T9MPV SmartComfort VS90 Product Specifications

Similar documents
T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Cooling Capacity CFM in. w.c. (125 Pa)

Wt. Lbs Model Number (BTUH) Hz

Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended (order separately)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM range

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0201CW Recommended (sold separately)

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Multi-Position Gas Furnaces

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Ruud Achiever Plus Series Multi-position Gas Furnaces

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

MULTI POSITION GAS FURNACE

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

MULTI POSITION GAS FURNACE

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Rheem Classic Series Multi-position Gas Furnaces

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

TECHNICAL SPECIFICATIONS

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

TECHNICAL SPECIFICATIONS

Rheem Classic Plus Series Multi position Gas Furnaces

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

G6RC Series TECHNICAL SPECIFICATIONS

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

TECHNICAL SPECIFICATIONS

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Ruud Achiever Series Multi position Gas Furnaces

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Multi-Position Gas Furnaces

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

RG7D 1-Stage Heat Series

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Energy Saving. Space Saving.

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITION GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

GAS FURNACES. Visit taxcredit for complete details.

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

GMS9/GCS9 SERIES 93% AFUE

Comfort, Quality and Efficiency.

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

Downflow/Horizontal Right Induced Draft Gas Furnace

Transcription:

90+ Variable Speed Two -Stage Heating Furnace FLEXIBILITY Supports two--stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40 high with wider cabinets, for ease of installation Factory shipped for natural gas, with Propane Gas conversion kits available Four position -- upflow/downflow/horizontal installation Vent pipe can be run horizontally or vertically Internal condensate drain system SERVICE Self diagnostics Entire blower assembly removable COMFORT Adjustable timed blower heating Off Adjustable timed blower cooling On/Off Thermal lined, one piece steel cabinet for noise reduction Insulated blower compartment 24 and 115VAC humidifier terminals Electronic air cleaner terminal Dehumidification option EFFICIENCY 92.1% AFUE Two--stage operation BPM Variable speed DC motor Two--stage Induced draft blower In--shot burners QUALITY RPJ III Stainless steel heat exchanger Stainless steel secondary heat exchanger High temperature limit control prevents overheating Direct ignition with Silicon Nitride igniton Flame roll--out sensors standard External filter rack with permanent filters Stainless steel solid doors 10 year No Hassle Replacement limited warranty 7 year limited parts warranty Limited lifetime warranty on heat exchanger T9MPV SmartComfort VS90 Product Specifications Illustrations and photographs are only representative. Some product models may vary.! WARNING This furnace is not designed for use in mobile homes, trailers, or recreational vehicles. Such use could result in property damage and/or death. THIS MODEL 92.1 Model Number UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Dimensions HxWxD(In.) Input (MBTUH) Efficiency AFUE Cooling Capacity. @.5 in wc T9MPV050F12D 40 x 19 1 / 8 x29 50 92.1 1.5-3.0 TON T9MPV075F12D 40 x 19 1 / 8 x29 75 92.1 1.5-3.5 TON T9MPV100J20D 40 x 22 3 / 4 x29 100 92.1 3-5.0TON T9MPV125L20D 40 x 24 1 / 2 x29 125 92.1 3-5.0TON Specifications are subject to change without notice 440 21 2023 03 August 7

