Pressed pellets. Liquids, Slurries. Loose powders, Rocks, Granules. Metal cuts, Solids. Fused beads. Small parts. Coatings, Foils

Similar documents
XRAY SHARK XBD50/XBD51 X-Ray Inspection System for Glass-in-Glass Detection

Sistema de Detecção Raio-X

1,000W (DAP-60K: 100 W per digestion vessel)

PSA Series. Particle Size Analyzer

The Intelligent Choice for Rapid, Accurate Microwave Moisture/Solids Analysis. Innovators in Microwave Technology. Chemicals & Coatings.

Systems. Visit us at

The Viva-ProE System

Features and Benefits

THE NEW GENERATION VACUUM PUMP SYSTEM SC

Huminator II. Precision Humidity Generator. ww.testo.in

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

AGILENT VS SERIES LEAK DETECTORS

Features and Benefits

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

SIZE REDUCTION TECHNOLOGY

Complexity Simplified

AV6419 BOTDR. Product Overview. Main Features

May 2018 TALL PACKAGED PRODUCT INSPECTION. Discover what you've been missing DETECTION PERFECTION

Modular Circular Polarimeters

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

Variable Temperature Microprobe Systems

BAC 4000a BAC 5000yf

Pilot Freeze Dryers Smart Processes

X-ray Inspection System Discover What You've Been Missing... DETECTION PERFECTION

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

MOXTEK MULTI-LAYER OPTICS AND X-RAY TECHNOLOGY

gas monitoring system

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Inspection Machines Ampoules, Vials, Cartridges, LVP, Pre-filled Syringes. When Inspection Needs Perfection

VS LD series vertical steam sterilizers

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

CLARITY II TURBIDIMETER

IC Professional Detector

Integrated Process Solutions. Series 49. Thermal Management System

AZTECA A LITRE STERILISER

Modular Circular Polarimeters

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Parker icount Oil Sampler (IOS)

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

DP 300 mobile dew point instrument

AC1234 PRODUCT RANGE.

Advantages / Characteristics

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Product data sheet Palas Fidas 200 S

BGA Rework Station Pro-660

FREEZE DRYER LYOPHILIZER PRODUCTS LABFREEZ INSTRUMENTS CO., LTD

FreeZone 2.5 Liter Benchtop Freeze Dryers

High Throughput Large Area Silicon Drift Detectors

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

SONOCHEK The ultrasonic testing device

Thermo Scientific Heratherm Heating and Drying Ovens. Efficient, safe and easy

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

The No.1 choice for Veterinary care and animal recovery.

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

North American Technical Services

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

NC 100. Vertical Steam Sterilizer

Ultra-Thin Flexible Heaters

Temperature Control Systems

METPOINT THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE

laboratory & sterilization technology

CEIA THS/PH21. series HIGH PERFORMANCE PHARMACEUTICAL METAL DETECTION SYSTEMS. Superior and Consistent Detection Enhanced Product Throughput Rate

Improving Productivity, Quality and Security

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

DiluFlow. Gravimetric dilutors for solid samples. The best solution for your dilutions!

Hotplates, Magnetic Stirrers and Stirring Hotplates

More Precision. thicknesssensor // The sensor for precise thickness measurements

Best Freeze Drying Solutions

Automatic Distillation testing. Innovation in distillation. by Orbis BV.

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Alpha Analyst. Integrated Alpha Spectrometer. Radiation Safety. Amplified.

S ATION EWORK ST BGA R

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Innovation in distillation. PAMv2. Automatic Distillation testing. by Orbis BV

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

HALT & HASS Systems.

ACQUITY UPLC HT Column Heater Instructions

PG 8535 Perfect Reprocessing

Film Extrusion, Extrusion Coating, and Lamination Processes

RAYCHEM NGC-30 COMPONENTS

MiniWAVE Microwave Digestion Made Easy

ice 3000 Series Atomic Absorption Spectrometers

Methods of Desiccation

Dräger X-am 7000 Multi-Gas Detection

Metso MX. Multi-Action cone crusher

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

HydroSpeed plate washer for 96- and 384-well formats

Make critical-care decisions with fast, accurate results.

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

HPLC Column Ovens and Temperature Controllers

ASM 340. Best in class leak detector for high reliability testing in various applications, using helium and hydrogen

PLC Control Touch-Screen

SPC-56 SHORT PLANT.

