Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Similar documents
BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Flameproof Type Light Curtain Type 4

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Improved productivity Two-stage detection

Small Light Curtain. Industry s smallest Type 4 light curtain for safeguard SERIES

E3M-V. Mark Sensor. Applications

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Electron Microscopy Sciences

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Improved productivity Two-stage detection

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Fire Alarm System Accessories

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

Laser Collimated Beam Sensor

Safety Light Curtains Area Access Control

Switches compliant with ATEX directive

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Fire Alarm System Accessories

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

VSD AND SS DRIVING ATEX MOTORS February 2014

Ultrasonic Proximity Sensor

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Meets Global Standards

1. GENERAL TECHNICAL INFORMATION

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

INSTRUCTION MANUAL. Handy Controller Exclusive for SF4B / SF4B<V2> Series. SFB-HC Ver.2.1 FUNCTION CANCEL ENTER

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

E3FA PHOTOELECTRIC SENSORS

Advanced Ultraviolet Burner Controller

Snifter ATEX22 VERSION. User Manual. Distributor

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

Explosion-proof Duct Heaters

INSTRUCTION MANUAL (ATEX / IECEx)

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

Explosion-protected actuator Page 259 of 292

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

ESD3000IR ESD3000IR. Infrared Gas Detector

ATEX Safety Switches. More than safety.

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

For full product information, visit Use the SpeedSPEC Code for quick access to the specific web page. Global Support

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

onlinecomponents.com

ESD500. ESD500 Combustible / Toxic Gas Detector

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

SensaGuard TM Integrated Latch Installation Instructions

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

AUR300C. Advanced Ultraviolet Burner Controller

standards: standards:

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Relays for use in hazardous locations. Class I, Division 2 and ATEX

ESD3000 ESD200 Combustible / Toxic Gas Detector

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Snifter. User Manual. Distributor

E3FA PHOTOELECTRIC SENSORS

Guide for hazardous areas

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

/ / 2018

Ultrasonic Reflective Sensor

INSTRUCTION & SERVICE MANUAL

NGD8800 USER S MANUAL

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Ultrasonic Reflective Sensor

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Sintrol Snifter A1+ Manual. Version 1.2.2

Ultrasonic Proximity Sensor

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m.

RE-PR3-E-27 3-Phase Panel Mount 27kW

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

Combustible Gas Detection and Control System

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL (ATEX / IECEx)

Optical system Beam shape Sensing distance Resolution*1 Model Diffuse reflective Spot beam 40±10 mm 2 µm ZX-LD40. Line beam 40±10 mm 2 µm ZX-LD40L

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

Operating Manual MS220KA and MSR220KA

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Transcription:

597 Flameproof Type Light Curtain Type 4 General terms and conditions... F-3 Related Information guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P.1595 PHOTO PHOTO Certified Listing MEASURE Category 4 PLe SIL3 panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit. Globally-compliant flameproof structure * Please contact us about the type approval No. in China. Light Complies with worldwide flameproof standards The safety light curtain is built into a highly flameproof enclosure conforming to the IEC 61496 (Type 4). The safety light curtain can be safely used in any workplace throughout the world where flameproof performance is required. Europe United States Canada Russia China Japan Complies with flameproof structures (Exd II BT6) specified by IEC 60079, EN 60079-0, EN60079-1 and ATEX Directives (94/9/EC). Complies with flameproof structures (Class I Zone 1 AExd II BT6) specified by FM 3600 (ISA. 12.22.01). Complies with flameproof structures (Exd II BT6) specified by CAN/CSA-E79-0 (CAN/CSA-E79-1). Complies with the Russian standard GOST R IEC60079-0, GOST IEC60079-1 which is based on the international standard. Complies with China s standard GB 3836.1/2 (Exd II BT6) conforming to international standards. Complies with technical standard (Exd II BT6) conforming to international standards. Ample protective height 1,595 mm 62.795 in A single safety light curtain is sufficient for production lines with high working heights such as vehicle body spray-painting lines. Operating range: 6 m 19.685 ft Protective height 1,595 mm 62.795 in Cable gland (Internal thread 1/2 NPT) [Gland adapter (Internal thread G 1/2 ) is attached] Cable length 20 m 65.617 ft 76 mm 2.992 in 80 mm 3.150 in Hazardous s: Zone 1, Zone 2 Classification of gas or vapor, and Temperature classification: II BT6