FURNACE SPECIFICATIONS Model Number *9MPV050F12 *9MPV075F12 *9MPV100J20 *9MPV125L20 INPUT HIGH HEAT(BTUH) LOW HEAT (BTUH) HTG. CAP. HIGH HEAT (BTUH) LOW HEAT (BTUH) 50,000 35,000 46,000 32,000 75,000 52,500 100,000 70,000 AFUE % (ICS) 92.1 92.1 92.1 92.1 TEMP. RISE RANGE High Heat ( o F/ o C) Low Heat ( o F/ o C) 35--65/19--36 35--65/19--36 70,000 48,000 40--70/22--39 40--70/22--39 93,000 65,000 40--70/22--39 40--70/22--39 125,000 87,500 118,000 82,000 40--70/22--39 40--70/22--39 VENT SIZE^ 2 OD 2 -- 3 OD 3 OD 3 OD VOLTS/HZ/PH 115/60/1 115/60/1 115/60/1 115/60/1 RATING PLATE AMPS. 9.5 11.4 14.6 15.4 MIN./MAX. VOLTAGE 104/127 104/127 104/127 104/127 TRANSFORMER (V.A.) 40 40 40 40 GAS PIPE SIZE (IN.) 1/2 1/2 1/2 1/2 COOLING CAP. (TONS) 3.0 3.0 5.0 5.0 HIGH ALTITUDE PRESSURE SWITCH 1013165 1013165 1013165 1013157 FILTER SIZE (IN.) 16X25X1(1) 16X25X1(1) 16X25X1(2) 16X25X1(2) DIMENSIONS (in.) WIDTH X DEPTH X HEIGHT 19 1 / 8 x29x40 19 1 / 8 x29x40 22 3 / 4 x29x40 24 1 / 2 x29x40 WEIGHT (Lbs.) 150 168 187 203 ^ Vent size may vary depending on length, number of elbows, standard vent or direct vent. See Installation Instructions. * Denotes Brand (C, H, T) Cabinet to Combustible Clearances TOP BOT. RH LH BACK FRNT FLUE 1 0 0 0 0 3 0 DIMENSIONS Unit Cabinet Bottom Top Capacity A B C D E *9MPV050F12 19 1 / 8 17 5 / 8 14 3 / 4 2 1 / 2 9 1 / 2 41/ 2 *9MPV075F12 19 1 / 8 17 5 / 8 14 3 / 4 2 1 / 2 9 1 / 2 *9MPV100J20 22 3 / 4 21 1 / 4 18 3 / 4 2 5 / 8 11 3 / 8 TOP AIR INTAKE VENT A B *9MPV125L20 24 1 / 2 23 23 2 1 / 4 12 1 / 4 * Denotes Brand 4 3/ 8 D E FRONT ALL DIMENSIONS IN INCHES 1in=25.4mm LEFT SIDE 6 11 / 16 2 1 /4 131/ 4 1 7 / 8 TRAP (DOWNFLOW) VENT AIR INTAKE (ALTERNATE) GAS TRAP UPFLOW/HORIZONTAL THERMOSTAT (KO) 24 4 13 / 16 7 215 / 8 4 7 / 8 1 1 /4 ELECTRICAL 1 1 /16 1 3 / 8 28 3 / 4 13 11 / 16 17 5 / 16 29 7 /8 19 13 /16 24 1 / 16 1 11 / 16 31 11 /16 11 3 /16 33 11 /16 29 7 /8 4 5 / 16 2 3 / 8 1 1 /16 GAS 4 13 / 16 7 1 1 /16 TRAP (DOWNFLOW) ELECTRICAL AIR INTAKE (ALTERNATE) VENT 28 1 / 2 18 1 /2 RIGHT SIDE TRAP (UPFLOW/HORIZONTAL) THERMOSTAT 2 1 / 4 3 / 4 TYP. 40 19 13 / 16 27 3 /16 17 5 / 16 C BOTTOM 21 5 / 8 13 1 / 4 (KO) 111 /16 23 1/ 8 3 7 / 8 KO = Knockout 4 7 / 8 24 21 5 / 8 1 7 / 8 2

