Optical Beam Smoke Detector RK90R - RK90RS

Similar documents
RK100B - RK200B RK100BS - RK200BS

FLV 40 UV Flame Detector

EDS - SPARK DETECTORS - GENERAL NOTES

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Beam Detectors. The 6500 Series

Installation and Operation Manual

FIRERAY 5000 range USER GUIDE

HART XL High Sensitivity Smoke Detection

Motorised Infrared Optical Beam Smoke Detector. User Guide

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

English. Series. Installation and Use Manual

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS

Fireray 2000 Linear Smoke Detector

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

INDEX. Installation recommendation

this is by far the best beam money can buy

HART XL High Sensitivity Smoke Detection

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

Intelligent addressable fire alarm control panel

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

Reflective Optical Beam Smoke Detector User Guide

Line Smoke Detector LRMX

CONFIGURATION OF THE OPTICALS

ALK-V PHOTOELECTRIC SMOKE SENSOR

FLV45 FLV45A FLV45A-AL

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Fact File 66. Guide to Beam Smoke Detectors

TECHNICAL SPECIFICATIONS BUTTONS

Installation And commissioning manual. Series S Double Beam 1/16

Open-area Smoke Imaging Detector. Engineering Specification

Open-area Smoke Imaging Detection (OSID)

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

C-9105R Conventional Reflective Beam Detector Installation and Operation Manual. (Issue 2.01, February 2006)

INDEX. Installation recommendation

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

Laser Collimated Beam Sensor

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Open-area Smoke Imaging Detection (OSID)

Key Features. General Description

Laser Technology Smoke Detector

Analogue Detectors. Series 200 plus

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector

FR-A180 FR-A360. Occupancy detector. Use

OH110, OP110, HI110 Automatic fire detectors

CATALOGUE LASER POINTERS

Intelligent Addressable Fire Alarm System

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

ASA linear smoke detector

Explosion-proof ATEX Spark Detector SCL-01

MODEL 6200 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. (Issue 2.03 February 2006)

DUAL OPTIC. Installation manual

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Active Infrared Multi Beam Sensors

D296/D297. Application Guide. Projected Beam Smoke Detectors

End To End Optical Beam Smoke Detector. Additional Information

Active Infrared Multi Beam Sensors. R Series

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

EN 54/12 EN /96/CE. ECO con snodo - with articulated bracket - mit Kugelge- ECO con snodo - with articulated bracket - mit Kugelgelenk

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

INDEX. Installation recommendation

Beam detector DBD-DL40 KBD-DL80 KBD-DL100

Class 1 laser beam sensor safe for your eyes

850 Series Fire Detectors - Generation 6

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Cerberus FIT conventional system

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS

Solution F2. Fire Alarm Control Panels one step ahead.

850 and 830 Series. Fire Detectors - Generation 6

Chapter 17, Initiating Devices

Synchronous Detector

830 Series. Fire Detectors - Generation 6

Class 1 laser beam sensor safe for your eyes

CAUTIONS ON INSTALLATION

Range brochure. Beam detection. others look up to.

Laser Distance Sensor Type M Analog-Output

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

SecuriBeam Optical Beam Fire Detectors

CODESEC FIRE ALARM SYSTEMS. security technologies

Open-area Smoke Imaging Detection (OSID)

Transcription:

Optical Beam Smoke Detector RK90R - RK90RS TECHNICAL INFORMATION APPLICATIONS museums churches art galleries libraries hotels shops cinemas computer rooms control rooms storehouses, etc. The RK90R it's a reflection Beam Smoke Detector. Its operation is based on the relation between the smoke present in an environment, generated by the starting of a fire, and the infrared beam emitted by the device and reflected by a special optical reflector. It is also able to detect the presence of vapour and fog. A fundamental feature of this detector is the ability to detect the presence of both white smoke and black smoke even if they are little dense. This detector has been designed for applications where the aesthetics, the small dimensions, the possibility of remote visualization of the signal and the simplicity of use have primary importance. So RK90R is particularly suitable to be installed in artistic environments like museums, churches, art galleries and in offices, hotels etc. TECHNICAL FEATURES a single detector can cover an area up to 750 mq. installation is easy and quick the internal electronics are controlled by a microprocessor a special function automatically compensates the signal drift caused by the opacity on the optical parts, generated by dust and dirt, minimizing the maintenance needs the detector RK90R has 2 separated circuits for smoke detection: Oscuration and Turbulence the detector RK90RS has only the circuits for smoke detection: Oscuration RK90R - 3 relay outputs: Alarm, Turbulence, Fault RK90RS - 2 relay outputs: Alarm, Fault analog output that allows to remotely visualize the detector's signal level using an optional led bar module maintenance is easy and not frequent very low operational costs - cost effective simplified allignment with signal level led indication EN54-12 CPD and VDS certified CERTIFIED EN54-12 VDS CPD

