C-Bus Four Channel Analogue Output Unit Installation Instructions

Similar documents
C-Bus Four Channel General Input Unit Installation Instructions

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

C-Bus Reflection Range Installation Instructions

C-Bus Neo Range Installation Instructions. 5050NL Series

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Light Level Detector, Surface Mount 5754PE. Installation Instructions

C - B u s C - T o u c h U s e r s G u i d e C T Series

StarServe IR/RF Controller Installation Instructions. 2031RFT Series

Square D Clipsal Outdoor Light-Level Sensor

Instruction Manual SCD24. Read this document prior to installation. Contents

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

Push Button Electronic Timer. 31VETR Series. Installation Instructions

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Mains Power Filter 970MF10 970MF20. Installation Instructions

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Intercom Systems Video Intercoms

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Connections, displays and operating elements C D E G H. Installing the control unit

Dimmer / Fan Controller Installation Instructions

General Routing Interface

Door Release Power Supply

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Integrated PIR detectors

Networked Access Control Panel. Installation Guide

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Installation and Operation Manual Low Power (LP) DC Power System

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Universal fault annunciator for panel mounting

AO Annunciator Module

Installation, Operating and Maintenance Manual

EOTec 2C32 Installation Guide

MTDPC. (also known as MTPC) INSTALLATION AND OPERATION MANUAL MultiTrode Pump Controller

Single phase solid state contactors ENG. User Manual DATA MANAGEMENT CONTROLS PROCESS AUTOMATION

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Public Safety DAS Annunciator Panel

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

M2500 Engine Controller Installation Manual

Intelligent Security & Fire Ltd

PTE0705 Electric Fence Monitor

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Pure Glass. saturn.clipsal.com

P2267 NETWORK INTERFACE

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

East Central College

Flostop TS D7E and A8E. Operation Manual

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

REA 105 Arc Protection Module. Operator s Manual

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

USER MANUAL FOR OPERATING SYSTEM

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

VACIE REFERENCE GUIDE REVISION 1.2.6

Vocia VACIE. Reference Guide

The Remote alarm Panel, TYPE RAPv2

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Get connected with Xantrex Grid-Tie Inverters

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Automatic Lamp & Mat Heating Control

SHUTTLE BELL-PRESS DIMMER DATA SHEET

Insulation fault evaluator EDS460-DG

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

Fume Hood Operating Display Panel

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Flopurge TS. Operation Manual

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

SECTION AUTOMATIC TRANSFER SWITCHES

HLS-2C Active Hearing Loop Panel

Imperial War Museum. Case Study 17. clipsal.com UNITED KINGDOM. C-Bus Control and Management System

EBMHS (standard & slim-line PSU)

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

Intelligent Security & Fire Ltd

Fratech Multipath-IP

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

XP95 Sounder VAD Base

Instructions for the fan motor control system, SILVER C

Transcription:

C-Bus Four Channel Analogue Output Unit Installation Instructions 5504AMP Series REGISTERED PATENT

Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3 4.0 Wiring Instructions...4 5.0 Connection to the C-Bus Network...4 6.0 C-Bus DIN Rail Series Analogue Output Features...5 6.1 Local Override Buttons...5 6.2 Remote Override Facility...6 7.0 Priority of Operating Modes...6 8.0 Status Indicators...7 8.1 C-Bus Indicator...7 8.2 Unit Indicator...7 9.0 C-Bus System Clock...7 10.0 Power-Up Load Status...8 11.0 C-Bus Power Requirements...8 12.0 Stand-Alone Programming...8 13.0 Power Surges and Short Circuit Conditions...8 14.0 Megger Testing...8 15.0 Standards Complied...9 16.0 Programming Requirements...10 17.0 Important Warning...10 18.0 Mechanical Specifications...10 19.0 Electrical Specifications...11 Copyright Notice Copyright 2003 Clipsal Integrated Systems Pty Ltd. All rights reserved. Trademarks Clipsal is a registered trademark of Gerard Industries Pty Ltd. C-Bus and C-Bus2 are registered trademarks of Clipsal Integrated Systems Pty Ltd. Intelligent Building Series is a registered trademark of Clipsal Integrated Systems Pty Ltd. All other logos and trademarks are the property of their respective owners. Disclaimer Clipsal Integrated Systems reserves the right to change specifications or designs described in this manual without notice and without obligation. Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 2

