The superconducting TF magnetic system of Tore Supra

Similar documents
THE TORE SUPRA CRYOGENIC SYSTEM. Design and operation

3.2 Cryoplant and Cryodistribution

A CRYOGENIC TEST STATION FOR SUBCOOLING HELIUM HEAT EXCHANGERS FOR LHC

Air Liquide Advanced Technologies Division Sassenage, 38360, France

AVAILABILITY AND RELIABILITY OF CERN CRYOPLANTS

Testing of prototype coils for the NHMFL 32 T superconducting user magnet

Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK

OPERATIONAL EXPERIENCE ON CRYOGENIC SYSTEMS FOR LARGE-SCALE ACCELERATORS AT CERN

800 MHz US 2 NMR system

Metal hydride storage system for MICE experiment at Rutherford Appleton Laboratory. Technical specification.

Pocket Dilution Cooler

Cryogenic refrigeration for the LHC

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

A Microcryostat for Refrigeration at 1.8 K

Measured Performance of Four New 18 K Helium Refrigerators for the LHC Cryogenic System

Remote Helium Cooling Loops for Laboratory Applications

The dilution process. 4K flange. Still. Heat exchangers. Mixing chamber

Linde Kryotechnik AG. Liquefaction and refrigeration plants for research, science and industry. Helium solutions.

September 11, 2012 Ministry of Economy, Trade and Industry

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

STATUS OF THE LHC EXPERIMENTS.

POWER Selecting Shell Side Design Temperature for Feedwater Heaters

Concept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

Product Manual SZ1145

EU Diagnostics: Recent progress & near-term opportunities. Frederic Le Guern on behalf of Glenn F. Counsell Programme Manager. 18 th September 2018

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

QA16 Addressable System

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Rules for Intruder Alarm Systems

HELIAL refrigerators. Range of automatic helium refrigerators

TrueAlarm Analog Sensing

S TEM PRODUCT SPECIFICATION

Diamond as potential CryoBLM for the LHC All results are preliminary

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Product Manual SZ1144

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Status and perspectives of the Virgo detector

LARGE CRYOGENIC HELIUM REFRIGERATION SYSTEM FOR THE LHC

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

Liquid Helium Level Instruments

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Forced draught gas burner

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

M2500 Engine Controller Installation Manual

MODELING HEAT TRANSFER FROM QUENCH PROTECTION HEATERS TO SUPERCONDUCTING CABLES IN NB3SN MAGNETS

Refrigeration System with a Capillary Tube and a Thermostat

Pump technology: Improved energy efficiency in refrigeration plants. Dr. R. Krämer

CHASE RESEARCH CRYOGENICS Ltd. World Leaders in sub-kelvin cryogenics

A n hybrid liquid nitrogen system for the cooling. of the ESO O mega C A M detector

OLS26 Aqua Pro Orbital / Linear shaking bath. Offering ultimate flexibility and usability for all applications

Air & Water Heat Pump R832

AQ 100 Series. Arc Flash Protection System

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CWS AIR-CONDITIONERS

Stock Vessels for Improved Quality and Energy Savings

Laser Damage Measurements

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

FLAME AMPLIFIER MODULE 3001D

VACUUM CONTACTOR TYPE SVC-T 32. 7,2 kv A MANUAL FOR MOUNTING, OPERATION AND MAINTENANCE

ACCESS AND ALARM SAFETY SYSTEMS ACTIVITIES FOR THE 2012/2013 LONG SHUTDOWN*

IEEE Transformer Committee PC Distribution Transformer Monitoring - User

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

1.7. Insulation fault evaluators EDS460/490 EDS461/491

M2000 Engine Controller

Induction Billet Heaters with Enthalpy Controlled Zone Heating

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

Antoine Drouart DSM/DAPNIA/SPhN. Köln, 5 th of December,

The ATLAS detector: status of the construction and installation a year before the first p-p collisions at the LHC Collider

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

Development of magnetic pulse crimping process for highdurability

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Part 3 Troubleshooting

THE THERMOSIPHON COOLING SYSTEM OF THE ATLAS EXPERIMENT AT THE CERN LARGE HADRON COLLIDER

15. Heat Pipes in Electronics (1)

Roof top SPACE RPC 450Z R407C M011

Shaking water baths. OLS26 Orbital/Linear shaking water bath. LSB12 & LSB18 Linear shaking water baths

