIN SERIES - CST 7 Round General Purpose Floor Drain with djustable Strainer Head for Light Duty Use Function: General service floor drain for use in finished areas where foot traffic is expected, and where a corrosion resistant drain is required. 7 (180) DI 4 (100) 3 (76) Figure No. 9700 REGULRLY FURNISHED CF8 (Equivalent to Type 304) Rough Finish Stainless Steel Body and Round djustable Strainer Head with Satin Finished Top. Fig. 9700C.... CULK OUTLET Fig. 9700T.... THREDED OUTLET 8 1 / 2 Round General Purpose Floor Drain for Medium Duty Use Figure No. 9710 REGULRLY FURNISHED CF8 (Equivalent to Type 304) Rough Finish Stainless Steel Body and Loose Set Non-Tilt Grate. NOTE paren Function: Used in floors where corrosive liquids must drain or be discharged. Solid top variation with closure plug allows placement of drains for future use. The advantage of stainless steel over high silicon iron is that it resists corrosive liquids and accomodates machining for threaded outlets, secured top and/or flashing clamps. These drains are readily adaptable to most types of drain line piping materials. Type 304 stainless steel will handle a variety of corrosive wastes which are found in laboratories, chemical, atomic energy, photographic processing, dairy, breweries and bottling. Loose Set Non-Tilt Grate 1 1/2(38) (132) SQ CM 11 (280) DI 8 1/2 (215) DI * 4(100) (Pipe Size) = 02(50), 03(75), or 04(100) Fig. 9710C.... CULK OUTLET Fig. 9710T.... THREDED OUTLET Free rea 20.50 SQ IN (132) SQ CM VRITIONS: 4 (100) or 6" (150) Dia. Funnel (Specify Fig. 9703) 8 3/4 (220) x 3 3/4" (95) Funnel (Specify Fig. 9704) Closure Plug and Gasket vailable in Stainless Steel -XPSS or Plastic -XPP Closure Plug with 3/4"(19) Test Plug -TP Flat Bottom Strainer -FBS Sediment Bucket -B Solid Scoriated Cover -SC Vandal Proof Grate -U OPTIONL MTERILS: -27 Carbon Steel -27 Cast Iron Grate -CIG Nickel Bronze Grate -NB Polished Bronze Grate -PB 9 Jay R. Smith Mfg. Co. Copyright 2007 ll Rights Reserved

SMITH STINLESS FLOOR DRIN SERIES - CST 8 1 / 2 Round Special Purpose Floor Drain with Solid Scoriated Cover and Closure Plug for Medium Duty Use Function: Used in floors and areas where a solid cover is required. Closure plug prevents sewer gases from entering the building through the drain. Type 304 stainless steel will handle a variety of corrosive wastes which are found in laboratories, chemical, atomic energy, photographic processing, dairy, breweries and bottling. Figure No. 9720 REGULRLY FURNISHED CF8 (Equivalent to Type 304) Rough Finish Stainless Steel Body, Secured Scoriated Cover and Stainless Steel Closure Plug with Gasket. 8 1 / 2 Round General Purpose Floor Drain with djustable Top for Medium Duty Use Function: Used in moderate traffic areas where an adjustable top permits accurate positioning of grate to meet finished floor levels. Type 304 stainless steel will handle a variety of corrosive wastes which are found in laboratories, chemical, atomic energy, photographic processing, dairy, breweries and bottling. Figure No. 9725 REGULRLY FURNISHED CF8 (Equivalent to Type 304) Rough Finish Stainless Steel Body, Loose Set Non-Tilt Grate with djustable Top. VRITIONS: 4 (100) or 6"(150) Dia. Funnel (Specify Fig. 9703) 8 3/4 (220) x 3 3/4" (95) Funnel (Specify Fig. 9704) Closure Plug and Gasket vailable in Stainless Steel -XPSS or Plastic -XPP Closure Plug with 3/4" (19) Test Plug -TP Jay R. Smith