Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

Similar documents
THE WALL-MOUNT TM SIX TON AIR CONDITIONER

WALL-MOUNT HEAT PUMPS - (60HZ)

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

GREEN REFRIGERANT R-410A

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

Q-TEC QC-Series Chilled Water Air Conditioner

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

Q-TEC Q24A-Q60A Air Conditioners

Q-Tec TM QC-Series Chilled Water Air Conditioner

THE WALL-MOUNT 6-TON AIR CONDITIONERS

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

Q/Tec TM QA-Series Air Conditioners

GREEN REFRIGERANT R-410A

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

Q/Tec TM QW-Series Water-to-Air Heat Pumps

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

Product Guide. Wallmount. Air Conditioners & Heat Pumps

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

Wall Mounted Air Conditioners with Gas Heat Models AVGA

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

RGE 13 A T - 1 A

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

62DA,DB,DC,DD,DE,DF07-38

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

48PGD/E/F/L/M/N PG20-28

MERIT Series R-410A - Upflow / Horizontal

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data. Fig. 1 - Unit 50VR -A

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner

REPLACEMENT PARTS MANUAL

13 GEP A L P - 1 A

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

MERIT Series R-410A - Upflow / Horizontal

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

50TM COMBINATION HEATING/COOLING UNITS

Commercial High-Efficiency Condensing Units

General Description. Operation

TECHNICAL SPECIFICATIONS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Submittal Summary Page

MACH N-407 Heat Pump Air-Cooled Chiller

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

50TM TFF COMBINATION HEATING/COOLING UNITS

PAJ3. Product Specifications

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

Commercial High-Efficiency Condensing Units

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

PAR5. Product Specifications

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602

Transcription:

THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 5.3 BTU/WATT WA3S WA5S Right Side Control Panel WL3S WL5S Left Side Control Panel 3 to 5 Ton (35,2 to 5,5 Btuh) Hz Green Refrigerant R-4A The Bard WA/L S Series features a multi-step capacity compressor with environmentally friendly non-ozone depleting refrigerant. The Bard Wall-Mount Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Engineered Features Multi-Capacity Two-Stage: Simple thermostatic control seamlessly stages the compressor and indoor airflow rate between high and low capacity operations without cycling the compressor. This helps to maximize comfort, humidity control, energy efficiency and overall reduction in compressor cycling for improved system life. Multi-Step Capacity Compressor: Copeland step-capacity scroll compressors are designed for increased efficiency, quieter operation and improved reliability for longer life. R-4A Refrigerant: Designed with R-4A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2 EPA requirements. ECM Indoor Blower Motor: Features a variable speed motor providing super-high efficiency, low sound levels and soft-start capabilities. The motor is selfadjusting to provide the proper airflow rate for the staged capacity, and for higher static pressure in ducted installations without user adjustment or wiring changes. Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. All models feature variable speed blower motors providing automatic airflow adjustment for high static or free blow (non-ducted) operation at a very low sound level. Motor overload protection is standard on all models. Foil Faced Insulation: on all units. Start Kit: A PTCR compressor start assist (Positive Temperature Coefficient Resistor) is standard on all -A single-phase models to increase system reliability. This helps to insure compressor starts at adverse conditions by increasing the compressor starting torque. Compressor Control Module: Built-in off-delay timer adjustable from 3 seconds to 5 minutes. 2-minute on-delay if power interrupt. 2-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. Liquid Line Filter Drier: on all units. Protects system against moisture. High & Low Pressure Switches are Auto-Reset: on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Crankcase Heaters: Factory installed crankcase heaters are standard on all models. This helps to insure ease of start at low temperatures and improves compressor life. Phase Rotation Monitor: on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Galvanized 2 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand hours of salt spray tests per ASTM B7-3. Galvanized Gauge Zinc Coated Unit Base: The unit base is treated with the same paint coatings as the cabinet above, insuring years of service without visible corrosion. Drain Pan: The evaporator drain pan is constructed of stainless steel material for maximum corrosion resistance. Complies with efficiency requirements of ASHRAE/IESNA.-23. Certified to ANSI/ARI 3-23 for SPVU (Single Package Vertical Units). Intertek ETL Listed to for Safety Heating and Cooling Equipment ANSI/UL 5/CSA 22.2 No. 23-5, Fourth Edition. Commercial Product - Not intended for Residential application. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat Strips: Features line break automatic limit and dual backup safety controls. Heater packages can be factory or field installed for all models. Filter Service Door: Separate service door provides easy access for filter change. Two-Inch, Pleated Disposable Air Filters: Are standard equipment. Condenser Fan and Motor Shroud Assembly: Slides out for easy access. Circuit Breakers/Rotary Disconnect: on all versions of single (23/2 volt) and three phase (23/2 volt) equipment. Rotary disconnects are standard on all versions of three phase (4 volt) equipment. Slope Top: feature for water run-off. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Top Rain Flashing: feature on all models. Bard is an ISO :2 Certified Manufacturer Form No. S337-27 Supersedes S337-77 Page of 2