Reliability and availability analysis of a 10 K helium refrigerator

Metal Turbine Exhaust Joints An analysis of metal and fabric GTX expansion joints

1.7. Insulation fault evaluators EDS460/490 EDS461/491

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Air Cooled Chillers & Heat Pumps WinPACK HE-A

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Aquamatic Instantaneous DHW production unit with integrated storage tank

PRODUCT GUIDE

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

AmpLight group management

Ultra cold freezer storage. Risk management guide for research materials

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Forced draught gas burner

ZETA MAGNETIC AGITATORS

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

Transcription:

The superconducting TF magnetic system of Tore Supra (CEA Cadarache) Association EURATOM-CEA, CEA/DSM/IRFM 0

1

1. Introduction TORE SUPRA TF system contribution The revolution of superfluid helium 1.8 K Introduction of a new type of refrigeration for sc on an industrial level Thousands of litres in TS (1988) Hundredths of thousands litres in LHC (2007)! TORE SUPRA Cryoelectricity for magnet systems can be handled together with Plasma Physics in large fusion experiments 2

Introduction GENERAL OBSERVATIONS The toroidal field system of TORE SUPRA is one of the largest superconducting system in operation. It is operated near its nominal characteristics since November 1989. The system is operated daily, the field is increased typically in the morning (8 am), maintained during the whole day long and decreased in the evening around 8 pm. Very good reliability and availability of the refrigerator including for the first time industrial quantities of superfluid helium thanks to the Claudet bath. The non cycled operation of the magnet leads to a simplification in the preparation of the shot. Most of the conventional toroidal field systems of large tokamaks experience on the long run problems connected to the cycling and resulting mechanical fatigue. 3

Introduction The Tore Supra TF magnet during assembly 4

Mains aspects of Tore Supra design Figure shows one module representing 1/6 th of the magnet. It is made of two parts: the inner vault (or coil nose) is massive, the outer one (or coil ears) is made of a divided structure. The coils are electrically insulated from each other by glass epoxy plates while being mechanically locked by insulated shear keys. A module of the Tore Supra TF system (1/sixth of the TF system) 5

Mains aspects of Tore Supra design The machine is composed of identical modules representing 1/6 th of the full torus. The modules, assembled separately, contain the complete succession of torus: inner vessel, thermal shield, magnet system, outer thermal shield, and outer cryostat. After assembly, each torus behaves as a rigid torus, so that forces acting on it are self-restrained. The implication and the advantage is that only the weight has to be supported by components at a different temperature. 6

Mains aspects of Tore Supra design bare conductors in superfluid helium! Superfluid helium (1.8 K) in thin casing Supercritical helium (4.5 K) in thick casing channels Tore Supra TF coil structure 7

Mains aspects of Tore Supra design At the bath temperature (1.8 K), at 1400 A and 9 T the conductor satisfies stability requirements of two kinds: In case of a plasma current disruption, the conductor is subject to field variations in the range of 0.6 T with an associated time constant due to the steel casings of about 10-20 ms. The conductor must not reach at any point a temperature greater than the current sharing temperature. In case of a sudden temperature increase caused by accidental perturbation the conductor temperature can increase above the critical temperature and recover after having reached the following typical values: 30 K for a localized perturbation under one spacer, and 15 K if a whole pancake is affected. 8

Mains aspects of Tore Supra design As a consequence, in the TF coils, the operating point was chosen such as to absorb perturbations and plasma current disruptions. On the load line the critical current is reached at 4.2 K, for the nominal TS values (1400 A and 9 T). Local losses in the conductor in operation and in particular during disruption ( B=0.5 T within 10 to 20 ms) must remain sufficiently small to be absorbed by the very large enthalpy of superfluid helium between 1.8 K and 2.16 K (T λ ): 3 10 5 J/m 3. Not all the conductor lengths are in direct contact with superfluid helium. Thermal temperature gradients arise during heat extraction in the non-wetted parts of the conductor. The current sharing temperature of the project has been adjusted to take into account with a margin the highest temperature during the process of heat extraction. This temperature has been estimated around 3.4 K, which means that the margin compared to the current sharing temperature of 4.2 K is 0.8 K. 9

