Chemical Transfer Pump Tube Set and Adapter Instructions

Similar documents
CER-1 / CER-2 (MV-1 / MV-2) (CLM-5001X / CLM-5002VX)

SITE REQUIREMENTS & INSTALLATION DSD-201 & SSD-102

Attendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

Endoscope Reprocessor Installation Instructions Endoscope Reprocessing System

2015 Myco Industries, Inc Fax:

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

CER-1 & CER-2 Installation & Testing Instructions

CER-1 & CER-2 Site Requirements

CER OPTIMA. Endoscope Reprocessing System CER-1 & CER-2 Site Requirements. Introduction. Space Requirements

Bravo Display Warning Messages

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

PRE INSTALLATION PROCEDURES

Site Requirements. MODEL 2.0 Australia

ENDOSCOPE REPROCESSOR OER-Pro Operation Manual

Medical Equipment Washer Information & Setup

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

KD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea

Site Requirements ADVANTAGE PLUS

OPERATION MANUAL. (Cleaning, Disinfection and Storage) Endoscope ED-530XT

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

Cleaning and Sanitation Procedures Module Deli

FLOOR FINISH. Extended Performance Floor Finish

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Welcome! Today s topic: Small Home Repairs. November 14, 2015

PRE INSTALLATION PROCEDURES

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Start the cleaning from Left and finish at Right. Always do the floor last, start from inside and finish at doors

DISPENSING TROUBLESHOOTING INDEX

PLANT OPERATIONS CLEANING PROTOCOL

Instructions for use Vacuum regulation valve with water trap

10. Water Dispensers

Cleaning and Sanitation Procedures Module Cafe/Dining Restroom

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

Blue Caffé P hone Fax

1 Intended Use of the Breas HA 01 Humidifier

AQ-4000 Series Information & Setup

Washroom care programs

Water Pre-Filtration System Installation Instructions Endoscope Reprocessing Systems

EZ9Plus & EZ11Plus Instructions on: Operating

Plumbing fittings should be hand tightened followed by one complete turn with the appropriate wrench.

Cleaning & Sterilization

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

I.F.U Re/Processing Reusable Medical Devices

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

TBJ Model SPCS B Scope Pre-Cleaning Sink. Product Specification. Product Description

OPERATION MANUAL KLEENSCREEN FILTRATION SYSTEM SUPPLEMENT INSTRUCTION MANUAL FOR: Gas Fryer Models. Electric Fryer Models

NBSeries Installation Operation & Maintenance

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

JT-SB116JH-G-NA JT-SB116JH-W-NA

BEFORE OPERATING THE MACHINE: WARNING

TOYOTA RAV BODY SIDE MOLDING Section I - Installation Preparation

Washroom care programs

TCPSeries Installation Operation & Maintenance

DISPENSE TROUBLESHOOTING INDEX. Hot Tank Descaling Instructions are included in this Troubleshooting section.

PRE-INSTALLATION PROCEDURE

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

Quick start guide for Altrix Precision Temperature Management System

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

SELF-CONTAINED CRESCENT CUBER

Cascade Contour Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

INSTALLATION AND OPERATIONS MANUAL

Service Bulletin

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

WL380 QUICK START GUIDE

Commit 2 Clean TM/MC. Bloodborne Pathogens Awareness Program

Industrial Science Seminar

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

HFG 12 and 24 Hydrogen Generators Installation Instructions

Customer Requirements Pre-Installation Instructions

CPAP Washbasin Manual

FLOOR CARE. Avmor s Floor Care Training Guide

Symphony Plus Pressurized Water Sanitizing Kit P/N

If additional information is needed, please contact EDIC at: or

CER OPTIMA. Service Manual. Endoscope Reprocessing System. CER OPTIMA Service Manual

Operating / User Manual

When you sterilize an instrument set, you know what the standards are.

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

STERITITE INSTRUCTIONS FOR USE

D Dissolution Units Mixing Training Course P/N Rev. C

Mixing Training Course P/N Rev. D

Humidifier De-scaling Solution. and Neutralizer. Usage Instructions. IMPORTANT: Read and save these instructions. Before

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Filtration. General Instructions

HYGIENE AND SANITATION

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

Transcription:

Caution: Use personal protective clothing when transferring Liquid Chemical Germicide (LCGs). 1. Recommended Filling Method. Figure 1. TP-1 Transfer Pump DSD-1087 110VAC DSD-1088 220VAC a. Plug the Transfer Pump into a power outlet. b. Connect the Transfer Tube Set MK01-0037 between the pump and the old or new style reservoirs. Refer to Figures 1, 2, 3 and 4. 1) Place the rigid end of tube A into the solution container and the opposite end to the inlet of the TP-1. If using newer reservoir with gray ½-inch connectors: Refer to figure 2 and 3. a) Connect tube B between the outlet of the pump and the reservoir. If using older reservoir with beige 3/8-inch connectors: refer to Figure 2 and 4. a) Connect the Adapter (MA01-0040) to the reservoir connector. b) Connect tube B between the outlet of the pump and the adapter. Document Number MI02-0102 Revision D Page 1 of 5