OPERATION TECHNICAL DATA The RK90R it's an Optical Beam Smoke Detector suited with 2 separated detection circuits based on the principles of Obscuration and Turbulence (RK90R) Oscuration The device has to be installed at one end of the area to be protected just under the level of the ceiling and the special reflector (FX) must be installed at the other end. When a fire begins, it produces smoke that rises up and intercepts the infrared beam of the detector. This causes an attenuation of the received signal that, if the threshold level is reached, will activate its alarm relay that can drive suitable alarm signalling devices. Turbulence Normally, during the starting phase of a fire, smoke clouds are generated and the thermal energy of the fire (heat) produces bubbles of hot air that rise up. When these clouds and bubbles intercept the beam emitted by the detector, they cause a perturbation in it because they modify the optical-physical caratheristics of the transmission medium of the beam. These variations are obviously time related. A suitable circuit has been designed to detect these variations and when they reach the preset amplitude and time duration levels, an alarm signal is generated. The advantage of using the turbulence detection circuit it's a quicker detection of the fire, because it is revealed in it's beginning. So RK90R, with this circuit, reveals dinamically both the smoke clouds by the starting of the fire and, in case the fire generates flames and so thermal energy, the perturbation phenomena produced by the combustion process. Optical Reflectors 4 types of optical reflectors can be used with RK90R: FX01 - FX02 - FX03 - FX07. The reflectors choice has to be done according to the optical path lenght (distance beween detector and reflector) and to aesthetic needs of the environment. The FX07 it's particularly suitable to be installed in artistic places (museums, art galleries, etc). Options ZC-01 - It is a optional base that facilitates the installation in the 01 is equiped of breakable holes on the sides. SUP90 - It is a adjustable support that allows the orientation of the optical beam in various directions. It is useful in the case of installation of the detector of the detector in an angle of the room. BLP-90 - Laser Pointer - eliminates the need to use a lamp for optical alignment detector-reflector - the pointer is installed and collimated in the laboratory - the time of installation of the detector is drastically reduced - just point the laser beam on the reflector to have optics aligned. 01 case in which the cable within pipe guide is outside of the wall. The ZC- ZC- Models: RK90R RK90RS (without Turbulence) Type: Reflection Optical Beam Smoke Detector Manufacturer: EDS srl - V. Cà Nova Zampieri 6-37057 S.G. Lupatoto - Verona - ITALY Power Supply: 12/24 Vdc Power Supply Range: 11-30 Vdc Optical Path Lenght: 3-12 m with FX-07 reflector 10-25 m with FX-01 reflector 20-40 m with FX-02 reflector 25-50 m with FX-03 reflector Max covered area: 750 mq Protection against the inversion of polarity Digitally codified infrared beam Power Consumption: 18,6 ma in normal operation 34 ma with the alarm relay activated 34 ma with the turbulence relay activated 50 ma with both alarm and fault relay activated Maximum angular missallignment of the detector: +/- 0,2 Maximum angular missallignment of the reflector: +/- 0,2 Selection of the obscuration alarm threshold level with a 4 positions switch: position 1-70% position 2-60% position 3-50% position 4-40% Selection of the turbulence alarm threshold level with a 4 positions switch Alarm Relay activation delay: 10 s Fault Relay activation delay: 5 s Detector's recovery time with alarm memory dectivated: about 5 s Detector's recovery time with alarm memory activated: about 5 s (power supply off) Working temperature: -10 + 55 C Red LED indication: alarm status Blue LED indication: compensation limit, interrupted beam, fault Alarm Relay: 1A/24 V dc Turbulence Relay: 1A/24 V dc - (RK90R) Fault/Maintenance Relay: 1A/24 V dc 0-5 V Analog Output for signal level measuring/ visualization Dimensions: 162 x 62 x 62 mm. Housing: autoextinguishing policarbonate box Relevant Standard: EN 54-12 Certifications: EN54-12/CPD (0786-CPD-20803), VDS2504-VDS2344 (G209131) Protection Index: IP 50 (IEC 529-144) Weight: 200 gr.

