Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

Similar documents
FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

Extinguishers. Commercial Industrial High rise buildings

Foam Wheeled Extinguisher AB Movable fire extinguishers

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

A full range of UK manufactured portable and wheeled fire extinguishers

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

PRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E

OUT CARBON DIOXIDE (CO2) EXTINGUISHER Certified & Approved to AS/NZS Lightweight Aluminium Cylinder. AS High pressure hose assembly with

PRODUCT MANUAL FIRE EXTINGUISHER. Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard)

FIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris,

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Technical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS

Portable & Mobile Fire Extinguishers MARINE EQUIPMENT DIRECTIVE (MED - WHEELMARK) 2017 EDITION 1

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

What are the four things that must be present at the same time to produce fire?

IGS-M-SF-01(0) IGS. Iranian Gas Standards. CO2 Fire Extinguisher, Portable Type

Salt Lake Community College FIRE EXTINGUISHER TRAINING

Dräger X-am 5000 Multi-Gas Detection

P50 Composite Extinguisher The New Generation. Britannia Fire Proudly manufacturing in Great Britain since 2010 SECURITY.

NUCLEAR POWER CORPORATION OF INDIA LIMITED (A Government of India Enterprise)

Cold water compact class Xpert HD 7125 *AU. Standard accessories: High-pressure hose 10 m Spray lance 380 mm Anti-twist system Pressure cut-off

Fire Extinguisher Training

Risk Management Department. Fire Extinguishers

Cold water compact class HD 5/15 C

Cold water compact class HD 5/11 C. Standard accessories: Trigger gun Extended highpressure. Technical data

Institute for Plasma Research Welcomes you all on

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

COMPONENT MAINTENANCE MANUAL

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

Product Data Sheet SINGAS F-Exx 8.o C. Status: 03. June 2015 Page 1 von 8 The Fire Extinguisher

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

Fire Extinguisher Training

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

P3HAFEX. System Description

Cold water compact class HD 6/15 C

RULES FOR STATUTORY SURVEY OF SEA-GOING SHIPS. FIRE-FIGHTING EQUIPMENT AND ESCAPE EQUIPMENT 2017 January

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

INDEX FIXED FIRE FIGHTING SYSTEM. 1. High Pressure Co2 System. 2. Local Water Mist System. 3. Deck Foam System. 4. Dry Chemical Powder System

Attachment 1. to ClassNK Technical Information No.TEC-0764 Malta Maritime Authority Date Revised 28 August 2008 Page 1 of 10 This Administration Requi

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006

Cold water compact class HD 6/13 C + Standard accessories: Trigger gun Extended easypress. Technical data

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Purple K B:C Potassium Bicarbonate Extinguishers

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

Guidance on the construction of CO 2 systems

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

Tel Web: dyayan.com

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

June 2018 Safety Meeting Fire Extinguishers Part I

Operating Instructions

Tender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE

Hot water super class HDS 12/18 4S *AU

VAPORETTINO LUX A B C E. Fig.1 Fig.2 Fig.3 Fig.4. Fig.5 Fig.6 Fig.7 Fig.8. Fig.9 Fig.10 Fig.11. Vaporettino Lux 1R02

Cold water compact class HD 5/17 C Plus

FIRE EXTINGUISHER SERVICING & MAINTENANCE INSTRUCTIONS

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Fire fighting Portable fire extinguishers Performance and construction

Cold water compact class HD 5/17 C

Portable Fire Extinguishers

PRODUCT MANUAL FIRE EXTINGUISHER

Twin-Agent Fire Fighting/Securing Systems Specifications

Cold water compact class HD 5/12 C

Technical Specification For Design and supply of Water Mist cum CAFS (Compressed Air Foam System) Backpack Fire Fighting System

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

Cold water HD 9/18-4 ST

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

Cold water compact class HD 6/15 CX Plus

HALOTRON I CLEAN AGENT FOR A, B & C FIRES REGULAR B:C FIRE EXTINGUISHERS PURPLE K B:C POTASSIUM BICARBONATE EXTINGUISHERS

