Understanding and Applying NFPA 25

Similar documents
Understanding, Applying and Enforcing NFPA 25. James D. Lake NFSA Director of Training

Slide 1. Slide 2 Instructor. Slide 3. NFPA 25 The Owner s Manual. Roles & Responsibilities DISCLAIMER

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

NFPA 25 and the Influence of Liability

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

9/15/ Cantara Lane Vista, CA (760)

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector Permit

Center for Life Safety Education

Scope of Section 2. AS vs. Application Issues. Schedules & Log- Contents. Books

Koffel Associates, Inc.

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

Subject: Fire Protection Impairment Program Reference: NFPA (see bottom of page 5) Effective Date: August 2014 Distribution All YC Employees

WHEA FSE inspections.

Brighton Area Fire Authority

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

Circulation Report for SIG-TMS Comments Document # 72

Risk Management Services

UNIVERSITY. Facilities Management

The Technical Committee on Commissioning and Integrated Testing

Review of Revisions to NFPA 1, 2015 Edition

Inspection and Testing of Water-Based Systems

NFPA Updates (c) 2015 SSR, Inc. All rights reserved Florida AHCA Conf

INSPECTOR I SKILLS ADMINISTRATION

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/

System Test Report CLEAN AGENT

Title: BFST1505 Syllabus

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

NFPA 72 Code Changes vs 2013

Chapter 4: Fire Protection Systems

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

Design & Construction Standards, Revised January

Written Fire Safety Plans

You are required to READ ALL PAGES. of this application

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Slide 2 NFPA 25: 2017

B. The Facility Emergency Planners and Alternate Planners will successfully complete the in-house DJJ Fire Prevention course.

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Florida Building Code 2010

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

DUQUESNE UNIVERSITY. Fire Protection System Impairment Program (Red etag Permit)

Best Practices Guide. for Residential Fire Sprinklers

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

26 of 128 9/23/2014 9:25 AM

NFPA 80 Overview January 21, 2016

NFPA 96, 2017 REVIEW SUMMARY

D. Reference Standards (Utilize latest editions available):

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

EXHIBIT D ATTACHMENT G - UNIT PRICING DMS-14/15-039B - SIMPLEXGRINNELL, LP FIRE SPRINKLER SYSTEM INSPECTIONS YEARS 1-5

Fire System Impairment Policy

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

PORTABLE FIRE EXTINGUISHERS

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

CENTRAL STATE HOSPITAL PLAN PLANT OPERATIONS UTILITIES MANAGEMENT PLAN

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

THE NATIONAL CODE SERVICES ASSOCIATION (NCSA)

FIRE SPRINKLER SHOP DRAWING SUBMITTAL REQUIREMENTS

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

Winnipeg Fire Department Fire Prevention Branch

SPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.

Established /10/2015. Doran Pruisner Dan Wood

Builders Risk - Fire Prevention Inspection Checklist

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Protecting Your Property: Well Do You Know Your Fire Fire Systems Systems. Joe Szewczyk, Risk Control Consultant

David Stymiest, PE, CHFM, CHSP, FASHE cell Copyright 2014, Smith Seckman Reid, Inc.; All rights reserved

Narrative Reports As Regulated by 780 CMR, Section 903.0

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

Fire Rated Door Assemblies: Compliant Designs

False Sense of Security???

Iowa State Fire Marshal

a high level of operational reliability), and the designer (in performing probabilistic-based

Property protection principles for fire protection

2019 COURSE CATALOG (rev )

Measures (ILSM) Process

Facilities Management

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

Changes in NFPA

Antifreeze Solutions and Automatic Fire Sprinkler Systems. March 12, 2013

Fire Sprinkler Submittal Requirements and Acceptance Testing

Reason for Amendment (Statute, Rule, FBC, Industry) (11)(a)

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

TetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.