Optical Beam Smoke Detector RK100R - RK100RS TECHNICAL INFORMATION APPLICATIONS industrial buildings storehouses supermarkets shops libraries theaters cinemas conference halls control rooms hotels The RK100R it's a reflection Beam Smoke TECHNICAL FEATURES Detector. CERTIFIED a single detector can cover an area up to 1500 mq. EN54-12 installation is easy and quick Its operation is based on the relation between the internal electronics are controlled by a the smoke present in an environment, generated by the starting of a fire, and the infrared beam emitted microprocessor a special function automatically compensates the signal drift caused by the opacity on the optical parts generated by dust by the device and reflected by a special optical reflector. It is also able to detect the presence of vapour and fog. and dirt minimizing the maintenance needs the detector RK100R has 2 separated circuits for smoke detection: Oscuration and Turbulence A fundamental feature of this detector is the ability to detect the the detector RK100RS has only the circuit for smoke presence of both white smoke and black smoke even if they are detection: Oscuration RK100R - 3 relay outputs: Alarm, Turbulence, Fault little dense. RK100RS - 2 relay outputs: Alarm, Fault This detector has been specifically designed for industrial analog output that allows to remotely visualize the detector's applications where quality, reliability, precision and easyness of signal level using an optional led bar module maintenance is easy and not frequent use have primary importance. very low operational costs- cost effective Remote visualization is available using an optional module. simplified allignment with signal level led indication EN54-12 CPD and VDS certified

OPERATION TECHNICAL DATA The RK100R it's an Optical Beam Smoke Detector suited with 2 separated detection circuits based on the principles of Obscuration and Turbulence (RK100R). Oscuration The device has to be installed at one end of the area to be protected just under the level of the ceiling and the special reflector (FX) must be installed at the other end. When a fire begins, it produces smoke that rises up and intercepts the infrared beam of the detector. This causes an attenuation of the received signal that, if the threshold level is reached, will activate its alarm relay that can drive suitable alarm signalling devices. Turbulence Normally, during the starting phase of a fire, smoke clouds are generated and the thermal energy of the fire (heat) produces bubbles of hot air that rise up. When these clouds and bubbles intercept the beam emitted by the detector, they cause a perturbation in it because they modify the optical-physical caratheristics of the transmission medium of the beam. These variations are obviously time related. A suitable circuit has been designed to detect these variations and when they reach the preset amplitude and time duration levels, an alarm signal is generated. The advantage of using the turbulence detection circuit it's a quicker detection of the fire, because it is revealed in it's beginning. So RK90R, with this circuit, reveals dinamically both the smoke clouds by the starting of the fire and, in case the fire generates flames and so thermal energy, the perturbation phenomena produced by the combustion process. Optical Reflectors 4 types of optical reflectors can be used with RK90R: FX01 - FX02 - FX03 - FX07. The reflectors choice has to be done according to the optical path lenght (distance beween detector and reflector) and to aesthetic needs of the environment. FX - 09 is particularly suitable for application with short optical path and where good aesthetics are needed. Option BLP-100 - Laser Pointer - eliminates the need to use a lamp for optical alignment detectorreflector - the pointer is installed and collimated in the laboratory - the time of installation of the detector is drastically reduced - just point the laser beam on the reflector to have optics aligned. Model: RK100R Type: Reflection Optical Beam Smoke Detector Manufacturer: EDS srl - V. Cà Nova Zampieri 6-37057 S.G. Lupatoto - Verona - ITALY Power Supply: 12/24 Vdc Power Supply Range: 11-30 Vdc Optical Path Lenght: 10-30 m with FX-09 reflector 25-70 m with FX-01 reflector 35-80 m with FX-02 reflector 45-100 m with FX-03 reflector Max covered area: 1500 mq Protection against the inversion of polarity Digitally codified infrared beam Power Consumption: 18,6 ma in normal operation 34 ma with the alarm relay activated 34 ma with the turbulence relay activated 50 ma with both alarm and fault relay activated Maximum angular missallignment of the detector: +/- 0,2 Maximum angular missallignment of the reflector: +/- 0,2 Selection of the obscuration alarm threshold level with a 4 positions switch: position 1-70% position 2-60% position 3-50% position 4-40% Selection of the turbulence alarm threshold level with a 4 positions switch Alarm Relay activation delay: 10 s Fault Relay activation delay: 5 s Detector's recovery time with alarm memory dectivated: about 5 s Detector's recovery time with alarm memory activated: about 5 s (power supply off) Working temperature: -10 + 55 C Red LED indication: alarm status Blue LED indication: compensation limit, interrupted beam, fault Alarm Relay: 1A/24 V dc Turbulence Relay: 1A/24 V dc - (RK100R) Fault/Maintenance Relay: 1A/24 V dc 0-5 V Analog Output for signal level measuring/ visualization Dimensions: 247 x 146 x 114 mm. Housing: autoextinguishing policarbonate box Relevant Standard: EN 54-12 Certifications: EN54-12/CPD (0786-CPD-20803), VDS2504-VDS2344 (G209131) Protection Index: IP 65 (IEC 529-144) Weight: 900 gr.

