Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

Similar documents
Halo. Thermostatic heads with built-in sensor

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

Thermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise.

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Multilux 4-Eclipse-Set

IMI Heimeier Kit Hydroca ble

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Installation and operating instructions

Thermostatic valves with radiator connection systems

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

E-pro. Time adaptor with E-Pro Stick for thermostatic valves

Thermostatic Actuators

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Control valves for floor heating systems. Floor Heating Manifolds

Flush individual room control for floor heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Data sheet Thermostatic sensors type RA 2000

Mikrotherm. Manual Radiator Valves With presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

Art-Line. Absolutely Brilliant Temperature control was never so good

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Three-way reversing valve

TRV 300 RADIATOR VALVES

Thermostatic valve bodies

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Standard. thermostatic valve body without presetting

thermostatic valve body with stepless precision presetting

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Radiator Valve Program

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

EMO T. Thermal actuator for heating, ventilation, and air conditioning systems. To be precise.

Thermostatic head with wax sensor

Meet Max. Unique AFC technology

Automatic balancing valves ASV-PV (new generation) DN 32-50

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

SOLUTIONS GUIDE. For total efficiency

Thermostatic Radiator Valves (Caleffi)

30 radiators from one central point. Simply smarter heating. living.danfoss.com. living by Danfoss heating control

Valid from

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Thermostatic valve bodies

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

living connect, Electronic Radiator Thermostat

Installation and User Guide eco Intelligent Radiator Thermostat

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Convertible radiator valve for one-pipe systems, centre distance 35 mm

caleffi hydronic valves page 1 of 12

Product overview All you need to know about choosing valves and thermostats

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

RA2000 Thermostatic Radiator Valves

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Product Announcement

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems

Installation and User Guide living connect Electronic Radiator Thermostat

We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

TS RD 7761 RD, 7761 RD

Thermostatic Heads TT3000 TT3000C TT /02/2018. Technical Data Sheet

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

RA2000 Commercial TRVs

PANEL RADIATORS DESIGN RADIATORS TOWEL WARMERS.

STRAIGHT AND ANGLED THERMOSTATIC VALVES

Danfoss Eco Electronic radiator thermostat

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

RA15/6T & TB Conversion Valve

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

T6 - Centrally Connected & VONOPLAN T6.

Catalogue e and d price list

thermostatic inserts for radiators with integrated valves

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

RA 2000 Series RA 15/6T & TB Conversion Valve

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Radiator Trap Radiator Valve

Radical CPD BIM.

Transcription:

Thermostatic head K Thermostatic heads with built-in sensor and remote sensor

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K Thermostatic head K The thermostatic heads K are used to control the temperature of individual rooms using, for example, heaters, convectors, and radiators. The thermostatic head K range not only provides highprecision control it also is designed for exceptional ease of use. The models with remote sensor enables the installation of the thermostatic head covered by curtains, radiator facings, or other obstructions, or mounted vertically or in tight niches. Key features > > Liquid-filled thermostat with high pressure power and precision control > > With 2 clips for marking, limiting or blocking > > Symbols for basic setting and nighttime set back > > Brief data including the most important settings > > Rotation direction indicator > > Markings designed for the visually impaired Technical description Application: Heating systems Functions: Room temperature control. Frost protection. Markings indicate upper and lower temperature range; two energy saving clips can be used to limit settings. Temperature range is limited on both ends and can be blocked using covered stop clips. Control behavior: Proportional controller without auxilliary energy. Liquid-filled thermostat. High pressure power, lowest hysteresis, optimal closing time. Stable control behavior even in the case of small calculated p-band variation (<1K). Nominal temperature range: See each product Temperature: Max. sensor temperature: 50 C (122 F) Specific extension: 0,22 mm/k, Valve stroke limiter Water temperature influence: With built-in sensor: 0.3 K With remote sensor: 0.3 K Differential pressure influence: With built-in sensor: 0.2 K With remote sensor: 0.3 K Closing time: With integral sensor 19 min With remote sensor: Horizontally fitted sensor 12 min Vertically fitted sensor 15 min Hysteresis: With built-in sensor: 0.15 K With remote sensor: 0.2 K Material: ABS, PA6.6GF30, brass, steel, Liquid-filled thermostat. Colour: White RAL 9016 Marking: Heimeier and KEYMARK symbol. Setting numbers. Symbols for basic setting and nighttime reduction. Brief data including the most important settings. Setting indicators on the face of the head and markings designed for the visually impaired. Rotation direction indicator. Standard: KEYMARK certified and tested according to EN 215. See also leaflet Thermostatic Heads - General. 011 Connection: Designed to be mounted on all IMI Heimeier thermostatic valve bodies and radiators with integrated valves which have an M30x1.5 thermostatic insert. 2

