Notification Appliance Circuit Module

Similar documents
Battery charger modules

DS7465i. Installation Instructions. Input/Output Module

D250A/D253/D261AW/D280A/D290 Series

F220-B6PS/M. Installation Guide. Addressable Detector Bases

Addressable NAC Output Module D327A

D7053. Installation Instructions Multiplex Input/Output Module

D7044. Installation Instructions Multiplex Single Input Module

D7052. Installation Instructions Multiplex Dual Input Module

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

FMR Installation Instructions. Addressable Fire System Controller

Booster Power Supply Manual

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Multiplex Eight Input Remote Modules

Remote NAC Power Supply D7038

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide

Duct smoke housing, 2-wire D340/D340P

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

FireNET Plus Wiring Instructions

Operation and Installation Guide. Zone Expansion Module D8125

D1255RB/D1256RB/D1257RB

Fire Control/Communicator

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide. Control/Communicator

Independent Zone Control (I.Z.C.)

Installation Guide for models:

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Control Panels B5512/B4512/B3512. en UL Installation Instructions

30.45 Electric Release PDRP-2001

D2071A. Operation & Installation Guide Fire Alarm Control Panel

AL800ULADA. NAC Power Extender. Installation Guide

D7024 Fire Alarm Control Panel

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

MO144. Operators Guide. Universal Timer Module

LifeAlarm Fire Alarm Controls

PSN-1000 & PSN 1000(E) Installation Manual

Installation Guide for models:

SIGA-CC1 Single Input Signal Module Installation Sheet

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

June 10, 2002 DF C S2424

Print Specification. Publication. Instructions. Specific requirements. General requirements

Model 17A00 Expansion Enclosure

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

These instructions detail procedures to follow in order to avoid damage to equipment.

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

D2412 Control / Communicator Installation Manual

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

E S L I N S T A L L A T I O N A N D O P E R A T I O N S M A N U A L ESL Fire Alarm Control Panel ESL

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MR-2602 Two Zone Fire Alarm Control Panel

Conventional Releasing Control Panel

4100U City and Relay Cards Installation Instructions

SENTROL ZX440F. Security System Control. Installation/ Programming

Fire Alarm Control Panels FPD-7024

Specification/ Data Sheet

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Multiple Input and Output Modules

Series. Access Power Controllers. Installation Guide

Model 4880 Status Output Display Module Manual

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

D720 and D1255 Command Centers

Operation and Installation Guide. Fire Alarm Control Panel

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Integrated Security Solutions

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

rvm4c Installation Guide Remote Video Module

Access Power Controllers with Power Supplies

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

/5121/5122 TrueAlert Power Supply Installation Instructions

RELEASE DEVICE CONTROLS

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

TECHNICAL DATA OBSOLETE

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

LifeAlarm Fire Alarm Control Panels

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

SILENT KNIGHT. Model SK-2/E & SK-4/E. Installation and Operations Manual. Fire Alarm Control Panel. Part Number Rev. A ECN /08/05

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Transcription:

Notification Appliance Circuit Module D192G en Installation guide

Notification Appliance Circuit Module Notices en 3 1 Notices These instructions cover the installation of the D192G Notification Appliance Circuit Module in a fire system supervised by a fire alarm control panel (FACP) or a combination Burglary/Fire control panel. Install, test and maintain the module according to these instructions, NFPA 72, local codes, and the authority having jurisdiction (AHJ). Failure to follow these instructions can result in failure of a detector to initiate an alarm event. Bosch Security Systems, Inc. is not responsible for improperly installed, tested or maintained devices. Before installing the module, become familiar with the Installation and Operation Guide for the control panel you are using. The module uses only polarized (DC) signaling devices. Not all signaling devices are polarized. The signaling devices used with the module must: be polarized (DC) signaling devices. match the voltage rating of the alarm power supply. not exceed the current rating of the alarm power supply. not exceed 3 A per module. total no more than 12 D192G modules per system.! Warning! Follow these instructions to avoid personal injury and damage to equipment. NFPA 72 requires that you perform a complete system wide functional test following any modifications, repair, upgrades or adjustments made to the system s components, hardware, wiring, programming and software/firmware. Bosch Security Sustems, Inc. Installation guide 2013.05 03 4.998.122.260