Optical Beam Smoke Detectors RK100B-RK200B RK100BS -RK200BS TECHNICAL INFORMATION APPLICATIONS industrial buildings storehouses supermarkets shops libraries theaters cinemas conference halls control rooms hotels The RK100B and RK200B are Optical Beam CERTIFIED TECHNICAL FEATURES Smoke Detectors with separated Trasmitter (TX) EN54-12 a single detector (TX+RX) ac cover an area VDS CPD up to 1.600 mq (EN54-14 standard) and Receiver (RX). The RK100B detector has a installation is easy and quick maximum optical path of 120m. The RK100B the internal electronics are controlled by a detector has a maximum optical path of 200m. microprocessor Their operation is based on the relation between the smoke present a special function automatically compensates the signal drift caused by the opacity on the optical parts generated by dust in an environment, generated by the starting of a fire, and the and dirt minimizing the maintenance needs infrared beam emitted by the transmitter towards the receiver. the detectors RK100B-RK200B have 2 separated circuits for It is also able to detect the presence of vapour and fog. A fundamental feature of this detectors is the ability to detect the presence of both white smoke and black smoke even if they are smoke detection: Oscuration and Turbulence the detectors RK100BS-RK200BS have only circuits for smoke detection: Oscuration RK100B-RK200B - 3 relay outputs: Alarm, Turbulence, Fault RK100BS-RK200BS - 2 relay outputs: Alarm, Fault little dense. analog output that allows to remotely visualize the detector's This detectors have been specifically designed for industrial signal level using an optional led bar module maintenance is easy and not frequent applications where quality, reliability, precision and easyness of very low operational costs - cost effective use have primary importance. simplified allignment with signal level led indication Remote visualization is available using an otional module EN54-12 CPD and VDS certified

