Price list for production of Design Bureau "Fizelektronpribor"

Similar documents
1943P01. Solar Impact Sensor. Sensor for acquiring the impact of solar radiation Output signal DC V 2-wire current output 4...

сайт: эл. почта: Use RAB11 RAB11.. For 2-pipe fan coils

AUTRONICA. Панели для систем голосового оповещения

сайт: эл. почта: Use RAB21 RAB21.. For two-pipe fan coils

Indoor Air Quality Controller

MANUAL Overflow sensor NVF-104/34-PF

Kolmeks. Каталог. Аксессуары. По вопросам продаж и поддержки обращайтесь:

user manual Non-invasive Ultrasonic Flow Monitor KATflow 10 M E

Панели. Autroprime. Технические характеристики

Панели. AutroSafe 4. Технические характеристики

etron M100

Installation Handbook Autroprime Interactive Fire Detection System

PRODUCT CATALOGUE. Autronica Fire and Security AS Petrochemical, Oil & Gas.

MICROSENSE FLOW SWITCH

Microwave Doppler Flow Switch. Installation & Operation Manual

Sintrol Snifter A2 EX. Manual. Version 1.2.3

MSMCR. Counter-Rotating Blenders. I Application. I Principle of operation

ProSens Dust Measurement

Technology for life. Unit heater LH

Steam sterilizer AHS-75-DRY

Document Code: 1 (6) Issuing date: Status:

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

More Precision. indusensor // Linear inductive displacement sensors

Snifter. User Manual. Distributor

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.

More Precision. indusensor // Linear inductive displacement sensors

Dusty / Dusty Ex Low-Cost Broken Bag Detection

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

TDS Conductivity Probe In-Line conductivity measurement

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

MJC Mini. Cartridge Filter. Features. Principal specification and options

Lightweight Concrete Mix Profitable Using Heavyweight Batch Mixer

NewlyDesignedfor MaximumPerformance

2How does a vibratory fluid-bed dryer work?

industrial electronics electronic level measurement system

DUST SUPPRESSION HOPPER TARDIS MODEL OVERVIEW

CAPACITIVE SENSORS. Reliable detection of objects and fi ll levels.

PRODUCT CATALOGUE V1.3

PRODUCT CATALOGUE V1.5

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

SOILS SPEEDY 2000 MOISTURE TESTER MICROWAVE MOISTURE METER PERMEAMETER MODELS MODELS DESCRIPTION STANDARDS

E340 BOILER CONTROL INSTALLATION MANUAL

Snifter ATEX22 VERSION. User Manual. Distributor

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Radiation-based measurement Detectors

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

WOLF VENTILATION SYSTEM PRICE LIST

CEM Mars 5 Microwave Accelerated Reaction System

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Solid biofuel solutions

Instruction Manual. B Issue B. next Pump Accessories

(Container with bottom unload) AV high vacuum. Description. COMPACT 30 kw. COMPACT 37 kw. COMPACT 37 kw high vacuum. COMPACT 45 kw high vacuum

Sintrol Snifter A1+ Manual. Version 1.2.2

Specially Designed Waste Water & Sewage Pumps

QAQC LABS ANALYTICAL DRYING

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

We have our range of Bath fittings which completes the lifestyle offering to millions of customers across India. The Elegance quality and style in

Systems for central heating

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

From simple point level controls to advanced computer-based inventory management

Biomass Drum Dryer LMK 2000 Model

Yarway Narvik Steam Desuperheater Series 4300 TempLow

SOLIDS FLOW SENSOR SOLIDS FLOW SENSOR: MWS-DP-2

M-Sens 2 Application overview. FlowJam application overview. Online moisture measurement for solids. For measuring capillary and surface humidity

Introduction to Bulk Solids. The Basics

MCL-BIO. Fuels. Main features. multifuel biomass boiler. group of companies

HEATERS & SENSORS INC. - CATALOG

BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance

Settlement Agreement. Schedule 1: Covered Products

Hydrazine Analyzer Series 2171 Specifications

ENTROPIE boiler TT300

Weight / 003 -Z M5 (SUCOFEED ¼ HF) bulk 10 pcs g / 5.25 oz.

