Parts Manual. Counter Type Electric Convection Steamer. Series: SteamCraft Models 21CET East 179 th Street Cleveland, Ohio 44110

Similar documents
Statement of Responsibilities


Parts Manual. Gas Floor Type Convection Steamer. Series: SteamCraft Model 24CGA East 179 th Street Cleveland, Ohio 44110

Parts Manual. Counter Type Gas Convection Steamer. Series: SteamCraft Model 21CGA East 179 th Street Cleveland, Ohio 44110

Statement of Responsibilities

Statement of Responsibilities

Statement of Responsibilities

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

STEAMPRO. Steam Generator Troubleshooting and Service Guide

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor Undercounter AquaTemp HUMIDITY OVENS and CONVECTION OVENS 2000 WATTS

COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS

Part Number DOMESTIC. HyPerSteam Atmospheric Convection Steamer BETA 1.0

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

Wiring Diagrams DIAGRAM INDEX

TSC & TSC-M Proofer/Oven

MODELS SSB-3E/5E/10EF, (2)SSB-3E/5E/10EF, SSB-3G/5G/10GF, (2)SSB-3G/5G/10GF

Please read this manual completely before attempting to install, operate or service this equipment

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Express Price List Popular Models & Accessories. QS QUICKSHIP ITEMS (48 hour) EX EXPRESS ITEMS (10 work day lead time)

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Effective october 14, 2014

MODEL GL-X INSTALLATION & OPERATION

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

L A signature series TA T N E RE O, A L L A T S IN

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Installation Manual. Energy Star SteamChef Models 22CET3.1 and 22CET6.1 PATENT PENDING East 179 th Street Cleveland, Ohio 44110

CROWN SERVICE MANUAL ELECTRIC COUNTERTOP STEAMERS MODELS: PX-3 PX-5

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

MODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Owner s Manual. Keep with machine for reference CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA FAX

MODEL CMA-180UC INSTALLATION & OPERATION Rev 1.17A

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY 12kW QUIKTHERM RETHERM OVEN

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

MODEL L-1X & L-1X16 Installation & Operations

Fast Track Troubleshooting

Effective october 14, 2014

Owner s Manual. Keep with machine for reference PKD24A INSTALLATION & OPERATION. Rev

Cleveland. When You Need a Lot and Need It Fast

Replacement Parts List For Models COS-101 COS-101S

Self-Contained Electric Steam Jacketed Kettle

Owner s Manual MODEL L-1X & L-1X16 Installation & Operations

SERVICE MANUAL C24EO SERIES ELECTRIC COUNTERTOP STEAMERS - NOTICE - C24EO5

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

Heat Pump Defrost Board Replacement Kit

American Dish Service

MODEL L-1X & L-1X16 Installation & Operations

Instruction Manual STR MODEL RESISTO-FLO ELECTRIC BOILER

Owner s Manual MODEL L-1X & L-1X16 Installation & Operations

MODEL GWX-200 INSTALLATION & OPERATION

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

Outdoor Reset IQ Option Card, p/n

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

Outdoor Reset IQ Option Card, p/n

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER

Cleveland Range REPAIR MANUAL

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

CURTIS GOLD CUP BREWER

U155 Series Ice and Beverage Dispensers

Operator s Manual. Energy Star SteamChef Models 22CET3.1 and 22CET6.1 PATENT PENDING

Replacement Parts List For Models COS-20G

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL JTX / JHX TANKLESS BOOSTER HEATER

FLAKER/DCM SEQUENCE OF OPERATION

"ER" Series Electric Humidifier

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

Installation Manual CARBONATOR With Plain-Water Booster

IMPORTANT INFORMATION, READ BEFORE USE. PLEASE SAVE THESE INSTRUCTIONS.