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

Cold water compact class HD 6/13 C Plus *EU

Ceasefire Automobile Firefighters

With combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data

PROFESSIONAL SUPPLIER

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Model Policy On Portable Fire Extinguishers (Ontario Version)

Integrated Fire Protection Private Limited

SERVICE MANUAL WASHING. Washer-dryers HEC-RIM HEC-ARCHED. Structural characteristics, electrical components, accessibility

Dräger X-am 2500 Multi-Gas Detection

HIGH PERFORMANCE HEAVY DUTY INDUSTRIAL STORED PRESSURE

HOT WATER HIGH PRESSURE WASHER ON TRAILER COLORADO 350 (Mounted in a Waterkracht double-axe-trailer)

THÔNG BÁO KỸ THUẬT TÀU BIỂN TECHNICAL INFORMATION ON SEA-GOING SHIPS

Cold water compact class HD 5/12 C

Cold water middle class HD 6/16-4 M Plus

Model: 3508H 3508L 3508M. Part List US-English

COMPONENT MAINTENANCE MANUAL

I mpac t S a fet y S olut ions Your Key To Safety. Products Catalogue

Reflex fire detection and extinguishing system charged with Novec 1230 extinguishing agent. Installation, operation and maintenance instructions

September Safety Subject

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING. Factory No.: HYFP Style No.: WARNING WARNING READ BEFORE USE!

Fire Control Fire Extinguisher (FC5)

MOD. i300 i500. Pagina 1/1. All our products are in accordance with CEE rules: 89/392/CEE 91/368/CEE 93/44/CEE 93/68/CEE 73/23

Transcription:

1370 14133 14133 Powder Wheeled Fire Extinguisher kg 25 Approved EN 166-1:200, Marina MED, higest rate achieved - A IVB C CSI Certificate MED/0497/126/09 Organic solid materials, wood rubber, textiles etc. Flammable liquids, gasoline, oil etc. Flammable gases, methane, prophane. According directive 96/9/EC, EN 166 and with CE-mark The wheeled fire extinguisher is manufactured according to Directive 96/9/EC (MED) with modules B and D. As with portable extinguishers, wheeled units also have to comply with high standards to ensure their extinguishing capability (fire rating), quality and reliability. We at a.b.s. know how important it is to make the right choice in fire fighting. Recently, a new European standard for wheeled extinguishers, EN 166, was introduced. The a.b.s. wheeled extinguisher range, has been the first in Europe to comply with this standard. The wheeled units also carry the CE mark so the range can boast three quality guarantees :a.b.s. (ISO 9001), compliance with EN 166 and the CE mark. The standard EN166 defines important minimum levels of pressure retention, corrosion protection, operating temperatures and fire rating. Technical Characteristics Wheeled extinguisher is designed for professional use under severe circumstances, resulting in a high level of quality and ease of use. The cylinder, CE marked, it has the welded frame or detachable frame. Ease of mobility is achieved as a result of the large wheels with solid rubber tyres and push bar also ensuring good stability during operation. 2" Lever valve The valve is made in brass (STCW617N) and it passed all the requirements of the directive 97/23/EC. There is a safety device at 22 bar. There is a green safety seal to improve the optical check from far. Only a simple glance is enough to check if the extinguisher has been tampered. Pressure gauge Pressure gauge is brass, the thread is M10x1 with o-ring for easy unscrew to check the real internal pressure any time without need of tools. If the indicator is in the green field, the extinguisher is ready to be used. If the indicator is in the red field, call immediately the authorized service staff. Discharge device Equipped with a highly flexible hose made in EPDM rubber with an excellent resistance manufactured from selected synthetic materials complete with a pistol. The specially designed ergonomic patented pistol ensures a steady flow of powder with a very low drop in pressure. Extinguishing agent Dry chemical powder German is produced according to EN 615 and ISO 9000 quality control. The basic components of dry powder are ammonium phosphate and ammonium sulphate with special silicone additives enabling easy discharge and avoiding any caking process. Dry powder is non-corrosive, non-abrasive, and is non toxic for humans and animals. Advantages. Very mobile and easy to operate Excellent quality, therefore a long operational lifetime Good ergonomy, easy to drive Extremely high ratings on A, B and C class fires (solid combustibles, liquid fuels and gases) Can be used at low temperatures (-30 C) Easy to service First in Europe in accordance with the new EN 166 standards With CE approval Other dry powder types available (BC, Monnex) - Test method and result - The 233B tray has been used and four 21B trays have been installed alongside, as from the following design. Permanent stored pressure 233 B Ø 3 mt ON REQUEST Discharge pistol with 3/ swivel coupling. Cod. 21035_1 It allows easy unroling of the hose avoiding twisting The propellant used has been heptane. Two fire tests have been performed, with extincion time of respectively 9 and 10 seconds; the test result was positive. Classification obtained: - EN 166-233 IV B - the highest. Fire Extinguisher 14133 26/09/11 RB 1/AS 1/2