Capacity and Efficiency Ratings Models Cooling Capacity BTUH, 2nd Stage Operation EER 2nd Stage Operation jk Rated CFM (Wet Coil) Cooling Capacity BTUH, st Stage Operation EER st Stage Operation k Rated CFM (Wet Coil) 35,2.4 24,4.7,5.2 5 34,.7 5,5.4 7 4,. 3 IPLV l 5. 5.3 4. Certified in accordance with ANSI/ARI 3-23 for single package vertical units. EER = Energy Efficiency Ratio - BTU/WATT efficiency. Integrated Part Load Value - BTU/WATT efficiency and certified in accordance with ANSI/ARI 3-23. All capacity, efficiency and cost of operation information is based on operation with fresh air cover plate. Cover plate is recommended for use to obtain maximum energy efficiency where ventilation air is not required. Indoor Blower Performance - CFM (. through. H 2 O) Blower Only st Stage Cooling 2nd Stage Cooling 5- KW Electric Heat 5-2 KW Electric Heat 4 25 5 5 5 3 7 5 These systems contain Variable Speed ECM Motor, which maintains airflow across static range at dry and wet coil conditions. Specifications 3 Ton through 5 Ton MODELS -A -A -B -B -C -C -A -A -B -B -C -C -A -A -B -B -C -C Cooling Capacity 35,2 35,2 35,2,5,5,5 5,5 5,5 5,5 Heating Capacity Electrical Rating Hz 23/2-23/2-3 4-3 23/2-23/2-3 4-3 23/2-23/2-3 4-3 Operating Voltage Range 7-253 7-253 44-5 7-253 7-253 44-5 7-253 7-253 44-5 Compressor Circuit A Voltage 23/2 23/2 4 23/2 23/2 4 23/2 23/2 4 Rated Load Amps 2.3/4..7/7. 3../../2 4. 2./2. 5.5/. 7. Branch Circuit Selection Current.7.2 4.5 2.2 3.5.5 2... Lock Rotor Amps 2 / 2 5 / 5 3 / / 4 / 23 / 23 2 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Fan Motor & Condenser Fan Motor--HP--RPM-SPD /3-25 - 2 /3-25 - 2 /3-25 - /3-25 - 2 /3-25 - 2 /3-25 - /3-25 - 2 /3-25 - 2 Fan Motor--Amps 2.5 2.5.3 2.5 2.5.3 2.5 2.5.3 /3-25 - Fan--DIA/CFM 24" - 27 24" - 27 24" - 27 24" - 2 24" - 2 24" - 2 24" - 2 24" - 2 24" - 2 Blower Motor & Evap. Blower Motor--HP-RPM-SPD See Electric Heat Table /2-Variable /2-Variable /2-Variable 3/4-Variable 3/4-Variable 3/4-Variable 3/4-Variable 3/4-Variable 3/4-Variable Blower Motor--Amps 5.3 5.3 5.3...... CFM Cooling & E.S.P. 5 5 5 7 7 7 Filter Size 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 Basic Unit Weight --LBS. 55 55 55 55 55 55 57 57 57 Blank-Off Plate Motorized Fresh Air Damper.5.5.5.5.5.5.5.5.5 Commercial Room Ventilator 42 42 42 42 42 42 42 42 42 Economizer 5 5 5 5 5 5 5 5 5 Energy Recovery Ventilator Form No. S337-27 Supersedes S337-77 Page 2 of 2

Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a blank off plate as the standard ventilation package. All ventilation packages can be built-in at the factory, or field-installed at a later date. BLANK OFF PLATE - BOP STANDARD A blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. MOTORIZED FRESH AIR DAMPER - MFAD OPTIONAL The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a 24VAC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy. Motorized Fresh Air Damper MIS-35 NOTE: This vent system is intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Other building systems will govern actual amount of intake air. Commercial Room Ventilator Economizer Energy Recovery Ventilator MIS-3 MIS-3 MIS-37 COMMERCIAL ROOM VENTILATOR - CRVMP OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper with integral bug screen. Automatic control is integrated to maintain desired ventilation air at the various supply airflows. The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. The CRV is power open - spring return on power loss. Complies with ANSI/ ASHRAE 2. Ventilation for Acceptable Indoor Air Quality. ECONOMIZER - ECONWM-Series OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. ECONWMT Equipment Building versions have extended air intake hood to deliver up to % of cooling rated airflow. ECONWMS versions have 3 air intake hood to deliver up to % of cooling rated airflow. Features: Fully modulating Honeywell Direct Drive Hi-Torque Actuator No linkage required Simple single blade design Positive shut-off with non-stick gaskets Electronic DB and/or Enthalpy sensors depending upon version Honeywell JADE electronic economizer module with precision settings and diagnostics DB or Enthalpy economizer versions available WALL-MOUNT ENERGY RECOVERY VENTILATOR - ERVF OPTIONAL The wall-mount energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE 2.. The ERV allows from 2 to CFM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 7% during summer and % during winter conditions. The ERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV is designed to be internally mounted behind the service door in the WA/LS model wall-mount units. It can be built-in at the factory or field installed as an option. ERVF-*5 can be independently adjusted for intake and exhaust rates. Form No. S337-27 Supersedes S337-77 Page 3 of 2

CRVMP-5 WA3S/WL3S Ventilation Airflow 7 Ventilation Airflow (CFM) 5 4 3 Stage #2 Operation Blower Only & Stage # Operation 2 2.5 5 7.5 2.5 5 7.5 2 22.5 25 27.5 3 Vent Position CRVMP-5 WA4S/WL4S Ventilation Airflow 7 Ventilation Airflow (CFM) 5 4 Stage #2 Operation Stage # Operation Blower Only 3 2 2.5 5 7.5 2.5 5 7.5 2 22.5 25 27.5 3 Vent Position CRVMP-5 WA5S/WL5S Ventilation Airflow 7 Ventilation Airflow (CFM) 5 4 3 Stage #2 Operation Stage # Operation Blower Only 2 Form No. S337-27 Supersedes S337-77 Page 4 of 2 2.5 5 7.5 2.5 5 7.5 2 22.5 25 27.5 3 Vent Position

Performance and Application Data- WERV-*5 SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/2 WB) DB/ WB Ambient O.D. VENTILATION RATE -- CFM VENTILATION RATE -- 3 CFM VENTILATION RATE -- 3 CFM F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 5 7 5 2 4 352 477 477 477 477 477 44 77 25 25 25 25 25 5737 5 37 43 72 72 72 72 72 57 52 52 52 52 52 3 7 5 35 2 2352 25 25 25 25 25 25 25 44 34 22 2533 352 2 77 77 77 77 77 77 77 235 54 3 2325 77 23 25 25 25 25 25 25 25 2 772 7374 5 73 2 2 2 2 2 2 2 2 523 2 43 235 2 2 35 4 57 557 3 4 5 7 5 35 2 2352 72 72 72 72 72 72 72 27 744 232 2533 352 2 3 3 3 3 3 3 3 425 734 7 2325 77 23 225 77 23 7374 5 73 53 53 53 53 53 53 53 22 447 2 43 235 4 4 4 4 4 4 4 73 5 4 57 557 434 434 434 434 434 434 434 7 524 7 5 35 2 2352 72 72 72 72 72 72 72 243 4 52 2533 352 2 473 473 473 473 473 473 473 574 23 32 2325 77 23 225 2 42 7374 5 73 4 4 4 4 4 4 4 335 77 274 2 43 235 4 4 4 4 4 4 4 2 33 4 57 557 325 325 325 325 325 325 325 54 33 22 5 7 5 35 2 2352 4 4 4 4 4 4 4 273 5 742 2533 352 2 35 35 35 35 35 35 35 7374 73 47 2325 77 23 222 337 243 7374 5 73 272 272 272 272 272 272 272 47 32 42 2 43 235 324 324 324 324 324 324 324 72 7 4 57 557 27 27 27 27 27 27 27 3 74 334 7 5 2 2352 4252 243 243 243 243 243 35 22 22 352 2 274 57 57 57 57 57 2372 44 4 77 23 3543 225 225 225 225 225 52 2 5 5 73 233 33 33 33 33 33 4 57 2 43 235 235 2 2 2 2 2 2 5 25 57 557 5 5 5 5 5 52 4432 4 7 5 2352 4252 2352 4252 2 274 2 274 23 3543 23 3543 73 233 73 233 235 235 235 235 557 557 Ambient O.D. WERV-*5 WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 7 F DB) VENTILATION RATE CFM 3 CFM 3 CFM DB/ F WVL WHR WVL WHR WVL WHR 5 243 44 225 4 2 32 4 3 32 324 25 55 72 532 42 4 35 5 72 777 5 4 533 25 72 25 2 42 4 4 25 4 72 77 35 7 3 4 4 34 2 3 44 5552 2 322 2 27 25 27 74 225 472 55 2 243 44 225 42 2 324 5 273 234 222 42 72 42 NOTE: Sensible performance only is shown for winter application. LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery Form No. S337-27 Supersedes S337-77 Page 5 of 2

