D7044. Installation Instructions Multiplex Single Input Module

Similar documents
D7052. Installation Instructions Multiplex Dual Input Module

D7053. Installation Instructions Multiplex Input/Output Module

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

DS7465i. Installation Instructions. Input/Output Module

F220-B6PS/M. Installation Guide. Addressable Detector Bases

Addressable NAC Output Module D327A

Multiplex Eight Input Remote Modules

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

D250A/D253/D261AW/D280A/D290 Series

Notification Appliance Circuit Module

FMR Installation Instructions. Addressable Fire System Controller

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Remote NAC Power Supply D7038

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

D7024 Fire Alarm Control Panel

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

Duct smoke housing, 2-wire D340/D340P

D343. Installation Instructions. Air Duct Smoke Housing

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide

These instructions detail procedures to follow in order to avoid damage to equipment.

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

D1255RB/D1256RB/D1257RB

Battery charger modules

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

FireNET Plus Wiring Instructions

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

Fire Alarm Control Panels FPD-7024

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

RELEASE DEVICE CONTROLS

Commercial Series TriTech Motion Detector. Reference Guide

Addressable Fire Alarm Control Panel

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

DS160/161 Request To Exit PIR sensors Installation Instructions

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Addressable Detectors & Bases

Conventional Smoke Detectors KFAPO

Booster Power Supply Manual

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Print Specification. Publication. Instructions. Specific requirements. General requirements

UEI-1 UNIVERSAL END-OF-LINE / ISOLATOR TESTER

D2071A. Operation & Installation Guide Fire Alarm Control Panel

SIGA-CC1 Single Input Signal Module Installation Sheet

D720 and D1255 Command Centers

Signature Series Auto-Sync Output Module (CC1S)

Operation and Installation Guide. Zone Expansion Module D8125

MANUAL RESET ALARM RELEASE

Fire Control/Communicator

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

1. POWERPATH Operation

Protecting Lives and Assets FPD-7024 Fire Alarm Control Panel

Control Relay Modules

D296/D297. Application Guide. Projected Beam Smoke Detectors

DS7400Xi Addressable Control/ Communicator

MANUAL RESET ALARM RELEASE BOX

LifeAlarm Fire Alarm Controls

Bosch EVAX System - High-rise Applications

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

TrueAlert Notification Appliances

TrueAlarm Analog Sensing

30.45 Electric Release PDRP-2001

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

July 14, 1999 DF C-100.

4100U City and Relay Cards Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Commercial Series TriTech+ Motion Detector with Anti-mask

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

TrueAlarm Analog Sensing

Installation Guide. Control/Communicator

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multiple Input and Output Modules

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Independent Zone Control (I.Z.C.)

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

AlarmLine Linear Heat Detector

June 10, 2002 DF C S2424

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

MO144. Operators Guide. Universal Timer Module

AHJ Field Inspector Guide For: AES-IntelliNet Private Radio Network Installation Sites

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

Installation, Operating and Maintenance Manual

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

L-Series, Indoor Strobes and Horn Strobes

MR-2602 Two Zone Fire Alarm Control Panel

Transcription:

D EN Installation Instructions Multiplex Single Input Module

D Installation Instructions Notices Notices These instructions cover the installation of the D Multiplex Single Input Module in a fire system, supervised by a D or DSM Fire Alarm Control Panel (FACP) with firmware revision. or greater and a D or DS Multiplex Expansion Module. Install, test, and maintain the D according to these instructions, NFPA, Local Codes, and the Authority Having Jurisdiction (AHJ).. Description The D (Figure ) is a general purpose device that connects a contact device to the FACP multiplex bus with a supervised input loop. Figure : D Features Follow the procedures in these instructions to avoid personal injury and damage to the equipment. Failure to follow the procedures can result in the D not operating properly. Bosch is not responsible for improperly installed, tested, or maintained devices. Test the FACP according to NFPA. A B - Status LED - Zone input terminals - Mux bus loop terminals - Rotary address switches All operating power for the D is drawn from the FACP. Rotary switches provide convenient address setting. An on-board Status LED, visible through the faceplate, indicates normal operation and communication with the control panel. The LED flash rates are: Fast: Approximately sec indicating an alarm condition. Medium: Approximately sec indicating normal operation. Slow: Approximately sec indicating a trouble condition. The D can be mounted in a standard double-gang or a in. x in. electrical box. Bosch / D

D Installation Instructions. Setting the Address. Setting the Address Set the D address using a flat-bladed screwdriver to position each rotary switch located on the front of the module (Figure ). Note that the switches click when turned. Figure : D Address Setting A B Figure : Field Wiring Connections - Hundreds - Tens - Ones A = D FACP, B = DSM FACP For example: hundreds, tens, ones = Address on the D FACP The valid D address range is to. Refer to the D Operation and Installation Guide (P/N: ) or the DSM Reference Guide (P/N: ) for additional address limitations. The A address range works on the D Multiplex Expansion Module with the D FACP. The B address range works on the DS Multiplex Expansion Module with the DSM FACP. A B -. kω end-of-line (EOL) resistor UL Listed (P/N: ) - Zone in (+) - Zone in (-) Note: The maximum zone wire resistance = Ω. Figure : Loop and Panel Wiring Connections Figure shows the A address range set at, allowing the D to work with the D FACP.. Wiring Ensure all power is removed before making electrical connections. Failure to do so can result in personal injury and damage to the equipment. Connections are made using the terminals on either side of the D (Items and in Figure on page ). All terminals can accommodate up to and including AWG (. mm) wire. Follow the wiring guidelines as specified by NFPA- and the local AHJ. All wiring is power limited and supervised. Refer to Figures and for the two types of wiring connections. Use normally-open (NO) contacts for Underwriters Laboratories, Inc. (UL) Listed fire installations. - Mux bus loop (+) - Mux bus loop (-) - To next device - From previous device, the D, or the DS Bosch / D

D Installation Instructions. Installation. Installation Complete all wiring before mounting the D and faceplate.. Wire the D according to Figures and on page.. Mount the D on a standard double-gang box (Figure ) or in. x in. electrical box (Figure ). Figure : Mounting the D on a Double-Gang Box A B - Supplied mounting screws () - D Module - Double-gang box Figure : Mounting the D on an Electrical Box A B - Supplied mounting screws () - D Module - in. x in. electrical box Bosch / D

D Installation Instructions. Installation. Secure the faceplate to the front of the D (Figure ). Figure : Mounting the Faceplate D A B - Supplied mounting screws () - Faceplate - D Module on electrical box Bosch / D

D Installation Instructions. Specifications. Specifications Table : Specifications Control Panel Programming Type Control Panel Requirements Multiplex Bus Average Current Draw Operating Temperature Relative Humidity Single input D FACP with ROM version. or greater and a D Multiplex Expansion Module installed. Refer to the D Operation and Installation Guide (P/N: ) or the DSM Reference Guide (P/N: ) for specific programming information. Refer to the D Installation Instructions (P/N: ) or the DS Installation Instructions (P/N: ) for multiplex wiring information. Alarm: µa Standby: µa Nominal: V + F to + F ( C to + C) Maximum of %, non-condensing Listings and Approvals UL California State Fire Marshall (CSFM) Bosch / D

D Installation Instructions Notes Notes Bosch / D

Bosch Perinton Parkway Fairport, NY - USA Customer Service: () - Technical Support: () - Bosch D