Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

Similar documents
Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

Certified Passive House Component For cool, temperate climates, valid until 31 December 2017

Renovent Sky 300 (Plus)

Zehnder ComfoAir flat 150

BRINK Renovent HR Installation and Operation Manual

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

Renovent Excellent 450 (Plus)

Renovent Excellent 180 (Plus)

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

GASTEC QA. Approval Requirements 201. Amendment A1. for the GASTEC QA product certificate for Gas service lines to residences and buildings

Demand ventilation 2.0

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC

Certifikat och provningsprotokoll för art och 4511

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical

CI/SfB (57.5) November 2008

GASTEC QA. Approval Requirements 31-2

GASTEC QA. Approval Requirements 31-1

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

GASTEC QA. Approval Requirements 136

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

Ventilation Unit Zehnder ComfoAir 350

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

Air Comfort. Installation instructions (English) A

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

Koja Oy. manufactures ventilation units Fair 80 ec

Ventilation unit Zehnder ComfoAir 160

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Healthy, comfortable and energy-efficient ventilation

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

KN-KWL 110 SE-EC Kontrollierte Wohnraumlüftung KN

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

GASTEC QA. Approval Requirements 6

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Healthy, comfortable and energy-efficient ventilation

Evap WTW INSTALLATION INSTRUCTIONS D

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

Overview and Specifications

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

TNO report MON-RPT-033-DTS

HCV 4 - HCV 5 - HCH 5 - HCH 8

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

SYSTEM VENTECH LG 250

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Operation and maintenance instructions

DEMAND-CONTROLLED HOME VENTILATION

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Zehnder ComfoAir 550. Ventilation unit

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

Building Regulations 2010: What it means to you.

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

GASTEC QA. Approval Requirements 69-1

BRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers

BRL-K602. Datum Evaluation Guideline

SoaSA Technology International Ltd. Unit E,19/F, 2nd Wuhan Building Jiahe Road, Xiamen, Fujian China

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

DATA SHEET 01. Function. Features SUP. OUT EX optional OUT EX OUT SUP OUT SUP. Customized connection possibilities as standard.

Energy recovery unit. Projection documents

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Ventilation unit Zehnder ComfoAir 200

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

2013 innovation. Room-by-room demand controlled heat recovery ventilation

Kiwa Regulations for Certification in accordance with the CPR

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

VENTILATION WITH HEAT RECOVERY

Always the best climate for the IDEAL INSTALLATION

KOMFORT EC DB Suspended heat recovery air handling units

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances

HRV Enthalpy. Catalogue

Transcription:

Technical Sheet Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

Application The Brink Renovent Excellent is a ventilation unit with heat recovery with an efficiency of 95%, a maximum ventilation capacity of 300 or 400 m 3 /h and low-energy fans. Features Renovent Excellent: steplessly adjustable air flow rates through a control panel; filter indication on the appliance and the possibility for filter indication on the multiple switch; a completely new intelligent frost protection system which ensures that also at low outdoor temperatures the appliance's performance remains optimal and that, if necessary, it activates the standard preheater. low sound level comes as standard with automatic bypass valve constant flow control low energy consumption high efficiency These installation instruction describe both the standard Renovent Excellent and the Renovent Excellent Plus. The Renovent Excellent (Plus) is available in the left-handed or right-handed version. A left-handed version has the filters on the left behind the filter door; a right-handed version has the filters on the right behind the filtered door. The position of the air ducts differs for these two versions! For the correct position of the connection ducts and dimensions see page 5. When ordering an appliance always state the correct type; subsequent conversion to a different version is not possible. The Renovent Excellent comes ready to plug in with a 230 V mains plug and a connection for a low-voltage multiple switch on the outside of the appliance. Renovent Excellent 300/400 is available in two types: Renovent Excellent Renovent Excellent Plus Compared to the Renovent Excellent, the Renovent Excellent Plus has a more extensive control board which increases the connection options. Note: When replacing a Renovent Large by a Renovent Excellent, do realise that the positions of the ducts From dwelling and From atmosphere are different! (only for type 4/0 & 3/1) Carefully check the position of these ducts on the basis of the connection drawings on page 5. Version types Renovent Excellent 300/400 Type Version L of R Position air ducts Power supply Type code 4 top connections Power plug 4/0 L Left-handed version 2 top connections & 2 bottom connections Power plug 2/2 L Renovent Excellent 3 top connections & 1 bottom connection Power plug 3/1 L 4 top connections Power plug 4/0 R Right-hand version 2 top connections & 2 bottom connections Power plug 2/2 R 3 top connections & 1 bottom connection Power plug 3/1 R 4 top connections Power plug 4/0 L+ Left-handed version 2 top connections & 2 bottom connections Power plug 2/2 L+ Renovent Excellent Plus 3 top connections & 1 bottom connection Power plug 3/1 L+ 4 top connections Power plug 4/0 R+ Right-hand version 2 top connections & 2 bottom connections Power plug 2/2 R+ 3 top connections & 1 bottom connection Power plug 3/1 R+ Renovent Excellent 400 2