MODEL NUMBER IDENTIFICATION GUIDE * 9 MP V 075 F 12 D # Brand Identifier Engineering Rev. * = Brand Denotes minor changes Marketing Digit Model Efficiency Denotes major change 8 = Non--Condensing, 80+% Gas Furnace Cooling 9 = Condensing, 90+% Gas Furnace 08 = 800 12 = 1 Installation Configuration 14 = 1400 UP = Upflow DN = Downflow UH = Upflow/Horizontal 16 = 1600 HZ = Horizontal DH = Downflow/Horizontal 20 = 0 MP = Multiposition, Up/Down/Horizontal Cabinet Width Major Design Feature B = 15.5 Wide 1 = One (Single) Pipe N = Single Stage F = 19.1 Wide 2=TwoPipe P=PVCVent J = 22.8 Wide D = 1 or 2 Pipe T = Two Stage L = 24.5 Wide L = Low NOx V = Variable Speed Input (Nominal MBTUH) * Denotes Brand (C, H, T) ACCESSORIES Model Number Description Used With Models NAHA002NG (1172961**) NAHA002LP (1172959**) Gas Conversion Kits (2--Stage) -- Propane to natural gas conversion kit. Allows field conversion to natural gas. Gas Conversion Kits (2--Stage) -- Natural gas to Propane conversion Kit (includes low pressure switch). Allows field conversion to Propane gas. NAHA001FF Filter Kits -- External filter frame. 16 x25 Side Return (All Furnaces) NAHA001FP External filter frame. 16 x25 (Bulk Pack Kit -- Qty 10) Bottom Return (All F 19 1 / 8 Furnaces under 1600 ) NAHA002FF Filter Kits -- Bottom return filter frame kit 20 x25 NAHA002FP Bottom return filter frame kit 20 x25 (Bulk Pack Kit -- Qty 10) *9MPV *9MPV (All J 22 3 / 4 Furnaces) NAHA001TK Duct Standoff Filter Kit -- To adapt 20 x25 filter for single side return. Side Return (All single return applications with 1600 or greater) Bottom Return (All F 19 1 / 8 Furnaces under 1600 ) NAHA001NK Condensate Neutralizer Kit -- for condensing gas furnaces (612833 **) All *9MPV Furnaces if Required NAHH002SB Combustible Floor Subbase -- Subbase Furnace ONLY: All 19 1 / 4 wide furnace models *9MPV050/075 NAHH003SB NAHH010SB Combustible Floor Subbase -- Subbase Furnace ONLY: All 22 3 / 4 wide furnace models Combustible Floor Subbase -- Subbase Furnace ONLY: All 24 1 / 2 wide furnace models *9MPV100 *9MPV125 NAHH005SB Subbase -- Furnace w/19 1 / 4 cased coil *9MPV050/075 Counterflow furnace w/19 1 / 4 cased coil NAHH006SB Subbase -- Furnace w/22 3 / 4 cased coil *9MPV100 Counterflow furnace w/22 3 / 4 cased coil NAHH009SB Subbase Furnace w/24 1 / 2 cased coil *9MPV125 Counterflow furnace w/24 1 / 2 cased coil 1013165 ** High Altitude Pressure Switch Kit *9MPV050, 075 & 100 1013157 ** High Altitude Pressure Switch Kit *9MPV125 NAHA001CV (1011129 **) NAHA002CV 3 Concentric Vent Kit -- allows single wall penetration for 2 pipe direct vent applications (90+). 2 Concentric Vent Kit -- allows single wall penetration for 2 pipe direct vent applications (90+). *9MPV100/125 *9MPV050/075 NAHA001CA Coil Adapter for Downflow Furnaces All Downflow Models NAHA002WL To replace Warning Labels, Operating Instructions & Wiring Labels on *9MPV Blower Door when needed * Denotes Brand (C, H, T) ** Fast part number 3

DIP Switch 5&6 Circulation Air Blower Data - *9MPV050 Cooling Adjustment High Cool @ 0.50 in wc Low Cool (80% of High Cool) ** Adjust Jumper Setting DIP Switch 3&4 Heating Rise Adjustment High Heat @0.20inwc Low Heat at Resultant Static 00 1246 997 + 00-4 -- 3 *00 1211 969 *NOM *00 0 0 00 1122 898-00 5 5 01 1105 884 + 01 3 4 01 1027 822 NOM 01 7 7 01 945 756-01 13 14 10 892 714 + 10 -- 1 0 10 820 656 NOM 10 4 5 10 745 596-10 9 9 11 688 550 + 11 -- 15 -- 15 11 609 487 NOM 11 -- 13 -- 12 11 541 433-11 -- 9 -- 9 performance includes 1 washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 10% reduction in airflow when in Comfort position and a call for low or high cooling is present with the O line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 20% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings. Table 2 Continuous Fan @ Table 3 SW2 DIP Assignments 0.10 in wc ESP DIP Switch Blower Parameter DIP Switch 1 & 2 () 1&2 Cont Fan Adj *00 592 3&4 Heat Speed Adj 01 1021 5&6 Cool Speed Adj 10 1346 7&8 Cool On/Off Delay 11 1346 Table 4 Cooling Delay Options (SW2-7, 8) ON DELAY OFF DELAY DIP SW2-7/8 Timed ON (sec) during on Timer OFF (sec) during off *00 5 OFF 90 100% 01 5 OFF 0 OFF 10 30 50% 30 100% 11 30 50% 180 50% % is of High Cool airflow demand determined from SW2--5/6 Table 1 resumes to 100% after on time is completed stops (or switches to continuous fan speed) after off time is completed MAX s for Factory Washable Filters Dimensions () 14 x 25 1400 16 x 25 1600 20 x 25 0 24 x 25 2500 MAX based on 600 FPM Note 1: Disposable filters are typically rated at 300 FPM. These filters only allow half the airflow when compared to 600 FPM filters. (example, 20 x 25 @ 600 FPM = 0, @ 300 FPM = 1000 ) 4

