Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Similar documents
Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

TA-300, TA-300-LF, TA-350, TA-350-LF

MEGATRON MODEL 2, 3, 4, and 5

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

HOT INLET COLD INLET INSTALLATION

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OUTLET LEONARDH THERMOSTATIC INSTALLATION

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

OUTLET LEONARD THERMOSTATIC INSTALLATION

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

MODEL 210, 210-LF THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUCTIONS

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

MEGATRON MODEL TA, TA-LF

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

Installation S

Installation S

Installation S

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

Installation S

Installation S

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Installation Manual. Models 99168, 99169, 99170

1. Connect Hose Attach a garden hose to the swivel nut hose fitting.

Installation Instructions / Warranty. Metris 31060XX XX XX1

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Troubleshooting the MPH 24FP Series Pedestal Hydrant

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

Installation Instructions

Model Combination Shower Eye/Face Wash

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

TUB AND SHOWER FAUCET

Installation & Operation Manual

Installation Instructions / Warranty

INSTRUCTION MANUAL HS-229G

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions


SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

Model /8320CRP Shower and Eye/Face Wash

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

Instruction Manual. Cheese Warmer with Pump

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Model /8300CRP-8309CRP Shower & Eye/Face Wash

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

1. Connect Hose Attach a garden hose to the swivel nut hose fitting.

Model 7656WCC Eye/face Wash

Installation Instructions / Warranty

Installation Instructions / Warranty

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

INSTALLATION, OPERATION AND MAINTENANCE

TMV45 & TMV80 Standard Thermostatic Mixing Valves

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Installation Instructions / Warranty. Massaud

Installation Instructions / Warranty

Peerless Partner PV Series Indirect Fired Water Heater

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

PALARRE, ROCHELLE WATER-GUARD VITREOUS CHINA SIPHON JET TOILET

INSTALLATION & TESTING MANUAL

OPERATIONS MAINTENANCE MANUAL

Installation Instructions PP-AS20 Anti-Scale System

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

MINIATURE THERMOSTATIC VALVE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Transcription:

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet Angle Checkstop Angle Checkstop Hot Water Inlet G3700LF Cold Water Inlet Installation 1. Install valve in a location where it may be easily cleaned, adjusted or repaired. 2. Inlets are clearly marked on valve body casting. Connect hot water to inlet marked HOT and cold water to inlet marked COLD. 3. Included angle checkstops must be installed on both supply lines. 4. Use solder or pipe cement sparingly. Flush supply pipes before connecting valve. Flush outlet pipe and valve once valve is connected. Maximum operating pressure is 125 PSI (860 KPA) for hot and cold water. Maximum hot to cold water pressure differential is 5%. Note: Should piping be exposed to excessive hot or cold conditions, it may be necessary to insulate piping to prevent freezing or scalding water. IMPORTANT: THESE SYSTEMS ARE DESIGNED TO PROVIDE MIXED WATER FROM 60 TO 90 F (15 TO 32 C) FOR EMERGENCY EQUIPMENT APPLICATIONS ONLY IN ACCORDANCE WITH ASSE 1071. rev. 1215 / 2015 1