4 en Notices Notification Appliance Circuit Module 2 Description This module is used for wiring connections to remote signaling devices. Wiring is supervised for open, short, or grounded circuit faults. You can connect up to 12 D192G modules to the same system on the control panels listed in the table below. For the individual annunciation of an indicating bell circuit, connect the modules to separate points. The module powers notification appliances from the control panel power supply or from an Underwriters Laboratories, Inc. (UL 1481) Listed auxiliary 12 VDC or 24 VDC regulated/ power limited power supply for fire protective signaling units and commercial/residential burglar units. This feature allows the system to support more signaling devices on longer wire runs. It also allows the use of 12 V or 24 V notification appliances requiring the appropriate power supply. Control panels Compatible modules Compatible relays See section: Active Products: G-series (V2 and higher) 1 panels D8128D D130, D133, D134 Wiring the module with G Series control panels, page 8 B series panels 2 D133, D134 Wiring the module with B Series control panels, page 12 Legacy Products*: G 3 panels* D9124* See control panel documentation on Bosch website (http:// www.boschsecurity.com) 1 G-series (V2 and higher) = GV4 (D9412GV4, D7412GV4, and D7212GV4**), GV3 (D9412GV3, D7412GV3, and D7212G3**), and GV2 (D9412GV2, D7412GV2, and D7212GV2**) 2 B series = B5512**, B4512** and B3512** 3 G = D9412G, D7412G, D7212G** * Legacy products were investigated to comply only to UL864 8th edition ** indicates products which are not UL Listed for commercial fire applications. 2013.05 03 4.998.122.260 Installation guide Bosch Security Sustems, Inc.

Notification Appliance Circuit Module Notices en 5 Figure 2.1: D192G_NAC_Module 1 Power from the control panel s AUX POWER 2 Connection to control panel s COMMON circuit ground (see Warning below) 3 Connection to control panel zone output 4 Connection to control panel s programmable alarm outputs 5 Positive(+) connection to UL 1481 remote auxiliary power supply 6 Negative (-) connection from UL1481 remote auxiliary power supply 7 Positive (+) connection to the signaling device loop 8 Negative (-) connection to the signaling device loop 9 Toggle switch for silencing the indicating devices 10 Mounting holes! Warning! The D192G common (COM) terminals are digital ground, not earth ground. A ground fault condition exists when the COM terminals are connected to earth ground. Bosch Security Sustems, Inc. Installation guide 2013.05 03 4.998.122.260

6 en Notices Notification Appliance Circuit Module 3 Operation During normal operation, the NAC loop is supervised for opens, shorts, and ground faults. If any of these conditions is detected, the control panel indicates a trouble condition at the command center. Program the control panel to report the condition to the central station. (See Programming, page 17.) When the control panel detects an alarm, the alarm output circuit triggers the module to supply circuit power to the NAC devices. When testing the alarm panel, the module uses a toggle switch to silence the fire alarm indicating devices. When the toggle switch is in Silence Mode (off), the module indicates a supervisory trouble condition to the control panel and the yellow SUPERVISION TROUBLE LED lights. The following table indicates possible causes for the various LED indicator patterns: Indicator Possible cause SUPERVISION TROUBLE LED (yellow) is on. Output loop or 560 Ω EOL resistor is open or missing. Alarm switch is in SILENCE (OFF) position. SUPERVISION TROUBLE LED and ALARM LED (red) are off. ALARM LED is on. SUPERVISION TROUBLE and ALARM LEDs are on. Normal operation with no alarm or trouble. No power. Check for voltage across the External Power In and Common terminals. If the external voltage is not connected, the control panel reports a trouble condition locally and to the central station (if connected). The wire to the Common terminal is open or missing. If Common is not connected, the control panel reports two trouble conditions locally and to the central station (if connected). There is an alarm. The LED follows the operation of the output relay when the Alarm switch is in the ON (NORMAL) position. If the Alarm switch is in the SILENCE (OFF) position and the module is in alarm, both the SUPERVISION TROUBLE and ALARM LEDs light. Table 3.1: LED operation and troubleshooting 2013.05 03 4.998.122.260 Installation guide Bosch Security Sustems, Inc.