Circulation Air Blower Data - *9MPV050 Cooling Settings High Cooling s *9MPV050F12 1600 1400 1 1000 800 600 400 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Low Cooling s *9MPV050F12 1 1000 800 600 400 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 5

DIP Switch 5&6 Circulation Air Blower Data - *9MPV075 Cooling Adjustment High Cool @ 0.50 in wc Low Cool (80% of High Cool) ** Adjust Jumper Setting 6 DIP Switch 3&4 Heating Rise Adjustment High Heat @0.20inwc Low Heat at Resultant Static 00 1342 1074 + 00 -- 4 -- 4 *00 1210 968 *NOM *00 0 0 00 1053 842 -- 00 5 4 01 1135 908 + 01 1 1 01 1020 816 NOM 01 6 5 01 872 698 -- 01 12 10 10 965 772 + 10 -- 1 -- 1 10 840 672 NOM 10 3 3 10 680 544 -- 10 9 8 11 708 566 + 11 -- 6 -- 6 11 590 472 NOM 11 -- 2 -- 3 11 488 390 -- 11 3 2 performance includes 1 washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 10% reduction in airflow when in Comfort position and a call for low or high cooling is present with the O line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 20% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings. Table 2 Continuous Fan @ Table 3 SW2 DIP Assignments 0.10 in wc ESP DIP Switch Blower Parameter DIP Switch 1 & 2 () 1&2 Cont Fan Adj *00 612 3&4 Heat Speed Adj 01 1096 5&6 Cool Speed Adj 10 1403 7&8 Cool On/Off Delay 11 1403 Table 4 Cooling Delay Options (SW2-7, 8) ON DELAY OFF DELAY DIP SW2-7/8 Timed ON (sec) during on Timer OFF (sec) during off *00 5 OFF 90 100% 01 5 OFF 0 OFF 10 30 50% 30 100% 11 30 50% 180 50% % is of High Cool airflow demand determined from SW2--5/6 Table 1 resumes to 100% after on time is completed stops (or switches to continuous fan speed) after off time is completed MAX s for Factory Washable Filters Dimensions () 14 x 25 1400 16 x 25 1600 20 x 25 0 24 x 25 2500 MAX based on 600 FPM Note 1: Disposable filters are typically rated at 300 FPM. These filters only allow half the airflow when compared to 600 FPM filters. (example, 20 x 25 @ 600 FPM = 0, @ 300 FPM = 1000 )

Circulation Air Blower Data - *9MPV075 Cooling Settings High Cooling s *9MPV075F12 1800 1600 1400 1 1000 800 600 400 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Low Cooling s *9MPV075F12 1400 1 1000 800 600 400 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 7

DIP Switch 5&6 Circulation Air Blower Data - *9MPV100 Cooling Adjustment High Cool @ 0.50 in wc Low Cool (80% of High Cool) ** Adjust Jumper Setting 8 DIP Switch 3&4 Heating Rise Adjustment High Heat @0.20inwc Low Heat at Resultant Static 00 2144 1715 + 00 -- 4 -- 4 *00 2013 1610 *NOM *00 0 0 00 1842 1474 -- 00 5 5 01 1772 1418 + 01 2 1 01 1624 1299 NOM 01 8 7 01 1471 1177 -- 01 14 14 10 1367 1094 + 10 0 -- 1 10 1227 982 NOM 10 6 5 10 1077 862 -- 10 13 11 11 930 744 + 11 -- 6 -- 7 11 808 646 NOM 11 -- 2 -- 2 11 634 507 -- 11 3 3 performance includes 1 washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 10% reduction in airflow when in Comfort position and a call for low or high cooling is present with the O line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 20% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings. Table 2 Continuous Fan @ Table 3 SW2 DIP Assignments 0.10 in wc ESP DIP Switch Blower Parameter DIP Switch 1 & 2 () 1&2 Cont Fan Adj *00 1007 3&4 Heat Speed Adj 01 1742 5&6 Cool Speed Adj 10 2204 7&8 Cool On/Off Delay 11 2204 Table 4 Cooling Delay Options (SW2-7, 8) ON DELAY OFF DELAY DIP SW2-7/8 Timed ON (sec) during on Timer OFF (sec) during off *00 5 OFF 90 100% 01 5 OFF 0 OFF 10 30 50% 30 100% 11 30 50% 180 50% % is of High Cool airflow demand determined from SW2--5/6 Table 1 resumes to 100% after on time is completed stops (or switches to continuous fan speed) after off time is completed MAX s for Factory Washable Filters Dimensions () 14 x 25 1400 16 x 25 1600 20 x 25 0 24 x 25 2500 MAX based on 600 FPM Note 1: Disposable filters are typically rated at 300 FPM. These filters only allow half the airflow when compared to 600 FPM filters. (example, 20 x 25 @ 600 FPM = 0, @ 300 FPM = 1000 )

