B-LINE SERIES. TOLCO Branch line restraints for fire protection systems. per NFPA 13 ( ) TOLCO seismic bracing branch line restraints FPSBLR

Similar documents
FIRE SPRINKLER SYSTEMS POLICY

FIRE SPRINKLER SYSTEMS POLICY

Hazardous Area Communications

Hazardous Area Communications

Standard Universal Sway Brace or Restraint Device Sway Brace Fitting

TRUST THE ORIGINAL. SUBMITTAL PACKAGE

FIRE SUPPRESSION SPRINKLER SYSTEM

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

CCTV quick connect Harsh and Hazardous area connectors for camera stations

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

Standard Procedure s for Tenant Fire Sprinkler Work

AF/GF dual-purpose receptacles

B-LINE SERIES. Product brochure. Firestop

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

DIVISION 21 - FIRE SUPPRESSION

SECTION GAS-FIRED RADIANT HEATERS

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

Chapter 8 ANCHORAGE OF HOME CONTENTS

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

CITY OF PASADENA FIRE DEPARTMENT

DIVISION 21 - FIRE SUPPRESSION

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

ADDITIONAL PRODUCTS 65

TRANSLUCENT FIRE RATED SYSTEMS

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

D. Reference Standards (Utilize latest editions available):

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Eaton brings you CCTV solutions from. world class product ranges,

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

E. Luminaire: Complete lighting fixture, including ballast housing if provided.

Available at: Last Modified: December 2012

Center for Life Safety Education

Design & Construction Standards, Revised January

Arrow Hart hospital grade self-test GFCI receptacles

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

SECTION DRY-PIPE SPRINKLER SYSTEMS

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

standard response dry horizontal sidewall sprinklers

Model DDX Deluge Valve

standard response dry horizontal sidewall sprinklers

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Setting the Standard in Third-party Certification

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

AXIOM L CANOPY Installation Guide

MTL1000 Series Signal Conditioners. For reliable, high quality process communications

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

Sprinkler Permit Applications

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

standard response elo upright sprinkler

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

MODEL V-BB SPECIFIC APPLICATION TECHNICAL DATA

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

SECTION AUTOMATIC SPRINKLER PIPING

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

FIRE PROTECTION DESIGN REQUIREMENTS FOR TENANTS (Revised 1/15/2019)

B. Related Sections: The following Sections contain requirements that relate to this Section.

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

Page PRODUCT DESCRIPTION

Guidelines for Earthquake Bracing of Residential Water Heaters

SECTION SPRINKLER SYSTEMS

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

SECTION ADDENDUM NO. 1 FIRE SPRINKLER SYSTEM

Linear Heat Detection Engineering Specifications

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Fire Performance of Translucent Systems

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

TECHNICAL DATA MODEL V-HIP SPECIFIC APPLICATION ATTIC SPRINKLER VK660

quick response Sprinkler 105a October 25, 2010

SECTION INSPECTION AND TESTING OF WORK

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

SECTION DRY-PIPE SPRINKLER SYSTEMS

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

Arrow Hart specification grade GFCI receptacles

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

Transcription:

TOLCO seismic bracing branch line restraints FPSBLR B-LINE SERIES TOLCO Branch line restraints for fire protection systems per NFPA 13 (2010-2013)