1370 14133 Technical specifications Cylinder "Ø"...: 245 mm +0-15 mm Material...: DD12 UNI EN 10111 Operating pressure...: 14 bar at 20 C Test pressure according 97/23/EC...: 30 bar Burst pressure...: >55 bar Temperature range...: -30 C +60 C Extinguishing agent... : Powder MAP ABC 30 Propellant...: nytrogen or dry air Nominal charge... : 25 Kg Discharge time ~...: 25 sec Jet lenght ~...: 11 m Dimensions Height ~...: 1020 mm Width ~... : 430 mm Depth ~... : 535 mm Weight ~... : 55 kg Complete replacement spare parts 31302_3 Including: Powder ABC, O-ring 2, washer rings, safety seal. The SOLAS Convention Chapter II-2 part C lays the obligation of the provision of replacement spare change for the 100% for the first 10 extinguishers installed, while the remaining fire extinguishers are needed the 50% of the replacement spare. The maximum quantity of refills shown are 60. 12 4 6 2 Spare part list Pos. Description Code Q.ty 1 Cylinder (33 lt) on request Stainless steel 27702 1 2 Lever valve brass 2120 1 3 Siphon tube PVC 21711 1 5 7 1 5 11 4 Manometer M10x1 Ø 27 mm brass 21521 1 5 Discharge pistol 21035 1 6 Safety device (in 3 pieces) 2103 1 7 Discharge hose L 5 mt 20640 1 On request hose L 10 mt 20640_1 Wheel Ø 300 mm 21931 2 9 Powder ABC MAP 30% 31230 25 10 Washer ring fibre 3/4 Ø 24x15,2x2 20021 1 11 O-ring Ø 2,62x13,1x1,34 21055 1 9 3 12 Safety pin 2109 1 Detachable frame No welding on the cylinder ensure better and higher safety. Welded frame. The axe and carring handle are welded on the cylinder body. The family 14133 include more than one type of version. 14133_1 - Detachable frame In accordance with the Directive 96/9/EC by the SOLAS 74 convention, resolutions and circulars of the IMO, EN 166-1:2007 on the Annex A.1/3.52 Directive 200/67/CE of the certificate and Notified by CSI SpA - No 0497. The use of non original spare parts may cause malfunctions loss Maintenance and Guarantee Maintenance must be made periodically by, trained and certified staff, according to the local regulations of the country where it is located. The extinguisher is guaranteed for 12 months from the date of the supply. The guarantee includes, repairing or replacement, as manufacturer option. Unit must be sent back to the factory free of charge, only when authorized written agreement with our sales office has been reached. The guarantee expires in case of tampering and bad maintenance made by not-authorized staff, or transport damages. It must be recharged only by staff authorized and certified by a.b.s. S.r.l., use only genuine original spare parts. Fire Extinguisher 14133 26/09/11 RB 1/AS 2/2