Electrical Specifications MODEL -AZ -A5 -A -A -A5 -A2 Rated Volts & Phase 23/2- No. Field Power Circuits or 2 or 2 or 3 Minimum Circuit Ampacity 3 35 5 7 3 Maximum External Fuse or Ckt. Brkr. 7 5 Single Circuit Multiple Circuit Field Power Wire Size 3 2 Ground Wire Minimum Circuit Ampacity Maximum External Fuse or Ckt. Breaker Field Power Wire Size Ground Wire Size Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C 35 35 35 2 52 52 2 3 3 -BZ -B -B -B5 23/2-25 27 3 55 3 3 4 -CZ -C -C -C5 4-3 3 4 2 5 5 2 3 4 4 2 4 4 2 -AZ -A5 -A -A -A5 -A2 23/2- or 2 or 2 or 3 3 3 53 3 5 7 2 3 2 37 37 37 2 52 52 2 3 3 -BZ -B -B -B5 23/2-3 2 2 3 5 4 4 4 -CZ -C -C -C5 4-3 5 2 3 2 2 25 3 2 2 2 2 -AZ -A5 -A -A -A5 -A2 23/2- or 2 or 2 or 3 44 44 53 3 5 5 5 7 2 3 2 44 44 44 2 52 52 2 5 5 5 3 3 -BZ -B -B -B5 23/2-3 34 34 3 5 4 4 4 -CZ -C -C -C5 4-3 7 7 2 3 25 25 25 3 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. * Top outlet supply option is available only factory installed and only on the selected models. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all local codes. Form No. S337-27 Supersedes S337-77 Page of 2