MULTI-PHASED FIRE ALARM AND MASS NOTIFICATION SYSTEM UPGRADES: The Authority Having Jurisdiction (AHJ) and Proper Planning

AUTOMATIC FIRE SPRINKLER SYSTEMS

Fire Department Access and Water Supply

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Transcription:

Understanding and Applying NFPA 25 Texas Edition Learning Objectives Describe the scope of NFPA 25. Distinguish between sprinkler system problems that fall within the scope of NFPA 25 and those that do not. Discuss ways to best tdeal with important t concerns outside the scope of NFPA 25. Interpret TX ITM rules and how they compare with the scope of NFPA 25. Identify significant changes to NFPA 25 2014. National Fire Sprinkler Association, Inc. 2014 1 2 Four Questions What are the things the stakeholders in the ITM process (owner, AHJ, & contractor) want to know about a fire protection system? Four Questions 1. Will the system work? 2. How do I know? 3. Why NFPA 25? 4. Who is responsible? 3 4 Will the system work? Sprinkler System Success Rate Public Assembly 96% Educational 93% Health Care 96% Residential 98% Store / Office 96% Manufacturing 93% Storage 79% All Structures 95% Will the System Work? When the system operated, but was ineffective. Source: U.S. Experience With Sprinklers, John R. Hall, Jr., NFPA Fire Analysis And Research, Quincy, MA, September 2010 5 6 1

Will the System Work? How Do I Know? Inspection Testing When the system failed to operate. Maintenance Source: U.S. Experience With Sprinklers, John R. Hall, Jr., NFPA Fire Analysis And Research, Quincy, MA, September 2010 7 8 How Do I Know? How Do I Know? Inspection Testing Maintenance Reasonable degree of assurance that the system will work when its needed Inspection Testing Maintenance Reasonable degree of assurance that the system will work when its needed ITM Reports provide the evidence 9 10 NFPA 25 Documentation ITM reports are the primary source of information about the condition of the system Other documentation is also required NFPA 25 Documentation ITM Reports must contain (per NFPA 25 2014 section 4.3.2): 1. The procedure/activity performed 2. The organization that performed the activity 3. The required frequency of the activity 4. The results and date 5. The name and contact info of the qualified contractor or owner, including lead person for the activity 11 12 2

NFPA 25 Documentation What about things that are outside the scope of NFPA 25? Unsprinklered areas Changes identified Very important to point these things out, but not as part of routine ITM Why NFPA 25? Referenced in all national model building and fire codes Contains all the requirements for an existing system Strives to balance the cost of system maintenance with what provides the best return 13 14 History of NFPA 25 Organization of NFPA 25 Chapters 1 4 Administrative Chapters Chapters 5 13 System Chapters Chapters 14 & 15 Corrective Chapters Chapter 16 Special Requirements from Other NFPA Documents (new in 2014 edition) Annexes A F 15 16 Scope of NFPA 25 1.1 Scope. This document establishes the minimum requirements for the periodic inspection, testing, and maintenance of waterbased fire protection systems, including land based and marine applications and actions to undertake when changes in occupancy, use, process, materials, hazard or water supply that potentially impact the performance of the water based system are planned or identified. Scope of NFPA 25 1.1.3.1 * This standard does not require the inspector to verify the adequacy of the design of the system. 17 18 3

What is not in NFPA 25? Requirement for Engineering Judgment Requirement for Hazard Analysis Requirement for System Certification Chapter 3 Inspection Testing Maintenance Deficiency Impairment Important Definitions 19 20 Definition of Inspection Definition of Testing Inspection Defined as a visual examination to verify that it appears to be in operating condition and is free of physical damage. Testing. A procedure used to determine the operational status of a component or system Follows up on original acceptance tests 21 22 Definition of Inspection Definition of Deficiency Maintenance. work performed to keep equipment operable or to make repairs. Deficiency. For the purposes of inspection, testing, and maintenance of water based fire protection systems, a condition in which a system or portion thereof is damaged, inoperable, or in need of service, but does not rise to the level of an impairment. 23 24 4