1370 14164 14164 Powder Wheeled Fire Extinguisher kg 50 Approved EN 166-1:200, Marina MED, higest rate achieved - A IVB C CSI Certificate MED/0497/129/09 Organic solid materials, wood rubber, textiles etc. Flammable liquids, gasoline, oil etc. Flammable gases, methane, prophane. According directive 96/9/EC, EN 166 and with CE-mark The wheeled fire extinguisher is manufactured according to Directive 96/9/EC (MED) with modules B and D. As with portable extinguishers, wheeled units also have to comply with high standards to ensure their extinguishing capability (fire rating), quality and reliability. We at a.b.s. know how important it is to make the right choice in fire fighting. Recently, a new European standard for wheeled extinguishers, EN 166, was introduced. The a.b.s. wheeled extinguisher range, has been the first in Europe to comply with this standard. The wheeled units also carry the CE mark so the range can boast three quality guarantees :a.b.s. (ISO 9001), compliance with EN 166 and the CE mark. The standard EN166 defines important minimum levels of pressure retention, corrosion protection, operating temperatures and fire rating. Technical Characteristics Wheeled extinguisher is designed for professional use under severe circumstances, resulting in a high level of quality and ease of use. The cylinder, CE marked, it has the welded frame or detachable frame. Ease of mobility is achieved as a result of the large wheels with solid rubber tyres and push bar also ensuring good stability during operation. 2" Lever valve The valve is made in brass (STCW617N) and it passed all the requirements of the directive 97/23/EC. There is a safety device at 22 bar. There is a green safety seal to improve the optical check from far. Only a simple glance is enough to check if the extinguisher has been tampered. Pressure gauge Pressure gauge is brass galvanized the thread is M10x1 with o-ring for easy unscrew to check the real internal pressure any time without need of tools. If the indicator is in the green field, the extinguisher is ready to be used. If the indicator is in the red field, call immediately the authorized service staff. Discharge device Equipped with a highly flexible hose made in EPDM rubber with an excellent resistance manufactured from selected synthetic materials complete with a pistol. The specially designed ergonomic patented pistol ensures a steady flow of powder with a very low drop in pressure. Extinguishing agent Dry chemical powder German is produced according to EN 615 and ISO 9000 quality control. The basic components of dry powder are ammonium phosphate and ammonium sulphate with special silicone additives enabling easy discharge and avoiding any caking process. Dry powder is non-corrosive, non-abrasive, and is non toxic for humans and animals. Advantages Very mobile and easy to operate Excellent quality, therefore a long operational lifetime Good ergonomy, easy to drive Extremely high ratings on A, B and C class fires (solid combustibles, liquid fuels and gases) Can be used at low temperatures (-30 C) Easy to service First in Europe in accordance with the new EN 166 standards With CE approval Other dry powder types available (BC, Monnex) - Test method and result - The 233B tray has been used and four 21B trays have been installed alongside, as from the following design. Permanent stored pressure 233 B Ø 3 mt Swivel coupling It allows easy unroling of the hose avoiding twisting ON REQUEST Cod. 2103_2 Horn in aluminium shock resistant. The propellant used has been heptane. Two fire tests have been performed, with extincion time of respectively 9 and 10 seconds; the test result was positive. Classification obtained: - EN 166-233 IV B - the highest. Fire Extinguisher 14164 26/09/11 RB 1/AS 1/2