Mfg. Co. Copyright 2007 ll Rights Reserved Secured Scoriated Cover 1 1/2(38) 4(100) VRITIONS: Plastic Closure Plug and Gasket -XPP Closure Plug with 3/4" (19) Test Plug -TP Vandal Proof -U 90 Side Outlet (Specify Fig. 9759) Free rea 20.50 SQ IN (132) SQ CM 1 5/8 (41) MIN 3 5/8 (92) MX 11 (280) DI 8 1/2 (215) DI Stainless Steel Closure Plug with Gasket (Pipe Size) = 02(50), 03(75) or 04(100) 11 DI (230) 8 1/2 DI (215) 5 1/4 (135) 4 1/4 (110) (Pipe Size) 02(50), 03(75) or 04(100) Fig. 9725C..... CULK OUTLET Flat Bottom Strainer -FBS Sediment Bucket -B Solid Scoriated Cover -SC Vandal Proof Grate -U 90 Side Outlet (Specify Fig. 9759) 10 Fig. 9720C.... CULK OUTLET Fig. 9720T.... THREDED OUTLET OPTIONL MTERILS: -27 Carbon Steel -27 Loose Set Non-Tilt Grate djustable To p Seepage Openings Fig. 9725T..... THREDED OUTLET OPTIONL MTERILS: -27 Carbon Steel -27 Cast Iron Grate -CIG CF8M (Equivalent with Type 316) Nickel Bronze Grate -NB Polished Bronze Grate -PB

SMITH STINLESS FLOOR DRIN SERIES - CST 12 Round Shallow Body Floor Drain for Heavy Duty Use Figure No. 9730 REGULRLY FURNISHED CF8 (Equivalent to Type 304) Rough Finish Stainless Steel Body and Loose Set Non-Tilt Grate. Function: Used in areas where waste water contains no sediment or debris and construction requires a shallow body. Type 304 stainless steel will handle a variety of corrosive wastes which are found in laboratories, chemical, atomic energy, photographic processing, dairy, breweries and bottling. Free rea 27.63 SQ IN (178) SQ CM 16 (405) DI 12 (305) DI (Pipe Size) = 04(100) or 06(150) VRITIONS: 4 (100) or 6" (150) Dia. Funnel (Specify Fig. 9703) 8 3/4 (220) x 3 3/4" (95) Funnel (Specify Fig. 9704) Closure Plug and Gasket vailable in Stainless Steel -XPSS or Plastic -XPP Closure Plug with 3/4" (19) Test Plug Vandal Proof Grate -U 90 Side Outlet (Specify Fig. 9759) Loose Set Non-Tilt Grate 1 1/2 (38) 4 1/2 (115) Fig. 9730C... CULK OUTLET Fig. 9730T....THREDED OUTLET OPTIONL MTERILS: -27 Carbon Steel -27 Cast Iron Grate -CIG Nickel Bronze Grate -NB Polished Bronze Grate -PB 8 1 / 2 Round Special Purpose Floor Drain with djustable Top, Solid Scoriated Cover and Closure Plug for Medium Duty Use Figure No. 9735 Function: Used in floors where a solid cover and internal gasketed closure plug are required. Internal plug prevents sewer gas from escaping into building. djustable top collar permits accurate position of top cover to meet finished floor. 1 5/8 (41) MIN 3 5/8 (92) MX 5 1/4 (135) 11 DI (280) 8 1/2 DI (215) Secured Scoriated Cover djustable Top Seepage Openings 4 1/4 (110) Stainless Steel Closure Plug with Gasket (Pipe Size) = 02(50), 03(75) or 04(100) Fig. 9735C.... CULK OUTLET Fig. 9735T..... THREDED OUTLET REGULRLY FURNISHED CF8 (Equivalent to Type 304) Rough Finish Stainless Steel Body, djustable Top, Secured Scoriated Cover and Gasketed Stainless Steel Closure Plug. VRITIONS: Plastic Closure Plug and Gasket -XPP Closure Plug with 3/4" (19) Test Plug -TP Vandal Proof Cover -U 90 Side Outlet (Specify Fig 9759) OPTIONL MTERILS: -27 Carbon Steel -27 11 Jay R. Smith Mfg. Co. Copyright 2007 ll Rights Reserved