TOLCO Branch Line Restraints for Fire Protection Systems TOLCO Seismic Bracing for Branch Line Restraints Rely on us for all your seismic and engineering needs TOLCO Seismic Bracing products are manufactured in California, which is located on the Ring of Fire - locations that experience multiple earthquakes a year. Most are small, but some are significant and the potential for a major catastrophic earthquake is always present. Being located in a virtual living laboratory of seismic activity has driven our team of engineers to develop some of the best seismic bracing product designs in the industry. Our products are known and respected by installers, designers, and fire protection authorities worldwide. For over 45 years, TOLCO Seismic Bracing products have been installed around the world where earthquakes are prevalent. Our UL Listed and FM approved quality seismic bracing products are confidently relied upon to help protect lives and property, from these devastating forces. TOLCO Seismic Bracing products are specified worldwide for bracing fire sprinkler systems against damage from earthquakes. Installing our UL Listed and FM approved bracing products helps to ensure compliance with the National Fire Protection Association Standard for the installation of fire sprinkler systems (NFPA 13). This brochure is intended to show examples of how TOLCO Seismic Bracing can help you meet the NFPA 13 Guidelines for Branch Line Restraints. NFPA 13 GUIDELINES FOR BRANCH LINE RESTRAINTS* The National Fire Protection Association Pamphlet 13 (2010-2013) as part of a complete seismic bracing system, requires that sprinkler mains and cross mains be braced and that branch lines 2 inches and smaller be restrained. How branch lines are to be restrained is defined in Section 9.3.6.1; also see Annex Section A.9.3.6.1(5) and Annex Figures A.9.3.6.1(5)(a)&(b). NFPA 13 (2010-2013 in Section 9.3.6.1) for additional information. Per these guidelines, restraints are considered a lesser degree of resisting loads than bracing and shall be provided by use of one of the following*: 1. Listed Sway Brace 2. Wrap-around U-Hook satisfying the requirements of 9.3.5.5.11 3. No. 12, 440 lb. (200 kg) wire installed at least 45 degrees from the vertical plane and anchored on both sides of the pipe 4. CPVC hangers utilizing two points of attachment 5. Hanger not less than 45 degrees from vertical installed within 6 inches (152 mm) of the vertical hanger arranged for restraint against upward movement, provided it is utilized such that l/r does not exceed 400, where the rod shall extend to the pipe or have a surge clip installed 6. Other approved means It should be noted that devices that are listed by UL as seismic restraint devices, as tested and defined by UL 203A, only meet the criteria of option 6 noted above. As such it is appropriate for the area authority to require test results or structural calculations for the specific installation under review. * For the most up-to-date and full details on the NFPA guidelines, please refer to the NFPA website: www.nfpa.org

A Listed Sway Brace Device used as a Branch Line Restraint Satisfies Requirements of NFPA 13 2010 & 2013 Section 9.3.6.1(1) Sway Brace Assembly Example TOLCO Fig. 980 Universal Swivel Sway Brace Attachment TOLCO Fig. 1001 Sway Brace Attachment 1" Brace Pipe This option while providing some of the best resistance to horizontal loads should be considered carefully. Seismic brace components have published maximum loads and when submitted for review, should be accompanied with zone of influence (ZOI) calculations per NFPA 13; 10 & 13 Section 9.3.5.6 that take into consideration the orientation of the fastener and the brace angle so as not to exceed these loads. An area authority should request these calculations for branch line restraints as well to verify they have the capacity to restrain the required loads. It should be noted that devices that are listed by UL as seismic restraint devices, as tested and defined by UL 203A, only meet the criteria of option 6, other approved means, noted on previous page. As such it is appropriate for the area authority to require test results or structural calculations for the specific installation under review. Wrap-Around U-Hook Satisfies Requirements of NFPA 13 (2010; Section 9.3.6.1(2) other approved means ; Section 9.3.5.3.10) (2013; Section 9.3.5.5.11) This option is clearly defined and requires no additional calculations to prove its performance. Fig 120W Fig 120RWA No. 12, 440 lb. (200 kg) wire installed at least 45 degrees from the vertical plane and anchored on both sides of the pipe Satisfies Requirements of NFPA 13 2010 & 2013 Section 9.3.6.1(3) While this option can be more difficult to install, the process is clearly defined and details are provided by NFPA to make inspection by area authorities easier. No additional calculations are required. However, please note that two points of contact are required, which can increase the installation time and cost.