Flameproof Type Light Curtain 598 Mounting bracket enables easy beam-axis alignment The beam-axis alignment is easy since angle adjustment is possible with the enclosed rear mounting bracket. ORDER GUIDE Rear mounting bracket Less operating errors from extraneous light interference A double-scanning method and retry processing are some unique new technology that help to avoid momentary interference from extraneous light coming from nearby equipment. A reduction in operating errors resulting from extraneous light interference can mean less frequent machinery stoppages and reduces the amount of time that a production line is not running. Mutual interference is reduced without the need for interference prevention lines No interference prevention lines are required between different items of equipment, so that safety light curtains can be installed with greater flexibility. Unaligned beam axes can be seen at a glance The beam-axis alignment indicators are distributed on the safety light curtains in four sections. As the indicators of the sections whose beam channels are aligned light up in red, the user can easily verify which beam channel axes have become aligned. Once all beam channels have become aligned, the indicators light up in green. When the upper half of all beam channel axes are aligned Upper two indicators: ON Lower two indicators: OFF Even though beam channels are only partially aligned, the user can determine which beam channels are aligned Beam axes of two upper blocks are aligned / ( beam axes of two lower blocks are not aligned ) The bottommost beam channel axis is correctly aligned Indicator at bottommost blinks red Blinking light curtain Type Operating range (Note) Model No. Number of beam channels Protective height (mm in) 20 mm 0.787 in beam pitch 0.3 to 6 m 0.984 to 19.685 ft 80 1,595 62.795 Note: The operating range is the possible setting distance between the emitter and the receiver. Control unit Designation Appearance Model No. Description Slim type control unit Note: Refer to SF-C10 series pages (p.663~) for SF-C13. SF-C13 (Note) For PNP/NPN equivalent output type safety light curtain. Compatible with Control Category 4. Use in a safe. Light