Circulation Air Blower Data - *9MPV100 Cooling Settings High Cooling s *9MPV100J20 2700 2 1700 1 700 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Low Cooling s *9MPV100J20 0 1800 1600 1400 1 1000 800 600 Selection is from Highest to 400 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 9

DIP Switch 5&6 Circulation Air Blower Data - *9MPV125 Cooling Adjustment High Cool @ 0.50 in wc Low Cool (80% of High Cool) ** Adjust Jumper Setting 10 DIP Switch 3&4 Heating Rise Adjustment High Heat @0.20inwc Low Heat at Resultant Static 00 2150 1720 + 00 -- 4 -- 4 *00 2025 1620 *NOM *00 0 0 00 1856 1485 -- 00 4 5 01 1755 1404 + 01 1 2 01 1615 1292 NOM 01 6 7 01 1452 1162 -- 01 12 13 10 1338 1070 + 10 -- 1 0 10 1201 961 NOM 10 3 4 10 1069 855 -- 10 9 10 11 909 727 + 11 -- 6 -- 6 11 800 640 NOM 11 -- 3 -- 3 11 627 502 -- 11 3 3 performance includes 1 washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 10% reduction in airflow when in Comfort position and a call for low or high cooling is present with the O line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 20% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings. Table 2 Continuous Fan @ Table 3 SW2 DIP Assignments 0.10 in wc ESP DIP Switch Blower Parameter DIP Switch 1 & 2 () 1&2 Cont Fan Adj *00 1032 3&4 Heat Speed Adj 01 1778 5&6 Cool Speed Adj 10 2178 7&8 Cool On/Off Delay 11 2178 Table 4 Cooling Delay Options (SW2-7, 8) ON DELAY OFF DELAY DIP SW2-7/8 Timed ON (sec) during on Timer OFF (sec) during off *00 5 OFF 90 100% 01 5 OFF 0 OFF 10 30 50% 30 100% 11 30 50% 180 50% % is of High Cool airflow demand determined from SW2--5/6 Table 1 resumes to 100% after on time is completed stops (or switches to continuous fan speed) after off time is completed MAX s for Factory Washable Filters Dimensions () 14 x 25 1400 16 x 25 1600 20 x 25 0 24 x 25 2500 MAX based on 600 FPM Note 1: Disposable filters are typically rated at 300 FPM. These filters only allow half the airflow when compared to 600 FPM filters. (example, 20 x 25 @ 600 FPM = 0, @ 300 FPM = 1000 )

Circulation Air Blower Data - *9MPV125 Cooling Settings High Cooling s *9MPV125L20 2700 2 1700 1 700 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Low Cooling s *9MPV125L20 0 1800 1600 1400 1 1000 800 600 400 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 11

Variable Speed (MPV) Tap Select Interface Board (TSIB) TO FURNACE BOARD P3 BLU WHT GRN BLK BRN YEL P7 + NOM -- BLOWER ADJUST J1 TO FURNACE CONTROL 24VAC RED +NOM - BLOWER ADJUST SW2 1 2 3 4 5 6 7 8 J1 J2 AC/HP EFFICIENCY HP COMFORT SELECTION HP MODE SELECT INCREASE/NO CHANGE/DECREASE FROM 24V TRANS RED ON OFF CONT HEAT COOL COOL FAN DLY O Y1 J2 AC/HP EFFICIENCY HP COMFORT HP MODE SELECT SW2 1 2 3 4 5 6 7 8 HEAT PUMP EFFICIENCY OR HP COMFORT SELECTION CONT FAN HEAT COOL COOL DLY CONTINUOUS SELECT HEATING RISE SELECT COOLING SELECT COOLING ON/OFF DELAY PROFILES 25--25--54 International Comfort Products, LLC Lewisburg, TN 37091 U.S.A. www.gotempstar.com 12