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

EXPANSION JOINT PRODUCTS

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

SCC 201E Valid as of E21SE0404 up to E21SE... SCC 201E

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

Fill Point, Level Gauges, and Control Range

ANNEXURE-A SPECIFICATIONS FOR HOT MIX PLANT

PIPING SYSTEM EQUIPMENTS

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Level gauges Series LS Level indicator, switch and transmitter for liquids

Industrial Fire Detection

SDM SERIES - SLURRY DENSITY METER PRODUCT INFORMATION CONTINUOUS IN-LINE MONITORING & PROCESS CONTROL

Energy-efficient heat source provides comfort in large rooms

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

KEE & SEE URAS VIBRATORS

heatersteam unprecedented precision and reliability

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

providing the perfect mix

BIOMASS COMBUSTION BOILERS

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

ADVANCED Series 15P1 17P2 19P2

OWNER S MANUAL LOW-POWER SCREW-IN AND FLANGE-MOUNTED IMMERSION HEATERS (MAXIMUM 3 PINS)

Forward-looking and energy effi cient Biomass heating

Heated Gas Sampling Probe PSG Basic

Transcription:

Архангельск (8182)63-90-72 Астана +7(7172)727-132 Астрахань (8512)99-46-04 Барнаул (3852)73-04-60 Белгород (4722)40-23-64 Брянск (4832)59-03-52 Владивосток (423)249-28-31 Волгоград (844)278-03-48 Вологда (8172)26-41-59 Воронеж (473)204-51-73 Екатеринбург (343)384-55-89 Иваново (4932)77-34-06 Ижевск (3412)26-03-58 Казань (843)206-01-48 Калининград (4012)72-03-81 Калуга (4842)92-23-67 Кемерово (3842)65-04-62 Киров (8332)68-02-04 Краснодар (861)203-40-90 Красноярск (391)204-63-61 Курск (4712)77-13-04 Липецк (4742)52-20-81 Магнитогорск (3519)55-03-13 Москва (495)268-04-70 Мурманск (8152)59-64-93 Набережные Челны (8552)20-53-41 Нижний Новгород (831)429-08-12 Новокузнецк (3843)20-46-81 Новосибирск (383)227-86-73 Омск (3812)21-46-40 Орел (4862)44-53-42 Оренбург (3532)37-68-04 Пенза (8412)22-31-16 Пермь (342)205-81-47 Ростов-на-Дону (863)308-18-15 Рязань (4912)46-61-64 Самара (846)206-03-16 Санкт-Петербург (812)309-46-40 Саратов (845)249-38-78 Севастополь (8692)22-31-93 Симферополь (3652)67-13-56 Смоленск (4812)29-41-54 Сочи (862)225-72-31 Ставрополь (8652)20-65-13 Сургут (3462)77-98-35 Тверь (4822)63-31-35 Томск (3822)98-41-53 Тула (4872)74-02-29 Тюмень (3452)66-21-18 Ульяновск (8422)24-23-59 Уфа (347)229-48-12 Хабаровск (4212)92-98-04 Челябинск (351)202-03-61 Череповец (8202)49-02-64 Ярославль (4852)69-52-93 Price list for production of Design Bureau "Fizelektronpribor" E-mail: fzp@nt-rt.ru Cite: http://fizepr.nt-rt.ru 30.05.2017 Prices are in Russian rubles. Ruble exchange rate as of May 30, 2017 is: RUB 56.7106 per 1 US Dollar Ite m No. Description, design version Application, materials controlled Sensor design Price, RUB General purpose industrial version Explosionproof version 1 Bulk material moisture analyzers (moisture meters) 1 Moisture analyzer -10.41 2 Moisture analyzer -10.43 3 Moisture analyzer -10.4 4 Moisture analyzer -10.42 5 Moisture analyzer -10.5 Powdered, granular, bulk materials in a hopper, pipe or collecting duct above the conveyor belt (including sawdust and wood chips, wafers, grain, etc.) Bulk materials (wood chip waste, sawdust, pulp, etc.) in a screw or pipe Probe made as a straight rod (diameter 14 mm, length 0.6 m, stainless steel AISI 321) with a set of coupling holders 130,272 Probe made a radially bent rod (diameter 14 mm, stainless steel AISI 321) with a set of coupling holders 149,860 Bulk materials (sand, crushed stone, gravel, ore, grain, etc.) in a hopper, dispenser, including materials that adhere on a probe and walls Ore and other bulk materials on a belt conveyor. Sensor feature: the probe is removable to enable its replacement during the operation. Crushed stone, ore, etc. on a conveyor belt Probe made as a straight rod (cross section 27 mm, length up to 1.0 m, stainless steel AISI 321) with a set of coupling holders 138,296 Probe made as a straight rod (cross section 27 mm, length up to 1.0 m, material - corrosion-resistant steels AISI 321, AISI 420, etc.). 149,860 Plate probe specially shaped with a 14 mm thickness, mounted lengthwise the material flow above a conveyor belt 138,296 184,316