Adjustment and Service Guardian thermostatic mixing valves may be easily cleaned, adjusted and repaired. Servicing may be possible without disconnecting valve. To Reset Adjustable High Temperature Limit Stop: Set Screw Pointer Stop Screw Snap Cap 1. Loosen set screw. Remove snap cap, pointer screw, washer, and pointer. 2. Activate emergency fixture. 3. Temporarily place pointer on pointer rod and turn handle to the left, allowing cold water to flow. Then, slowly adjust handle to the right until the required maximum temperature is reached. Note: Temperatures above 90 F are not recommended. Consult a medical advisor for correct temperature settings. 4. Once maximum temperature has been reached, remove pointer and replace on pointer rod such that its right edge rests against the stop screw located on the right side of the cover. 5. Tighten set screw and replace washer, pointer screw, and snap cap. Hold a thermometer under water flow to verify maximum temperature has been set appropriately. Then set desired operating temperature. Note: Thermostatic water mixing valves are regulating mechanisms which must be regularly maintained to provide best performance. Local water quality and usage conditions dictate cleaning frequency. (See Maintenance Guide and Record card included with valve shipment and reference ANSI Z358.1) WARNING: THIS THERMOSTATIC MIXING VALVE HAS AN ADJUSTABLE HIGH TEMPERATURE LIMIT STOP WHICH MUST BE CHECKED. IF TEMPERATURE IS TOO HIGH, THE INSTALLER MUST RESET THIS STOP IMMEDIATELY. ALWAYS CHECK THE TEMPERATURE OF THE MIXED WATER WHEN THE LEVEL HANDLE IS TURNED TO FULL HOT. THE WATER TEMPERATURE OF EACH INDEPENDENT OUTPUT MUST BE CHECKED IF USING A COMBINATION UNIT. EXCESSIVE HOT WATER TEMPERATURE IS DANGEROUS AND MAY CAUSE SCALDING. THE HIGH TEMPERATURE LIMIT STOP IS FACTORY SET AT APPROXIMATELY 90 F (32 C) WITH AN INCOMING HOT WATER SUPPLY TEMPERATURE OF 135 F (57 C). IF THE INCOMING HOT WATER IS HIGHER THAN 135 F (57 C), THE VALVE (WHEN TURNED TO FULL HOT) WILL DELIVER WATER IN EXCESS OF 90 F (32 C) AND THE HIGH TEMPERATURE LIMIT STOP MUST BE RESET. Troubleshooting Symptom Component Type Part No. Description Leak at pointer rod. Packings and Gaskets MU-5A O-Ring Leak between valve cover and body. Packings and Gaskets TM-21/50 Flange Packing Valve outlet temperature will not mix Port Sleeve Assembly TGM-1/50M or Port Sleeve Assembly or Repair Kit consistently. RK3800A After cleaning or replacing port Thermostat Group TGM-2/50 or Thermostat Group or Repair Kit sleeve assembly, valve will not hold temperature. RK3800A Hot water bypass into cold line. Checkstops Supplies cannot be shut off completely. Checkstops RK3800B Checkstop Kit Leak at checkstop bonnet. Checkstops If installed on a circulated hot water system, verify the valve is piped according to Required Piping Method on page 3. See page 5 for complete parts breakdown and parts kits. rev. 1215 / 2015 2

Required Piping Method Required when hot water must be circulated to a thermostatic mixing valve that is a substantial distance from the hot water source. Recommended hot water inlet temperature is 135 F (57 C). Hot Inlet Cold Inlet Hot Supply Cold Supply To Hot Water Source G3700LF This unit must be cycled each time the emergency equipment is inspected (See ANSI Z358.1, Maintenance and Training Section). 1. Set the thermostatic mixing valve to full hot. 2. Activate emergency equipment and allow temperature to reach set point. 3. Turn thermostatic mixing valve to full cold and wait ten seconds. 4. Turn thermostatic mixing valve to full hot and wait ten seconds. 5. Verify outlet temperature does not exceed 90 F (32 C). 6. Turn thermostatic mixing valve to full cold and wait ten seconds. 7. If necessary, adjust high temperature limit stop (see page 2). Then set mixing valve to desired operating temperature and deactivate emergency equipment. rev. 1215 / 2015 3

To Dismantle Valve: Shut off hot and cold water supplies to valve. Loosen set screw. Remove snap cap, pointer screw, washer, pointer and friction spring (see Figure 1). Remove cover screws and cover (thermostat and gears are attached to cover). When reassembling, insert flange packing into valve body and replace cover and cover screws. Then replace friction spring, pointer, washer, screw, and snap cap. After replacing parts, pointer must be reset. Refer to page 2 instructions To Reset Adjustable High Temperature Stop. To Clean Port Sleeve Assembly: Screw (twist) the check nut away from valve body towards port sleeve assembly. Then twist port sleeve nut away from port sleeve assembly (towards valve body) to release port sleeve and thimble (Figure 2). Clean with non-corrosive agent and soft cloth. DO NOT USE ABRASIVES. Wash parts thoroughly after cleaning and reassemble. Install port sleeve with elongated holes nearest the check nut and tighten port sleeve nut against port sleeve assembly. DO NOT OVERIGHTEN. Tighten check nut against valve body. Driving ball on thermostat group should then be inserted into ball socket for final reassembly (Figure 1). To Replace Pointer Rod With Gear: Loosen set screw and remove snap cap, pointer screw, washer, pointer and friction spring (Figure 1). Remove cover screws and cover. Then remove coil sleeve stud and thermostat group. Replace pointer rod with gear, and reassemble. To Replace or Clean Thermostat Group: See To Replace Pointer Rod with Gear (above) to disassemble valve. Clean any collected deposits from thermostatic coil with brush and non-corrosive cleaning solution. Figure 1 Pointer Pointer Rod with Gear Figure 2 Friction Spring Cover Pointer Set Screw Coil Sleeve Stud Driving Ball Thimble Ball Socket Elongated Holes (nearest the check nut) Flange Packing and Cover Screws Check Nut Port Sleeve Port Sleeve Nut rev. 1215 / 2015 4

