Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Similar documents
GCS-300 No.GCS31E

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

INSTRUCTION MANUAL Micro-computer based digital indicating controller

Instruction manual Micro-computer based digital indicating controller

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

Instruction manual Temperature Controller KT7

Instruction manual for DIN rail mounting type indicating controller DCL-33A

DIGITAL INDICATOR JIR-301-M

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

DIGITAL INDICATOR DI25

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K

ISOLATOR SGI SGIW INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER. BCx2 INSTRUCTION MANUAL

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Series Temperature Controller Instruction Sheet

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL

TEMPERATURE CONTROLLER

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Universal controller for panel mounting Models CS6S, CS6H, CS6L

F4 Process Controller Installation and Operation Guide

MICRO CONTROLLER S Z SERIES

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

MICRO CONTROLLER E Z SERIES

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Temperature Controller

Temperature Controllers

UDC 700 Universal Digital Controllers and Indicator Specifications

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

TEMPERATURE CONTROL MODULE MODEL R3-TC2

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

CB103/CB403/CB PRODUCT CHECK 2. MOUNTING - * - / /Y INSTRUCTION MANUAL WARNING. 2.1 Mounting Cautions CAUTION RKC INSTRUMENT INC.

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

SR70 (SR ) Series Digital controller Instruction Manual

I/A Series 716C 1/16 DIN Temperature Controller

02/11/2015

Series Digital Controller Instruction Sheet

1. PRODUCT CHECK 2. MOUNTING - * - / /Y

Process & TeMPerATUre UniversAl input DigiTAl MeTers

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

1. PRODUCT CHECK 2. MOUNTING

CN4800 Series CONTROLLER

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

Nov 08 PRODUCT SPECIFICATION SHEET

02/11/2015

R Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

E5CN Temperature Controller User s Manual

General Specifications

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Hardware Instruction Manual. SR Mini HG SYSTEM. High-performance Multi-point Control System IMSRM15-E4 RKC INSTRUMENT INC.

Multi-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC.

Temperature Controller SA100. Initial Setting Manual IMR01J03-E1 RKC INSTRUMENT INC.

Digital Panel Meters 47 Series. DC INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LV OPERATING MANUAL

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

AE500 Instruction Manual

SHIMADEN DIGITAL INDICATORS

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

TC515 and TC600 Installation Manual. a Winters company

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

4TEMPERATURE CONTROLLER

Digital Heater Element Burnout Detector K8AC-H

Compact Ultra Low Temperature Chamber

UDC100 Universal Digital Controller Specifications

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

99 Washington Street Melrose, MA Phone Toll Free Visit us at

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC.

370, boulevard de Balmont LYON Tel Fax Web:

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

Oakton TEMP 9500 Advanced Multiparameter Controller

Specification , July 2015

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Advanced Ultraviolet Burner Controller

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

Model 96VTR ¼ DIN Process Controller

LA type soldering iron controller

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

+ A B V B NO NC V COM PV PV

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL

E5CN/E5CN-U (48 x 48 mm)

CONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Transcription:

INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual. Safety precautions (Be sure to read these precautions before using our products.) The safety precautions are classified into 2 categories: Warning and Caution. Depending on the circumstances, procedures indicated by Caution may be linked to serious results, so be sure to follow the directions for usage. Warning Caution Procedures which may lead to dangerous conditions and cause death or serious injury, if not carried out properly. Procedures which may lead to dangerous conditions and cause superficial to medium injury or physical damage or may degrade or damage the product, if not carried out properly. Warning To prevent an electric shock or fire, only Shinko or qualified service personnel may handle the inner assembly. To prevent an electric shock, fire or damage to the instrument, parts replacement may only be undertaken by Shinko or other qualified service personnel. Safety precautions To ensure safe and correct use, thoroughly read and understand this manual before using this instrument. This instrument is intended to be used for industrial machinery, machine tools and measuring equipment. Verify correct usage after consulting the purpose of use with our agency or main office. (Never use this instrument for medical purposes with which human lives are involved.) External protection devices such as protection equipment against excessive temperature rise, etc. must be installed, as malfunction of this product could result in serious damage to the system or injury to personnel. Also proper periodic maintenance is required. This instrument must be used under the conditions and environment described in this manual. Shinko Technos Co., Ltd. does not accept liability for any injury, loss of life or damage occurring due to the instrument being used under conditions not otherwise stated in this manual. Caution with respect to Export Trade Control Ordinance To avoid this instrument from being used as a component in, or as being utilized in the manufacture of weapons of mass destruction (i.e. military applications, military equipment, etc.), please investigate the end users and the final use of this instrument. In the case of resale, ensure that this instrument is not illegally exported. 1. Model 1.1 Model G C S /, Series name: GCS-00 (W8 x H8 x D9.5mm) Control action PID 0 No alarm action 1 (A1) A action applied (Selectable by key operation) R Relay contact: 1a Control output (OUT) S Non-contact voltage (for SSR drive): 12 +2 0V DC A DC current: to 20mA DC E Thermocouple: K, J, E Input R RTD: Pt100, JPt100 M Multi-range input A2 2 (A2) W( 5A) CT rated current: 5A W(10A) Heater burnout CT rated current: 10A W(20A) alarm CT rated current: 20A W(50A) CT rated current: 50A C5 Serial communication RS-85 SM Set value memory external selection Option Multi-range input MR This option is applicable for the thermocouple and RTD input types. For the multi-range input type, this is standard. LA Loop break alarm BK Color: Black BL Screw type mounting brackets IP Dust-proof/Drip-proof (IP5) TC Terminal cover