6 Moisture analyzer -10.6 Powdered, granular, bulk materials in a hopper or in-line on a conveyor belt (silicate mixture, sand, crushed stone, grain, etc.) Made as a panel with couplings and flat-topped probe 130,272 176,292 7 Moisture analyzer -10.16 8 Moisture analyzer -11.3 9 Moisture analyzer -11.4 Powdered, granular, bulk materials in a hopper or in-line on a conveyor belt (coal, iron ore and other bulk materials featuring high conductivity) Powdered, granular and bulk materials in a hopper, mixer, silo and on a conveyor belt Liquid and bulk materials as well as for soil moisture control Made as a panel with couplings and flat-topped probe 194,700 240,720 Sensor with a two-pinned probe. To be permanently installed on a 1" pipe, can also be fixed directly to a hopper wall or a panel installed along a conveyor belt Sensor with a two-pinned probe. Probe is equipped with a tip to immerse the sensor in a dense controlled material, e.g. soil 139 712 135'169 2 10 Moisture analyzer.70 VIGT.415210.700 (-17) 11 Moisture analyzer.71 VIGT.415210.710 (-171) 12 Moisture analyzer.72 VIGT.415210.720 (-172) Moisture analyzers (moisture meters) for concrete mixture, iron-ore concentrate and other bulk and paste-like materials Control of water content in concrete mixture inside concrete mixing machines, control of material moisture inside hoppers Control of water content in concrete mixture inside concrete mixing machines, control of material moisture inside hoppers Measurements of bulk, paste-like materials in cylindrical sampling systems Sensor of 108 mm diameter (supplied with a fixing set) 149,860 195,880 Sensor of 80 mm diameter (supplied with a fixing set) 146,320 192,340 Sensor of 80 mm diameter (supplied with a fixing set) 149,860 195,880 In-line moisture analyzers (moisture meters) for liquid materials 13 Moisture analyzer -20.4 pressure up to 10 bar. Straight-flow sensor made as a DN50 PN10 pipe section; ver. 1-50-10 GOST 12820-80; 219,418 265,438

14 Moisture analyzer -20.5 pressure up to 25 bar. Straight-flow sensor made as a DN50 PN25 pipe section; ver. 1-50-25 GOST 12820-80; 226,560 272,580 15 Moisture analyzer -20.51 16 Moisture analyzer -20.6 pressure up to 25 bar. -20 +145 С. pressure up to 16 bar. Straight-flow sensor made as a DN50 PN25 pipe section; ver. 1-50-25 GOST 12820-80; Straight-flow sensor made as a DN80 PN16 pipe section; ver. 1-80-16 GOST 12820-80; 260,544 306,564 230,100 276,120 3 17 Moisture analyzer -20.61 18 Moisture analyzer -20.7 pressure up to 16 bar. -20 +145 С. pressure up to 25 bar. Straight-flow sensor made as a DN80 PN16 pipe section; ver. 1-80-16 GOST 12820-80; 264,084 310,104 Straight-flow sensor made as a DN80 PN25 pipe section; ver. 1-80-25 GOST 12820-80; 233,640 279,660 19 Moisture analyzer -20.71 pressure up to 25 bar. -20 +145 С. Straight-flow sensor made as a DN80 PN25 pipe section; ver. 1-80-25 GOST 12820-80; 267,624 313,644 20 Moisture analyzer -20.8 Straight-flow sensor made as a DN50 PN40 pipe section; weld neck ver. 2-50-40 and ver. 3-50- 40 GOST 12821-80; complete with AISI 1020 steel mating 244,496 290,516 21 Moisture analyzer -20.9 Straight-flow sensor made as a DN80 PN40 pipe section; weld neck ver. 2-80-40 and ver. 3-80- 40 GOST 12821-80; complete with AISI 1020 steel mating 253,700 299,720

