INSTRUCTION GUIDE DIGITAL CONTROLLER

Similar documents
INSTRUCTION GUIDE DIGITAL CONTROLLER

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL

Accent User. Version. Rheem. PO Box 146, ABN:

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

CG Series Digital Temperature Controller OPERATIONS MANUAL

Operating instructions Control MIKE 3 - CE for MEIKO dishwashers

Operating Manual PU-27 Control Panel

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

Product Manual SZ1145

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

PRODUCTS. Operating Manual

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

Product Manual SZ1144

Carbon Monoxide Transmitter

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

Dryer Master Inc. Dryer Master AM 3. Product Manual

TC515 and TC600 Installation Manual. a Winters company

INSTALLATION AND OPERATION MANUAL

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

TAYAMA R. User Manual Watt Countertop Induction Cooker Model TIH-1500X. Tayama Appliance USA Inc.

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

Programmable Interactive User Manual

Operating points for attention. Installation points for attention

- Data Brochure Universal Reset Module 423

SAS803WHL-7 Thermostat for floor heating

B-40/B-41 Modulating Temperature Controller

Operating Manual UV Monitor UVT 18

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

INSTALLATION AND OPERATION MANUAL

Operation Manual. Programmable Logic Controller

2017 products.koer.com Page 1 of 14

Service Manual Models:

Oven Control System Operation - Ver 2.8

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Model 5060/5070. Letter Opener Revision 3 Brush Transport

Equipment Information

ENVI Boiler Controller

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Control Panel PU-27. Operating Manual. Ver

Operation manual. Control panel PU-27. v

- Data Brochure Universal Reset Module 422

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Emerson Blue Easy Set 1H/1C

Thermometers and temperature controllers

MVE TS Controller (Touch Screen)

General information. Technical data...2 General information...2. Description. Installation

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Your Daikin Altherma remote controller

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Sensor Control Panel

Vehicle Security System VSS3 - Vehicle original remote. Setting Guide - English

PC15CP PUMP CONTROLLER

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Control solutions Biofloor

Programmable Thermostat

Set & $ave. Model Programmable Thermostat. installation and operation manual

Digital Moisture Control Thermostat

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

Quickheat 30 weather compensated boiler control

Installation and operation manual

TPMS1309P05. User Manual

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Marvel S MICROPROCESSOR CONTROLLER. Installation, Operation and Maintenance Manual Effective October 2018 DISCONTINUED. For Reference Only

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

TWLC - Tempered Water Logic Controller. The Intelligent Control

2-ZONE EASYFIT INTRUDER ALARM

Using the. Ducted Gas Central Heating Dual Cycle Refrigerated Air Conditioning Ducted Evaporative Air Conditioning. with your.

Technical Seminar HL-BD82S. Electric Built-In Oven. Panasonic Canada 2013

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Type 750HT Flux Rebaking Ovens

Model Universal Oil Primary Control

AC&R Controller RWR Basic Documentation VR2002 for water to water heat pump units

Service Manual Models:

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

Follett Performance Plus

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

ROYALTON SS1 & SS2 RRH OVEN

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Operating Functions Temperature Parameters

Model: Available in: Sapphire Black and Glacier White. 1 Series

MENU. Steamist Xenio Sauna Control, Product: 0941 and 0942 Model: S170-1 and S Steamist Xenio Sauna Control. Contents

5700-E Sediment Filter Installation & Start-Up Guide

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

RCS Residential Control Systems Inc.

ReFreeX H426V1 User manual

INITIALIZATION / INSTALLATION

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

Transcription:

INSTRUCTION GUIDE DIGITAL CONTROLLER READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING EQUIPMENT

TABLE OF CONTENTS Features & Startup... 3 Powering On & Warming Up Operating the Controller... 4 Combo Hot Knife Machines Troubleshooting Guide... 5 2

FEATURES & START UP The is a programmable digital controller designed to control adjustable machine settings with the easy to use control pad. The digital controller is configured to control impulse or hot knife L Sealers equipped with or without a shrink tunnel. 1 MENU SCREEN (1) The Menu Screen displays the programmed machine settings. NEXT (2) The NEXT button navigates through menu options. 2 3 4 5 DOWN/UP (3/4) Both the & keys are used to make changes to individual variables within the menu options. By pressing the key, the value of the menu option will increase, and pressing the key will decrease the value. ESC (5) The ESC key gives the operator access to the parameters. When in the RUN, or home menu screen, the ESC key is used to access the parameters. To exit the parameter screen, the ESC key is used to return back to the RUN screen. After 10 seconds of inactivity the display will automatically revert to the RUN or home screen. POWERING ON AND WARM UP If the machine is connected to service power, and the ON/OFF switch is OFF, the menu screen will read OFF. When the ON/OFF switch is ON, the machine is beginning the warming up process. These are the screens that will show in the warm up mode: For L Sealer Impulse Wire Machines the menu screen will change from OFF to RUN, and is ready to begin the packaging process. For L Sealer Hot Knife Machines the menu screen will read MACHINE ELEMENTS WARMING UP, PLEASE WAIT. For L Sealer Shrink Tunnel Combination Systems with Impulse Wire the menu screen will read MACHINE ELEMENTS WARMING UP, PLEASE WAIT until the Tunnel Temp reaches the factory default or set point. For L Sealer Shrink Tunnel Combination Systems with Hot Knife the menu screen will read MACHINE ELEMENTS WARMING UP, PLEASE WAIT. Upon reaching the temperature set points, the home screen will read RUN. The operator may now begin the packaging process. 3