BCX-14 & BX-14 COMBINATION OVEN STEAMER CNVX-14 CONVECTION OVEN REPLACEMENT PARTS LIST

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

USERS INFORMATION MANUAL

Operation Manual NEMA 4X Controls

A B A B4

Cleveland Range Inc. COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT. Cleveland General Specifications. Cleveland Standard Features

HD3D Forced-Air Heater

Champion. Technical Manual. The Dishwashing Machine Specialists. Door-Type Dishwasher. Machine Serial No. February, 2003

GB5MV-10-LD GB6MP-10-LD-U GB8MP-10-LD-U

Two-Position Electric Duplex Room Thermostats

KLE-235D DOUBLE RACK IN-LINE CONFIGURATION KLE-175GTM SINGLE RACK THREE-DOOR CONFIGURATION KLE SERIES ULTRA WASH DISHMACHINE INSTRUCTION MANUAL

B SERIES ELECTRIC FURNACE

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

Hoshizaki America, Inc.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TX / HX TANKLESS WATER HEATER

BC14G SERIES SERIAL NUMBERS WITH IW/IX/IZ/JG/JO REPLACEMENT PARTS LIST. EFFECTIVE March 20, 2006

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

Gate Operator. Modfications

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

Super Runner Series Electric Fryers

RHP120 RHP300 Steam Boiler Series

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Machine Serial No. Technical Manual. International Door Dishwasher. February, 1998 Manual P/N Rev.A

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS

Transcription:

Parts Manual Counter Type Electric Convection Steamer Series: SteamCraft Models 21CET8 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com

CLEVELAND RANGE 21CET8 SEQUENCE OF OPERATIONS Mechanical Timer 1. Supply power is sent to the primary of the main transformer. 115 VAC is sent from the secondary of the main transformer to the on/off rocker, 2. To turn the unit on, depress the red on/off rocker switch. 115 VAC is sent to the red power light. 115 VAC is sent to normally open drain valve closing it. 115 VAC is sent to H and N on the water level board 3. With the water level board energized and no water in the generator 5 seconds later 115 VAC is sent from the FILL terminal to the fill solenoid. The fill solenoid opens and the generator fills through the drain valve. The water fills to the low probe shorting it to ground 115 VAC is sent to the heat standby timer which will energize 3 seconds every 4 minutes to maintain heat while unit is idle 115 VAC is sent from the HEAT terminal to the timed manual switch. 4. When the timed/manual switch is in the timed position and time is on the timer 115 VAC is sent from the timer to the R2 relay coil R2 relay energizes closing the R2A and R2B contacts 115VAC is sent through the now closed R2B contacts to the timer motor 115 VAC is sent through the now closed R2A contacts through the door switch to the normally closed contacts of the high limit switch. 115 VAC is then sent through the high limit to the coil of condensate solenoid The condensate solenoid opens spraying cold water down the compartment drain. 115 VAC is also sent through the high limit to the coil of the contactor. 115 VAC is sent to the clean light timer. When the clean light timer times down 115 VAC is sent to the clean light switch. When the clean light switch is depressed the clean light timer is reset. 5. When the contactor coil is energized supply voltage is sent to both of the elements. The elements are energized and the water is heated to steam. Steam is directed to the cooking compartment. 6. When the timer times out 115 VAC is sent to the 3 second timer and then to the buzzer for 3 seconds. 115 VAC is removed from the R2 relay. R2A contacts open de energizing the heat circuit R22B relay contacts open removing the 115 VAC from the timer motor

7. When the water level reaches the high probe then 115 VAC is removed from the FILL terminal and the fill solenoid is turned off. 8. After the water level drops below the high probe for 5 seconds 115 VAC is sent to the FILL terminal again. 9. The red on/off switch is depressed and the unit is turned off. 115 VAC is removed from the heat and timer circuit. 115 VAC is removed from the normally open drain valve allowing the steamer to drain. 115 VAC is sent to the 3-minute timer and the fill solenoid is energized for 3 minutes flushing the drain.

STEAMCRAFT 3.1 MECHANICAL TIMER (PROBE) CUSTOMER CONNECTION 380/415V L1 3Ø W/ NEUTRAL L2 L3 N FIELD CONVERSION FROM 3Ø TO 1Ø IS NOT PERMITTED DRYING ELEMENT TB FU FU HEATING ELEMENTS CUSTOMER CONNECTION 1Ø L1 L2 1Ø TB FU FU CONTACTOR DRYING ELEMENT CUSTOMER CONNECTION 3Ø L1 L2 L3 3Ø TB RESET CIRCUIT BREAKER CONTACTOR FU FU H4 X1 H1 PRIMARY HEATING ELEMENTS X2 SECONDARY 120V DESCALE TIMER 3 2 4 7 8 1 6 5 L NO A L NO DESCALE INDICATOR & RESET SWITCH 3 2 FILL VALVE POWER SWITCH 1 3 MIN TIMER POWER ON R HEAT FILL H N WATER BOARD XL HI C TO PROBES MANUAL TIMED MANUAL TIMED R2B C NO C NO R2 3 3 SEC TIMER 2 BUZZER MOTOR NC R2A C NO DOOR SWITCH (SCS OPT) 1 R1 ( OPT ) ELECTRO-MECHANICAL TIMER R1 CONTACTOR 1 NO C HI LIMIT SWITCH CONDENSER VALVE 2 3 HEAT STANDBY TIMER ( STACKED UNITS OPTION ) BLOWDOWN OPTION R1 INTERMITTENT C NC BLOWDOWN TIMER 1 2 3 COOLING FAN DRAIN VALVE L106347 M