Electric Heat Table Nominal KW Kw At 24V () At 2V () At 4V (2) At 4V (2) -Ph Amps 3-Ph Amps Btuh Kw -Ph Amps 3-Ph Amps Btuh Kw 3-Ph Amps Btuh Kw 3-Ph Amps Btuh 5. 5. 2. 7,5 3.. 2,7.. 4.4 2,47 4.5 2.5 5,35. 7.2 2,47 5.52.,4.. 33.3 27,34. 2. 2,47.. 2.7 3,77..7 23,3.. 3,77.2.4 2,2.. 4.7 34,3 7.5 3. 25,5 5. 5. 2.5 3. 5,5.25 54. 3.2 3,3 5.. 5,5 3. 7.3 47, 2. 2. 3.3,2 5. 72. 5,5 () These electric heaters are available in 23/2V units only. (2) These electric heaters are available in 4V units only. Heater Packages - Field Installed WA3, WA4 & WA5S Designed for adding Electric Heat to KW Units Circuit Breaker on 23/2V Models Air Conditioner Models -A Models 23/2- ETL US & Canada Listed Toggle Disconnect on 4V Models -B Models 23/2-3 -C Models 4-3 Heater Model # KW Heater Model # KW Heater Model # KW EHWA4S-A5B EHWA5S-AB EHWA4S-AB EHWA4S-A5B EHWA4S-A2B 5 5 2 EHWA3S-BB EHWA5S-BB EHWA5S-B5B 5 EHWA5S-C EHWA5S-C EHWA5S-C5 5 EHWA4S-A5B EHWA5S-AB EHWA4S-AB EHWA4S-A5B EHWA4S-A2B 5 5 2 EHWA5S-BB EHWA5S-BB EHWA5S-B5B 5 EHWA5S-C EHWA5S-C EHWA5S-C5 5 EHWA5S-A5B EHWA5S-AB EHWA5S-AB EHWA5S-A5B EHWA5S-A2B 5 5 2 EHWA5S-BB EHWA5S-BB EHWA5S-B5B 5 EHWA5S-C EHWA5S-C EHWA5S-C5 5 Heater Packages - Field Installed WL3, WL4 & WL5S Designed for adding Electric Heat to KW Units Circuit Breaker on 23/2V Models Air Conditioner Models -A Models 23/2- ETL US & Canada Listed Toggle Disconnect on 4V Models -B Models 23/2-3 -C Models 4-3 Heater Model # KW Heater Model # KW Heater Model # KW EHWA4S-A5LB EHWA5S-ALB EHWA4S-ALB EHWA4S-A5LB EHWA4S-A2LB 5 5 2 EHWA3S-BLB EHWA5S-BLB EHWA5S-B5LB 5 EHWA5S-CL EHWA5S-CL EHWA5S-C5L 5 EHWA4S-A5LB EHWA5S-ALB EHWA4S-ALB EHWA4S-A5LB EHWA4S-A2LB 5 5 2 EHWA5S-BLB EHWA5S-BLB EHWA5S-B5LB 5 EHWA5S-CL EHWA5S-CL EHWA5S-C5L 5 EHWA5S-A5LB EHWA5S-ALB EHWA5S-ALB EHWA5S-A5LB EHWA5S-A2LB 5 5 2 EHWA5S-BLB EHWA5S-BLB EHWA5S-B5LB 5 EHWA5S-CL EHWA5S-CL EHWA5S-C5L 5 Form No. S337-27 Supersedes S337-77 Page 7 of 2

Acoustical Plenum WAPR Free Blow Acoustical Plenum WAPFB5 2 /4" 42 3/" 3 3/4" /2" 42 /4" 3 3/4" /2" 3/" 7/" 3 3/4" 34 /4" /2" 2 7/" /2" MIS-224 A 2 /" 7" MIS-22 A Optional Installation Accessories Description Model Color Acoustical Plenum Ducted Supply Air Acoustical Plenum Free Blow Supply Air Acoustical Plenum WAPR-X WAPR-4 Beige Buckeye Gray Shipping Weight (Lbs.) 25 WAPS5-G Galvanized 4 WAPFB5-X WAPFB5-4 Beige Buckeye Gray 7 Supply Air Acoustical Plenum WAPS5-G 44" 2" 5" 7/" 4" 5 3/4" 2 7/" 4" " MIS-24 2" DIA. HOLES FOR DUCT COLLARS. DUCT COLLARS FIELD SUPPLIED. Typical installation with isolation curb, free blow, supply air acoustical plenum & return air acoustical plenum. WMICF5 ISOLATION CURB WAPF5 FREE-BLOW SUPPLY AIR PLENUM WMICF5 ISOLATION CURB WAPF5 FREE-BLOW SUPPLY AIR PLENUM WAPR RETURN AIR ACCOUSTICAL PLENUM WAPR RETURN AIR ACCOUSTICAL PLENUM Patent Pending Form No. S337-27 Supersedes S337-77 Page of 2 MIS-24