1.2 How to read the model label Model labels are attached to the right side of the case and the bottom of the internal assembly. GCS A R/E W(20A) BK No. (1): Model (2): Option codes (): Serial number (Indicated only on the internal assembly) 2. Name and functions of the sections Displays and indicators (1) PV display: Indicates the PV (Process variable) or setting (1) (2) (1) (2) () (8) (9) (10) (11) (Fig. 2-1) characters with a red LED. (2) display: Indicates the (Desired value) or each set value with a green LED. () AT indicator Flashes while the Auto-tuning or Auto-reset is performing. () OUT: Control output (OUT) indicator The green LED lights when the control output (OUT) is. (5) A1: 1 (A1) indicator The red LED lights when 1 (A1) output is. () A2: 2 (A2) indicator (A2 option) The red LED lights when 2 (A2) output is. () HB: Heater burnout alarm indicator (including Sensor burnout alarm) (W option) The yellow LED lights when the Heater burnout alarm or Sensor burnout alarm output is. Key operations (8) Increase key : Increases the numeric value or selects the set value. (9) Decrease key : Decreases the numeric value or selects the set value. (10) Mode key : Selects the setting mode or registers the set value by pressing this key. (11) OUT/ key: Turns the control output or.. Mounting.1 Site selection () () (5) () () Relay contact output/thermocouple input Heater burnout alarm output [The specified current value is entered in ( ).] Color black Caution Use within the following temperature and humidity ranges. Temperature: 0 to 50 (2 to 122 ), Humidity: 5 to 85%RH (No icing or condensation) Take note that ambient temperature of this unit as well as the control panel must not exceed 50 (122 ) when mounted through the control panel. Otherwise the life of electronic components (especially electrolytic capacitor) may be shortened. This instrument is intended to be used under the following environmental conditions (IEC1010-1): Overvoltage category, Pollution degree 2 Ensure the mounting location corresponds to the following conditions: (1) A minimum of dust, and an absence of corrosive gases (2) No flammable, explosive gases () No mechanical vibrations or shocks () No exposure to direct sunlight, an ambient temperature of 0 to 50 (2 to 122 ) that does not change rapidly, and without icing (5) An ambient non-condensing humidity of 5 to 85%RH () The controller away from large capacity electromagnetic switches or cables through which large current flows () No water, oil or chemicals or where the vapors of these substances can come into direct contact with the controller 2

.2 External dimensions (Unit: mm) When one-touch type mounting brackets are used 8 10 9.5 (Fig..2-1) When screw type mounting brackets are used (BL option).5 59..5 2 8 10 9.5. Panel cutout (Unit: mm) (Fig..2-2) 5 5 +0.5 0 5 +0.5 0 nx8- +0.5 0 Lateral close mounting n: Number of units mounted 5 +0.5 (Fig..-1) 0. Current transformer (CT) dimensions (Unit: mm) CTL--S (for 20A) CTL-12-S-10L1U (for 50A) (Fig..-1)

.5 Mounting Notice As the case is made of resin, do not use excessive force while screwing in the mounting bracket. The torque is approximately 0.12N m. When the one-touch type mounting brackets are used: Mountable panel thickness is 1 to mm. Set the mounting bracket 1 to the top and bottom of the instrument first. Then, insert the GCS-00 2 from the front of the mounting panel. When the Soft-type Front-cover is used, mountable panel thickness is 1 to 2.5mm. 2 1 UP When the screw type mounting brackets (BL option) are used: Mountable panel thickness is 1 to 15mm. Insert the GCS-00 from the front of the panel. Attach the mounting bracket by the holes at the top and bottom of the case, and secure the unit in place with the screws. When the Soft-type Front-cover (FS-8-S) is used, mountable panel thickness is 1 to 1.5mm. (Fig..5-1) 1 Up Up (Fig..5-2). Terminal arrangement Warning Turn the power supply to the instrument before wiring or checking. Working or touching the terminal with the power switched may result in severe injury or death due to Electric Shock. 100 to 20V AC or 2V AC/DC 1 2 5 + - A1 A2,LA or W CT input SM 11 12 1 1 15 (Fig. -1) RS-85 YA(-) YB(+) COM R/ + 8 9 10 - TC A B B + S/ or A/ - 8 9 10 RTD R/ : Relay contact output S/ : Non-contact voltage output A/ : DC current output A1 : 1 (A1) A2 : 2 (A2) W : Heater burnout alarm LA SM : Loop break alarm : Set value memory external selection RS-85 : Serial communication Dotted lines show options.