19 PNK 3 4 C 1 / NC 20 NO 3 2 1 SINGLE PHASE WIRING CONFIGURATION TO FUSE BLOCK L1 L2 L3 TERMINAL BLOCK CUSTOMER CONNECTION 3 2 1 / GRA /GRA LT BLU ORN 23 R2 ORN/ 2 BLU / TAN TAN / /BRN LT BLU LT BLU /BLU 18 21 3 2 4 7 8 BLU REMOVED W / OPT DOOR SWITCH ( SCS ) YEL YEL TAN / BRN DRYING ELEMENT HEATER ELEMENT DRYING ELEMENT 17 5 1 6 5 BRN YEL HEATER ELEMENT 6 22 6 STEAMCRAFT 3.1 MECHANICAL TIMER (PROBE) 16 3 2 1 7 3 2 1 TIMED/MANUAL SWITCH 9 15 INTERMITTENT BLOWDOWN OPTION YEL N ( TO HIGH LIMIT ) TAN BLU 3 2 1 N YEL 8 23 GRN HEAT FILL H TAN / 7 GRN C HI XL N BRN BRN /BRN COND TIMED/MANUAL SWITCH ( THRU SCS ) ( TO COND SOL ) 8 /BLU 14 JUMPER POSITION FOR 480 V OPERATION H4 H2 H3 H1 GRN 10 26 PARTS LIST: 1 19993 - POWER SWITCH 17 108880 - DOOR SW ( MAGNETIC ) 2 104224 - TIMED / MANUAL SW 18 41350 - BUZZER 20478-3 MIN TIMER 19 110198 - MOTORIZED TIMER 3 20 20477-3 SEC TIMER 4 19994 - DESCALE IND RESET SWITCH 21 104234 - CONTACTOR 5 106911 - DESCALE TIMER 22 106541 - INTMT BLOWDOWN TIMER 6 109239 - HEAT STANDBY TIMER 23 105966 - RELAY 24 101540 - END SEGMENT 7 44168 - TERMINAL BLOCK 25 101541 - TERM BLOCK SECTIONAL 8 22221 - DRAIN VALVE 26 20304 - GROUND LUG 9 107211 - COOLING FAN ( OPT ) 27 109380-3.5 AMP, 600V FUSE 10 22218 - WATER SOLENOIDS 28 109374 - FUSE BLOCK 11 12 BLU /BLU FILL 24 X1 X2 208/240 VOLT H4 H2 H3 H1 L1 L2 L3 25 CUSTOMER CONNECTION /BRN BRN 11 103731 - HI LIMIT SWITCH 300022 - CONTACTOR BRN 13 108331 - RESET CIRCUIT BRKR 14 20535 - TRANSFORMER 15 107241 - WATER BOARD 16 107239 - PROBE FU FU 27 28 12 DRYING ELEMENT 13 HEATER ELEMENT HEATER ELEMENT DRYING ELEMENT P106347 M

STEAMCRAFT 3.1 ELECTRONIC TIMER (PROBE) CUSTOMER CONNECTION 380/415V 3Ø W/ NEUTRAL L1 L2 L3 N FIELD CONVERSION FROM 3 TO 1 IS NOT PERMITTED DRYING ELEMENT TB CUSTOMER CONNECTION 1 L1 L2 TB FU FU FU FU CONTACTOR HEATING ELEMENTS DRYING ELEMENT CUSTOMER CONNECTION L1 L2 CONTACTOR 3 L3 TB FU HEATING ELEMENTS RESET CIRCUIT BREAKER FU H4 X1 H1 PRIMARY X2 SECONDARY 120V DESCALE TIMER 3 2 4 7 8 1 6 5 L NO A L NO DESCALE INDICATOR & RESET SWITCH 3 POWER SWITCH 2 1 3 MIN TIMER POWER ON R FILL VALVE COMPARTMENT THERMAL SWITCH TRANSFORMER 24 VAC HEAT WATER BOARD FILL H N XL HI C TO PROBES ELECTRONIC TIMER FU COIL R1 ( OPT ) TIMED DOOR SWITCH ( SCS OPT ) MAGNETIC R1 CONTACTOR MANUAL 1 NO C HI LIMIT SWITCH CONDENSER VALVE HEAT STANDBY TIMER 3 2 ( STACKED UNITS OPTION ) BLOWDOWN OPTION R1 INTERMITTENT C NC BLOWDOWN 1 TIMER COOLING FAN DRAIN VALVE 3 2 L106346 M