Typical Sound Performance with Installation/Isolation s & Acoustical Plenums WA/L3S Sound Data Matrix (dba @ feet) Unit Mounting Supply Air Treatment Treatment Blower Only Operation with CRV Compressor Stage Operation with CRV Compressor Stage 2 Operation Compressor Stage 2 with ERV High Speed Operation Free Blow Configuration Direct Isolation WAPFB5 Free Blow Supply Air Plenum WAPR-X Direct Ducted Supply Configuration Direct Isolation Isolation WAPS5-G Supply Air WAPR-X WAPR-X 37. 3.7 33. 33. 27.4 27. 5. 4.7 4. 4.7 3.7 3.7 52.3 4.4 5. 42.4 4. 3. 52.7 4.7 5.7 42. Indoor Integrated dba 43. 35. 4.7 37.2 32. 32. Compressor Stage 2...... Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. WA/L4S Sound Data Matrix (dba @ feet) Unit Mounting Supply Air Treatment Treatment Free Blow Configuration Direct Isolation WAPFB5 Free Blow Supply Air Plenum WAPR-X Direct Ducted Supply Configuration Direct Isolation Isolation WAPS5-G Supply Air WAPR-X Blower Only Operation 4. 3. 3.4 34.5 32. 2.2 Compressor Stage Operation Compressor Stage 2 Operation Compressor Stage 2 with ERV High Speed Operation WAPR-X 52. 4.4 5. 4.2 4.5 3. 53.7 44. 52. 44.3 42. 4.5 55. 4.2 54. 44. Indoor Integrated dba.4 4.4 44. 37. 35. 33. Compressor Stage 2 5. 5. 5. 5. 5. 5. Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. WA/L5S Sound Data Matrix (dba @ feet) Unit Mounting Supply Air Treatment Treatment Free Blow Configuration Direct Isolation WAPFB5 Free Blow Supply Air Plenum WAPR-X Direct Ducted Supply Configuration Direct Isolation Isolation WAPS5-G Supply Air WAPR-X Blower Only Operation 4.3 33.3 35. 34. 33.5 3. Compressor Stage Operation Compressor Stage 2 Operation Compressor Stage 2 with ERV High Speed Operation WAPR-X 52. 4. 5. 43. 4. 3. 5.7.3 5. 4. 44.5 43.2 57. 47. 55..4 Indoor Integrated dba 4.2 37.2 4. 3. 37.2 35.4 Compressor Stage 2 5.4 5.4 5.4 5.4 5.4 5.4 Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. Form No. S337-27 Supersedes S337-77 Page of 2