Notification Appliance Circuit Module Notices en 7 4 5 Installation To connect without an external power supply: Mount the module(s) inside the control panel enclosure using the supplied mounting screws. You can use any mounting position. For additional locations, use the D137 Mounting Bracket. Refer to the D137 Installation Instructions. If utilizing the module in a commercial burglary application, use a UL Listed tamper switch (such as the ICP-EZTS Cover Tamper Switch) on the enclosure. If installing the module in a separate UL Listed enclosure such as a D8103, D8108A, or D8109 with a D9002 Mounting Plate, install the enclosure according to the manufacturer s instructions. For information on the mounting plate, refer to the D9002 Installation Instructions. For UL fire applications, mount the module within 20 ft (6 m) of the control panel enclosure with the wiring in conduit between the two. For multiple modules, you can connect up to twelve modules to the same supervision point. The point must use a 1 kω end-of-line (EOL) resistor. Install the 560 Ω, 2 W EOL resistor beyond the last notification device on each NAC loop. This resistor is included with the module. For a supervised point, install a 1 kω EOL resistor across the COM and SUPV ZONE terminals on the last D192G module. Wiring Notice! To ensure system supervision, do not use looped wire under the terminals. Break the run to provide supervision of the connections. Power supplied by the panel The NAC loops are limited in that: Maximum draw for each signaling device circuit is limited by the control panel power supply. No more than 12 D192G modules per system. Power supplied by a remote power supply The auxiliary power supply must be a UL 1481 Listed auxiliary 12 VDC or 24 VDC regulated, power-limited power supply for fire protective signaling units and commercial or residential burglary units. Install the auxiliary supply according to the manufacturer s instructions. Install the control panel and an external power supply in the same room no more than 20 ft (6 m) apart. The interconnecting wiring between the control panel and power supply must be in conduit. The power source for both the power supply and control panel must be from the same dedicated AC branch circuit. The NAC loops are limited in that: Maximum alarm output equals the power supply rating. Maximum draw is 3 A for each annunciating device. No more than 12 D192G modules per system. Bosch Security Sustems, Inc. Installation guide 2013.05 03 4.998.122.260

8 en Notices Notification Appliance Circuit Module 5.1 Wiring the module with G Series control panels 5.1.1 Wiring interconnected loops with 12 VDC power supplied by the panel This wiring scheme allows up to 12 D192G modules (NAC loops) triggered by a single programmed alarm output. Figure 5.1: Wiring interconnected modules to a G Series panel supplying 12 VDC power 1 Last D192G module on the 6 1 kω EOL resistor (P/N: F01U011298) 2 Polarized notification devices 7 Connection to either Relay A or Relay B programmed output 3 560 Ω, 2 W EOL resistors (P/ N: F01U008725) 4 First D192G module on the 8 Connection between module SUPV ZONE and panel zone 9 Connection between module COM and panel s COMMON (not to earth ground) 5 G Series control panel 10 Positive (+) connection from panel s AUX POWER and module s AUX PWR IN and EXT PWR IN terminals 2013.05 03 4.998.122.260 Installation guide Bosch Security Sustems, Inc.

Notification Appliance Circuit Module Notices en 9 5.1.2 Wiring separate loops with 12 VDC power supplied by the panel This wiring scheme allows two separate strings of modules (NAC loops) triggered by separate programmed alarm outputs. Figure 5.2: Wiring separate module loops to a G Series control panel supplying 12 VDC power 1 Last D192G module on the 7 Connection to Relay A programmed output 2 Polarized notification devices 8 Connection to Relay B programmed output 3 560 Ω, 2 W EOL resistors (P/ N: F01U008725) 4 First D192G module on the 9 Connection between module COM and panel s COMMON (not to earth ground) 10 Connection between one module s SUPV ZONE terminal and panel zone 5 G Series control panel 11 Connection between the other module s SUPV ZONE terminal and panel zone 6 Positive (+) connection from panel s AUX POWER and the AUX PWR IN and EXT PWR IN terminals of the modules 12 1 kω EOL resistor (P/N: F01U011298) Bosch Security Sustems, Inc. Installation guide 2013.05 03 4.998.122.260