1370 14164 Technical specifications Cylinder "Ø"...: 300 mm Material...: DD12 UNI EN 10111 Operating pressure...: 14 bar at 20 C Test pressure according 97/23/EC...: 30 bar Burst pressure...: >55 bar Temperature range...: -30 C +60 C Extinguishing agent... : Powder MAP ABC 30 Propellant... : nytrogen or dry air Complete replacement spare parts 31302_1 Including: Powder ABC, O-ring,washer rings, safety seal. Nominal charge... : 50 Kg Discharge time ~...: 43 sec Jet lenght ~...: 11 m Dimensions Height ~...: 1050 mm Width ~... : 450 mm Depth ~... : 550 mm Weight ~... : 0 kg The SOLAS Convention Chapter II-2 part C lays the obligation of the provision of replacement spare change for the 100% for the first 10 extinguishers installed, while the remaining fire extinguishers are needed the 50% of the replacement spare. The maximum quantity of refills shown are 60. 6 7 13 4 5 2 12 Spare part list Pos. Description Code Q.ty 1 Cylinder (54 lt) on request Stainless steel 2704 1 2 Lever valve brass 2120 1 3 Siphon tube PVC 21715 1 4 Manometer M10x1 Ø 27 mm brass 21521 1 1 5 Turning valve brass 3/4 66030 1 6 Discharge horn 2103 1 10 3 9 7 Safety device (in 3 pieces) 2103 1 Discharge hose L 5 mt 20649 1 On request hose L 10 mt 20649_1 9 Wheel Ø 300 mm 21931 2 10 Powder ABC MAP 30% 31230 50 11 Cap for protection foot cylinder 2072 2 12 Washer ring fibre 3/4-15,2x24x2 20021 1 11 13 Safety pin 2109 1 Detachable frame No welding on the cylinder ensure better and higher safety. Welded frame. The axe and carring handle are welded on the cylinder body. The family 14164 include more than one type of version. 14164_1 - Detachable frame In accordance with the Directive 96/9/EC by the SOLAS 74 convention, resolutions and circulars of the IMO, EN 166-1:2007 on the Annex A.1/3.52 Directive 200/67/CE of the certificate and Notified by CSI SpA - No 0497. The use of non original spare parts may cause malfunctions loss Maintenance and Guarantee Maintenance must be made periodically by, trained and certified staff, according to the local regulations of the country where it is located. The extinguisher is guaranteed for 12 months from the date of the supply. The guarantee includes, repairing or replacement, as manufacturer option. Unit must be sent back to the factory free of charge, only when authorized written agreement with our sales office has been reached. The guarantee expires in case of tampering and bad maintenance made by not-authorized staff, or transport damages. It must be recharged only by staff authorized and certified by a.b.s. S.r.l., use only genuine original spare parts. Fire Extinguisher 14164 26/09/11 RB 1/AS 2/2

1370 1411 1411 Powder Wheeled Fire Extinguisher kg 100 Approved EN 166-1:200, Marina MED, higest rate achieved - A IVB C CSI Certificate MED/0497/132/09 Organic solid materials, wood rubber, textiles etc. Flammable liquids, gasoline, oil etc. Flammable gases, methane, prophane. According directive 96/9/EC, EN 166 and with CE-mark The wheeled fire extinguisher is manufactured according to Directive 96/9/EC (MED) with modules B and D. As with portable extinguishers, wheeled units also have to comply with high standards to ensure their extinguishing capability (fire rating), quality and reliability. We at a.b.s. know how important it is to make the right choice in fire fighting. Recently, a new European standard for wheeled extinguishers, EN 166, was introduced. The a.b.s. wheeled extinguisher range, has been the first in Europe to comply with this standard. The wheeled units also carry the CE mark so the range can boast three quality guarantees :a.b.s. (ISO 9001), compliance with EN 166 and the CE mark. The standard EN166 defines important minimum levels of pressure retention, corrosion protection, operating temperatures and fire rating. Technical Characteristics Wheeled extinguisher is designed for professional use under severe circumstances, resulting in a high level of quality and ease of use. The cylinder, CE marked, it has the welded frame or detachable frame. Ease of mobility is achieved as a result of the large wheels with solid rubber tyres and push bar also ensuring good stability during operation. 2" Lever valve The valve is made in brass (STCW617N) and it passed all the requirements of the directive 97/23/EC. There is a safety device at 22 bar. There is a green safety seal to improve the optical check from far. Only a simple glance is enough to check if the extinguisher has been tampered. Pressure gauge Pressure gauge is brass galvanized the thread is M10x1 with o-ring for easy unscrew to check the real internal pressure any time without need of tools. If the indicator is in the green field, the extinguisher is ready to be used. If the indicator is in the red field, call immediately the authorized service staff. Discharge device Equipped with a highly flexible hose made in EPDM rubber with an excellent resistance manufactured from selected synthetic materials complete with a pistol. The specially designed ergonomic patented pistol ensures a steady flow of powder with a very low drop in pressure. Extinguishing agent Dry chemical powder German is produced according to EN 615 and ISO 9000 quality control. The basic components of dry powder are ammonium phosphate and ammonium sulphate with special silicone additives enabling easy discharge and avoiding any caking process. Dry powder is non-corrosive, non-abrasive, and is non toxic for humans and animals. Advantages Very mobile and easy to operate Excellent quality, therefore a long operational lifetime Good ergonomy, easy to drive Extremely high ratings on A, B and C class fires (solid combustibles, liquid fuels and gases) Can be used at low temperatures (-30 C) Easy to service First in Europe in accordance with the new EN 166 standards With CE approval Other dry powder types available (BC, Monnex) - Test method and result - The 233B tray has been used and four 21B trays have been installed alongside, as from the following design. Permanent stored pressure 233 B Ø 3 mt Swivel coupling It allows easy unroling of the hose avoiding twisting ON REQUEST Cod. 2103_2 Horn in aluminium shock resistant. The propellant used has been heptane. Two fire tests have been performed, with extincion time of respectively 9 and 10 seconds; the test result was positive. Classification obtained: - EN 166-233 IV B - the highest. Fire Extinguisher 1411 26/09/11 RB 1/AS 1/2