Version Technical information Renovent Excellent 400 Supply voltage [V/Hz] 230/50 Protection degree IP30 Dimensions (w x h x d) [mm] 675 x 765 x 564 Duct diameter [mm] External diameter condensate discharge [mm] Ø180 Ø32 Weight [kg] 38 Filter class G3 (F7 optional for supply) Fan setting (factory setting) 1 2 3 Ventilation capacity [m 3 /h] 50 100 200 300 Permissible resistance ducts system [Pa] 3-6 6-20 25-49 56-178 Rated power (excl. preheater)[w] 8,6 9.5-15 29-40 72-98 Rated current (excl. preheater)[aa] 0,10 0.12-0.14 0.24-0.31 0.51-0.7 Max. rated current (with preheater switched on) [A] 6 Cos φ 0,38 0.45-0.40 0.56-0.58 0.60-0.61 Packaging Packaging unit per pallet 2 Warranty period 2 years on parts and 5 years on the heat exchanger. Sound power Sound power Excellent 400 Ventilation capacity [m 3 /h] 100 200 225 300 400 Sound power Static pressure [Pa] 9 40 38 80 47 100 84 175 240 150 225 level Lw (A) Housing emission [db(a) 28.5 31.5 39.5 40.5 42.5 46.5 50.0 52.0 53.0 53.5 56.0 Duct from dwelling [db(a)] 30.5 33.5 45.5 47.0 47.5 49.0 55.5 56.0 57.0 58.0 59.0 Duct to dwelling [db(a)] 41.5 46.5 56.0 58.0 59.5 61.5 65.0 67.5 68.5 69.5 70.5 In practice, the value may deviate 1 db(a) as a result of measuring tolerances Renovent Excellent 400 3

Version Fan graphs 400 375 350 325 300 275 86 Resistance ducts system [Pa] 250 225 200 175 150 125 100 75 50 25 0 Note: The value stated in the circle is the capacity per fan (in Watt) 5 7 12 10 20 17 15 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 26 22 19 32 28 23 Flow rate [m 3 /h] 49 40 36 79 58 51 83 71 Fan graph Renovent Excellent 400 Renovent Excellent 400 4

Version Connections and dimensions Renovent Excellent 300/400 Renovent Excellent right-handed version Renovent Excellent Right-handed 2/2 Renovent Excellent Right-handed 4/0 1 = To dwelling 2 = To atmosphere 3 = From dwelling 4 = From atmosphere 5 = Electric connections 6 = Connection condensate discharge Renovent Excellent Right-handed 3/1 7 = Wall mounting bracket (note the correct position of the rubber strip, washers and caps) Renovent Excellent 400 5

Version Renovent Excellent left-handed version Renovent Excellent left-handed 2/2 Renovent Excellent left-handed 4/0 10 mm 7 Renovent Excellent left-handed 3/1 Mounting wall suspension kit Renovent Excellent 400 6

Service Exploded view When ordering parts, in addition to the article code number (see exploded view), please state the type of the heat recovery appliance, the serial number, the year of production and the name of the part: N. B.: Appliance type, serial number and year of production are stated on the identification plate on the top of the appliance. Example Appliance type : Renovent Excellent 4/0 R Serial number : 420020113201 Year of production : 2013 Part : Fan Article code : 531774 Qty : 1 Service parts Renovent Excellent 400 7