Transcription:

Education Cosmetics, Pharmaceuticals Environmental Metal cuts, Solids Loose powders, Rocks, Granules Pressed pellets Fused beads Liquids, Slurries Filters Films, Coatings, Foils Small parts 11

S2 PUMA with TouchControl : Intuitive, failsafe ease-of-use Island mode: Full functionality without PC, keyboard and mouse Free language selection: English, German, French, Spanish, Portuguese, Italian, Russian, Chinese, Japanese No training required get results from day one Adjustable touchscreen, glovefriendly Island mode: No PC, keyboard and mouse required in routine operation Adjustable TouchControl interface TouchControl for quick, failsafe ease-of-use Quick, easy sample loading Sample rotation for accurate results Liquid sample analysis 12

EDXRF made easy, only with S2 PUMA and TouchControl Highest intensity with S2 PUMA ~ 20 % S2 PUMA Previous system Thanks to TouchControl, the operation of the S2 PUMA is easy and straightforward. The times of never-ending training, manuals that weigh a ton and operation with adventures in body contortions belong to the past. cps/ma With TouchControl, any user can perform measurement jobs on the S2 PUMA. First, select the application and key in the sample ID. You can also add additional information, like preparation or sample weight. Then simply start the measurement and view the results on-screen. But it gets even easier: An operator places a sample in the loader and taps the touchscreen once; this starts a predefined automatic application and that s it! Ca Ka Ultimate stability with S2 PUMA Ca Kb KeV Instrument precision is the key for tight process control. The S2 PUMA delivers excellent precision with its HighSense technology, the 50-Watt power of the X-ray tube and the all-new closely coupled beam path. This superior design guarantees process control at its best with a very narrow range for the results, minimizing waste and maximizing yield in your process. Concentration [%] 1.4 1.2 1.0 0.8 0.6 0.4 0.2 K Ca Mg 0 2 4 6 8 10 12 14 16 18 20 Measurements 13

Geology Metals, Coatings Plastics, Polymers Pharmaceuticals Research, Academia, Material Science Quick loading of sample batches or large samples with the S2 PUMA EasyLoad Carousel 14

02588_S2_PUMA_MON35.qxp_210x279 02.04.15 14:19 Seite 15 Service Labs Automotive No limitations in sample handling S2 PUMA Sometimes you simply need flexibility: First, some large samples you cannot destroy. Then, What is this black spot in the plastic building block? Next, analyze 12 geological samples as pressed pellets! Every job request is different. No need to worry, the S2 PUMA EasyLoad Carousel is the most adaptable configuration. It handles large samples directly. Place the block directly in the measurement position, control it with the integrated video camera, and use the collimator to analyze only the black spot. But place the EasyLoad tray in the chamber and it turns into an autosampler system for large batches. Metal cuts, Loose powders, Solids Rocks, Granules Pressed pellets Fused beads Liquids, Slurries Filters Films, Coatings, Foils Small parts Large parts, Electronis, PCBs Toys, Consumer products 15

Large-sample handling at its best height max. 96 mm (3.8 ) depth max. 428 mm (16.9 ) width max. 457 mm (18.0 ) Footprint and height of the spectrometer chamber are limiting the maximum size of large samples which can be loaded into the spectrometer. With a sample chamber footprint of 45 x 42 cm the S2 PUMA sets a new worldrecord. Raising carousel tray during transportation Lowering carousel tray during measurements EasyLoad Carousel tray Sample positioning with video camera Loading of large samples 16

S2 PUMA EasyLoad Carousel Unlimited flexibility for all kinds of samples The S2 PUMA EasyLoad Carousel accommodates up to 12 different samples in one tray. Samples can be powders, solids, pressed pellets, fused beads, or liquids, of sizes 32 mm, 40 mm or 51.5 mm in diameter. Different sample types and sizes can be even mixed on a single carousel tray. The S2 PUMA Carousel sets new standards not only for small samples. How to measure large samples if you don t want to cut them to size? Nothing could be easier just remove the tray and the sample chamber provides space for large-sample non-destructive elemental analysis. Very small to large samples of up to 45 x 42 cm can be directly analyzed in the S2 PUMA EasyLoad Carousel. Mark the spot and document your XRF measurements. For exact sample positioning, a video camera is integrated in the S2 PUMA, providing a close-up view of the sample and enabling you to ensure that just the right spot is analyzed. A video camera image is saved along with the EDXRF measurement data and results for later reference. Discover parts of your sample with small spot analysis. When performing failure analysis, analyzing geological samples or investigating consumer product safety, a specific small spot of the sample is of interest. The S2 PUMA is equipped with an integrated collimator to perform analyses of small spots from a couple of centimeters down to a few millimeters. Coating applications of multilayers no problem for the S2 PUMA. Quick loading of sample batches with the S2 PUMA EasyLoad Carousel In research & development and materials science, multilayer systems are designed for specific functionality. The S2 PUMA delivers accurate results for layer thickness and composition of single and multilayer samples. The analytical Multilayer software handles EDXRF data from large samples, bulk samples and small spots! 17

Safe sample handling with S2 PUMA SampleCare 1 2 3 4 5 Grabber with unique sample detection DuraBeryllium tube shield 10-position filter wheel DustShield detector cap Dust reservoir 1 2 3 4 5 Stops dust & liquids S2 PUMA with SampleCare : Unique contamination protection of important system components Guarantees highest instrument uptime Prevents drawbacks from sample leakages Failsafe recognition of liquid cups Grabber with automatic sample detection DuraBeryllium shield for tube window protection Unique detector cap for detector protection Avoids spillage of liquids and contamination with small sample particles on detector head DustShield detector cap 18