SMITH STINLESS FLOOR SINK SERIES - FBRICTED 12 Square Floor, rea & Indirect Waste Drain with Dome Bottom Strainer or Sediment Bucket Figure No. 9691-9699 REGULRLY FURNISHED 14 Gauge Type 304 SS Receptor Body with Seepage Control Holes, Cast Type 316 SS Ribbed Non-Tilt Loose Set Grate with 1/2 (13) Square Holes. Perforated SS Dome Bottom Strainer or Sediment Bucket as Indicated by Figure Number. Function: Used in nuclear and fossil fuel power stations, chemical plants, laboratories and other areas where the corrosion resistance of type 304 stainless steel is satisfactory for the intended service. lso used in other locations such as breweries, dairies, creameries and similar processing plants where superior corrosion resistance, durability and longevity are required. Excellent for use in restaurants, schools and all types of food handling areas for ultimate sanitation. Grates w/1/2 (13) holes - Free rea 34 SQ IN (219) SQ CM Optional grates w/1/4 (6) holes - Free rea 18 SQ IN (116) SQ CM 12 (305) SQ 10 1/2 (265) SQ B 2 (51) Optional DBS Sediment Bucket Model Shown (Pipe Size) = 02(50), 03(75) or 04(100) NO-HUB OUTLET Regularly Furnished FETURES, OPTIONS ND ORDERING INFORMTION VRITIONS: Dome Bottom Strainer -DBS (Bucket Models only) * -C Less Seepage Control Holes -LSH Solid Ported Bucket -SBP *with nchor Flange -F Trap Primer Connection -P050 1/2" (13) & -P075 3/4" (19) T Male Threaded Connection Suffix Description -10.....less SS Grate -12.....with SS 1/2 Grate -13.....with SS 3/4 Grate -14.....with SS 2 1/2 (64) Sq. Center Hole Grate -15.....with SS Recessed Grate with Handle -21.....with SS Grate with 4" (100) Dia. SS Funnel -22.....with SS Grate with 6" (150) Dia. SS Funnel -25.....with SS Grate with 8 1/4 (210) x 3 1/4 (53) x 4 1/2" (115) High Oval SS Funnel -26.....with SS Grate with 6 (150) x 2 1/2 (64) x 1" (25) High Oval SS Funnel -41.....with SS Solid Cover -42.....with SS 1/2 Solid Cover -43.....with SS 3/4 Solid Cover -44.....with SS 2 1/2" (64) Sq. Center Hole Solid Cover BUCKET MODELS ONLY: with SS Solid Bottom Ported Bucket -SBP with SS Dome Bottom Strainer -DBS OPTIONL MTERILS: Fabricated from Type 316 NOTE: When determining location of this drain, consideration must b loading factors. When used in areas where the drain is subje loading heavier than pedestrian foot traffic the location load OPTIONL TOP GRTES ND COVERS w/dome Strainer 9691 9692 9693 9694 FIGURE NUMBERS "B" Dim. 4 (100) 6 (150) 8 (205) 10 (255) w/sediment Bucket 9696 9697 9698 9699 Suffix Description -61.....with SS Heel-Proof Ribbed Non-Tilt Loose Set Grate with 1/4" (6) Sq. Holes -63.....with SS Medium Duty Heel-Proof Ribbed Non-Tilt Loose Set Grate with 1/4" (6) Sq. Holes -64.....with SS Heavy Duty Ribbed Non-Tilt Loose Set Grate with 1/2" (13) Sq. Holes -66.....with SS Extra Heavy Duty Ribbed Non-Tilt Loose Set Grate with 1/2" (13) Sq. Holes -69.....with 1" (25) Thick Underbolted NB Rim and Extra Heavy Duty Cast Stainless Steel Secured Grate (Flange Regularly Furnished 2" (51) from top will become 3" (76) from top) NOTE: When determining location of this drain, consideration must be given to traffic loading factors. When used in areas where the drain is subjected to any traffic loading heavier than *Flange pedestrian is located foot traffic, 2" (51) the from location, top load of drain. and description 3" (76) when specified. of load shall be submitted to Jay R. Smith's Sales Engineering Department for NOTE: Dimensions shown in parentheses are in millimeters. evaluation and selection of proper grate. Jay R. Smith Mfg. Co. Copyright 2007 ll Rights Reserved 12 *Flange is located 2" (51) from top of drain. 3" (76) when specified. NOTE: Dimensions shown in parentheses are in millimeters.