Construction e. g. Thermolux K with thermostatic valve body Eclipse with automatic flow limitation 1. Corrugated pipe 2. Markings designed for the visually impaired 3. IMI Heimeier connection technology (locking ring M30 x 1.5) 4. Liquid-filled thermostat with high pressure power and precision control 5. Safety spring 6. Hidden stops for variable limiting and blocking e. g. Thermolux K with thermostatic insert for radiators with integrated valve 7. Thermostatic insert for radiators with integrated valve Function In terms of controls, thermostatic heads are seen as continuous proportional controllers (P controllers) that require no auxilliary energy. They do not need an electrical connection or other source of energy. Changes in room air temperature are proportional to changes in the valve stroke. If the temperature of the air in the room increases due to sunshine, for example, the liquid in the temperature sensor expands and affects the corrugated pipe. This chokes the water supply to the radiator via the valve spindle. If the temperature in the room decreases, the opposite process occurs. The change in valve stroke caused by a change in temperature can be quantified as 0.22 mm per K room temperature change. 3

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K Application IMI Heimeier thermostatic heads are used to control the temperature of individual rooms using, for example, heaters, convectors, and radiators. They are designed to be mounted on all IMI Heimeier thermostatic valve bodies and on radiators with integrated valves which have an M 30 x 1.5 connecting thread on the thermostatic insert. Adapters and models with direct connections enable mounting onto thermostatic valve bodies from other manufacturers. The thermostatic heads use the energy of internal and external heat sources including solar heat, the heat radiated from people and electrical devices, and other sources, in order to keep the room air temperature constant. This helps to avoid wasting energy. Thermostatic heads with built-in sensors may not be covered by curtains, radiator facings, or other obstructions, or mounted vertically or in tight niches. Otherwise it will not be possible to precisely control the temperature. In other cases, it may be necessary to install a remote sensor or remote dial (see leaflet Thermostatic head F). Notes on installation Correct Circulation of air around the thermostatic head is not hindered. Correct The remote sensor enables an unhindered reading of the air temperature in the room. Underfloor convector (Thermostatic head F) Incorrect The thermostatic head with built-in sensor may not be mounted vertically. Incorrect The thermostatic head with built-in sensor may not be covered by curtains. Built-in cabinet (Thermostatic head F) 4

Operation Recommended room temperatures The following temperature settings are recommended for the corresponding rooms based on heating with cost savings in mind: Setting/Position Room temperature approx. Recommended for e.g. INFO 6 C 14 C 20 C 4 C 1 2 3 4 5 Swimming pool* * Bathroom Work room or children s bedroomr Living or dining rooms (basic setting) Kitchen, corridor Hobby room, bedroom All rooms at night (nighttime reduction) Stairway, vestibule Basement/cellar rooms (frost protection setting) *) If higher temperatures are required for the swimming pool area, special thermostatic heads are available (15 C (59 F) to 35 C (95 F) setting range). **) For thermostatic heads with an auxilliary zero position, the lowest setting is 0 C (32 F). Setting the temperature The desired room temperature can be selected by turning the thermostatic head (right = cooler, left = warmer). The arrow must be pointing to the appropriate setting position (number, bar, symbol). All IMI Heimeier thermostatic heads are adjusted in a climatic chamber, free of external influences such as heat build-up, sunshine, etc. The number 3 corresponds to a temperature of approximately 20 C (68 F). The difference between each number is approximately 4 C (7 F), from bar to bar approx. 1 C (2 F). We recommend setting at the number 3 which corresponds to the basic setting of about 20 C (68 F) room temperature. Settings above 4 should be avoided if a lower setting satisfies the comfort level, as a 1 C (2 F) higher room temperature corresponds to an increase in energy use of around 6 %. 5