Notice The terminal block of the GCS-00 is designed to be wired from the left side. The lead wire must be inserted from the left side of the terminal, and fastened with the terminal screw. Use a thermocouple and compensating lead wire in accordance with the input specifications of this controller. Use a -wire RTD according to the input specifications of this controller. This controller does not have a built-in power switch or fuse. Therefore, it is necessary to install them in the circuit near the external controller. (Recommended fuse: Time-lag fuse, rated voltage 250V, rated current 2A) For a 2V AC/DC power source, do not confuse polarity when using direct current (DC). With the relay contact output type, externally use an auxiliary electromagnetic switch in accordance with the capacity of the load to protect the built-in relay contact. When wiring, keep input wires (thermocouple, RTD, etc.) away from AC sources and load wires to avoid external interference. Solderless terminal Use a solderless terminal with an insulation sleeve in which an M screw fits as shown below. Solderless terminal Manufacturer Model Tightening torque Y type Round type 5.8mm or less Nichifu Terminal Industries CO., LTD. Japan Solderless Terminal MFG CO., LTD. Nichifu Terminal Industries CO., LTD. Japan Solderless Terminal MFG CO., LTD..2mm Option: Heater burnout alarm output (1) This alarm is not usable for detecting current under phase control. (2) Use the current transformer (CT) provided, and pass one lead wire of the heater circuit into the hole of the CT. () When wiring, keep the CT wire away from any AC sources or load wires to avoid the external interference. 5. Operations 5.8mm or less TMEV1.25Y- VD1.25-BA TMEV1.25- V1.25-.2mm 0.N m, Max. 1.0N m (Fig. -) After the power is turned on, the PV display indicates the sensor characters and temperature unit, and the display indicates the input range high limit value for approx. 2 seconds. See (Table 5-1). (When any other value has been set during the high limit setting, the display indicates the value.) During this time, all outputs and LED indicators are in status. Control will then start indicating the PV (process variable) on the PV display and (desired value) on the display. (When the control output function is working, is indicated on the PV display. To release the control output function, press the key for approx. 1 second.) (Table 5-1) Input K K J E Pt100 JPt100 (Fig. -2) PV PV CT Heater 11 CT input 12 terminals Power source K (0 to 00 ) type is not available for the MR option. 5

5.1 Operation flowchart PV/ display mode (Approx. 1sec) Control output function Output MV (manipulated variable) indication (Approx. sec) + + (Approx. sec) + + (Approx. sec) Main setting mode] [Sub setting mode] [Auxiliary function setting mode 1] [Auxiliary function setting mode 2] 1 AT Perform/Cancel or Set value lock Input type Auto-reset Perform 2 Proportional band high limit PV filter time constant Integral time low limit OUT high limit Derivative time Sensor correction OUT low limit Proportional cycle Instrument number OUT / action hysteresis 1 (A1) value Communication speed 1 (A1) type 2 (A2) value 2 (A2) type Heater burnout alarm value 1 (A1) Energized/ Deenergized Loop break alarm time 2 (A2) Energized/ Deenergized Loop break alarm span 1 (A1) hysteresis 2 (A2) hysteresis 1 (A1) action delayed timer 2 (A2) action delayed timer setting : The items with dotted lines are optional and they appear only when the options are added. Direct/Reverse control action Auto-tuning bias + : Press the key while holding down the key. + (Approx. sec): Press the key for seconds while holding down the key. + + (Approx. sec): Press the key for seconds while holding down the and keys. If the key is pressed for approx. sec, the controller reverts to the PV/ display mode from any mode.