OPERATING THE CONTROLLER BELOW DESCRIBES MENU SETTINGS FOR COMBINATION HOT KNIFE MACHINES SEAL TIME SEAL TIME is the amount of time the magnets hold the seal bars in the sealing position. This setting ranges from 0 to 2 seconds. The factory default setting is 1 second. SIDE SEAL TEMPERATURE This menu option shows two temperature readings for the hot knife crossing the path of the seal conveyor. The first temperature reading is the Set Point (SET), the second temperature reading is the Actual temperature (ACT). The factory default setting for the Set Point is 315 F., and the Max setting is 425 F. Press the or keys to decrease or increase the value of the menu option. FRONT SEAL TEMPERATURE This menu option shows two temperature readings for the hot knife running parallel to the seal conveyor. The first temperature reading is the Set Point (SET), the second temperature reading is the Actual temperature (ACT). The factory default setting for the Set Point is 315 F, and the Max setting is 425 F. Press the or keys to decrease or increase the value of the menu option. SEAL CONVEYOR RUN TIME The SEAL CONVEYOR RUN TIME is the time the sealing conveyor runs after the seal has been made to transfer the product away from the seal area and/or into the Shrink Tunnel. The factory default setting is 2 seconds on a scale from 0 (Off) to 10 (Max) seconds. Press the or keys to decrease or increase the value of the menu option. TUNNEL CONVEYOR SPEED The factory default setting is set at 5 on a range from 0 (Off) to 10 (Fast). Press the or keys to decrease or increase the value of the menu option. **On retrofit kits, the Conveyor Speed is controlled by a knob on the control panel.** SEAL CONVEYOR SPEED The factory default setting is set at 5 on a range from 1 (Very Slow) to 10 (Fast). Press the or keys to decrease or increase the value of the menu option. **On retrofit kits, the Conveyor Speed is controlled by a knob on the control panel.** TUNNEL TEMPERATURE This menu option shows two temperature readings. The first temperature reading is the Set Point (SET), the second temperature reading is the Actual temperature (ACT) in the tunnel. The factory default setting for the Set Point is 300 F. The TUNNEL TEMPERATURE has a Max setting of 350 F. Press the or keys to decrease or increase the value of the menu option. 4

ALARMS & TROUBLESHOOTING TROUBLESHOOTING GUIDE FOR HOT KNIFE MACHINES L SEALER AND COMBINATION SYSTEMS 1 There are four (4) alarms that can occur anytime the controller is powered. The L Sealer will not operate during any of these alarm conditions. The alarms will show on the screen until the solution is fixed. 1. FRONT KNIFE HEAT SIGNAL LOST, CHECK RTD This alarm signals when the RTD for the front hot knife is disconnected or malfunctioning. The front knife is the knife closest to the operator running parallel to the face of the machine. Call a local Heat Seal distributor to properly diagnose and fix this issue. 2 2. SIDE KNIFE HEAT SIGNAL LOST, CHECK RTD This alarm signals when the RTD for the side hot knife is disconnected or malfunctioning. The side knife is the knife running across the seal conveyor and parallel to the side of the machine. Call a local Heat Seal distributor to properly diagnose and fix this issue. 3 3. TUNNEL HEAT SIGNAL LOST, CHECK RTD This alarm signals when the RTD for the tunnel is disconnected is malfunctioning. Call a local Heat Seal distributor to properly diagnose and fix this issue. 4 4. MACHINE ELEMENT TEMPERATURE OUT OF SPEC, PLEASE WAIT This alarm will signal when either the front knife, side knife, or tunnel temperatures are out of spec. OUT OF SPEC refers to the temperature being more than 10-15 F above or below the set point. Press ESC on the RS-5 Plus digital controller to diagnose whether the front knife, side knife, or tunnel temperature is causing the alarm. Then, call a local Heat Seal distributor to properly diagnose and fix this issue. 5