1.0 Product Range L5504AMP Four Channel Analogue Output Unit (220-240V, 50-60 Hz) LE5504TAMP Four Channel Analogue Output Unit (110-120V, 50-60 Hz) 2.0 Description The 5504AMP Series Analogue Output unit provides analogue output voltages in the range 0-10V, which can be used as the control signals for various peripheral devices including electronically dimmable fluorescent lighting ballasts. For ease of installation they are DIN rail mounted, measuring 4M wide (1M = 17.5 +0.5/-0.0 mm). C-Bus connection is conveniently achieved through the use of RJ45 connectors, allowing similar units to be quickly looped together. 3.0 Capabilities The 5504AMP Series Analogue Output unit comprises of 0-10VDC output controlled by instructions from the C-Bus Network. The unit is capable of sinking or sourcing current as appropriate for the connected load (Refer to Section 19.0, Electrical Specifications for output ratings). Each channel may drive multiple loads, depending on the load current requirements. The unit isolates the mains power from the safe extra low voltage C-Bus Network. Output Channels of the Unit are not isolated from each other, and can be commoned to reduce cabling requirements. The connection is polarity sensitive (Refer to Section 4.0, Wiring Instructions). Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 3

4.0 Wiring Instructions Mains Supply 240VAC C-Bus Category 5 Cable 5005C305B Earth Line 2/N Line 1/A 1 2 3 4 C-Bus2 2 8 1 7 CAT 5 Surface Box 4 6 SMRJ88A5/1 5 3 Local Toggle Buttons C-Bus2 1 2 3 4 1A 1B 2A 2B 3A 3B 4A 4B 1A 1B 2A 2B 3A 3B 4A 4B C-Bus Network C-Bus Patch Cord RJ5CB300PL NOTE: A maximum of 50 x 5504AMP Series units may be interconnected. The installer must fix mains cables in the distribution board using cable ties or trunking as required by local wiring rules. Care must be taken not to allow copper strands to enter the DIN unit s apertures. Rubber bungs are supplied (3 off) for unused RJ45 connectors, to stop foreign bodies from entering the unit. Always ensure these bungs are installed when the Unit is to be mounted inside a mains rated enclosure. 5.0 Connection to the C-Bus Network Installation requires connection to the unshielded twisted pair C-Bus Network Cable. This illustration shows the recommended technique for cable termination giving the best electrical performance. It is required that Category 5 data cable is used, Clipsal catalogue number 5005C305B. RJ Pin C-Bus Connection Colour 1 Remote ON Green/White 2 Remote ON Green 3 C-Bus Neg (-) Orange/White 4 C-Bus Pos (+) Blue 5 C-Bus Neg (-) Blue/White 6 C-Bus Pos (+) Orange 7 Remote OFF Brown/White 8 Remote OFF Brown Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 4

NOTE: It is recommended that the Remote Override (On/) connections be maintained for correct operation of these services across the C-Bus Network, even if they are not intended to be used. Remote Override services may be disabled in software if necessary. 6.0 C-Bus DIN Rail Series Analogue Output Features 6.1 Local Override Buttons The buttons located on the front of the unit provide a means to toggle each channel locally (at the unit). Each button is illuminated when the respective channel is in the On state. Operation Short Press Double Click Function One short press will toggle the state of this channel only Two short presses within 2 seconds will return this channel only to the C-Bus Network level Long Press Pressing any of the Local Override buttons for longer than 2 seconds will return all channels to the C-Bus Network level Note double-click and long press operations will only occur if the unit/channel is already in override mode. C-Bus commands received by the unit will (by default) override local toggle changes. In this case, only the channel associated with the received commands will revert to the current C-Bus Network state. This option may be disabled in software. Please refer to Section 7.0, Priority of Operating Modes. Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 5

6.2 Remote Override Facility Remote control of all channels on a unit can be achieved via the extra pairs of conductors on the C-Bus connector. This diagram shows that switches may be connected in parallel on any one Network, using green and green/white conductors for the remote ON function. Brown and Brown/White may be wired in the same fashion for remote OFF, with these conductors being connected to C-Bus negative via the switch to action this state. A Clipsal 30/1/2LM mechanism makes an ideal remote input switch. NOTE: C-Bus is a balanced network and therefore at any point where C-Bus negative (-) is taken, C-Bus positive (+) must also be present. Hence both network conductors must be looped through all remote input switches on the Network. 7.0 Priority of Operating Modes The output status of the 5504AMP Series C-Bus Four Channel Analogue Output Unit can be changed by: Pressing a C-Bus Key, By activating any of the Local Override buttons or By using the Remote Override facilities. The table below shows the priority ranking of these control inputs, Mode Priority Function Remote OFF 1 (Highest) Turns all channels OFF Remote ON 2 Turns all channels ON Local Override 3* Toggle channel C-Bus Input Unit (Key, PIR etc) 4* (Lowest) Control the channel For further information about the programming this and other C-Bus units, please refer to the C-Bus Technical Manual (5000S/2, 5000M/2). Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 6