5.2 Main setting mode Character Name, Description, Setting range Default 1 0 ( ) Sets the 1 (Desired value 1). Setting range: low limit to high limit 2 Sets the 2 (Desired value 2). Available only when the SM option is applied. Setting range: low limit to high limit 0 ( ) 5. Sub setting mode Character Name, Description, Setting range Default Auto-tuning Perform/Cancel, or Auto-reset Perform Selects auto-tuning perform/cancel, or auto-reset perform. Auto-reset will be cancelled in approx. minutes automatically. / : Auto-tuning/Auto-reset Cancel / : Auto-tuning/Auto-reset Perform Proportional band value setting Sets the proportional band for the control output (OUT). / action when set to 0 or 0.0. Setting range: 0 to 999 ( ), or 0.0 to 99.9 Integral time setting Sets the integral time for the control output (OUT). Setting the value to 0 disables the function. With PD action ( I value is set to 0), auto-reset can be performed. Setting range: 0 to 999 seconds Derivative time setting Sets the derivative time for the control output (OUT). Setting the value to 0 disables the function. Setting range: 0 to 00 seconds Proportional cycle setting Sets the proportional cycle value for the control output (OUT). Not available for / action or current output type. Setting range: 1 to 120 seconds 1 (A1) value Sets the action point for 1 (A1) output. Not available for the GCS-0 type. Setting the value to 0 or 0.0 disables the function (except Process high and Process low alarm). Not available if No alarm action is selected during 1 (A1) type selection. Setting range: See (Table 5.-1). 2 (A2) value Sets the action point for 2 (A2) output. Setting the value to 0 or 0.0 disables the function (except Process high and Process low alarm). Not available if A2 option is not applied, or No alarm action is selected during 2 (A2) type selection. Setting range: See (Table 5.-1). Heater burnout alarm setting Sets the heater current value for Heater burnout alarm. Available only when the W option is applied. Upon returning to set limits, the alarm will stop. Rated current 5A: 0.0 to 5.0A Rated current 10A: 0.0 to 10.0A Rated current 20A: 0.0 to 20.0A Rated current 50A: 0.0 to 50.0A Loop break alarm time setting Sets the time to assess the Loop break alarm. Available only when the LA option is applied. Setting range: 0 to 200 minutes Loop break alarm span setting Sets the temperature span to assess the Loop break alarm. Available only when the LA option is applied. Setting range: 0 to 150 ( ) 10 (20 ) 200sec 50sec R S :0sec :sec 0 ( ) 0 ( ) 0.0A 0 min. 0 ( )

(Table 5.-1) type Setting range Setting range (with a decimal point) High limit alarm -199 to Input range high limit value ( ) -19.9 to 99.9 Low limit alarm -199 to Input range high limit value ( ) -19.9 to 99.9 High/Low limits alarm (0 to Input range high limit value) ( ) (0.0 to 99.9) High/Low limit range (0 to Input range high limit value) ( ) (0.0 to 99.9) Process high alarm Input range low limit value to Input range high limit value Input range low limit value to Input range high limit value Process low alarm Input range low limit value to Input range high limit value Input range low limit value to Input range high limit value High limit with standby -199 to Input range high limit value ( ) -19.9 to 99.9 Low limit with standby -199 to Input range high limit value ( ) -19.9 to 99.9 High/Low limits with standby (0 to Input range high limit value) ( ) (0.0 to 99.9) 5. Auxiliary function setting mode 1 Character Name, Description, Setting range Default Set value lock Locks the set value to prevent setting errors. The setting item to be locked differs depending on the selection. PID auto-tuning or auto-reset will not function if Lock 1 or Lock 2 is selected. (Unlock): All set values can be changed. (Lock 1): None of the set values can be changed. (Lock 2): Only (desired value) can be changed. (Lock ): All set values can be changed. However, they return to their previous value after the power is turned off because they are not saved in the non-volatile memory. Do not change any setting item in Auxiliary function Setting mode 2. If any item in the mode is changed, it will affect other setting items such as the and value. Be sure to select Lock when changing the set value frequently via communication function. (If the value set by the communication function is the same as the value before the setting, the value will not be written in the Unlock non-volatile memory.) high limit setting Sets the high limit value. Setting range: low limit to Input range high limit value low limit setting Sets the low limit value. Setting range: Input range low limit value to high limit Sensor correction setting Sets sensor correction value of the sensor. Setting range: -199 to 200 ( ), or -19.9 to 20.0 Instrument number setting Sets the instrument number individually to each instrument when communicating by connecting multiple instruments in serial communication. Available only when the C5 option is applied. Setting range: 0 to 95 Communication speed selection Selects the communication speed equal to that of the host computer. Available only when the C5 option is applied. : 200bps : 800bps : 900bps : 19200bps 8 Input range high limit value Input range low limit value 0 ( ) or 0.0 0 900bps

5.5 Auxiliary function setting mode 2 Character Name, Description, Setting range Default Input type selection For the multi-range input type (MR option), one input type can be selected from thermocouple ( types) and RTD (2 types), and the unit K (0 to 999 ) or can be selected as well. However, K (0 to 00 ) type is not usable. The following ranges can be selected when the MR option is applied to the thermocouple or RTD input type. : K 0 to 999 : J 0 to 999 : E 0 to 00 : Pt100-199 to 00 : JPt100-199 to 00 : Pt100-19.9 to 99.9 : JPt100-19.9 to 99.9 : K 0 to 999 : J 0 to 999 : E 0 to 999 : Pt100-199 to 999 : JPt100-199 to 999 PV filter time constant setting 0.0sec Sets PV filter time constant value. If the value is set too large, it affects control result due to the delay of response. Setting range: 0.0 to 10.0 seconds OUT high limit setting 100% Sets the control output (OUT) high limit value. Not available for / action. Setting range: OUT low limit value to 100% (DC current output type: OUT low limit value to 105%) OUT low limit setting 0% Sets the control output (OUT) low limit value. Not available for / action. Setting range: 0% to OUT high limit value (DC current output type: -5% to OUT high limit value) OUT / action hysteresis setting 1.0 Sets the / action hysteresis for the control output (OUT). Available only for / action. Setting range: 0.1 to 99.9 1 (A1) type selection Selects 1 (A1) type. Not available for the GCS-0 type. : No alarm action : High limit alarm : Low limit alarm : High/Low limits alarm : High/Low limit range alarm : Process high alarm : Process low alarm : High limit alarm with standby : Low limit alarm with standby : High/Low limits alarm with standby 2 (A2) type selection Selects 2 (A2) type. Available only when the A2 option is applied. types are the same as those of 1 (A1). 9 No alarm action No alarm action