PROBLEM: 21CET8 21CET16 21CEA10 Steamer won't steam. Steamer won't steam Is the red light on? Is there supply voltage to the primary of the transformer? Supply power to the steamer. See STEAMER WON'T FILL Is there water in the sight glass? Is there 115 VAC at the secondary of the transformer? Replace the transformer. Replace the wires to the water board. Is there 120 VAC between terminals H and N on the water board? Replace the on/off rocker switch Replace the water board With a jumper between XL and C on the water board, is there 120 VAC between N and Heat? Is there 120 VAC between terminals N and Heat on the water board? Replace the wire from the water board to the long probe. Is there debris on the Long probe? Is there 115 VAC to the common terminal of the timed/manual switch? Replace the wires to the switch. Clean or replace the probe assy. Does the unit steam in Manual mode? Replace the timer. Does the steamer have the optional door switch? Does steamer steam with door switch bypassed? Is there 115 VAC to the high limit? Is there 115 VAC leaving the high limit? Is there 115 VAC to the coil of the contactor? Replace the wires to the high limit. Replace the high limit. Replace the wires to the contactor coil. Adjust or replace the door switch. Is there an amp draw at the element? Replace the element. Wait longer for the steam. Heat from the element will heat the water to steam.

PROBLEM: 21CET8 21CET16 24CEA10 Steamer wont fill Steamer wont fill. Is there supply voltage to the steamer? Supply power to the steamer. Is there water to the steamer? Supply cold water to the steamer. Is there 120 VAC between the H and N on the water board? Replace the on/off rocker switch. Is there 120 VAC between Fill and N on the water board? Remove the wire from the HI terminal on the water board. Is there 120 VAC between Fill and N? Replace the water board Replace wiring to the fill solenoid. Is there 120 VAC across the coil of the fill solenoid? Is there debris on the HI probe in the probe assy? Replace the wire to the Hi probe. Replace the fill solenoid Is water leaving the fill solenoid? Clean the probes or replace the probe assy. Replace wiring to drain valve. Replace the wiring to the intermittent blowdown timer. Does the steamer have the optional intermittent blowdown timer? Is there 120 VAC between terminals 2&3 on the timer? Is there 120 VAC across the coil of the drain valve? Is water draining from the generator? If water is leaving the fill solenoid and not draining from the generator where is it going? check for leaks.. Replace the intermittent blowdown timer. Replace the drain valve.

PROBLEM: 21CET8, 21CET16, 24CEA10 Electronic timer displays "PAUS" and won't count down Timer displays "paus" and won't count down Is steam heating the cooking cabinet above 192 degrees (the set temp of the thermo-switch)? See Steamer won't steam Replace the thermo-switch Does the timer count down when the thermo-switch is bypassed? Replace the electronic timer PROBLEM: 21CET8, 21CET16, 24CEA10 Steam leaks around the door. Steam leaks around the door Is COLD water supplied to both water lines to the steamer? Supply cold water(35-60 psi) to the steamer. Is the door gasket physically damaged? Is the door out of alignment? Is the drain obstructed? Is there 120 VAC across the coil of the condensate solenoid? Replace the wiring to the condensate solenoid. Turn over the gasket or replace it. Replace the door bearings and pins. Remove the obstruction Is the solenoid opening? Replace the condensate solenoid. Replace the condensate spray nozzle