Mains aspects of Tore Supra design Tore Supra TF system conductor (2.8 x 5.6 mm 2 ) 10

Mains aspects of Tore Supra design Current [A] 4000 3500 3000 2500 2000 1500 1000 500 0 1400 A, 9 T 6 7 8 9 10 11 12 13 14 Field [T] Large margin load line Ic (T=4.2 K) Ic(T=1.8K) 2.4 K Temperature margin on the TF system of TS on all the coils except BT19 Operation point Critical point 11

12

Phase diagram of water (To be compared with helium) 13

Acceptance tests Before assembly at CEA Saclay The acceptance tests of the coils before assembly were performed at CEA Saclay. Three objectives have been assigned to these experiments: Test of the prototype coil which was specially equipped with small heaters to induce a quench, and voltage taps to study the propagation of the normal zone. Test of the 18 coils of the torus Test of the equipment used for cooling and the electrical systems as pumps, superfluid heat exchangers, safety valves, leads and electrotechnical equipments. 14

Acceptance tests Test of the prototype coil at CEA Saclay - Observation on strain gages during cooling down - Increase of current up to nominal current ( 1400 A) - Fast discharge with a time constant of 14 s (1750 V) - Initiation of a quench by a resistive heater and observation of the quench characteristics (main result: quench propagation within 3 s) Main problems - burning of a switch (wrong time control in the electronic system - damage to the current breaker due to stray magnetic field - transition because of operation at very low pressure (saturation pressure) (failure of cold valve opening during cooling down) 15

Acceptance tests Tests of the series coils at CEA Saclay tests before energizing - 8 kv dc to the ground for one minute at room temperature - 4 kv to the ground in superfluid helium with current leads connected - tightness tests of the thin casing after cooling down tests in current - first check tests at 120 A - 1400 A (5.4 T) with no training in all coils (9 T in TORE SUPRA) - 1750 V across the coil during FSD (half nominal voltage) 16

Acceptance tests Tests of the whole system at CEA Cadarache - insulation tests - tightness tests (thin casing), - tests at 120 A, - operation at reduced current 600 A associated with first campaign of TORE SUPRA. short circuit on BT17 Replacement of BT17 by prototype coil transformed in spare coil - change of safety system principle - update of quench detection system and of system monitoring - acceptance tests by step (120 A, 600 A, 800 A, 1000 A, 1250 A, 1450 A) FSD at each step - observation of abnormal behaviour on BT13 with eventually quench during 1450 A FSD. Insulation tests after each (warm up cooling down cycle) of the system : test to the ground of each coil, capacitor discharge on each coil with comparison with previous results, strain measurements (gauges on thick casings) on current cycle. 17

Protection in case of a quench The detectors V P N T I Voltage (V) Cold pressure (Pa) Cold Liquid In cold valve region (K) Temperature near Current lead cryostat (K) Ground current (A) Thereshold level <2. <2. 10 5 >1.95 <2.05 50. Time delay 1. 0.5 2 2. 0.5 (s) 18

Protection T Location of the two temperature detections N 19

Protection Evolution of the discharge circuit after damage of coil BT17 (two cells) Rs=2.5 Ω Original protection design Rs=0.417 Ω Rcoil=0.5Ω Within 3s in case of a quench Rc=0.833 Ω New protection design 20

Protection Tore Supra TF system FSD resistor 21

Protection The rearrangement of the discharge circuit from a series circuit to a series/parallel circuit has allowed to decrease the voltage across the coil by a factor of ten. - in case of a FSD without a quench the voltage across the coils is low (390 V instead of 3500 V) and the time constant of the discharge is long 122 s. - in case of a real quench, the electrical circuit is affected by the resistance of the quench coil which is rapidly (3s) at a value around 0.5 Ω decreasing automatically the time constant discharge of the quenched coils around 14s, which is adequate to protect it. Unbalance of current between coils and associated shear forces have been studied and accepted. 22

Unique quench in TORE SUPRA Coil BT04 23

Unique quench in TORE SUPRA Coil BT04 24

Protection Check of the quench detection system This check is performed daily and automatically on the three main quench detections (T,P,V). As concerns the temperature detection the alarm must be triggered on every coil during the night warming up. This transition is automatically checked afterwards every day, attesting the good behaviour of the whole detection system. For the pressure and the voltage detections the test is made by simulating a quench signal and checking that it is well detected. An additional test is made on the voltage detection to ensure that the time delay is well respected and that the detection cannot be triggered by a simple electrical noise. 25