SMITH STINLESS CLENOUT SERIES - CST Round Deck Plug Type Floor Cleanout for Medium Duty Use Function: Used as floor cleanout for drainage lines. Cover is water and gas tight and requires a spanner wrench for removal. Type 304 stainless steel will handle a variety of corrosive wastes which are found in laboratories, chemical, atomic energy, photographic processing, dairy, breweries and bottling. B DI Spanner Wrench Type Cover Gasket C Figure No. 9760 (Pipe Size) = 02(50), 03(75) or 04(100) Fig. 9760C.... CULK OUTLET Fig. 9760T.... THREDED OUTLET REGULRLY FURNISHED CF8 (Equivalent to Type 304) Rough Finish Stainless Steel Body and Cover with Gasket. VRITIONS: Steel Spanner Wrench -SW BW (Specify Schedule -S05, -S10, or -S40) OPTIONL MTERILS: -27 Carbon Steel -27 Nickel Bronze Cover -NB SIZE 02(50) 03(75) CULK 4 1/2(115) 5 1/2(140) 04(100) 7 1/2(190) B DI BUTT WELD 4 1/2(115) 4 1/2(115) 5 1/2(140) C CULK 3 1/4(83) BUTT WELD 3 1/4(83) 13 Jay R. Smith Mfg. Co. Copyright 2007 ll Rights Reserved

SMITH STINLESS PRODUCT LINE SPECIFICTIONS FLOOR DRINS STINLESS STEEL 9700 FLOOR DRIN -GENERL PURPOSE DJUSTBLE TOP LIGHT DUTY Furnish and install a Jay R. Smith fi gure no. 9700 general purpose adjustable fl oor drain for use in fi nished areas where foot and/or light wheel traffi c is expected and a corrosion resistant drain is required. stainless steel body, secured scoriated cover and stainless steel closure plug with gasket. Options: 1) with (-C) 2) Satin Finish Top (-SF) 3) Vandal Proof Top (-U) 4) CF8M (Type 316) Stainless Steel (-316) stainless steel body and adjustable 7 round strainer head with satin fi nish. Options: 1) Sediment Bucket (-B) 2) 1/2 Trap Primer Connection (-P050) 3) Vandal Proof Top (-U) 4) with (-C) 5) 4 or 6 Dia. Funnel (Specify Fig. 9703) 9725 FLOOR DRIN - GENERL PURPOSE DJUSTBLE TOP MEDIUM DUTY Furnish and install a Jay R. Smith fi gure no. 9725 general purpose adjustable 8 1/2 round top fl oor drain for use in fi nished or unfi nished areas where moderate traffi c is expected and a corrosion resistant drain is required. stainless steel body, adjustable extension and loose set non-tilt slotted grate. 9710 FLOOR DRIN GENERL PURPOSE MEDIUM DUTY Furnish and install a Jay R. Smith fi gure no. 9710 general purpose 8 1/2 round top fl oor drain for use in fi nished or unfi nished areas where moderate traffi c is expected and a corrosion resistant drain is required. Options: 1) Sediment Bucket (-B) 2) with (-C) 3) Flat Bottom Strainer (-FBS) 4) Satin Finish Top (-SF) 5) Vandal Proof Top (-U) stainless steel body and loose set non-tilt slotted grate. Options: 1) Sediment Bucket (-B) 2) with (-C) 3) Flat Bottom Strainer (-FBS) 4) Satin Finish Top (-SF) 5) Vandal Proof Top (-U) 9730 FLOOR DRIN GENERL PURPOSE HEVY DUTY Furnish and install a Jay R. Smith fi gure no. 9730 general purpose 12 round top fl oor drain for use in fi nished or unfi nished areas where heavy traffi c is expected and a corrosion resistant drain is required. stainless steel body and loose set non-tilt slotted grate. 9720 FLOOR DRIN SPECIL PURPOSE MEDIUM DUTY Furnish and install a Jay R. Smith fi gure no. 9720 special purpose 8 1/2 round top fl oor drain for use in fl oors and areas where infrequent drainage is expected requiring a solid cover and closure plug to prevent sewer gas from entering the building. 18 Options: 1) Sediment Bucket (-B) 2) with (-C) 3) Flat Bottom Strainer (-FBS) 4) Satin Finish Top (-SF) 5) Vandal Proof Top (-U) Jay R. Smith Mfg. Co. Copyright 2007 ll Rights Reserved