22 Moisture analyzer -20.10 Liquid materials in a DN125 pipeline, pressure up to 6 bar. Straight-flow sensor made as a DN125 PN6 pipe section; ver. 1-125-6 GOST 12820-80 () 253,700 299,720 23 Moisture analyzer -20.11 24 Moisture analyzer -20.12 Straight-flow sensor made as a DN50 PN63 pipe section; weld neck ver. 2-50-63 and ver. 3-50- 63 GOST 12821-80; complete with AISI 1020 steel mating Straight-flow sensor made as a DN80 PN63 pipe section; weld neck ver. 2-80-63 and ver. 3-80- 63 GOST 12821-80; complete with AISI 1020 steel mating 262,550 308,570 4 277,890 323,910 25 Moisture analyzer -20.14 26 Moisture analyzer -20.15 pressure up to 6 bar. pressure up to 100 bar. Straight-flow sensor made as a DN100 PN6 pipe section; ver. 1-100-6 GOST 12820-80; 244,496 290,516 Straight-flow sensor made as a DN80 PN100 pipe section; weld neck ver. 2-80-100 and ver. 3-80-100 GOST 12821-80; complete with AISI 1020 steel mating 318,010 364,030 27 Moisture analyzer -20.16 28 Moisture analyzer -20.17 29 Moisture analyzer -20.18 pressure up to 16 bar. pressure up to 25 bar. pressure up to 160 bar. Straight-flow sensor made as a DN100 PN16 pipe section; ver. 1-100-16 GOST 12820-80; 262,550 308,570 Straight-flow sensor made as a DN100 PN25 pipe section; ver. 1-100-25 GOST 12820-80; 268,450 314,470 Straight-flow sensor made as a DN50 PN160 pipe section; weld neck ver. 2-50-160 and ver. 3-50-160 GOST 12821-80; complete with AISI 1020 steel mating 364,030 410,050

30 Moisture analyzer -20.65 Liquid materials in a DN65 pipeline, pressure up to 160 bar. Straight-flow sensor made as a DN65 PN160 pipe section; weld neck ver. 7-65-160 GOST 407,100 453,120 31 Moisture analyzer -20.19 32 Moisture analyzer -20.20 33 Moisture analyzer -20.21 Liquid materials in a DN150 pipeline, pressure up to 10 bar. Straight-flow sensor made as a DN150 PN10 pipe section; ver. 1-150-10 GOST 12820-80; 277,890 323,910 5 Straight-flow sensor made as a DN100 PN40 pipe section; weld neck ver. 2-100-40 and ver. 3-100-40 GOST 12821-80; complete with AISI 1020 steel mating Straight-flow sensor made as a DN100 PN63 pipe section; weld neck ver. 2-100-63 and ver. 3-100-63 GOST 12821-80; complete with AISI 1020 steel mating 354,000 400,020 365,800 411,820 34 Moisture analyzer -20.22 35 Moisture analyzer -21.01 pressure up to 100 bar. Liquid materials in a pipeline with a diameter of 150 mm or more, pressure up to 6.0 bar. Straight-flow sensor made as a DN100 PN100 pipe section; weld neck ver. 2-100-100 and ver. 3-100-100 GOST 12821-80; complete with AISI 1020 steel mating Full-flow sensor contains a probe mounted on a flange ver. 1-100-6 GOST 12820-80. The sensor is installed using a flanged nozzle welded to the pipeline wall. 394,000 440,020 204,140 250,160 36 Moisture analyzer -21.02 Liquid materials in a pipeline with a diameter of 150 mm or more, pressure up to 16 bar. Full-flow sensor contains a probe mounted on a flange ver. 1-100-16 GOST 12820-80. The sensor is installed using a flanged nozzle welded to the pipeline wall. 204,140 250,160 37 Moisture analyzer -21.03 Liquid materials in a pipeline with a diameter of 150 mm or more, pressure up to 40 bar. Full-flow sensor contains a probe mounted on a flange ver. 2-100-40 GOST 12821-80. The sensor is installed using a nozzle (with a mating flange ver. 3-100-40) welded to the pipeline wall. 233,758 279,778