1 (A1) Energized/Deenergized selection Selects 1 (A1) output Energized or Deenergized. Not available for the GCS-0 type. Not available if No alarm action is selected during 1 (A1) type selection. : Energized : Deenergized 2 (A2) Energized/Deenergized selection Selects 2 (A2) Energized or Deenergized. Not available if the A2 option is not applied, or if No alarm action is selected during 2 (A2) type selection. Selection items are the same as those of 1 (A1) Energized/ Deenergized selection. 1 (A1) hysteresis setting Sets hysteresis value for 1 (A1) output. Not available for the GCS-0 type. Not available if No alarm action is selected during 1 (A1) type selection. Setting range: 0.1 to 99.9 ( ) 2 (A2) hysteresis setting Sets hysteresis value for 2 (A2) output. Not available if A2 option is not applied, or if No alarm action is selected during 2 (A2) type selection. Setting range: 0.1 to 99.9 ( ) 1 (A1) action delayed timer setting Sets 1 (A1) action delayed timer. The alarm is activated when the setting time has passed after the input enters alarm output range. Not available for the GCS-0 type. Not available if No alarm action is selected during 1 (A1) type selection. Setting range: 0 to 999 seconds 2 (A2) action delayed timer setting Sets 2 (A2) action delayed timer. The alarm is activated when the setting time has passed after the input enters alarm output range. Not available if A2 option is not applied, or if No alarm action is selected during 2 (A2) type selection. Setting range: 0 to 999 seconds Direct/Reverse control action Selects Reverse (Heating) or Direct (Cooling) control action. : Reverse (Heating) action : Direct (Cooling) action Auto-tuning bias setting Sets auto-tuning bias value during PID auto-tuning. Setting range: 0 to 50 (0 to 100 ), or 0.0 to 5.0 Energized Energized 1.0 ( ) 1.0 ( ) 0sec 0sec Reverse (Heating) action 20 (0 ) Characters used in this manual Indication Number, / -1 0 1 2 5 8 9 Indication Alphabet A B C D E F G H I J K L M Indication Alphabet N O P Q R S T U V W X Y Z 10

Energized/Deenergized function [If alarm action Energized is selected] The alarm output (terminals -, or -5) is conducted () while the alarm output indicator is lit The alarm output is not conducted () while the alarm output indicator is not lit. [If alarm action Deenergized is selected] The alarm output (terminals -, or -5) is not conducted () while the alarm output indicator is lit. The alarm output is conducted () while the alarm output indicator is not lit. setting setting (High limit alarm Energized) (High limit alarm Deenergized) (Fig. 5.5-1) (Fig. 5.5-2) Set value memory external selection (SM option) If the SM option is applied, the 1 or 2 can be selected by external contact. Terminals between 1 and 1 Open : 1 Terminals between 1 and 1 Closed : 2 However, the 1 or 2 cannot be changed during setting mode or PID auto-tuning. 5. Control output function Character Name, Description Control output function This is a function to pause the control action or turn the control output of the unused instrument of the plural units even if the power to the instrument is supplied. is indicated on the PV display while the function is working. This function can be selected from any mode or from any setting item by pressing the key for approx. 1 second. Once this function is enabled, the function cannot be released even if the power to the instrument is turned off and on again. To cancel the function, press the key again for approx. 1 second. 5. Output MV (manipulated variable) indication Name, Description Output MV (manipulated variable) indication Press the key for seconds on the PV/ display mode. The main setting mode appears during the process, however, if the key is pressed continuously, the output MV is indicated on the display, and the decimal point flashes every 0.5 seconds. By pressing the key again, the unit reverts to the PV/ display mode. 11