2nd Stage Cooling Application Data - Outdoor Temperature Model D.B./W.B. k Cooling Capacity BTU/HR 5 F 55 F F 5 F 7 F F F 5 F F 5 F F 5 F F 5 F /2 44,25 42,5 4, 4,325 3,5 37, 3,55 35,3 34,5 32, 3,4 3,5 2,25 27,5 32,3 3,5 3,3 3,7 3,225 2,7 2,2 2,7 2,2 27,7 27,25 2,35 25, 25, /7 4,5 47, 4, 44, 43,2 4,7 4,25 3,55 3, 35,2 34,225 33, 3, 3, 32,3 3, 3,225 3,5 3, 2,5 2,4 2,3 27, 27, 2,25 2, 25, 25,3 5/72 53,5 5,7 5,25 4, 47,35, 44,4 43,5 4,25 4,2 3,5 37, 35,55 34, 32, 3,55 3,5 3,525 3,25 2,5 2, 2,5 2, 27,5 2,25 2,35 25,7 25,2 /2 5,25 53, 5,5 5,5 4,525 4,4 4,5,5 44,5 42, 4,7 3,5 37,25 35,3 4, 4, 3, 3,7 3,25 37,3 3,725 3,5 35,5 35, 34, 33, 32, 3, /7 2,725 5, 5, 55,5 53,325 53, 5,7 4, 47,,5 44,4 42,5 4,425 3, 4, 4,3 4,4 3,5 3, 37, 3,7 35, 34, 34, 33, 32, 32,35 3, 5/72,425,7 4, 2,, 5, 57, 5,5 54,25 52,2 5,3 4,55 4,725 44, 4,25 4,5 4,725 3,25 3,5 37, 37, 3,3 35,5 34,7 33, 33,25 32,525 3, /2,35 7,525 5,7 3, 2,,25 5,425 5,25 54,25 53, 5,5 4,3 47,, 4,5 4, 4, 47,325 4,5,, 44,325 43, 42,5 4, 4, 4,2 3,3 /7 74, 72,7 7,,,25 4,5 2,7, 5, 5,5 54,5 53,4 5,5 5,3 4,325 47,55 4,,, 44,4 43,5 42, 4,7 4, 4,4 4,5 3,25 3,5 5/72 7,3 77,5,5 74,225 72,525 7,,2 7,,225 4,7 2,25 5,7 57,325 54,5 4,425,,35 44,25 44,2 43, 43,2 42, 42,325 4,5 4, 4,325 3,5 3, st Stage Cooling Application Data - Outdoor Temperature Model D.B./W.B. k /2 /7 5/72 /2 /7 5/72 /2 /7 5/72 Cooling Capacity BTU/HR Below 5 F, unit requires a factory or field-installed low ambient control. Return air temperature F. 5 F 55 F F 5 F 7 F F F 5 F F 5 F F 5 F F 5 F 3,25 2,2 2,3 27,35 2,3 25,4 24, 23,5 22,55 2, 2,55,5, 7,4 22,7 22,3 2,25 2,35 2, 2,4,5,5,5,,25 7,,,3 34,3 33,5 32,25 3, 2, 2, 27, 2,3 25,5 24,4 22, 2, 2,7, 23, 22,5 22,5 2,525 2,25 2,5,,425,,35 7,25 7,4 7,5, 37, 3,7 35,525 34,35 33, 32, 3,25 2,5 2,4 27,3 2,25 24,25 23, 22,55 22,4 22, 2, 2,2 2, 2,4 2,25,5,2,,425 7,25 7,,5 4, 3, 3, 37,525 3,3 35,3 34,2 33, 32, 3, 2, 2,3 27, 25,7 2, 3, 2,4 2,25 2,4 27, 2,4 25,5 25,425 24, 24,325 23, 23, 22,,3 43,5 42,225 4,5 3, 3, 37, 3,5 35,25 34, 32,25 3,25 2, 2,5 2, 3, 2,55 2, 2, 27, 2,55 2, 25, 24, 24,35 23,7 23,225 22,5 5,2 4, 4,5, 43,725 43, 42,4 4, 3,4 37, 3, 35,3 34, 32,7 3,25 2, 2, 2,3 27, 27,4 2,725 2,25 25,35 24,5 24, 23,7 23,225 22, 5,3 4,5 47,725 4,4, 43, 42,55 4,35 4,5 3,5 37,5 35,325 33,525 3,7 37,25 3,5 3,5 35,525 35, 34, 33, 33,5 33,25 32,55 3,7 3,25 3,2 2,5 5,25 5, 54, 52, 5, 4,5 4,5 44,425 42,225 4, 3,7 37,55 3,325 35, 3, 3,4 35, 35,3 34,5 34,35 33, 32,525 3,25 3,7 3,25 32,25 34,5 35,5 2,55, 5,5 57,3 55,55 53, 52,5 5,2 4,525 4,,5 43,35 4,5 3,5 3,25 35,7 35,3 34,25 34,3 33, 33,4 33,25 32, 32,5 3, 3, 3,4 2, Clearances Required for Service Access and Adequate Condenser Airflow Intake MODELS LEFT SIDE RIGHT SIDE WA/L3S, WA/L4S, WA/L5S 2" 2" Minimum Clearances Required to Combustible Materials MODELS SUPPLY AIR DUCT FIRST THREE FEET CABINET WA/L3S, WA/L4S, WA/L5S /4" " Refer to the Installation Manual for more detailed information. Unit Charge Rates (R-4A) UNIT / - High Efficiency RH/LH Step Capacity A/C / - High Efficiency RH/LH Step Capacity A/C / - High Efficiency RH/LH Step Capacity A/C Std. Unit - Lbs.. 5.25 5.3 Form No. S337-27 Supersedes S337-77 Page of 2