S2 PUMA with SampleCare Instrument uptime is crucial in every laboratory. But you can rely on the S2 PUMA with Bruker s unique SampleCare technology. SampleCare protects the instrument from damage due to sample contamination. The integrated liquid sample detection of the EasyLoad XY Autochanger disables the vacuum mode whenever a liquid sample is detected. In addition, a DuraBeryllium tube shield and the filter wheel protects the X-ray tube. A third contamination shield is the detector cap. The cap with an ultra-thin protection foil avoids contamination when liquid samples spill or small sample particles fall from pressed powders. S2 PUMA with powerful software To control your S2 PUMA we deliver a powerful analytical software package. Setting up an application with the Solution Editor, starting measurements, evaluating scans, reporting results or exporting data the software provides simple control of all these functions. The Solution Editor is based on Bruker s established integrated analytical intelligence for ease-of-use. You always keep an overview on all your applications, and if needed the software solution provides you with all the necessary settings to obtain best results. Setting up applications, maintaining methods and obtaining excellent results has never been so easy. Built to last S2 PUMA with SampleCare Built to analyze S2 PUMA with powerful software 1 3 5 1 2 Solution Editor with tree structure to maintain all relevant application parameters. Selected Manage Standards to enter all information on calibration standards. 2 4 3 4 Overview about the standards for the steel application. Spectrum of steel standard for evaluation of element lines. 5 Periodic table for convenient element selection. 19

Technical Data S2 PUMA Single S2 PUMA XY Autochanger S2 PUMA Carousel Elemental range Sodium to uranium (Na U) with standard XFlash Carbon to uranium (C U) with XFlash Light Element (LE) Concentration range From ppm to 100 % X-ray tube Primary beam filters Detector Collimator masks Sample observation Mode TouchControl Connectivity Power requirements Automation Sample types Sample rotation Sample sizes Sample loader Dimensions width x depth x height; weight Quality & safety Pd or Ag anode; max. power 50 W; max. voltage 50 kv 10-position automatic filter changer; for wide range elemental analysis pre-installed filters: 5 µm Ag, 20 and 500 µm Al, 100 and 250 µm Cu XFlash Silicon Drift Detector: Peltier cooled (no need for liquid nitrogen) Standard XFlash detector: resolution typ. 135 ev at Mn Ka and 100 000 cps XFlash detector LE: resolution typ. 141 ev at Mn Ka and 100 000 cps For small spot analysis: 1, 3, 8, 12, 18, 23 and 28 mm (optional) Integrated HD video camera, for exact sample positioning and documenting the measurement position of a sample (optional) Air mode Gas flushing (optional): N 2 or Helium for liquids and loose powders Vacuum pump (optional): Enhanced light element performance, low cost of operation Integrated 12.1 TFT touchscreen, multilingual user interface Built-in Ethernet port RJ45, 4x USB ports for mouse, keyboard, printer 100-240 V, 50/60 Hz, max. power consumption 600 VA Connectivity to conveyor belt (optional) Loose powders, granules, solids, pressed pellets, fused beads and liquids up to 50 ml (optional) S2 PUMA Single S2 PUMA XY Autochanger S2 PUMA Carousel Up to 51.5 mm (2.03 ) Ø samples. Liquids, loose powders and smaller samples in liquid cups: up to 50 ml Single position, manual 66 x 70 x 37 cm; 81 kg 26 x 27.6 x 14.6 ; 179 lbs Up to 40 mm (1.56 ) Ø and 38 mm (1.49 ) height in sample holders, max. weight 200 g or 51.5 mm (2.03 ) Ø as sample ring. EasyLoad XY sample tray, 20-position, removable; Grabber with automatic sample detection 66 x 70 x 60 cm; 112 kg 26 x 27.6 x 23.6 ; 247 lbs 32, 40 or 51.5 mm (1.26, 1.56 or 2.03 ) Ø samples. Large samples: width max. 457 mm (18.0 ) depth max. 428 mm (16.9 ) height max. 96 mm (3.8 ) EasyLoad Carousel sample tray, 12-position, removable 66 x 70 x 56 cm; 127 kg 26 x 27.6 x 22.0 ; 278 lbs DIN EN ISO 9001:2008; CE-certified Machinery directive 2006/42/EC; Electrical equipment 2006/95/EC; Electromagnetic Compatibility 2004/108/EC; Fully radiation-protected system; radiation < 1 µsv/h (H*); German type approval (BfS) for X-ray safety; Conform to ICRP, IAEA, EURATOM Bruker AXS is continually improving its products and reserves the right change specifications without notice. DOC-B80-EXS015. 2015 Bruker AXS. aim 02588 Bruker AXS GmbH Karlsruhe. Germany Phone +49 (0)721-50997-0 Fax +49 (0)721-50997-5654 info@bruker-axs.de TouchControl, SampleCare, EasyLoad, HighSense and DustShield are trademarks of Bruker AXS Inc.; XFlash is a registered trademark of Bruker Nano Analytics DuraBeryllium is a trademark of Moxtek Inc. www.bruker.com