OPERATION The RK100B and RK200B are Optical Beam Smoke Detectors suited with 2 separated detection circuits based on the principles of Obscuration and Turbulence (RK100B-RK200B). Oscuration The transmitter has to be installed at one end of the area to be protected just under the level of the ceiling and the receiver must be installed at the other end. When a fire begins, it produces smoke that rises up and intercepts the infrared beam of the detector. This causes an attenuation of the received signal that, if the threshold level is reached, will activate its alarm relay that can drive suitable alarm signalling devices. Turbulence Normally, during the starting phase of a fire, smoke clouds are generated and the thermal energy of the fire (heat) produces bubbles of hot air that rise up. When these clouds and bubbles intercept the beam emitted by the detector, they cause a perturbation in it because they modify the optical-physical caratheristics of the transmission medium of the beam. These variations are obviously time related. A suitable circuit has been designed to detect these variations and when they reach the preset amplitude and time duration levels, an alarm signal is generated. The advantage of using the turbulence detection circuit it's a quicker detection of the fire, because it is revealed in it's beginning. So RK90R, with this circuit, reveals dinamically both the smoke clouds by the starting of the fire and, in case the fire generates flames and so thermal energy, the perturbation phenomena produced by the combustion process. Option BLP-100 - Laser Pointer - eliminates the need to use a lamp for optical alignment detector-reflector - the pointer is installed and collimated in the laboratory - the time of installation of the detector is drastically reduced - just point the laser beam on the receiver RX. TECHNICAL DATA Models: RK100B-RK200B RK100BS-RK200BS Type: Barrier Optical Beam Smoke Detector Manufacturer: EDS srl - V. Cà Nova Zampieri 6-37057 S.G. Lupatoto - Verona - ITALY Power Supply: 12/24 Vdc Power Supply Range: 11-30 Vdc Max Optical path: 120 m for RK100B 200 m for RK200B Max cover area.: 1.600 sm (EN54-14 standard) Protection against the inversion of polarity Digitally codified infrared beam Power Consumption of TX: 9,5 ma Power Consumption of RX: 18,6 ma in normal operation 34 ma with the alarm relay activated 34 ma with the turbulence relay activated 50 ma with both alarm and fault relay activated Maximum angular missallignment of the detector: +/- 0,5 Selection of the obscuration alarm threshold level with a 4 positions switch: position 1-70% position 2-60% position 3-50% position 4-40% Selection of the turbulence alarm threshold level with a 4 positions switch Alarm Relay activation delay: 10 s Fault Relay activation delay: 5 s Detector's recovery time with alarm memory dectivated: about 5 s Detector's recovery time with alarm memory activated: about 5 s (power supply off) Working temperature: -10 + 55 C Red LED indication: alarm status Blue LED indication: compensation limit, interrupted beam, fault Alarm Relay: 1A/24 V dc Turbulence Relay: 1A/24 V dc - (RK100-200B) Fault/Maintenance Relay: 1A/24 V dc 0-5 V Analog Output for signal level measuring/ visualization Dimensions: 247 x 146 x 114 mm. Housing: autoextinguishing policarbonate box Relevant Standard: EN 54-12 Certifications: EN54-12/CPD (0786-CPD-20803), VDS2504-VDS2344 (G209131) Protection Index: IP 65 (IEC 529-144) Weight: 900 gr.

Laser Beam Pointer for Optical Beam SmokeDetectors BLP-90 BLP-100 TECHNICAL INFORMATIONS ACCESSORIES FOR EDS OPTICAL BEAM SMOKE DETECTORS they eliminate the need to use a lamp for the optical alignment of the detectors the laser pointers are already installed on the detector and optically collimated in the laboratory the procedure of optical alignment of the linear smoke detectors EDS with these pointers becomes extremely quick and easy CODES BLP-90...for RK90R BLP-100...for RK100R-100B-200B drastic reduction of the detectors installation time The alignment procedure of the detector with its reflector (for reflection detectors RK90R and RK100R) or between TX and RX (for barrier detectors RK100B and RK200B), consists in adjusting the optical crew, of which the detectors are equipped, in so that the bright spot of the laser (red dot) falls at the center of the reflector or its opposite element RX. The technical information in this document have been carefully checked and can be considered reliable. In any case the EDS Company is not responsable for any eventual inaccuracy and reserves the right to make changes to any part of this document and/or to the products, in order to improve their quality, reliability or design. EDS - ELECTRONIC DETECTION SYSTEMS Via Ca' Nova Zampieri 6 37057 S.G. Lupatoto - VERONA - ITALY Tel: 0039045547529 - Fax: 00390458750065 Web: www.eds.eu email: eds@eds.eu