38 Moisture analyzer -21.04 Liquid materials in a pipeline with a diameter of 150 mm or more, pressure up to 63 bar. Full-flow sensor contains a probe mounted on a flange ver. 2-100-63 GOST 12821-80. The sensor is installed using a nozzle (with a mating flange ver. 3-100-63) welded to the pipeline wall. 247,800 293,820 39 Moisture analyzer -21.05 Liquid materials in a pipeline with a diameter of 150 mm or more, pressure up to 100 bar. Full-flow sensor contains a probe mounted on a flange ver. 2-100-100 GOST 12821-80. The sensor is installed using a nozzle (with a mating flange ver. 3-100-100) welded to the pipeline wall. 318,010 364,030 6 40 Moisture analyzer -22.6 41 Moisture analyzer -22.8 pressure up to 16 bar. Sensor made as a DN80 PN16 U-pipe section (bypass); ver. 1-80-16 GOST 12820-80; 271,400 317,420 Sensor made as a DN50 PN40 U-pipe section (bypass); weld neck ver. 2-50-40 GOST 295,000 341,020 42 Moisture analyzer -22.9 Sensor made as a DN80 PN40 U-pipe section (bypass); weld neck ver. 2-80-40 GOST 302,800 348,820 43 Moisture analyzer -22.11 Sensor made as a DN50 PN63 U-pipe section (bypass); weld neck ver. 2-50-63 GOST 313,054 359,074 44 Moisture analyzer -22.12 45 Moisture analyzer -24.8 Sensor made as a DN80 PN63 U-pipe section (bypass); weld neck ver. 2-80-63 GOST Sensor made as a DN50 PN40 L-pipe section (angle); weld neck ver. 2-50-40 GOST 12821-80; 328,394 374,414 295,000 341,020

46 Moisture analyzer -24.9 Sensor made as a DN80 PN40 L-pipe section (angle); weld neck ver. 2-80-40 GOST 12821-80; 302,800 348,820 47 Moisture analyzer -24.11 48 Moisture analyzer -24.12 Sensor made as a DN50 PN63 L-pipe section (angle); weld neck ver. 2-50-63 GOST 12821-80; Sensor made as a DN80 PN63 L-pipe section (angle); weld neck ver. 2-80-63 GOST 12821-80; 313,054 359,074 328,394 374,414 7 49 Moisture analyzer -24.20 Sensor made as a DN100 PN40 L-pipe section (angle); weld neck ver. 2-100-40 GOST 403,100 449,120 50 Moisture analyzer -24.21 Sensor made as a DN100 PN63 L-pipe section (angle); weld neck ver. 2-100-63 GOST 416,304 462,324 51 Moisture analyzer -25.8 Sensor made as a DN50 PN40 Z-pipe section; weld neck ver. 2-50-40 GOST 12821-80; complete with AISI 1020 steel mating 295,000 341,020 52 Moisture analyzer -25.9 Sensor made as a DN80 PN40 Z-pipe section; weld neck ver. 2-80-40 GOST 12821-80; complete with AISI 1020 steel mating 302,800 348,820 53 Moisture analyzer -25.11 Sensor made as a DN50 PN63 Z-pipe section; weld neck ver. 2-50-63 GOST 12821-80; complete with AISI 1020 steel mating 313,054 359,074

54 Moisture analyzer -25.12 55 Moisture analyzer -25.18 56 Moisture analyzer -25.20 57 Moisture analyzer -25.21 pressure up to 160 bar. Sensor made as a DN80 PN63 Z-pipe section (angle); weld neck ver. 2-80-63 GOST 12821-80; 328,394 374,414 Sensor made as a DN50 PN160 Z-pipe section; weld neck ver. 7-50-160 GOST 12821-80; Sensor made as a DN100 PN40 Z-pipe section; weld neck ver. 2-100-40 GOST 12821-80; 407,100 453,120 403,100 449,120 8 Sensor made as a DN100 PN63 Z-pipe section; weld neck ver. 2-100-63 GOST 12821-80; 416,304 462,324 Additional option for analyzer versions -20, -21, -22, -24 and -25: probe design with an extended range of working medium temperatures up to +145 С Additional option for analyzer versions -20, -21, -22, -24 and -25: probe design with an extended range of working medium temperatures up to +300 С +33,984 +33,984 +135,110 +135,110 58 Moisture analyzer -12 59 Moisture analyzer -14 Liquid materials in tanks, including diesel oil emulsion, sludge, etc. -20 +90 С. Water and sand pulp and other liquid, paste-like materials in a pipeline with a diameter of 200-800 mm, working pressure up to 6.0 bar. Probe sensor contains a center pin and 4 perimeterwise pins, installed inside a tank and fixed to a 1" or 2" pipe 148,326 194,346 In-line probe sensor with one pin installed along the pipeline diameter. Attachment - to a nozzle (with a mating flange) welded to a pipeline. 193,520 60 Moisture analyzer -23.01 Steam-water environment, liquid materials in a DN50 pipeline, pressure up to 160 bar. 0 +320 С. Straight-flow sensor made as a DN50 PN160 pipe section; weld neck ver. 2-50-160 and ver. 3-50-160 GOST 12821-80; complete with AISI 321 stainless steel mating 380,550