. Running After the unit is mounted to the control panel and wiring is completed, operate the unit following the procedures below. (1) Turn the power supply to the GCS-00. For approx. 2 seconds after the power on, the sensor type characters and temperature unit are indicated on the PV display, and the input range high limit value is indicated on the display. See (Table.1-1). (If any other value is set during the high limit setting, display indicates the value.) During this time, all outputs and LED indicators are in status. After that, the PV display indicates the current temperature, and the display indicates the (desired value). While the Control output function is working, is indicated on the PV display. (2) Input each set value. Input each set value referring to Chapter 5 Operations. () Turn the load circuit power. Control action starts so as to maintain the control target at the.. Other functions (1) Input abnormality indication When the input value exceeds 999 (99.9), digits on the PV display flash. When the input value exceeds [Input range high limit value + 50 (100 )], the control output is turned (for DC current output type, OUT low limit value), and the PV display flashes. When the input falls below -199 (-19.9), digits on the PV display flash. When the thermocouple input value falls below -50 (-100 ), the control output is turned (for DC current output type, OUT low limit value), and the PV display flashes. For the RTD input, when Input range low limit value is -19.9, if the input value falls below -50 (-100 ), the control output is turned (for the current output type, OUT low limit value), and the PV display flashes. For the RTD input, when Input range low limit value is -199, if the input value falls below [-199 1% of the input span], the control output is turned (for DC current output type, OUT low limit value), and the PV display flashes. (2) Sensor burnout (Burnout) When the thermocouple or RTD is burnt out, the control output is turned (for DC current output type, OUT low limit value), and the PV display flashes. () Self-diagnosis The CPU is monitored by a watchdog timer, and when an abnormal status is found on the CPU, the controller is switched to warm-up status. () Automatic cold junction temperature compensation (thermocouple input type) This detects the temperature at the connection terminal between thermocouple and the instrument, and always keeps it at the same status as when the reference junction is located at 0 (2 ). 12

8. Action explanation 8.1 Standard control action Heating (Reverse) action Cooling (Direct) action Control action Proportional band Proportional band setting setting Relay contact output Non-contact voltage output DC current output Cycle action is performed according to deviation Cycle action is performed according to deviation + + + + + + 12V DC 12/0V DC 0V DC 0V DC 0/12V DC 12V DC Cycle action is performed according to deviation Cycle action is performed according to deviation + + + + + + 20mA DC 20 to ma DC ma DC ma DC to 20mA DC 20mA DC Indicator (OUT) Green Changes continuously according to deviation Lit Changes continuously according to deviation Lit : Acts or. 8.2 / action Heating (Reverse) action Cooling (Direct)action Control action setting setting Relay contact output Non-contact voltage output + 12V DC + 0V DC + 0V DC + 12V DC DC current output + + 20mA DC ma DC + ma DC + 20mA DC Indicator (OUT) Green Lit Lit : Acts or. 1

8. action High limit alarm Low limit alarm High/Low limits alarm action setting setting setting Output Indicator Lit Lit Lit Lit High/Low limit range alarm Process high alarm Process low alarm action setting Output Indicator Lit Lit Lit High limit alarm with standby Low limit alarm with standby High/Low limits alarm with standby action setting setting setting Output Indicator Lit Lit Lit Lit : Acts or. : The standby functions. Use terminals and 5 for 2 (A2). 8. Heater burnout alarm action Heater burnout alarm action action Small Heater burnout alarm setpoint Load current Large Output 5 5 Indicator Lit 1

9. PID auto-tuning In order to set each value of P, I, D and ARW automatically, the auto-tuning process should be made to fluctuate to obtain an optimal value. Note: Sometimes the auto-tuning process will not fluctuate if auto-tuning is performed at or near room temperature. Therefore auto-tuning might not finish normally. In the case of a large difference between the and processing temperature as the temperature is rising When AT bias is set to 20, the AT process will fluctuate at the temperature 20 lower than the. Temperature Temperature 20 lower than the () (1) Calculating PID constant (2) PID constant calculated () Controlled by the PID constant set by auto-tuning. () AT bias value AT starting point Time (1) (2) () (Fig. 9-1) In the case of a stable control The AT process will fluctuate around the. Temperature (1) Calculating PID constant (2) PID constant calculated () Controlled by the PID constant set by auto-tuning. AT starting point Time (1) (2) () (Fig. 9-2) In the case of a large difference between the and processing temperature as the temperature is falling When AT bias is set to 20, the AT process will fluctuate at the temperature 20 higher than the. Temperature 20 higher than the Temperature () (1) Calculating PID constant (2) PID constant calculated () Controlled by the PID constant set by auto-tuning. () AT bias value AT starting point Time (1) (2) () (Fig. 9-) 15