Service Service parts No. Article description Article code 1 Filter kit 2x G3 filter (standard version) 531770 2 Fan Excellent 300 (1 pcs) 532003 Fan Excellent 4300 (1 pcs) 531774 3 Temperature sensor 531775 4 Control panel 531776 5 Heat exchanger Excellent 300 531840 Heat exchanger Excellent 400 531777 6 Motor bypass valve 531778 7 Bypass valve 531779 8 Control board (Plus version) When replacing, note the correct dip switch settings; see 8.1 531780 9 Heating coil 1000 W preheater 531781 10 Cable with power plug 230 volt with display cover* 531782 11 Filter door left 531934 Filter door right 531935 * The mains cable has a print connector. When replacing it, always order a replacement mains cable Brink To avoid dangerous situations, a damaged mains should only be replaced by a qualified person! Renovent Excellent 400 8

Certificates DIBt: Renovent Excellent 400 EN 308/EN 13141-7: Renovent Excellent 400 Declaration of Conformity according to EN 13141-7:2004 / EN308 TNO-060-DTM-2013-01161 Determination of the energetic efficiency of the energy recovery appliance Renovent Excellent 400 Test report in accordance with EN 13141-7:2004 / EN308 Technical Sciences Laan van Westenenk 501 7334 DT Apeldoorn Postbus 342 7300 AH Apeldoorn www.tno.nl T +31 88 866 22 12 F +31 88 866 22 48 infodesk@tno.nl Date May 2013 Author(s) Sponsor H.A.J. Hammink Brink Climate Systems BV R.D. Bügelstraat 3 7951 DA Staphorst Project number 060.01122 Keywords heat recovery efficiency All rights reserved. No part of this publication may be reproduced and/or published by print, photoprint, microfilm or any other means without the previous written consent of TNO. In case this report was drafted on instructions, the rights and obligations of contracting parties are subject to either the General Terms and Conditions for commissions to TNO, or the relevant agreement concluded between the contracting parties. Submitting the report for inspection to parties who have a direct interest is permitted. 2013 TNO NEN 5138: Renovent Excellent 400 Passive House Certificate: Renovent Excellent 400 Certificate Passive House suitable component For cool, temperate climates, valid until 31 December 2013 Category: Manufacturer: Product name: Heat recovery unit Brink Climate Systems B.V. 7951 DA Staphorst, NETHERLANDS Renovent Excellent 400 4/0 (3/1) (Plus) This certificate was awarded based on the following criteria: Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Certified for air flow rates of 77 290 m³/h Thermal comfort Θsupply air 16.5 C at θoutdoor air = -10 C Effective heat recovery ηhr,eff 75% rate Electric power Pel 0.45 Wh/m³ consumption Airtightness Interior and exterior air leakage rates less than 3% of nominal air flow rate Balancing and adjustability Air flow balancing possible: yes Automated air flow balancing: yes Sound insulation Sound pressure level Lp 35 db(a) based on a 4 m² equivalent absorption area not met Here Lp = 51.5 db(a) Unit should be installed so that it is acoustically separated from living areas. Indoor air quality Outdoor air filter F7 Extract air filter G4 Frostprotection Frost protection for the heat exchanger with continuous fresh air supply down to ΘOutdoor air = -15 C 1) 1) Only with additional anti freezing protection ηhr,eff 84% (88% bei 100 m³/h) Electric power consumption 0.29 Wh/m³ Further information can be found in the appendix of this certificate. www.passivehouse.com 0503v03 Renovent Excellent 400 9

Certificates SAP-Appendix-Q: Renovent Excellent 400 Declaration of Conformity Renovent Excellent 400 Renovent Excellent 400 - SEL-waarde 75+100 Pa Toesteltype: Renovent Excellent 400 4/0 R Serienummer: 420020111501 Ventilator: R3G190-RG23-11 (06/11) HW: H1.0 SW: Keuring DIBt-PHI Uitgevoerd door: Rudolf Hanewald Datum: 15-04-2011 1450 Renovent Excellent 400 4/0 R SEL value at 75-100 Pa resistance 1400 1350 75 Pa 100Pa 1300 1250 1200 SEL value [J/(m³] 1150 1100 1050 1000 950 900 850 800 750 700 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 Flow [m³/h] Rapportnummer: 0255 Modifications reserved Brink Climate Systems B. V. continuously strives after improvement of products and reserves the right to change the specifications without prior notice. Renovent Excellent 400 10

BRINK CLIMATE SYSTEMS B.V. P.O. Box 11 7950 AA Staphorst Tel. +31 (0) 522 46 99 44 Fax +31 (0) 522 46 94 00 info@brinkclimatesystems.nl www.brinkclimatesystems.nl