Thermostatic Mixing Valve Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 RK3800A Repair Kit Checkstop Parts Repair Kits 16 18 17 26 25 20 16 17 18 19 20 21 22 23 24 25 26 RK3800B Checkstop Kit Repair kit Includes parts to repair both hot and cold checkstops Lockable Pointer (suffix LTR ) Notes: TM-36 Set Screw 1. After installing new parts, the adjustable high temperature limit stop must be reset (see page 2). 2. All G3700LF valves are furnished with a lockable pointer. Item Part No. Description 1 57-L Snap Cap 2 TM-29/29A Pointer Screw 3 TM-25C Pointer 4 30 Friction Spring 5 615 Dial Plate 6 TM-25D Stop Screw 7 TM-16 Cover Screws (6) 8 TM-15B/50 Cover 9 TM-21/50 Flange Packing 10 TGM-2/50 Thermostat Group 11 TGM-1/50M Port Sleeve Assembly 12 TM-3/50M Port Sleeve Nut Assembly 13 TM-8 Coil Sleeve Stud 14 TM-28A Pointer Rod Item Part No. Description 15 MU-5A O-Ring 16 03 Lower Stem & Packing 17 011 Spring (Hot Side) 015 Spring (Cold Side) 18 MU-5A O-Ring 19 MU-4A Upper Stem 20 05 Packing 21 02 Bonnet 22 04/50 Swivel 23 09/50 Swivel Nut 24 06 Strainer Cap 25 014 Cap Packing 26 013 Screen rev. 1215 / 2015 5

Flow Capacities 50 G3700LF System Pressure Drop (PSI) 37.5 25 12.5 0 12 18 24 30 36 42 48 54 60 Flow Rate (GPM) MODEL IN OUT G3700LF 3/4" 1" MINIMUM FLOW (GPM) INTERNAL COLD WATER BYPASS MINIMUM SYSTEM PRESSURE DROP 5 10 15 20 25 30 35 40 45 PSI L/MIN 0.3 0.7 1.0 1.4 1.7 2.1 2.4 2.8 3.1 BAR 3 20 14 19 25 28 30 33 38 44 51 GPM 11 76 53 72 95 106 114 125 144 167 193 L/MIN MAXIMUM FLOW CAPACITY CAUTION: ALL THERMOSTATIC MIXING VALVES HAVE LIMITATIONS. THEY WILL NOT PROVIDE THE DESIRED ACCURACY OUTSIDE OF THEIR FLOW CAPACITY RANGE. CONSULT THE CAPACITY CHART AND DO NOT OVERSIZE. MINIMUM FLOW MUST BE NO LESS THAN SHOWN ABOVE. IMPORTANT: THESE SYSTEMS ARE DESIGNED TO PROVIDE MIXED WATER FROM 60 TO 90 F (15 TO 32 C) FOR EMERGENCY EQUIPMENT APPLICATIONS ONLY IN ACCORDANCE WITH ASSE 1071. Limited Warranty warrants the original purchaser that its products will be free from defects in materials and workmanship under normal usage conditions, and when properly installed and maintained according to manufacturer's instructions for a period of two years from date of shipment. During the warranty period, will (at its discretion) repair or replace any product or part thereof, which shall be returned, freight prepaid to Guardian's factory and determined by the manufacturer to be defective in materials or workmanship. There are no warranties, expressed or implied, which extend beyond verbiage contained herein. There are no implied warranties of merchantability or fitness for a particular purpose. will not be held liable for labor, incidental or consequential damages. Any alteration or improper installation or improper use of the product will void this limited warranty. rev. 1215 / 2015 6