Non Critical or Critical Critical Deficiency (2014 ed.) A deficiency that, if not corrected, can have a material effect on ability of the system to function as intended in a fire event. Noncritical Deficiency (2014 ed.) A deficiency that does not have a material effect on ability of the system to function as intended in a fire event, but correction is needed to meet the requirements of this standard Definition of Impairment Impairment. A condition where a fire protection system or unit or portion thereof is out of order, and the condition can result in the fire protection system or unit not functioning in a fire event. Emergency vs. Preplanned 25 26 Classification of Findings Annex E was added in 2011 Moved to Annex A in 2014 Provides guidance for how to classify various issues discovered during ITM process Management of Change 4.1.6* Changes in Occupancy, Use, Process, or Materials. The property owner or designated representative shall not make changes in the occupancy, the use or process, or the materials used or stored in the building without evaluation of the fire protection systems for their capability to protect the new occupancy, use, or materials. 27 28 Management of Change 4.1.6.1 The evaluation required by 4.1.6 shall not be considered part of the normal inspection, testing, and maintenance required by this standard. TX Rules (Current) 34.721. Yellow Tags. (a) If a fire protection sprinkler system is found to be noncompliant with the applicable NFPA standards at the time it was installed or found to contain equipment that has been recalled by the manufacturer, but the noncompliance or recalled equipment does not constitute an emergency condition, a completed yellow tag must be attached to the respective riser of each system 29 30 5

TX Rules (Proposed) 34.721. Yellow Tags. (a) If a fire protection sprinkler system is found to be noncompliant with the applicable NFPA standards at the time it was installed, is not being tested or maintained in accordance with adopted standards, or found to contain equipment that has been recalled by the manufacturer, but the noncompliance or recalled equipment does not constitute an emergency impairment condition, a completed yellow tag must be attached to the respective riser of each system Four Questions 1. Will the system work? 1. How do I know? 2. Why NFPA 25? 3. Who is responsible? 31 32 Who is responsible? There are 3 stakeholders in the NFPA 25 based ITM process Owner Contractor AHJ INFORMATION Stakeholder Responsibilities The owner is the one most responsible The contractor's job is to provide the owner with an idea of the condition of the system(s) to the owner The AHJ s role is enforcement (making sure NFPA 25 is being followed) and sometimes consultation 33 34 Owner Responsibilities Chapter 4 General Requirements Section 4.1 Responsibility of Property Owner or Designated Representative Most owner requirements were combined into 4.1 in the last few cycles of NFPA 25 Owner Responsibilities Section 4.1 Owner is responsible for: Proper ITM of the system Maintaining temperature in the building Providing access to important features Notification of shutdown Appointing an impairment coordinator Corrections and repairs NOT making changes without evaluation Addressing changes Maintaining records 35 36 6

Scope clarified New Definitions Frequency windows Fire Pump Test Frequency Diesel Fuel Quality Residential Board & Care Valve Status Tests Internal Inspections Frequency windows 37 38 Fire pump frequency Primarily revolves around weekly tests for both Frequencies can be modified with risk analysis Diesel Fuel Quality New requirement in 2014 edition Annual quality tests New Chapter 16 13D systems in small residential board & care ITM rules extracted from NFPA 101 Control Valves Inspect Monthly Gauges Inspect Monthly Alarm Devices Inspect Quarterly Alarm Devices Test Semi Annually Valve Supervisory Switches Test Semi Annually Visible Sprinklers Inspect Annually Visible Pipe Inspect Annually Visible Pipe Hangers Inspect Annually Plus others 39 40 Valve status test Different from main drain Designed to verify whether a valve is closed Main drain test changes Internal inspections New term Assessment of Internal Condition 5 year frequency remains but can be modified FPRF Workshop NFPA held a workshop in December to discuss possible scope changes to NFPA 25 Discussions revolved around wear and tear vs. more thorough h system evaluation Also discussed sprinkler performance 41 42 7

FPRF Workshop Our representatives put the split at approximately 75% in favor of keeping NFPA 25 like it is Most tfeel lthat t changes are best thandled dby the fire code Questions? 43 44 Thank You! Jason Webb Director of ITM National Fire Sprinkler Association webb@nfsa.org 45 8