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K Articles Thermostatic head K with built-in sensor Standard Model Setting range EAN Article No Setting numbers 1 to 5 6 C 28 C 4024052248711 6000-00.500 With two economy clips Setting numbers 1 to 5 Cap with graduation chrome 6 C 28 C 4024052463923 6000-00.501 Cap with graduation RAL 7016, anthracite grey 6 C 28 C 4024052464029 6000-00.503 Cap with graduation RAL 7035, light grey 6 C 28 C 4024052464128 6000-00.504 Cap with graduation RAL 7037, dust grey 6 C 28 C 4024052464227 6000-00.505 Cap with graduation RAL 9005, jet black 6 C 28 C 4024052524020 6000-00.507 Setting scale with temperature values With two economy clips 6 C 28 C 4024052561612 6000-00.600 4 3 2 With zero position (valve opens at approx. 0 C or 32 F) Setting numbers 1 to 5. With two economy clips 0 C 28 C 4024052277117 7000-00.500 Public buildings model Theft protection using security ring. Increased strength in accordance with former German army certification TL 4520-0014 Stress group 1 (for highest stress). With two economy clips. Model Setting range EAN Article No Standard 6 C 28 C 4024052264711 6020-00.500 With zero position (valve opens at approx. 0 C or 32 F) 0 C 28 C 4024052278213 7020-00.500 With theft protection using 2 screws Setting numbers 1 to 5. With two economy clips. Setting range EAN Article No 6 C 28 C 4024052266517 6040-00.500 For public indoor swimming pools, medical spas Setting numbers 1 to 5. With two economy clips. Setting range EAN Article No 15 C 35 C 4024052273515 6200-00.500 Public buildings model. Theft protection using security ring. Staggered/limited setting range. Setting number based on setting range 1-3/1-4/1-5. Turn all the way left for highest setting. Increased strength in accordance with former German army certification TL 4520-0014. Setting range Article No lowest setting 6 C (43 F), upper setting in 1 C (2 F) increments between 15 C (59 F) to 25 C (77 F). *) When ordering indicate upper value, e.g. enter at.. 20 for 20 C (68 F). 6120-...500 * ) 6 *) setting at 3

Articles Thermostatic head K with remote sensor Standard 22 Model Setting range Capillary tube length [m] EAN Article No 81 Standard Setting numbers 1 to 5 With two economy clips. 6 C 27 C 1,25 4024052259816 6001-00.500 2,00 4024052260515 6002-00.500 5,00 4024052262212 6005-00.500 8,00 4024052263011 6008-00.500 10,00 4024052263417 6010-00.500 With zero position (valve opens at approx. 0 C or 32 F) Setting numbers 1 to 5. With two economy clips. 0 C 28 C 2,00 4024052277810 7002-00.500 22 Public buildings model Theft protection using security ring. Setting numbers 1 to 5. With two economy clips. 81 Setting range Capillary tube length [m] EAN Article No 6 C 27 C 2,00 4024052265114 6022-00.500 22 With theft protection using 2 screws Setting numbers 1 to 5. With two economy clips. 81 Setting range Capillary tube length [m] EAN Article No 6 C 27 C 2,00 4024052267217 6042-00.500 7

IMI HEIMEIER / Thermostatic Thermostat-Köpfe Heads und & Radiator Heizkörperventile Valves / / Thermostatic head head K K Accessories Theft protection for thermostatic heads K, DX, D, WK. EAN Article No 4024052264810 6020-01.347 Connecting to products from other manufacturers Adapters for mounting all IMI Heimeier thermostatic heads on thermostatic valve bodies from manufacturers listed here. Standard M 30 x 1.5 threaded connection. Refer also Thermostatic head with direct connection to thermostatic valve bodies from other manufacturers.. Manufacturer EAN Article No *) can not be used on radiators with integrated valves Danfoss RA*) 4024052297016 9702-24.700 *) Danfoss RAV 4024052300112 9800-24.700 Danfoss RAVL 4024052295913 9700-24.700 Vaillant (Ø 30 mm) 4024052296019 9700-27.700 TA (M28x1,5) 4024052336418 9701-28.700 Herz (M28x1,5) 4024052296316 9700-30.700 Markaryd (M28x1,5) 4024052296514 9700-41.700 Comap (M28x1,5) 4024052296712 9700-55.700 Giacomini 4024052429714 9700-33.700 Oventrop (M30x1,0) 4024052428519 9700-10.700 Ista 4024052511419 9700-36.700 Connection to radiators with integrated valves Adapters for mounting IMI Heimeier EAN Article No thermostatic heads with an M 30 x 1.5 Series 2 (20 x 1) 4024052297214 9703-24.700 connection on thermostatic inserts for Series 3 (23,5 x 1,5), 4024052313518 9704-24.700 clamping connections. since 10/98 Standard M 30 x 1.5 threaded connection. Exception: The thermostatic head WK is designed only for mounting on thermostatic inserts with an M 30 x 1.5 threaded connection. Spindle extension for thermostatic valve bodies. L EAN Article No Brass nickel-plated 20 4024052528813 2201-20.700 30 4024052528912 2201-30.700 Plastic, black 15 4024052553310 2001-15.700 30 4024052165018 2002-30.700 Removal device for graduation cap of thermostatic head K and VK and for dismounting stop clips. EAN Article No 4024052457410 6000-00.138 The groove on the face of the thermostatic heads K, VK, WK and F serves to take up color clips or specially printed partner clips. E-mail: Partnerclip.Montage@imi-hydronic.com The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. Thermostatic head K EN ed.3 10.2017