1370 1411 Technical specifications Cylinder "Ø"...: 360 mm Material...: DD12 UNI EN 10111 Operating pressure...: 14 bar at 20 C Test pressure according 97/23/EC...: 30 bar Burst pressure...: >55 bar Temperature range...: -30 C +60 C Extinguishing agent... : Powder MAP ABC 30 Propellant... : nytrogen or dry air Complete replacement spare parts 31302_6 Including: Powder ABC, O-ring, washer rings, safety seal. Nominal charge...: 100 Kg Discharge time ~...: 99 sec Jet lenght ~...: 12 m Dimensions Height ~...: 1290 mm Width ~... : 540 mm Depth ~... : 700 mm Weight ~...: 140 kg The SOLAS Convention Chapter II-2 part C lays the obligation of the provision of replacement spare change for the 100% for the first 10 extinguishers installed, while the remaining fire extinguishers are needed the 50% of the replacement spare. The maximum quantity of refills shown are 60. 6 7 13 4 5 2 12 Spare part list Pos. Description Code Q.ty 1 Cylinder (101 lt) on request Stainless steel 27002 1 2 Lever valve brass 2120 1 3 Siphon tube PVC 2170 1 4 Manometer M10x1 Ø 27 mm brass 21521 1 5 Turning valve brass 3/4 66030 1 1 6 Discharge horn 2103 1 10 3 7 Safety device (in 3 pieces) 2103 1 Discharge hose L 5 mt 20649 1 9 On request hose L 10 mt 20649_1 9 Wheel Ø 300 mm 21931 2 10 Powder ABC MAP 30% 31230 100 11 Cap for protection foot cylinder 2073 2 12 Washer ring fibre 3/4-15,2x24x2 20021 1 11 13 Safety pin 2109 1 Detachable frame No welding on the cylinder ensure better and higher safety. Welded frame. The axe and carring handle are welded on the cylinder body. The family 1411 include more than one type of version. 1411_1 - Detachable frame In accordance with the Directive 96/9/EC by the SOLAS 74 convention, resolutions and circulars of the IMO, EN 166-1:2007 on the Annex A.1/3.52 Directive 200/67/CE of the certificate and Notified by CSI SpA - No 0497. The use of non original spare parts may cause malfunctions loss Maintenance and Guarantee Maintenance must be made periodically by, trained and certified staff, according to the local regulations of the country where it is located. The extinguisher is guaranteed for 12 months from the date of the supply. The guarantee includes, repairing or replacement, as manufacturer option. Unit must be sent back to the factory free of charge, only when authorized written agreement with our sales office has been reached. The guarantee expires in case of tampering and bad maintenance made by not-authorized staff, or transport damages. It must be recharged only by staff authorized and certified by a.b.s. S.r.l., use only genuine original spare parts. Fire Extinguisher 1411 26/09/11 RB 1/AS 2/2