599 Flameproof Type Light Curtain SPECIFICATIONS Refer to p.667 for details of the specifications for SF-C13. Light Item Applicable flameproof standards Model No. Europe: IEC 60079, EN 60079-0, EN60079-1, North America: FM 3600 (ISA.12.22.01), Canada: CAN/CSA-E79-0 (CAN/CSA-E79-1), Russia: GOST R IEC60079-0, GOST IEC60079-1, China: GB 3836.1/2, Japan: Technical standard conforming to international standards CE marking directive compliance ATEX Directive, Machinery Directive, EMC Directive, RoHS Directive Flameproof capability USA: Class I Zone 1 AExd II BT6, Europe / Canada / Russia / China / Japan: Exd II BT6 Setup Hazardous s such as Zone 1 or Zone 2 where II BT6 gases or vapors may be present (Note 2) Applicable standards ISO 13849-1 (Category 4, PLe), EN ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 4 (SIL 3), EN 50178, EN 55011, EN 61000-6-2, EN 61496-1 (Type 4), IEC 61496-1/2 (Type 4), UL 61496-1/2 (Type 4), UL 1998, CAN/CSA-C22.2 No. 14 / No. 0.8 Protective height 1,595 mm 62.795 in Beam pitch / Operating range 20 mm 0.787 in / 0.3 to 6 m 0.984 to 19.686 ft Min. sensing object ø30 mm ø1.181 in opaque object Effective aperture angle ±2.5 or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)] Supply voltage 24 V DC ±10 % Ripple P-P 10 % or less Current consumption : 130 ma or less, : 125 ma or less Control outputs (OSSD1, OSSD2) Operation mode / Protection circuit Response time Auxiliary output (Non-safety output) Indicators Operation mode / Protection circuit Test input (emission halt) function Test input (emission halt input) Degree of protection Environmental resistance Ambient temperature / Ambient humidity Semiconductor output (PNP output equivalent) 2 outputs Maximum source current: 200 ma Applied voltage: Same as supply voltage (between control output and +V) Residual voltage: 2.5 V or less (at 200 ma source current) ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) / Incorporated OFF response 11 ms or less, ON response 70 ms or less PNP open-collector transistor Maximum source current: 60 ma Applied voltage: Same as supply voltage (between auxiliary output and +V) Residual voltage: 2.5 V or less (at 60 ma source current) OFF when control outputs are ON, ON when control outputs are OFF / Incorporated Beam-axis alignment indicators: 2-color LED 4 (lights up in red when each beam channel receives light, blinks in red when the topmost or bottommost beam channel receives light, lights up in green when all beam channels receive light), Operation indicator (Note 3): 2-color LED (lights up in red when control outputs are OFF, lights up in green when control outputs are ON), Emission halt / Emission amount control indicator (Note 4): 2-color (Orange / Green) LED [lights up in green during stable light incidence (incident light intensity approx. 115 % or more of control output operation level), off during unstable light incidence (incident light intensity approx. 100 % to 115 % of control output operation level) or when light is interrupted, blinks in orange when light emitting halted], Fault indicator: Yellow LED (lights up or blinks if a fault occurs in the safety light curtain) Beam-axis alignment indicators: 2-color LED 4 (lights up in red when each beam channel receives light, blinks in red when the topmost or bottommost beam channel receives light, lights up in green when all beam channels receive light), OSSD indicator: 2-color LED (lights up in red when control outputs are OFF, lights up in green when control outputs are ON), Blanking indicator: Orange LED (Note 4) (No use), Fault indicator: Yellow LED (lights up or blinks if a fault occurs in the safety light curtain) Incorporated Emission: +9 V to Vs (sink current: 2 ma or less) (Note 5), Emission halt: Open, or 0 to +1.5 V IP65 (IEC) 10 to +40 C +14 to +104 F (No dew condensation or icing allowed), Storage: 20 to +55 C 4 to +131 F / 45 to 85 % RH, Storage: 45 to 85 % RH Ambient illuminance Incandescent light: 3,500 lx or less at the light-receiving face Dielectric strength voltage 1,000 V AC for one min. between all supply terminals connected together and safety light curtain grounding terminal (Note 6) Insulation resistance 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and safety light curtain grounding terminal (Note 6) Vibration resistance 10 to 55 Hz frequency, 0.35 mm 0.014 in double amplitude in X, Y and Z directions for 20 times each Shock resistance 100 m/s 2 acceleration (10 G approx.) with pulse width 16 ms in X, Y and Z directions 1,000 times each Altitude (Atmospheric pressure) 2,000 m 6561 ft or less (800 to 1,100 hpa) Emitting element Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) Flameproof enclosure: Aluminum, Lid: Aluminum die-cast, Clear window: Glass, Window frame: Steel plate (Black chromate) Material Window packing: Chloroprene, light curtain mounting bracket: Steel plate (Black chromate), Cable: Oil-resistant PVC, Cable Gland: Brass (Nickel plated) Cable 6-core (0.3 mm 2 4-core, 0.2 mm 2 2-core) oil resistant shielded cable, 20 m 65.617 ft long Weight (Total of emitter and receiver) Net weight: 44 kg approx. Accessories Rear sensor mounting bracket: 1 set for emitter and receiver, Test rod: 1 pc. Gland adapter (Internal thread G 1/2): 2 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) Install the product in a where it is less likely to suffer mechanical damage. 3) Since the color of the operation indicator changes according to the ON/OFF state of the control outputs (OSSD1, OSSD2), the operation indicator is marked as OSSD on the sensor. 4) The Handy-controller (SF-HC)(discontinued model) cannot be used with this device, so that the emission amount control function and the blanking indicator function cannot be used. Furthermore, series connection is not possible. 5) Vs is the same value as the voltage of the used power supply to be used. 6) This device has a surge absorber connected between the device case and supply terminals to prevent faulty operation due to application of lightning surge noise. For this reason, the values for dielectric strength voltage and insulation resistance are given for the condition when the surge absorber has been removed.