FLOOR CLENOUTS STINLESS STEEL 9735 FLOOR DRIN SPECIL PURPOSE DJUSTBLE TOP MEDIUM DUTY Furnish and install a Jay R. Smith fi gure no. 9735 special purpose adjustable 8 1/2 round top fl oor drain for use in fl oors and areas where infrequent drainage is expected requiring a solid cover and closure plug to prevent sewer gas from entering the building. The drain shall be furnished with a cast CF8 (type 304) rough fi nish stainless steel body, adjustable extension, secured scoriated cover and stainless steel closure plug with gasket. Options: 1) with (-C) 2) Satin Finish Top (-SF) 3) Vandal Proof Top (-U) 4) CF8M (type 316) Stainless Steel (-316) 9760 DECK PLUG FLOOR CLENOUT MEDIUM DUTY Furnish and install a Jay R. Smith fi gure no. 9760 deck plug fl oor cleanout for use in fl oors where a gas tight spanner type cover is desired and a corrosion resistant cleanout is required. The cleanout shall be furnished with a cast CF8 (type 304) rough fi nish stainless steel body and spanner cover with gasket. Options: 1) Steel Spanner Wrench (-SW) 2) Type 316 Stainless Steel (-316) TRENCH DRIN STINLESS STEEL FLOOR SINKS STINLESS STEEL 9691-9699 INDIRECT WSTE RECEPTOR Furnish and install a Jay R. Smith fi gure no. 9691 (-12) series 12 square indirect waste receptor with half grate for use in areas where waste effl uent is discharged indirectly and a sanitary and corrosion resistant drain is required. The drain shall be furnished with a fabricated 14 gauge type 304 stainless steel body, cast type 316 loose set half grate with 1/2 square holes and satin fi nish and perforated dome bottom strainer. Options: 1) 3/4 Grate (-13) 2) nchor Flange (-F) 3) (-C) 4) 1/2 Trap Primer Connection (-P050) 5) Type 316 Stainless Steel (-316) 9660 TRENCH DRIN MODULR SYSTEM Furnish and install a Jay R. Smith fi gure no. 9660 trench drain system for use in fi nished and unfi nished areas where a corrosion resistant trench drain is required. The trench drain channels shall be 39.38 long, 6.38 wide, and have a 4 wide throat with bolting end plates. 23 modular channel sections shall be made of 16-gauge type 304 stainless steel. Channels shall be provided either neutral (fl at) or with a.6% pre-slope. Channels shall be available with inverts ranging from 3.75 to 7.50. Regularly furnished with secured light duty 9870-450-SS slotted stainless steel grate and 4 no-hub vertical outlet on channel sections 2, 5, 10, 15. End outlet plates are available in 2, 3 and 4 no-hub on channel sections 2, 5, 10, and 15. See table, page 15, for channel selection. Trench drain shall be Jay R. Smith Mfg. Co. fi gure number 9660 series. Options: 1) Buttweld Outlet (-BW) 2) Dome Bottom Strainer (-DBS) 3) 2, 3, 4 End Outlet 4) 4 Center Bottom Outlet (10N Only) 5) CF&M (type 316) Stainless Steel (-316SS) 6) See Page 16 for Grate Selection 19 Jay R. Smith Mfg. Co. Copyright 2007 ll Rights Reserved