PROBLEM: 21CET8 21CET16 24CEA10 Steamer overfills. (Water sprays into cooking cabinet) Steamer overfills (Water sprays into the cooking cabinet) Start There is an obstruction in the drain. Remove the obstruction. Does the rise in the water level in the sight glass stop when the cooking cabinet door is opened? Does the water rise in the sight glass when steam is generated and 0 VAC to the fill solenoid? Does the water level in the sight glass stop at the HI (short) probe on the initial fill? There is an obstruction in the generator causing it to pressurize. Delime the steam generator thoroughly. Replace the fill solenoid There is an obstruction in the plumbing to and from the sight glass. Remove the debris (delime thoroughly). Does water spray in the cabinet before the water reaches the HI (short) probe? Replace the three minute timer. Remove the wire from the Fill terminal on the water board. Is there 120 VAC across the coil of the fill solenoid? Is there 120 VAC across the coil of ;the fill solenoid when the HI (short) probe is submerged? Replace the water level board. With HI and C terminals on the water board jumped, Is there 120 VAC between terminals N and Fill? Replace the fill solenoid Clean or replace the probe assembly. Is there debris on the HI (short) probe? Replace the wire to the probe assembly

Steamer won't stop steaming Is the timed/manual switch in the timed position with no time on the timer? Steamer will steam constantly in the manual position. Put the timed/manual switch in the timed position with no time on the timer. PROBLEM: 21CET8 21CET16 24CEA10 Steamer won't stop steaming with door open Does the steamer have the optional door switch? Adjust or replace the door switch. Does steamer continue to steam with both wires removed from terminal 1 on the heat standby timer? Replace the heat standby timer. Is there 120 VAC to the coil of the contacter? Replace the timer. Is there an amp draw at the element? Replace the contactor When supply voltage is removed from the element steam is still made for approximately 10 seconds. This is normal. Problem: 21CET8, 24CEA10 Steamer won't preheat Steamer won't preheat Is the timed/manual switch in the timed postion with time on it or in the manual postion? This steamer is not equiped with a preheat thermostat. The timed manual switch must be in manual or time must be on the timer. See Problem: steamer won't steam.

Problem: 21CET16 Steamer won't preheat Steamer won't preheat Does the steamer have a preheat thermostat Is the timed/manual switch in the timed postion with time on it or in the manual postion? This steamer is not equiped with a preheat thermostat. The timed manual switch must be in manual or time must be on the timer. Is there continuity on the normally closed contacts of the preheat thermostat? See Problem: steamer won't steam. Replace the preheat thermostat

STEAMCRAFT 3.1 MECHANICAL TIMER ( FLOAT ) CUSTOMER CONNECTION 380/415V 3Ø W/ NEUTRAL L1 L2 L3 N FIELD CONVERSION FROM 3 TO 1Ø IS NOT PERMITTED DRYING ELEMENT TB FU FU HEATING ELEMENTS CUSTOMER CONNECTION 1Ø L1 L2 1Ø TB FU FU CONTACTOR DRYING ELEMENT CUSTOMER CONNECTION 3Ø L1 L2 L3 3Ø TB RESET CIRCUIT BREAKER CONTACTOR FU FU H4 X1 H1 PRIMARY HEATING ELEMENTS X2 SECONDARY 120V DESCALE TIMER 3 2 4 1 6 78 5 L NO A L NO DESCALE INDICATOR & RESET SWITCH 3 2 FILL VALVE POWER SWITCH 1 3 MIN TIMER POWER ON R NO R1 C R1 WATER LEVEL TIMED MANUAL TIMED R3B C NO C NO R3 3 3 SEC TIMER 2 BUZZER MOTOR NC R3A C NO DOOR SWITCH (SCS OPT) 1 COIL R2 ( OPT ) ELECTRO-MECHANICAL TIMER R2 CONTACTOR 1 3 NO 2 C LOW WATER CUT-OFF HI LIMIT SWITCH CONDENSER VALVE HEAT STANDBY TIMER ( STACKED UNITS OPTION ) BLOWDOWN OPTION R2 INTERMITTENT C NC BLOWDOWN TIMER 1 3 2 COOLING FAN DRAIN VALVE L300163 D