Status of the Tore Supra TF system 1982-1988 coil manufacture and magnet assembly all coils tested up to nominal current (1400 A) at Saclay 1988 start of operation short circuit in BT17 during a fast safety discharge 1989 replacement of BT17 by spare coil BT19 acceptance tests of TF coils up to 1450 A (9.3 T) quench of BT13 during fast safety discharge (FSD) limitation of operating current to 1250 A temperature increase observed in BT13 during FSD 1995 disappearance of defect on BT13 no more temperature increase in BT13 during FSD 2002 continuous data acquisition system 26

Status of the TORE SUPRA TF system No more apparent problem on BT13 Coil temperature (K) 2.15 2.10 2.05 2.00 1.95 1.90 1.85 1.80 1.75 1.70 Thick casing coil helium temperature BT13 Temperature BT16, BT17 Temperatures 6.4 6.2 6 5.8 5.6 5.4 5.2 5 4.8 4.6 Thick casing helium temperature (K) Temperature increase in coils during FSD (2003) No special cryogenic impact of FSD in BT13 in comparison with the other coils 1.65-500 1500 3500 5500 7500 9500 Time (s) 4.4 Green light for TF operation 1.8 K 27

Normal operation in TORE SUPRA Thermal cycling: 16 thermal cycling were performed since 1988 for the TF system (300 K 1.8 K 300 K) Plasma discharges: 25500 plasma discharges have been performed. Number of TF cycles 800 700 600 500 400 300 200 100 0 0/600 600/900 900/1200 >1200 Range of TF current (A) TORE SUPRA TF activity Since 1988 11000 hours of operation 28

Normal operation in TORE SUPRA Plasma current (MA) and TF current (ka) 1.2 1 0.8 0.6 0.4 0.2 BT15 Temperature TF system current Cleaning Plasma Plasma discharges discharges Long Plasma discharges 1.80 1.78 1.76 1.74 1.72 1.70 1.68 1.66 1.64 BT15 coil temperature (K) Since 2003 continuous data acquisition and record on TF sensors available Better system monitoring is possible 1.62 0 5 7 9 11 13 15 17 19 21 23 Temperature increase linked to TF current increase (0.06 K) Time ( h ) 1.60 Green light for TF operation 1.8 K BT 15 temperature during one day of operation 29

Normal operation in TORE SUPRA 1.2 TF system current 5.00 Plasma current (MA) and TF current(ka) 1 0.8 0.6 0.4 0.2 Thick casing helium temperature Cleaning Plasma discharges Plasma discharges Long Plasma discharges 4.90 4.80 4.70 4.60 4.50 Thick casing helium temperature (K) Thick casing helium temperature during one day of operation 0 5 7 9 11 13 15 17 19 21 23 Time ( h ) 4.40 Temperature increase linked to cleaning plasma discharges 30

Normal operation in TORE SUPRA Green light for TF operation 1.8 K Plasma disruption 1600 1400 1200 1000 TS#31828 5.5 1.725 800 600 I P (ka) Thick casing helium temperature (K) 5.4 5.3 5.2 5.1 5 4.9 4.8 4.7 4.6 4.5 Thick casing helium temperature -50 50 150 250 350 450 time (s) Coil temperature 1.72 1.715 1.71 1.705 1.7 1.695 Coil temperature (K) 400 200 0-200 -400 di P /dt (MA/s) 2.69 2.70 2.71 2.72 2.73 2.74 s Cryogenic impact due to a disruption from 1.7 MA 0.02 K for coil 0.83 K for thick casing 31

Main problems in operation: FAST SAFETY DISCHARGES Every year several FSD in the TF system. They are not associated to a quench of any coil. A lot of attention was devoted all along these 16 years to decrease the number of these FSD. During FSD the coils experience the largest voltage in operation (320 V corresponding to 1400 A). The weak point of the system is the presence of bare conductors and the associated possibility of short circuits FSD have to be avoided FSD induces a thermal load on the system which need on average 2h30 to recover and the operation is correspondingly interrupted. Part of the FSD are associated to electrical perturbations during plasma heating. To mitigate the perturbation on the Tokamak operation an important effort was devoted to make the protection system of TS magnets more insensitive to electrical perturbations. 32