10 en Notices Notification Appliance Circuit Module 5.1.3 Wiring interconnected loops with 12 VDC or 24 VDC power supplied by an external power supply This wiring scheme allows up to 12 D192G modules (NAC loops) triggered by a single programmed alarm output. Figure 5.3: Wiring interconnected modules to a G Series panel with power supplied by an external power supply 1 Last D192G module on the 8 Negative (-) connection from external power supply and module COM to panel s COMMON (not to earth ground) 2 Polarized notification devices 9 Positive (+) connection between module s ALRM terminal and the power supply 3 560 Ω, 2 W EOL resistors (P/ N: F01U008725) 4 First D192G module on the 10 Conduit required for wiring between external power supply and control panel enclosure 11 Connection to either Relay A or Relay B programmed output 5 G Series control panel 12 Connection between module SUPV ZONE and panel zone 6 UL Listed 12 VDC or 24 VDC regulated, power limited auxiliary power supply 13 1 kω EOL resistor (P/N: F01U011298) 7 Positive (+) connection from panel s AUX POWER to the AUX PWR IN terminals of the modules (to power modules) 2013.05 03 4.998.122.260 Installation guide Bosch Security Sustems, Inc.

Notification Appliance Circuit Module Notices en 11 5.1.4 Wiring separate loops with 12 VDC or 24 VDC power supplied by an external power supply This wiring scheme allows two separate strings of modules (NAC loops) triggered by separate programmed alarm outputs. Figure 5.4: Wiring separate module loops to a G Series panel with power supplied by an external power supply 1 D192G modules on separate NAC loops 8 Negative (-) connection from external power supply and module COM to panel s COMMON (not to earth ground) 2 Polarized notification devices 9 Positive (+) connection between module s EXT PWR IN terminal and the power supply 3 560 Ω, 2 W EOL resistors (P/ N: F01U008725) 4 UL Listed 12 VDC or 24 VDC regulated, power limited auxiliary power supply 10 Conduit required for wiring between external power supply and control panel enclosure 11 Connection to Relay B programmed output to ALRM TRG of the other module 5 G Series control panel 12 Connection between one module s SUPV ZONE terminal and an on board point on the control panel 6 Positive (+) connection from panel s AUX POWER to the AUX PWR IN terminals of the modules 7 Connection to Relay A programmed output to ALRM TRG of one module 13 Connection between the other module s SUPV ZONE terminal and an on board point on the control panel 14 1 kω EOL resistor (P/N: F01U011298) Bosch Security Sustems, Inc. Installation guide 2013.05 03 4.998.122.260

12 en Notices Notification Appliance Circuit Module 5.2 Wiring the module with B Series control panels 5.2.1 Wiring interconnected loops with 12 VDC power supplied by the panel This wiring scheme allows up to 12 D192G modules (NAC loops) triggered by a single programmed alarm output. Figure 5.5: Wiring interconnected modules to a B Series panel supplying 12 VDC power 1 Last D192G module on the 7 D134 Dual Relay Module (as example) 2 Polarized notification devices 8 Positive (+) connection between panel s aux power and module s aux and ext power terminals 3 560 Ω, 2 W EOL resistors (P/ N: F01U008725) 4 First D192G module on the 9 Connection to module s ALRM TRG terminal 10 Connection between module s SUPV ZONE and panel zone 5 B Series control panel 11 Connection between module COM and panel s digital COM (not to earth ground) 6 Connection to either B or Relay B programmed output 12 1 kω EOL resistor (P/N: F01U011298) 2013.05 03 4.998.122.260 Installation guide Bosch Security Sustems, Inc.

Notification Appliance Circuit Module Notices en 13 5.2.2 Wiring separate loops with 12 VDC power supplied by the panel This wiring scheme allows two separate strings of modules (NAC loops) triggered by separate programmed alarm outputs. Figure 5.6: Wiring separate module loops to a B Series control panel supplying 12 VDC power 1 Last D192G module on the 9 Connection between one module s SUPV ZONE and panel zone 2 Polarized notification devices 10 Positive (+) connection between panel s aux power and the aux and ext power terminals of the modules 3 560 Ω, 2 W EOL resistors (P/ N: F01U008725) 4 First D192G module on the 11 D134 Dual Relay Module 12 Connection between the other module s SUPV ZONE and panel zone 5 B Series control panel 13 Connection between both module COM terminals and panel s digital COM (not to earth ground) 6 Connection to C programmed output 14 Connection to the other module s ALRM TRG terminal 7 Connection to B programmed output 15 1 kω EOL resistor (P/N: F01U011298) 8 Connection to one module s ALRM TRG terminal Bosch Security Sustems, Inc. Installation guide 2013.05 03 4.998.122.260