19 PNK /GRA 3 4 3 2 1 TERMINAL BLOCK CUSTOMER CONNECTION / GRA /GRA BLU BLU / TAN TAN YEL TAN BLU 17 REMOVED W / OPT DOOR SWITCH ( SCS ) YEL SINGLE PHASE WIRING CONFIGURATION TO FUSE BLOCK L1 C / NC 3 20 2 1 NO L2 / 1 2 L3 LT BLU ORN 23 R3 ORN/ /BRN / LT BLU LT BLU /BLU 18 21 3 2 4 7 8 BRN 5 1 6 5 BRN DRYING ELEMENT HEATER ELEMENT DRYING ELEMENT HEATER ELEMENT YEL 6 3 2 1 6 STEAMCRAFT 3.1 MECHANICAL TIMER ( FLOAT ) 3 2 1 /GRA BLU 7 N BLU 9 GRN 23 15 BLU / BRN /BRN INTERMITTENT BLOWDOWN OPTION YEL N 8 7 ( TO HIGH LIMIT ) 22 3 2 1 R1 23 R2 BRN COND BLU TO TIMED/MANUAL SWITCH ( THRU SCS ) ( TO COND SOL ) GRN BLU /GRA RINSE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 8 15 16 10 /BLU 26 BLU BLU /BLU FILL 14 24 X1 208/240 VOLT H4 H2 H3 H1 L1 L2 CUSTOMER CONNECTION /BRN BRN 11 19993 - POWER SWITCH 104224 - TIMED / MANUAL SW 20478-3 MIN TIMER X2 19994 - DESCALE IND RESET SWITCH 106911 - DESCALE TIMER 109239 - HEAT STANDBY TIMER 44168 - TERMINAL BLOCK L3 BRN 22221 - DRAIN VALVE 107211 - COOLING FAN ( OPT ) 22218 - WATER SOLENOIDS 103731 - HI LIMIT SWITCH 300022 - CONTACTOR 108331 - RESET CIRCUIT BRKR 20535 - TRANSFORMER 103726 - FLOAT - - 25 PARTS LIST: FU 17 18 19 FU 27 28 JUMPER POSITION FOR 480 V OPERATION H4 H2 H3 H1 12 HEATER ELEMENT DRYING ELEMENT HEATER ELEMENT DRYING ELEMENT 108880 - DOOR SW ( MAGNETIC ) 41350 - BUZZER 110198 - MOTORIZED TIMER 20 20477-3 SEC TIMER 21 104234 - CONTACTOR 22 106541 - INTMT BLOWDOWN TIMER 23 105966 - RELAY 24 101540 - END SEGMENT 25 101541 - TERM BLOCK SECTIONAL 26 20304 - GROUND LUG 27 28 109374 - FUSE BLOCK 109380 - FUSE 3.5A 600V P300163 D

Descaling Procedure-SteamCraft Ultra and Gemini Series How Much DISSOLVE to Use Model Dissolve Ultra 3 1/2 Gallon Ultra 5 1 Gallon Ultra 10 (Elec.) 1 Gallon (ea.) Ultra 10 (Gas) 1½ Gallon Gemini 6 & 10 1 Gallon (ea.) 6. Let the descaler soak in generator for approximately one hour: 7. After one hour, turn the unit power Off: This will drain and rinse the generator for about 3 minutes. 1. Turn the unit OFF and open the doors: This will drain and rinse the generator for about 3 minutes. 2. Turn the unit power back On: The generator will begin to refill with water. 3. Select Timed with the Timed/Manual switch: DO NOT start the timer, since you do not want to heat the water during descaling. Leave the doors open. 4. Remove descaling port cap and add with the specified amount of DISSLOVE: (See chart above) Do this while the unit is refilling. The generators can take-up to 8 minutes to refill. 5. After refill has stopped, add extra tap water into the descaling port until liquid is seen entering the cooking cabinet. te: Ultra 10 gas will have liquid coming out of the drain, Adding extra water when descaling will raise the descaling solution higher than the normal fill level, allowing the DISSOLVE to work on sensors and surfaces above the water line te: Some SteamCraft Ultra models (the electric powered Ultra 10 and Gemini 6 and 10, for example) have two generators and two descaling ports. Both units should be descaled at the same time, using this procedure 8. After the 3-minute drain cycle completes, turn the unit back ON. After the filling has stopped, add water until liquid enters the cooking compartment (or drain for the ultra 10 gas), and then turn the unit OFF. This will drain and flush any residue from the water level control assembly. Replace descaling cap. 9. After the 3 minute drain cycle completes, Turn the unit ON and set the Timer for 20 minutes: Make sure the Time/Manual switch is in the timed setting and the doors are closed. 10. When the timer times out (after 20 minutes) turn the power Off: This will drain and rinse the generator for about 3 minutes. This ends the descaling procedure. You can now turn the unit back on and resume normal startup and cooking operations.