This end to adapter. Tube A Tube Set MK01-0037 Tube B Adapter MA01-0040 Figure 2. Tube Set and Adapter c. Turn the pump ON at the switch. Note: Ensure that there are no leaks. If leaks are seen, turn the pump OFF. Note: There must be 5 gallons (18.9L) of LCG in the chemical reservoir of all MV and CLM Models 5002V, 5002VX. d. Fill the reservoir until all 5 gallons of LCG have been transferred and turn the pump OFF. e. Flush the Transfer Pump with clear water. Refer to Step 5. Document Number MI02-0102 Revision D Page 2 of 5

2. Alternative Filling Method: Pour 5 gallons (18.9L) of LCG into the reservoir of all MV and CLM Models. Figure 3. New Reservoir Connection Figure 4. Old Reservoir and Adapter 3. Emptying Reservoir using Transfer Pump TP-1 and Tube Set (MK01-0037). Refer to Figure 2. Note: Some regions of the country require neutralization of the solution prior to disposal. If neutralization is not required, refer to Step 4. a. Plug the Transfer Pump into a standard power outlet. b. Connect the Transfer Tube set (MK01-0037) between the pump and the old or new style reservoirs. Refer to Figures 1, 2, 3, and 4. 1) Place the rigid end of tube A into the drain or solution container and the opposite end to the outlet of the TP-1. If using newer reservoirs with gray ½-inch connectors: Refer to Figures 2 and 3 a) Connect tube B between the inlet of the pump and the reservoir. If using older reservoirs with beige 3/8-inch connectors: Refer to Figures 2 and 4. a) Connect the Adapter (MA01-0040) to the reservoir connector. b) Connect tube B between the inlet of the pump and the adapter (MA01-0040). c. Turn the pump ON at the switch. Note: Ensure that there are no leaks. If leaks are observed, turn the pump OFF. d. Continue to pump until all of the LCG has been pumped out of the reservoir. (You might need to lift one end to remove all chemicals.) e. Turn the pump OFF. f. Flush the Transfer Pump with clear water. Refer to Step 5. Document Number MI02-0102 Revision D Page 3 of 5

4. Emptying Manually. a. Press MANUAL, LCG/IN, and START. b. When the disinfectant in the basin has reached maximum fill level, liquid will no longer rise. c. Press Manual, DRAIN and START. d. When the chemical has been drained from the basin, press STOP. e. Repeat Step a. When air bubbles begin to form in the basin and all the chemicals have been pumped from the reservoir, press STOP. f. Press MANUAL, DRAIN and START. g. When all chemicals in the basin have been drained, press STOP. h. Remove remaining chemicals from the reservoir using a suction pump or rubber gloves and absorbent lint free cloths. i. Rinse the chemical from the basin and dilute chemicals in the drain, by turning the reprocessor ON and pressing START. Allow the reprocessor to complete the wash cycle and the rinse cycle if necessary. j. Press STOP. 5. Flushing the Transfer Pump and All Tubing. a. Connect the adapter (MA01-0040) to the Transfer Pump Tubing. Refer to Figure 2. b. Place the adapter into the drain. c. Connect the remaining end of the tubing to the outlet of the pump. d. Connect tube A to the inlet of the pump. Refer to Figure 1, 2. e. Place the inlet tubing into a container of fresh water. f. Turn the pump ON and flush the system with fresh water. g. Remove the tubing from the fresh water until all the water is pumped from the tubing. h. Turn the pump OFF and disconnect the tubes. Document Number MI02-0102 Revision D Page 4 of 5

6. Recommended LCGs Note: It is the responsibility of the reprocessor operator to insure the effectiveness of the high-level disinfectant used. Medivators recommends the use of a LCG that: Has a 510K approval to market certification from the FDA. Is approved for use with flexible endoscopes by the endoscope manufacturers. It is the user's responsibility to ensure that the LCG is used for the proper time and temperature to effect high-level disinfection or sterilization. Medivators recommends daily testing of the LCG to ensure an adequate level of active ingredient. Use the manufacturer s test strips to test the potency of the high level disinfectant on a daily basis. If the minimum effective concentration (MEC) of the high-level disinfectant is below its minimum, discard and replace with fresh high-level disinfectant. Document Number MI02-0102 Revision D Page 5 of 5