Flameproof Type Light Curtain 600 I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Sensor circuit Sensor circuit Internal circuit Color code (Brown) +V (Pink) Test input (emission halt input) 60 ma max. (Gray) Auxiliary output (Blue) 0 V (Orange) Synchronization + (Orange / Black) Synchronization Users circuit (Orange / Black) Synchronization (Orange) Synchronization + (Brown) +V (Black) OSSD1 200 ma max. 200 ma max. (White) OSSD2 FSD2 (Blue) 0 V Load *1 FSD1 + 24 V DC ±10 % * 1 CAUTION Use a safety relay unit or an equivalent safety control circuit for FSD. Non-voltage contact or PNP open-collector transistor Note: Vs is same voltage as the voltage of the power supply to be used. or Test input (emission halt input) Low (open, or 0 to +1.5 V): Emission halt High (+9 V to Vs) : Emission (sink current: 2 ma or less) (Note) Internal circuit Users circuit Wiring diagram of the SF-C13 (Control category 4) SF-C13 Terminal arrangement diagram terminal (Note 3) terminal (Note 3) Synchronization + (Orange) Auxiliary output (Gray) +V (Brown) +V +24 V DC 0 V Emission halt input (Brown) 0 V (Blue) (Pink) (Blue) Load A1 Ui Synchronization (Orange / Black) F S1 OSSD1 (Black) OSSD2 (White) S2 S3 RESET (Note 2) SF-C13 control circuit (Note 1) S4 X1 X2 X3 L1 F1 F2 13 23 33 41 K1 A1 A2 S1 S2 S3 S4 AUX X1 X2 X3 13 14 23 24 33 34 41 42 Light A2 0 V F.G. AUX OUT INTER_LOCK K2 ULT 14 24 34 42 KA, KB: Magnet contactor KB KA N L1 L2 L3 M 3 KB KA Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the read from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch for the reset (RESET) button. 3) Ground the grounding terminal of without fail.

601 Flameproof Type Light Curtain PRECAUTIONS FOR PROPER Refer to p.1595 for general precautions. Light Do not utilize this safety light curtain in PSDI Mode, in which the safety light curtain is utilized as an activator for machinery. To use this product in the U.S.A., refer to OSHA 1910. 212 and OSHA 1910. 217 for installation, and in Europe, refer to EN ISO 13855 as well. Observe your national and local requirements before installing this product. This catalog is a guide to select a suitable product. Be sure to read the instruction manual prior to its use. Cautions for explosion-protection This device has a flameproof structure and explosionproof performance that can only be ensured when the product meets all of the specified conditions and specifications. Failure to observe any of them will result in the loss of the explosionproof performance. Use flameproof electric appliances that are compatible with hazardous s (s where an explosive atmosphere of gas or vapor may exist). Make sure that the power supply is off while wiring. Otherwise, electric shock may result. Never modify or repair the product yourself. Failure to follow this instruction may result in an explosion or ignition. Protect the cables, or external conductors, against possible external damage by passing them through a sufficiently strong metallic tube or by other means. Ground the grounding terminal without fail. Failure to follow this instruction may result in an explosion or ignition. Do not open the lid of the flameproof enclosure, and do not remove the window frame fixtures of the enclosure. Failure to follow this instruction may result in an explosion or ignition. The product can be used in Zone 1 or Zone 2 areas where explosive gases may exist and flameproof appliances in groups IIA and IIB and temperature classifications of T1 to T6 can be used. Never install in s which are classified as 0 (Zone 0). For the classification of hazardous s and flameproof electric appliances, see each country s electric equipment construction work principles and other related laws and regulations. If the wiring is expected to be subjected to electromagnetic or electrostatic induction from the general circuits, separately protect it with a metallic tube or duct. Hazardous Metallic duct, etc. Safe ( ) SF-C13 Install the product in a where it is less likely to suffer mechanical damage. Mounting When mounting the safety light curtain, secure it in place using four M10 bolts. The cable lead-in port is threaded for wiring protective tube or conduit (NPT 1/2). Using a steel wire tube etc., if necessary, screw a tube into the port at least five complete threads. After beam alignment, tighten the hexagon-sockethead bolts for adjusting mounting angle for fixing. The recommended tightening torque is 1.5 to 1.7 N m. (The hexagon-socket-head bolts for adjusting mounting angle are on top and bottom surfaces of the emitter and receiver.) Ground the external grounding terminal on the flameproof enclosure to keep the grounding resistance at or 100 Ω. For grounding, use an electric wire with equivalent or higher insulation performance to a 600 V polyvinylinsulated electric wire, and of a thickness ensuring safe carrying of the expected maximum ground current. Others This device has been developed / produced for industrial use only. Use the device according to the specifications of this product. Failure to follow this instruction may result in electric shock, injuries, or damage to the product. Unpack the product with the right side facing up. If you do not follow this instruction, you may get injured. Do not touch any terminals when measuring the insulation resistance. Failure to follow this instruction may result in electric shock. If there is something abnormal with the product, immediately turn OFF the product. Otherwise, electric shock, injuries, or a fire may result. Before measuring the insulation resistance, confirm that there is no explosive atmosphere of gases or vapor around. Failure to follow this instruction may result in an explosion or ignition.