FAST SAFETY DISCHARGES Coil temperature (K) 2.15 2.10 2.05 2.00 1.95 1.90 1.85 1.80 1.75 1.70 1.65 Thick casing coil helium temperature -500 1500 3500 5500 7500 9500 Time (s) BT13 Temperature BT16, BT17 Temperatures 6.4 6.2 6 5.8 5.6 5.4 5.2 5 4.8 4.6 4.4 Thick casing helium temperature (K) 33

Main problems in operation: FAST SAFETY DISCHARGES Number of Fast safety discharges 12 10 8 6 4 2 0 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2001 2002 2003 Number of TF current cycles 3500 3000 2500 2000 1500 1000 500 0 Mitigation of perturbation 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 Using time delays on alarms as long as possible without affecting the protection of the coils in case of a real quench. Important effort in sensors conditioning general protection optimisation 34

FAST SAFETY DISCHARGES Unidentified Command Control Storm Pow er supply Origin of the FSD NBI ICRH Safety system Cryoplant 0 2 4 6 8 10 12 Temperature increase linked to cleaning plasma discharges 35

The cryogenic system of TORE SUPRA Power associated to operation modes 77 K Power 6000 l of N 2 Per day 4.5 K power 1.8 K power Total electrical consumption Magnet operation day Nights between operation days 10 kw 10 kw 900 W 700 W 300 W 0 1100 kw 900 kw Cryoplant fully automatic operated by a team of 12 people Week ends 10 kw 700 W 0 900 kw 0.5 Meuros/year Excluding staff and energy One week shut down 10 kw 0 0 300 kw 36

The cryogenic system of TORE SUPRA The major tendency of the cryoplant ageing Although the preventive maintenance of the compressor units gives a good availability of the refrigerator, after 16 years of operation we can identify the major following tendencies for the cryoplant ageing : - a loss of electrical insulation of many temperature sensors located in the depth of the cryostats. - a drift of adjustment of the electronic components dedicated to the magnetic bearings of the cold compressors. - air leaks in the cryostat vacuum vessel due to the tightness seal ageing. 37

Can the TF magnet experience of TS be useful for ITER? How far are TORE SUPRA and ITER TF systems comparable? TORE SUPRA TF system 600 MJ 1400 A 500 V Superfluid bath No radial plates ITER TF system 40 GJ 68 ka 10 kv Forced flow cooling Conductors in radial plates TORE SUPRA conductor 2.8 x 5.6 mm NbTi ITER model coils conductors 51 x 51 mm =40.7 mm Nb3Sn 38

How far are TORE SUPRA and ITER TF systems comparable? TORE SUPRA operation cannot be simply extrapolated to ITER Forced flow cooling introduces a completely new type of refrigeration This is linked to very high voltage monitoring Forced flow cooling induces a different kind of protection strategy Radial plates solution impose a more difficult operation mode with cold eddy current. FSD contrary to the situation in TS induces a quench Specific solutions have to be developed for ITER 39

How TORE SUPRA experience on TF system is useful for ITER magnet system? Practical demonstration during this 16 years that Plasma Physics is possible with superconducting magnets. ITER decision could probably not be possible without this experience This experience has been transferred during ITER R&D programs for ITER conductor design and coils design by CEA magnet team. Still to be done Experience in TS can help Design of simple and robust protection and monitoring system specificities such as plates and related impact on cryogenics during FSD Double contradictory objective Avoid quench system (40 GJ) (only one quench since 1988 in TS!) Minimize number and effect of FSD because of plates Detailed magnet operation concept, Refrigeration dimensioning as a function operation specifications 40

Conclusion The TORE SUPRA Tokamak is the first important meeting between Superconductivity and Plasma Physics on a large scale. This experience has demonstrated that superconducting magnets can be operated successfully on the long term with plasma physics. Far from being a burden, the continuous operation of the TF system is a simplification in the preparation of the plasma discharges. No significant heat load is associated to long shots. The non pulsed operation of this large magnet system is also an advantage as concerns the mechanics which can have an impact on ageing of insulation. Overall, despite the differences in design and size, the accumulated experience over 16 years of operation is certainly a useful tool to prepare the manufacture and the operation of the ITER magnets. 41