8.0 Status Indicators 8.1 C-Bus Indicator This indicator shows the status of the C-Bus Network at this unit. If sufficient network voltage and a valid C-Bus Clock signal are present then the OK signal will be displayed (continuous green light). If a Network is connected which has more current load than the power supplies can support, then this indicator will flash to show a marginal Network voltage. If there is no C-Bus Clock present then this indicator will not light. Indicator Status On Flashing Meaning Power on and functional Insufficient power to support Network No C-Bus connected No C-Bus Clock Signal present Further debugging of possible Network problems can be achieved with the Clipsal C-Bus Network Analyser tool (5100NA). 8.2 Unit Indicator This indicator shows the status of the individual unit. When C-Bus is supplied to the unit, OK will be displayed (continuous green light). If any of the four channels have been toggled (using Override facilities) into a state other than is present on the C-Bus network, this indicator will flash with a 90% ON duty cycle. This applies to either Local or Remote Override inputs. Indicator Status On Flashing Meaning Normal operation Unit in override mode No C-Bus connected 9.0 C-Bus System Clock The 5504AMP Series C-Bus Four Channel Analogue Output Unit incorporates a software selectable C-Bus System Clock. The System Clock is used to synchronise data communications waveforms on a C-Bus Network. At least one active C-Bus System Clock is required on each C-Bus Network for successful communications. No more than three units on any C-Bus Network should have Clock circuitry enabled, so this option should normally be disabled using the C-Bus Installation Software. If a System Clock is required, it can be enabled from the Global Tab on the Graphical User Interface (GUI) for the unit. Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 7

10.0 Power-Up Load Status All C-Bus units have onboard non-volatile memory, which is used to store the operating state of the unit in case of power loss. On restoration of power the DIN Rail unit initiates a short power-up diagnostic routine, which lasts for approximately 5 seconds. User programmable options will then allow the analogue output status to be set as desired. For further information about the programming this and other C-Bus units, please refer to the C-Bus Technical Manual (5000S/2, 5000M/2). 11.0 C-Bus Power Requirements The 5504AMP Series C-Bus Four Channel Analogue Output Unit is available in P variants only, which draw 22mA from the C-Bus Network regardless if connected to the mains supply. The 5504AMP Series products do not source current to the C-Bus Network. Adequate C-Bus Power Supply Units must be installed to support the connected devices. If in doubt, consult the C-Bus Calculator (Network Design Verification Software Utility) before proceeding with the hardware installation. 12.0 Stand-Alone Programming The 5504AMP Series C-Bus Four Channel Analogue Output Unit can be programmed without a mains connection. The unit can be connected to any operational C-Bus Network that is capable of supporting one or more extra C-Bus units (22mA current required). The unit can then be configured using the C-Bus Installation Software. The analogue output will only function when a mains connection is made. 13.0 Power Surges and Short Circuit Conditions The mains voltage must be limited to the range specified for any unit which is mains powered. Each Unit incorporates transient protection circuitry. Additional external power surge protection devices should be used to enhance system immunity to power surges. It is strongly recommended that overvoltage equipment such as the Clipsal 970 be installed at the switchboard. 14.0 Megger Testing Megger testing must never be performed on the C-Bus data cabling or terminals as it may degrade the performance of the Network. Megger testing of mains wiring of an electrical installation that has C-Bus Units connected will not cause any damage to C-Bus Units. Since C-Bus Units contain electronic components, the installer should interpret megger readings with due regard to the nature of the circuit connection. Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 8

15.0 Standards Complied DECLARATIONS OF CONFORMITY European Directives and Standards Models L5504AMP & LE5504TAMP comply with the following: European Council Directives Standards Title 89/336/EEC EMC Directive EN 55022 EN 55024 BS/EN 61000-4-2 BS/EN 61000-4-3 BS/EN 61000-4-4 BS/EN 61000-4-5 BS/EN 61000-4-6 BS/EN 61000-4-11 IT Equipment - RFI Emissions Standard IT Equipment - RFI Immunity Standard Immunity to ESD Immunity to RFI Immunity to EFT Immunity to Surge Voltages Immunity to Conducted RF Currents Immunity to Voltage Dips & Interruptions 73/23/EEC Low Voltage Directive EN 61558-1 EN 61558-2-6 Safety of Power Transformers General Requirements Safety of Power Transformers Particular Requirements Australian/New Zealand EMC & Electrical Safety Frameworks and Standards Model L5504AMP complies with the following: RCM Framework Standards Title EMC AS/NZS CISPR22 EN 55024 BS/EN 61000-4-2 BS/EN 61000-4-3 BS/EN 61000-4-4 BS/EN 61000-4-5 BS/EN 61000-4-6 BS/EN 61000-4-11 Electrical Safety AS/NZS 3100 AS/NZS 61558-1 AS/NZS 61558-2-6 IT Equipment - RFI Emissions Standard IT Equipment - RFI Immunity Standard Immunity to ESD Immunity to RFI Immunity to EFT Immunity to Surge Voltages Immunity to Conducted RF Currents Immunity to Voltage Dips & Interruptions General Requirements for Electrical Equipment Safety of Power Transformers General Requirements Safety of Power Transformers Particular Requirements Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 9