Laboratory moisture analyzers (moisture meters) 61 Moisture analyzer -30.1 Laboratory measurements mostly of liquid materials and measurements in tanks at different depths. Sensor is equipped with a coupling for mounting on the rod with 3/4" male thread. Sensor contains a 46 mm diameter probe to make measurements in a standard 500 ml measuring cylinder (included in the scope of supply). Volume of controlled sample 450 ml. 130,272 62 Moisture analyzer -30.11 Laboratory measurements mostly of liquid materials and measurements in tanks at different depths. Sensor is equipped with a coupling for mounting on the rod with 1" male thread. Sensor contains a 46 mm diameter probe to make measurements in a standard 500 ml measuring cylinder (included in the scope of supply). Volume of controlled sample 450 ml. 130,272 9 63 Moisture analyzer -30.2 64 Moisture analyzer -30.3 Laboratory measurements of bulk materials mostly (can also be used for control of liquid materials). Laboratory measurements of liquid materials Sensor contains a rectangular measuring cell (220 x 100 x 100 mm) with a probe. Volume of controlled sample 1.8 l. Sensor contains a 17 mm diameter probe with a length of 190 mm for P1-21-200 or P2-21-200 test tubes. Volume of controlled sample 15 ml. 130,272 130,272 Microwave barrier level measurement 65 Microvawe barrier for level SIUR-03V2.2 VIGT.407629.022 Non-contact point level detection in solids with free space radar sensors. Control of burning fuel level in wood waste boilers Allowable temperature of alarm unit housings: -25 +85 С. Non-contact point level detection in solids with free space radar sensors. Control of filling level limit of silos, hoppers with bulk materials Allowable temperature of alarm unit housings: -25 +85 С. Alarm consists of two units installed on the opposite boiler walls using the mounting plates (included in the scope of supply) 35,400 66 Microvawe barrier for level SIUR-03V2.3 VIGT.407629.023 Alarm consists of two units installed on the opposite silo walls and mounted with 1 sleeves welded on to walls (sleeves can be included in the scope of supply as options on request). Electronic units are connected using sealed 2RMG-type connectors. 35,400

67 Microvawe barrier for level SIUR-03V2.4 VIGT.407629.024 68 Microvawe barrier for level SIUR-03V2.41 VIGT.407629.024-01 Non-contact point level detection in solids with free space radar sensors. Control of filling level limit of silos, hoppers with bulk materials Allowable temperature of alarm unit housings: -25 +85 С. Non-contact point level detection in solids with free space radar sensors. Control of filling level limit of silos, hoppers with bulk materials Allowable temperature of alarm unit housings: -45 +85 С. Alarm consists of two units installed on the opposite silo walls and mounted with 1 sleeves welded on to walls (sleeves can be included in the scope of supply as options on request). Electronic units are connected using sealed cable leadins. Alarm consists of two units installed on the opposite silo walls and mounted with 1 sleeves welded on to walls (sleeves can be included in the scope of supply as options on request). Electronic units are connected using sealed cable leadins. 35,400 38,704 10 69 Microvawe barrier for level SIUR-03V2.6 VIGT.407629.026 Non-contact point level detection in solids with free space radar sensors. Control of bulk material levels at high temperatures. Antennas are inserted inside the controlled volume. Allowable temperature of antennas: +200 С. Allowable temperature of alarm unit housings: -25 +85 С. Alarm consists of two units installed on the opposite silo walls and mounted with 1 sleeves welded on to walls (sleeves can be included in the scope of supply as options on request). Alarm is equipped with 300 mm long antennas covered with ceramic plugs to enable leading antennas directly into the area with temperatures up to +200 С. Electronic units are connected using sealed cable leadins. 39,530 70 Electron paramagnetic resonance spectrometer FIZEPR-ESR12 VIGT.421400.012 71 Control cabinet VIGT.301413.010 (with digital indicator) 72 Converter АС4 by "Owen" Additional equipment The electron paramagnetic resonance (ESR) spectrometer is designed to measure the microwave absorption dependence of material containing paramagnetic particles on a magnetostatic field induction. The spectrometer allows registering the presence of paramagnetic centers in the material, as well as determining their concentration. In particular spectrometer can be used to measure the concentration of free radicals in solutions and dry material samples. For discrete control of external devices depending on moisture measurement results Instrument cabinet 400х300х150 mm, IP54, with an installed and connected electronic unit. Supplied with: - measuring and regulating device TRM-201; - supply unit BP30B-D3-24; - RS485-USB interface converter AС-4 1,850,000 28,320 USB RS485 interface converter (24V mains supply) 3,000*