10. Specifications 10.1 Standard specifications Mounting : Flush Setting : Input system using membrane sheet key Display PV display : Red LED display digits, size, 10(H) x 5.5(W) mm display : Green LED display digits, size, 8(H) x (W) mm Accuracy (Setting and Indication) Thermocouple : Within 0.% of each input span 1digit, or within 2 ( ), whichever is greater RTD : Within 0.2% of each input span 1digit, or within 1 (2 ), whichever is greater Input sampling period: 0.25 seconds Input Thermocouple RTD Control output (OUT) Relay contact 1 2 COM A1 Power source 1 (A1) : K, J, E External resistance, 100 or less When input is burnt out: Overscale : Pt100, JPt100 -wire system Allowable input lead wire resistance, 10 or less per wire When input is burnt out: Overscale : 1a Control capacity, A 250V AC (resistive load) 1A 250V AC (inductive load cosø=0.) Non-contact voltage : For SSR drive 12 +2 0V DC Maximum 0mA (short circuit protected) Current 1 (A1) output Action Output If Shinko SSR (SA-00 series) is used, units are connectable in parallel. : to 20mA DC Load resistance, maximum 550 : / action, 0.1 to 99.9 ( ) : Relay contact, 1a Control capacity, A 250V AC (resistive load) 1A 250V AC (inductive load cosø=0.) Control action PID action (with auto-tuning function) PD action (with auto-reset function) (When integral time is set to 0.) P action (with auto-reset function) (When Integral time and Derivative time are set to 0.) / action (When proportional band value is set to 0 or 0.0.) Proportional band : 0 to 999 ( ) or 0.0 to 99.9 (/ action when set to 0 or 0.0) Integral time : 0 to 999sec (off when set to 0) Derivative time : 0 to 00sec (off when set to 0) Proportional cycle : 1 to 120sec (not available for DC current output type) ARW : Automatic : 0.1 to 99.9 ( ) Output limit : 0 to 100% ( 5 to 105% for DC current output type) Circuit insulation configuration Insulated 1 1 15 Serial communication 1 Set value memory (external selection) 1 11 CT input CPU Input 8 9 10 * Output 12 * If control output type is DC current output or Non-contact voltage output, Output is not insulated from Input, and Output is not insulated from CT input. A2 5 2 (A2) or Heater burnout alarm 1

Insulation resistance 10M or more, at 500V DC In the case of the above circuit insulation configuration (*), the resistance insulation test must not be carried out between Output and Input, and between Output and CT input, because Output is not insulated from Input, and Output is not insulated from CT input. Dielectric strength Between input terminal and ground -------------------------- 1.5kV AC for 1 minute Between input terminal and power terminal ---------------- 1.5kV AC for 1 minute Between output terminal and ground ------------------------ 1.5kV AC for 1 minute Between output terminal and power terminal -------------- 1.5kV AC for 1 minute Between power terminal and ground ------------------------- 1.5kV AC for 1 minute Power supply voltage : 100 to 20V AC, 50/0Hz, 2V AC/DC, 50/0Hz Allowable voltage fluctuation: 100 to 20V AC: 85 to 2V AC 2V AC/DC : 20 to 28V AC/DC Power consumption : Approx. 8VA Ambient temperature : 0 to 50 (2 to 122 ) Ambient humidity : 5 to 85%RH (non-condensing) Weight : Approx. 10g External dimensions : 8 x 8 x 9.5mm (W x H x D) Material : Flame-resistant resin (case) Color : Light gray (case) Attached functions : Control output function Set value lock Sensor correction Power failure countermeasure Self-diagnosis Automatic cold junction temperature compensation Sensor burnout Input abnormality indication Accessories : One-touch type mounting brackets 1 set (When the BL option is applied, Screw type mounting brackets 1 set) Instruction manual 1 copy Terminal cover 1 piece (when TC option is applied) CT (Current transformer) 1 piece CTL-S : When W (5A, 10A, 20A) option is applied CTL-12-S-10L1U : When W (50A) option is applied 10.2 Optional specifications 2 (A2) output [Option code: A2] The SM or W option cannot be applied in conjunction with this option. 2 (A2) and LA option utilize common output terminals. Action : / action, 0.1 to 99.9 ( ) Output : Relay contact, 1a Control capacity, A 250V AC (resistive load) 1A 250V AC (inductive load cosø =0.) Heater burnout alarm output (including sensor burnout alarm) [Option code: W] Watches the heater current with CT (current transformer), and detects the burnout. The A2, SM or C5 option cannot be applied in conjunction with this option. This option cannot be applied to the current output type. Rating : 5A [W(5A) option], 10A [W(10A) option], 20A [W(20A) option], 50A [W(50A) option] (Must be specified) Setting range : 5A [W(5A)], 0.0 to 5.0A (off when set to 0.0) 10A [W(10A)], 0.0 to 10.0A (off when set to 0.0) 20A [W(20A)], 0.0 to 20.0A (off when set to 0.0) 50A [W(50A)], 0.0 to 50.0A (off when set to 0.0) 1