16.0 Programming Requirements The 5504AMP Series C-Bus Four Channel Analogue Output Unit must be programmed to set a unique identification (Unit Address) and mode of operation on the C-Bus Network. C-Bus Installation Software v2.2.0 (or higher) can be used to configure the: Project Name Part Name Unit Address Clock (Enable/Disable) Analogue Output Relationships Other Advanced Operating Parameters (e.g. Logic Relationships, Turn-On Thresholds, Power Fail Options etc). The latest C-Bus Installation Software can be downloaded from the Clipsal Integrated Systems Web Site (www.clipsal.com/cis). For further information about programming this and other C-Bus units, please refer to the C-Bus Technical Manual (5000S/2, 5000M/2). 17.0 Important Warning The use of any non-approved software in conjunction with the hardware installation without the written consent of Clipsal Integrated Systems may void any warranties applicable to the hardware. 18.0 Mechanical Specifications 72 65 85 All dimensions are in millimeters. No user serviceable parts inside. Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 10

19.0 Electrical Specifications Catalogue No. L5504AMP LE5504TAMP Nominal Supply Voltage Frequency Range(s) C-Bus Supply Voltage AC Input Impedance Electrical Isolation Status Indicators Maximum Number of Units on a Single C-Bus Network Output Voltage Range Output Rating - Sourcing Output Rating - Sinking Quiescent Power Warm Up Time Restart Delay Network Clock Dimensions 220-240V~ 47-53Hz and 57-63Hz 110-120V~ 15-36V DC @ 22mA required for programming. Does not source current to the C-Bus Network. 50kΩ @1kHz A maximum of 50 units may be connected on a single C-Bus Network 3.75kV RMS from C-Bus to Mains C-Bus Indicator Voltage 20V DC Voltage < 20V DC Voltage < 15V DC Unit Status Indicator On Flashing Load Indicators (4) Clock Present On Flashing C-Bus Power Present Present Fail Load indicator is On when analogue output is on 50 0 (±0.5) to 10 (±0.5) VDC 2.5mA (i.e. minimum of 4kΩ) 15mA at Vout = 0V 8mA at Vout = 10V 10 Watts 5 seconds i.e. I = 15-(0.7*Vout)mA 0 seconds to 42 minutes and 30 seconds Software selectable 72 x 85 x 65 mm No Clock Present Conditions Normal Operations At least one channel in Local or Remote Override mode C-Bus power not available Remote Override Remote switch input can be daisy chained to a maximum of 50 units and a maximum of 1000m of cable Mains Terminals Accommodates 2 x 1.5mm 2 or 1 x 2.5mm 2 Weight C-Bus Connections Operating Temperature Range Operating Humidity Range 245g 2 x RJ45 sockets 0-45 0 C 10 95% RH Copyright 2003 Clipsal Integrated Systems Pty Ltd. Page 11

Further Information For further information about configuring this product and other C-Bus devices, please consult the documentation supplied. Further assistance can be obtained as follows: C-Bus Manuals The 5000M/2 C-Bus Technical Manual provides a comprehensive and definitive guide to Clipsal C-Bus. Includes hardware and software specifications, product datasheets, system design and installation guides, and software overview with fully worked programming examples. C-Bus Installation Software The 5000S/2 C-Bus Installation Software (includes 5000M/2 C-Bus Technical Manual) may be used to unlock the power and flexibility of Clipsal C-Bus. Unit operation may be completely customised to suit user requirements. Advanced control functions may be programmed. C-Bus Installer Training Courses Contact your nearest Clipsal Integrated Systems Sales or Technical Support icer and enquire about Clipsal C-Bus Installer Training and Certification Programs today!! Technical Support and Troubleshooting For further assistance, please consult your nearest Clipsal Integrated Systems Sales Representative or Technical Support icer. Technical Support Hotline 1 300 722 247 (Cost 25 per call, Australia Only) Technical Support Email techsupport.cis@clipsal.com.au Sales Support Email sales.cis@clipsal.com.au Clipsal Integrated Systems Website clipsal.com/cis Products of Clipsal Integrated Systems Pty Ltd ABN 15 089 444 931 Head ice 12 Park Terrace, Bowden South Australia 5007 International Phone +61 8 8269 0560 International Fax +61 8 8346 0845 Internet clipsal.com/cis E-Mail cis@clipsal.com.au 1036469