CPVC Hangers Utilizing Two Points of Attachment Satisfies Requirements of NFPA 13 2013 Section 9.3.6.1(4) Typical CPVC hangers utilize two #10 x 1" screws and attach the sprinkler pipe directly to the structure. Similar to the wrap-around u-hanger option this sufficiently restrains the pipe and requires no additional calculations. Please note to be careful when selecting this option as not all CPVC hangers are UL Listed as both hangers and restrainers. TOLCO CPVC Hanger Options Fig 22 Fig 23 Fig 24 Fig 28 Fig 28M Hanger not less than 45 degrees from vertical Fig 29 & Fig 22L2 not shown Installed within 6 inches (152 mm) of the vertical hanger arranged for restraint against upward movement, provided it is utilized such that l/r does not exceed 400, where the rod shall extend to the pipe or have a surge clip installed. Satisfies Requirements of NFPA 13 2010 & 2013 Section 9.3.6.1(5) see also NFPA 13 2013 Annex A.9.3.6.1(5) and Figures 9.3.6.1(5)(a)&(b) This option is clearly defined by NFPA 13 and if UL Listed hanger components are used then no additional calculations or test data is required for use. Use of all thread rod or machine threaded rod should comply with the requirements of NFPA 13 2010 Section 9.3.5.8.7(a,b&c) and NFPA 13 2013 Section 9.3.5.11.8(a,b&c) L/R should not exceed 400 If two opposing rod assemblies are installed at a location then the limitations of the table below regarding all thread rod length do not apply, subject to the approval of the area authority having jurisdiction Fig. 76 Allowable Rod Lengths per NFPA 13 (2010 & 2013) Rod Size (in) 3/8" 1/2" Area (sq. in).07.129 Least Radius of Gyration (in).075.101 L/R=100 0'-7" 0'-10" 1'-2" 1'-8" Other Approved Means L/R=200 L/R=300 1'-10" 2'-6" L/R=400 Satisfies Requirements of NFPA 13 2010 Section 9.3.6.1(5) and 2013 Section 9.3.6.1(6) This option gives the area authority latitude to approve other methods in the case where none of the other methods can be applied. Not defined at all, when used it would most likely require supporting structural calculations or test data. To help meet this option, TOLCO offers the services of our Seismic Engineering Department with a professional Structural Engineer on staff to supply wet-stamped structural calculations as required. 2'-6" 3'-4" Fig. 77 Other Approved Means Example TOLCO Fig. 76 Structural BLR Attachment, is designed to use both 3/8" and 1/2" rod, and multiple types of fasteners for various structure types. Fig. 77 System BLR Attachment is designed to use both 3/8" and 1/2" rod and easily snaps on to either side of plastic pipe.

Create a Complete Submittal Package with TOLBrace Software Designed for ease of use, the TOLBrace software steps the user through a series of questions to determine the scope of the project. It helps the user create detailed reports of the appropriate seismic bracing components and TIFF files for CAD use. It calculates the correct bracing loads per NFPA 13 guidelines, Uniform Building Code (UBC) and International Building Code (IBC). Also, to help ensure users are following the latest codes, standards, and product requirements, TOLBrace software also includes an automatic update feature. TOLBrace software assists fire sprinkler system designers in: Seismic force factor calculations (Fp) Zone of influence calculations Sway brace orientation and angle selection Structural attachment of sway braces Brace material selection Appropriate selection of UL Listed and FM approved sway brace components Creating a submittal sheet with all relevant information with the click of a mouse Selection of Branch Line Restraint details from NFPA 13 approved methods Available in English & Spanish TOLBrace follows the requirements of: NFPA 13, 1999, 2002, 2007, 2010 & 2013 Factory Mutual International Building Code (IBC) For additional support, contact your TOLCO Seismic Bracing Specialist at: Phone: 909-427-9773 Email:SeismicQuotes@Eaton.com Email:TolcoSupport@Eaton.com To learn more, visit www.cooperbline.com/fireprotection.

For more information, visit www.cooperbline.com/fireprotection. U.S. Customer Service Center is staffed Monday through Friday from 7 a.m. to 5 p.m. Central Standard Time. 509 West Monroe Street Highland, IL 62249 Phone: 800-851-7415 www.cooperbline.com/contactus 13201 Dahlia Street, Suite 200 Fontana, CA 92337 951-737-5599 www.cooperbline.com/contactus 5925 McLaughlin Road Mississauga, ON L5R 1B8 Canada Phone: 800-569-3660 www.cooperbline.com/contactca PO Box 70160 - Al Khobar - 31952 Kingdom of Saudi Arabia Phone: 00966 3 812 2236 www.cooperbline.com/contactme Eaton s Cooper Singapore No. 2 Serangoon North Ave. 5 #06-01 Fu Yu Building, 554911 Singapore Phone: +65 (0) 62974849 Eaton s Cooper Korea Co., Ltd. 13 Fl Vision Tower, 7072 Yeoksam-dong Gangnam-gu Seoul, 135-080 Korea Phone: +44 (0) 1278 772600 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com 2015 Eaton All Rights Reserved Printed in USA Publication No. SA312001EN August 2015 FPSBLR-15 B-Line Division 13201 Dahlia Street, Suite 200 Fontana, CA 92337 Phone: 800-851-7415 www.cooperbline.com/tolco Eaton is a registered trademark. All other trademarks are property of their respective owners.