Setting accuracy: Within 5% of the rated value Action : / action Output : Relay contact, 1a Control capacity, A 250V AC (resistive load) 1A 250V AC (inductive load cosø =0.) Serial communication [Option code: C5] The SM, LA or W option cannot be applied in conjunction with this option. The following operations can be executed from the external computer. (1) Reading and setting of the, PID values and various set values (2) Reading of the input value and action status () Change of the functions Communication line : EIA RS-85 Communication method : Half-duplex communication start-stop synchronization Communication speed : 200, 800, 900 and 19200bps (selectable by keypad) Data format : Start bit 1 Data bit Parity Even Stop bit 1 Digital external setting : Receives digital set values from the PC-900 with the TC option. The Set value lock of the GCS should be set to Lock. Set value memory external selection [Option code: SM] 1 or 2 can be selected by external contact. The A2, C5, LA or W option cannot be applied in conjunction with this option. Terminals between 1 and 1 Open : 1 Terminals between 1 and 1 Closed : 2 Multi-range input [Option code: MR] Thermocouple K (0 to 00 ) type is not available for the MR option. Sensor: Thermocouple (K, J, E), RTD (Pt100, JPt100) Temperature unit: or Loop break alarm [Option code: LA] The alarm will be activated when the PV (process variable) does not rise as much as the span or more within the time it takes to assess the loop break alarm after the MV (manipulated variable) has reached 100% or the output high limit value. The alarm will also be activated when the PV (process variable) does not fall as much as the span or more within the time it takes to assess the loop break alarm after the MV (manipulated variable) has reached 0% or the output low limit value. This detects heater burnout, sensor burnout and actuator trouble. The C5, SM or W option cannot be applied in conjunction with this option. LA and 2 (A2) option utilize common output terminals. Setting range: Loop break alarm time: 0 to 200 minutes Loop break alarm span: 0 to 150 ( ) Output: Relay contact, 1a Control capacity, A 250V AC (resistive load), 1A 250V AC (inductive load, cosø=0.) Color black [Option code: BK] Front panel : Dark gray Base and case : Black Screw type mounting bracket [Option code: BL] Mountable panel thickness: 1 to 15mm Dust-proof/Drip-proof [Option code: IP] Dust-proof and Drip-proof specification (IP5) Effective only for panel surface, case part is excluded. The Front cover (soft type, sold separately) is recommended to strengthen the Dust-proof/Drip-proof specification. To protect the controller from water leak between the control panel and controller, the control panel surface to be mounted should be vertical. Terminal cover [Option code: TC] Electrical shock protection terminal cover 18

Designated specifications Input, scale range : Shipped as specified input and scale range type : Shipped as specified alarm type Control action : Shipped as specified control action (e.g. Shipped as PD action) : Shipped as specified hysteresis Cooling (Direct) action : Shipped as Cooling (Direct) action 11. Troubleshooting If any malfunctions occur, refer to the following items after checking the power supply and wiring. 11.1 Indication Problem is indicated on the PV display. is flashing on the PV display. is flashing on the PV display. The indication of the PV display is abnormal or unstable. Presumed cause and solution Control output function is working. To release the function, press the key for approx. 1 second. Thermocouple or RTD is burnt out. [Thermocouple] If the input terminals of the instrument are shorted, and if a value around room temperature is indicated, the instrument is likely to be operating normally, however, the sensor may be burnt out. [RTD] If approximate 100 of resistance is connected to the input terminals between A-B of the instrument and between B-B are shorted, and if a value around 0 (2 ) is indicated, the instrument is likely to be operating normally, however, the sensor may be burnt out. Check whether the lead wire of thermocouple or RTD is securely connected to the instrument terminal. Check whether the polarity of thermocouple or compensating lead wire is correct. Check whether codes (A, B, B) of RTD agree with the instrument terminals. Check whether the sensor input is selected properly. Check whether the temperature unit ( or ) is correct. Check whether the sensor correction value is suitable. Check whether the specification of the thermocouple or RTD is correct. AC leaks into the thermocouple or RTD circuit. There may be equipment that interferes with or makes noise near the controller. 11.2 Key operation Problem Unable to set the, P, I, D, proportional cycle, alarm value, etc. The values do not change by the or key. The setting indication does not change within the input range even if the or key is pressed, and new values are unable to be set. Presumed cause and solution Set value lock (Lock 1 or Lock 2) has been selected. Release the lock mode. PID auto-tuning or auto-reset is performing. In the case of PID auto-tuning, cancel auto-tuning. In the case of Auto-reset, it takes approximate minutes until the auto-reset is finished. high limit or low limit may be set at the point where the value does not change. Set it to a suitable value while in Auxiliary function setting mode 1. 19

11. Control Problem The PV (process variable) does not rise. The control output remains in an status. The control output remains in an status. Presumed cause and solution Check whether thermocouple or RTD is burnt out. Check whether the lead wire of thermocouple or RTD is securely connected to the instrument terminals. Check whether the wiring of output terminals is correct. OUT low limit value is set to 100% or higher in Auxiliary function setting mode 2. Set it to a suitable value. OUT high limit value is set to 0% or less in Auxiliary function setting mode 2. Set it to a suitable value. For all other malfunctions, please contact our main office or dealers. Reg. Office URL E-mail SHINKO TECHNOS CO.,LTD. OVERSEAS DIVISI : 2-5-1, Senbahigashi, Minoo, Osaka, Japan : http://www.shinko-technos.co.jp : overseas@shinko-technos.co.jp 20 Tel : Fax: 81-2-2-100 81-2-2-00