Flameproof Type Light Curtain 602 PRECAUTIONS FOR PROPER Refer to p.1595 for general precautions. Reference Classification of Class (North America only) Hazardous atmosphere is classified as follows. Classification Hazardous atmosphere Use of Classification of hazardous s Zone Classification Zone 0 Zone 1 Zone 2 Class I Gas or vapor Can be used Class II Dust Cannot be used Class III Fiber Floating particles Cannot be used Classification of Group Hazardous atmosphere A where a hazardous atmosphere exists continuously or for a long period of time (100 hours or longer per year) under normal conditions. A where a hazardous atmosphere is expected to be generated under normal conditions (a where a hazardous atmosphere is expected to exist for one to 100 hours per year). A where a hazardous atmosphere is expected to be generated under abnormal conditions (a where a hazardous atmosphere is expected to exist for less than one hour per year). Use of Cannot be used Can be used Can be used Electric appliances are classified into the following groups in terms of explosive atmospheres: Classification Group I Group II Hazardous atmosphere Electric appliances for mines that are likely to generate firedamp. Electric appliances for s with an explosive atmosphere, except for mines that are likely to generate firedamp. DIMENSIONS (Unit: mm in) Use of Cannot be used Can be used Classification of Gas Excerpted from the to Explosion-proof Electric Machine and Appliance Type Verification (Related Technical Standards Consistent with Global Standards, Japan). In general, the temperature classes and gas or vapor categories of the representative explosive gases frequently used by plants are as shown in the table : Classification of gas or vapor Temperature classification T1 T2 T3 T4 T5 T6 Flash point A Over 450 C 842 F Aceton Ammonia Carbon monoxide Ethane Acetic acid Ethyl acetate Toluene Propane Benzen Methanol Methane Over 300 C 572 F, Over 200 C 392 F, Over 135 C 275 F, Over 100 C 212 F, Over 85 C 185 F, 450 C 842 F and 300 C 572 F and 200 C 392 F and 135 C 275 F and 100 C 212 F and Ethanol Vinyl acetate 1-butanol Butane Acetic anhydride B Coal gas Ethylene Ethylene oxide C Octane Hexane Acetaldehyde Water gas Hydrogen Acetylene Carbon disulfide Ethyl nitrate Note: can be used in the area of A to B (Classification of gas or vapor) and T1 to T6 (Temperature classification). The CAD data can be downloaded from our website. Assembly dimensions Mounting drawing with the gland adapter (Internal thread G 1/2) 38 ( 1.496 ) 69 2.717 75 2.953 SF4-AH80 Gland adapter (Internal thread G 1/2) 9 0.354 67 2.638 38 1.496 ø6 ø0.236 cable, 20 m 65.617 ft long Cable gland (Internal thread NPT 1/2) t 4 t 0.157 1,718 67.638 10.8 0.425 Beam-axis alignment indicator Operation indicator Emission halt / Emission amount control ind. (Orange / Green) Error indicator (Yellow) M4 grounding terminal 5 66 55 2.598 2.165 5 t 4 t 0.157 86 3.386 46 1.811 80 3.150 52 2.047 Protective height Beam pitch 20 0.787 71 2.795 6.5 0.256 31.4 1.236 25 0.984 10.5 0.413 40 1.575 68 2.677 1,595 62.795 101 3.976 1,778 70.000 15 0.591 1,808 71.181 R30 R1.181 Hexagon-socket-head bolt for adjusting mounting horizontal angle Beam-axis alignment indicator OSSD indicator Blanking indicator (No use) Error indicator (Yellow) Light