14 en Notices Notification Appliance Circuit Module 5.2.3 Wiring interconnected loops with 12 VDC or 24 VDC power supplied by an external power supply This wiring scheme allows up to 12 D192G modules (NAC loops) triggered by a single programmed alarm output. Figure 5.7: Wiring interconnected modules to a B Series panel with power supplied by an external power supply 1 Last D192G module on the 8 Positive (+) connection between panel s aux power and module s aux and ext power terminals 2 Polarized notification devices 9 Connection to module s ALRM TRG terminal 3 560 Ω, 2 W EOL resistors (P/ N: F01U008725) 4 First D192G module on the 10 Connection between module s SUPV ZONE and panel zone 11 Connection between module COM and panel s digital COM (not to earth ground) 5 B Series control panel 12 Conduit required for wiring between external power supply and control panel enclosure 6 Connection to either B or Relay B programmed output 13 UL Listed 12 VDC or 24 VDC regulated, power limited auxiliary power supply 7 D134 Dual Relay Module (as example) 14 1 kω EOL resistor (P/N: F01U011298) 5.2.4 Wiring separate loops with 12 VDC or 24 VDC power supplied by an external power supply This wiring scheme allows two separate strings of modules (NAC loops) triggered by separate programmed alarm outputs. 2013.05 03 4.998.122.260 Installation guide Bosch Security Sustems, Inc.

Notification Appliance Circuit Module Notices en 15 Figure 5.8: Wiring separate module loops to a B Series panel with power supplied by an external power supply 1 Last D192G module on the 10 Positive (+) connection from one relay s X1+ and COM terminals and the aux and ext power terminals of one module and the positive (+) terminal of the power supply 2 Polarized notification devices 11 Connection between both module s COM terminals, the power supply s negative (-) terminal, and the panel s digital COM (not to earth ground) 3 560 Ω, 2 W EOL resistors (P/ N: F01U008725) 4 First D192G module on the 12 Connection between the other module s SUPV ZONE and panel zone 13 Connection to the other module s ALRM TRG terminal 5 B Series control panel 14 Positive (+) connection from the other relay s X1+ and COM terminals and the aux and ext power terminals of the other module and the positive (+) terminal of the power supply 6 Connection to C programmed output 15 D134 Dual Relay Module 7 Connection to B programmed output 16 Conduit required for wiring between external power supply and control panel enclosure 8 Connection to one module s ALRM TRG terminal 17 UL Listed 12 VDC or 24 VDC regulated, power limited auxiliary power supply Bosch Security Sustems, Inc. Installation guide 2013.05 03 4.998.122.260

16 en Notices Notification Appliance Circuit Module 9 Connection between one module s SUPV ZONE and panel zone 18 1 kω EOL resistor (P/N: F01U011298) 2013.05 03 4.998.122.260 Installation guide Bosch Security Sustems, Inc.

Notification Appliance Circuit Module Notices en 17 6 6.1 Programming Supervisory zone Several options are available to program the module s supervision point. Program the point using a point index configured as: Point Type 0 (24 h) Pt Response 9 Short = Fire Supervision; Open = Fire Trouble Buzz on Fault = 2 Fire = Yes Program all other selections for the point index number No. 6.2 7 Alarm output For instructions on programming the control panel, refer to the panel's Program Entry Guide. For compatibility information about synchronization modules and strobes, refer to the panel's Approved Applications Compliance Guide. Specifications Electrical Current: Maximum draw 100 ma Maximum rating of the module alarm circuit 3 A Voltage AUX PWR IN 12 VDC nominal EXT PWR IN 12 VDC or 24 VDC supplied by an external regulated, powerlimited power supply, or 12 VDC supplied by the control panel s AUX PWR terminal for special applications. Mechanical Dimensions (LxWxD) 5 in. x 3 in. x 0.75 in. (12.7 cm x 7.6 cm x 1.9 cm) Bosch Security Sustems, Inc. Installation guide 2013.05 03 4.998.122.260

Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.com Bosch Security Systems, Inc., 2013