Dimensions of Basic Unit for Architectural & Installation Requirements (Nominal) MODEL WIDTH (W) DEPTH (D) HEIGHT (H) SUPPLY RETURN All dimensions are in inches. Dimensional drawings are not to scale. A B C B E F G I J K L M N O P Q R S S2 T 42. 22.432 4.. 2. 5. 2. 43. 3.5 3. 3. 32. 2.4 34. 32.43 3.37 43. 23...44... 42. 22.432 4.. 2. 5. 2. 43. 3.5 4. 3. 42. 3.4 44. 42.43 3.37 43. 33...44. 2.. WA3-4-5S Models W Built In Rain Hood 4 Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Hood for ERV and ECONWMS models only D 2.3 A I Side Wall Mounting Brackets (Built In) Top Rain Flashing Shipping Location E O Supply Air Opening B.44 R S S 5. F G Filter Access Panel Ventilation Air Condenser Air Outlet flush vent 3" door for non-erv/ Econ. models " Low Voltage Hood for Electrical ECONWMT Entrance models. High Voltage Electrical Entrance Cond. Air Inlet J C K H Optional Electrical Entrances L M P Opening S S2 S2 T Front View Side View Drain N Q Back View Bottom Installation Bracket MIS-3234 R S S Built In Electric E Rain Hood Heat Heater O 4 Pitch Access.44 Panel D C. Breaker/ W 2.3 Disconnect Access Panel Side Wall Supply Air Opening (Lockable) Mounting A Brackets flush (Built In) vent door for B non-erv/econ. models Top Rain Flashing Shipping Location I.25 Hood used on ERV and ECONWMS only WL3-4-5S Models S Opening Optional Electrical Entrances C 3" Filter Access Panel Ventilation Air 5. F S2 S2 T Drain Bottom Installation Bracket Back View Q P M N L H K J Cond. Air Inlet Side View " Hood for ECONWMT models. Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser Air Outlet Front View Not used when ECONWMT Economizers installed. Filter access is through the ECONWMT hood. G MIS-324 B Form No. S337-27 Supersedes S337-77 Page of 2

Air Conditioning Wall-Mount Model Nomenclature MODEL NUMBER WA Right Hand WL Left Hand CAPACITY 3S - 3 Ton 4S - 4 Ton 5S - 5 Ton WA 3S 3 A B P X X X X Ventilation Options REVISION WA 3 WL 2 VOLTS & PHASE A - 23/2// B - 23/2//3 C - 4//3 Models Description KW VENTILATION OPTIONS (See Chart Below) FILTER OPTIONS P - 2 inch Pleated MERV COLOR OPTIONS X - Beige () - White 4 - Buckeye Gray 5 - Desert Brown - Dark Bronze A - Aluminum S - Stainless Steel NOTE: For KW and circuit breakers (23/2 Volt) or rotary disconnect (4 Volt) applications, insert Z in the KW field of the model number. Factory Installed Code No. All Models Field Installed Part No. Blank-Off Plate B BOP-5 Motorized Fresh Air Damper M MFAD-5 Commercial Ventilator - Motorized w/exhaust V CRVMP-5 Economizer - Versions, Enthalpy m S ECONWMS-E5B* k Economizer - Equipment Building, Enthalpy n W ECONWMT-E5B* k Economizer - Equipment Building, DB Temp n T ECONWMT-T5B* k Energy Recovery Ventilator - 23 Volt l R ERVF-A5 j Energy Recovery Ventilator - 4 Volt l R ERVF-C5 j Door Kit for ERVF (Required) N/A WMDK5- l Intake and exhaust can be independently adjusted. Insert color to match unit ("X" = Beige; "4" = Buckeye Gray; etc.) WMDK Door Kit must be ordered in addition to ERVF Assembly and color matched to unit ("X" = Beige; "4" = Buckeye Gray; etc.) Partial Full Flow (% of Rated Cooling CFM). All ECONWMS versions have 3" deep intake hood. Full Flow (% of Rated Cooling CFM). ALL ECONWMT versions have " deep intake hood. CONTROL MODULES (See Chart Below) COIL OPTIONS X - - Phenolic Coated Evaporator 2 - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator & Condenser SUPPLY AIR OUTLET X - Front () Air Conditioning Control Modules AVAILABLE CONTROL OPTIONS ALL MODELS HPC LPC CCM LAC ALR SK DDC p Factory Installed Code Field Installed Part STD STD STD STD X N/A STD STD STD STD H CMA-2 STD STD STD STD J Factory Only STD STD STD STD V p Factory Only STD = equipment for these specified models. HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note. LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note. CCM. Compressor control module has adjustable 3-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2-minutes plus % of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with retry) for high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control. LAC. Low ambient control permits cooling operation down to F. ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. SK. Start kit standard on all -A single phase models only. Is not used or available for -B or -C three phase models. DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status. Form No. S337-27 Supersedes S337-77 Page 2 of 2 Bard Manufacturing Company, Inc. Bryan, Ohio 435 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S337 December 27 Supersedes S352-77