73 Converter ACDR.426469.032 by NVP "Bolid" 74 Measuring and regulating device TRM-201 by "Owen" 75 Digital operator panel SMI1 by "Owen" 76 Meter and controller device METAKON- 1105 by "KontrAvt" 77 Supply unit BP30B-D3-24 by "Owen" USB RS485 interface converter (PC USB port supply) 1,850* Digital indicator with a programmable device for discrete control of relay outputs 4,500* Data display panel with editing functions for distribution control systems in RS-485 network 5,960* (Modbus RTU protocol). Digital indicator with a programmable device for discrete control of relay outputs 6,800* Supply unit 24V 2,500* Note: * Approximate price; the device is supplied at the manufacturer's price including a transp. margin 11 Архангельск (8182)63-90-72 Астана +7(7172)727-132 Астрахань (8512)99-46-04 Барнаул (3852)73-04-60 Белгород (4722)40-23-64 Брянск (4832)59-03-52 Владивосток (423)249-28-31 Волгоград (844)278-03-48 Вологда (8172)26-41-59 Воронеж (473)204-51-73 Екатеринбург (343)384-55-89 Иваново (4932)77-34-06 Ижевск (3412)26-03-58 Казань (843)206-01-48 Калининград (4012)72-03-81 Калуга (4842)92-23-67 Кемерово (3842)65-04-62 Киров (8332)68-02-04 Краснодар (861)203-40-90 Красноярск (391)204-63-61 Курск (4712)77-13-04 Липецк (4742)52-20-81 Магнитогорск (3519)55-03-13 Москва (495)268-04-70 Мурманск (8152)59-64-93 Набережные Челны (8552)20-53-41 Нижний Новгород (831)429-08-12 Новокузнецк (3843)20-46-81 Новосибирск (383)227-86-73 Омск (3812)21-46-40 Орел (4862)44-53-42 Оренбург (3532)37-68-04 Пенза (8412)22-31-16 Пермь (342)205-81-47 Ростов-на-Дону (863)308-18-15 Рязань (4912)46-61-64 Самара (846)206-03-16 Санкт-Петербург (812)309-46-40 Саратов (845)249-38-78 Севастополь (8692)22-31-93 Симферополь (3652)67-13-56 Смоленск (4812)29-41-54 Сочи (862)225-72-31 Ставрополь (8652)20-65-13 Сургут (3462)77-98-35 Тверь (4822)63-31-35 Томск (3822)98-41-53 Тула (4872)74-02-29 Тюмень (3452)66-21-18 Ульяновск (8422)24-23-59 Уфа (347)229-48-12 Хабаровск (4212)92-98-04 Челябинск (351)202-03-61 Череповец (8202)49-02-64 Ярославль (4852)69-52-93 E-mail: fzp@nt-rt.ru Cite: http://fizepr.nt-rt.ru

Table showing design versions of in-line moisture meters for liquid materials Sensor design versions: - 20 - straight-flow (with two on the same axis); - 22 - U-type (bypass, two flanged branches on one side of the sensor); - 23 - straight-flow, for extreme temperatures and pressures; - 24 - L-type (angle, twp at 90º); - 25 Z-type (two flanged branches on the sensor side, turned at 90º or 180º) PN, bar DN, mm 50 65 80 100 125 150 Sensor design version: -21 - immersion, full-flow, with one flange, for DN 150 mm 6 20.14 20.10 21.01 12 10 20.4 20.19 16 25 40 63 20.5 22.5 24.5 25.5 20.8 22.8 24.8 25.8 20.11 22.11 24.11 25.11 20.6 22.6 20.16 20.7 20.17 20.9 22.9 24.9 25.9 20.12 22.12 24.12 25.12 20.20 24.20 25.20 20.21 24.21 25.21 100 20.15 20.22 21.05 20.18 160 23.01 25.18 200 23.02 23.65 20.65 21.02 21.03 21.04