Ceasefire Watermist Hydrant Systems

Similar documents
Ceasefire s Watermist Compressed Air Foam System. 400 times more power.

WE RE PUTTING FIREFIGHTING ON AUTO-PILOT CEASEFIRE LAUNCHER:

PLUS SIZE EXTINGUISHERS CEASEFIRE PLUS

THE WATERMIST SYSTEM WITH THE POWER OF FOUR. CEASEFIRE QUAD

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

CARTRIDGE EXTINGUISHER

Ceasefire Automobile Firefighters

Ceasefire Kitchen Firefighting Range

THE BIGGEST, SMALLEST FIREFIGHTER. CEASEFIRE MINI. Suppression System

PROTECTS WHAT IS MOST PRECIOUS. CEASEFIRE HOME FIRE EXTINGUISHERS RANGE

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

SMOKE? DARKNESS? PANIC? RELAX!

FIRE STOP 200/30. High technology system for first attack of fire with high pressure nebulized water (Water mist) FD 907. Ed.

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

Element C3.4 Fire Fighting Equipment


I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

What is HI-FOG? The natural enemy of fire

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Your door is all that separates your family from what lies outside

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

automatic FiReFighTing SYSTeMS in PainT booths

Fire fighting with fast deployment units. CRISTANINI Spa Via Porton 5, Rivoli Veronese, ITALY

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

and Sprinkler System in Resalat Tunnel of Tehran

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

FIGHTING FIRE as easy as blowing out a match

Enclosure 4- RISK ASSESSMENT

PREVENT SYSTEMS WHEN SAFETY IS TAKEN SERIOUSLY

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

G A S W A TE R /A G U A

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

Portable Fire Extinguishers

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

FoamFatale INTRODUCTION OF A NOVEL HIGH END TECHNOLOGY FOR LARGE ATMOSPHERIC STORAGE TANK FIRES. TFEX 1 Ltd.

Tel Web: dyayan.com

Mist-Tech Fire Fighting Equipment

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

Datasheet Automatic Protection System for Vehicle Engine Rooms Model: BPS

product guide 240 VOLTS NO ENTRY 240 VOLTS DANGER SAFETY SIGNS AND LABELS WE DESIGN IT - WE MAKE IT - IN AUSTRALIA

Fire Suppression Systems

PORTABLE TANKLESS GAS WATER HEATER INSTRUCTION MANUAL GA5MILITAR MODEL

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Water Mist Fire Suppression

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

CEASEFIRE WORLD SERIES

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Fire Prevention Systems

Aerosol Type Fire Extinguisher Aerosol Type Fire Extinguisher

New standard in compressed air treatment, providing Energy Savings up to 99%

FIRE SUPPRESSION SYSTEM

Fire Safety Awareness Training START

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

"FIRE PREVENTION AND SAFETY IN THE OFFICE"

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI


contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

ORDINANCE FOR TECHNICAL SPECIFICATIONS PERTAINING TO AEROSOL TYPE EXTINGUISHER APPLIANCES

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

Tel: Mecca Street Bldg 194, Amman, Jordan Mob:

Fire protection solutions for ships and offshore facilities

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

7.2 SAFETY CODE FOR BUILDING & FIRE FIGHTING SYSTEM

In the event of a halt in operations, the economic detriment to client and own business is in addition to the significant risks of consumer supply

Design and Supply of Fire Equipments. External Fire Fighting Systems.

FEEL THE COOL FEEL THE MIST

Case study: EconAqua water mist sprinkler system

UCL FIRE EXTINGUISHER SCALING & LOCATION POLICY

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

Are you warming up with space heaters?

What provides highly reliable fire protection?

1. PURPOSE 1.1- To describe fire/emergency evacuation plan for the Large Animal Research Unit (LARU).

Chapter 12 HOT WORK OPERATIONS. Purpose:

- CONSTRUCTION FIRE SAFETY STANDARDS

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

AUTOMATIC FIRE SUPPRESSION SYSTEMS

Watermist Fire Protection of Plant Rooms

National Fire Authority

MOBILE FOOD SERVICE EQUIPMENT FIELD APPROVAL SUBMISSION INFORMATION

TRAINING OCCUPATIONAL SAFETY, HEALTH PROTECTION AT WORK AND FIRE SECURITY

Inert Gas Fire Extinguishing System

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Fire fighting Questions

Nessie High Pressure Water Mist Components for Fire Fighting

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

Control and extinguishing by water mist

Fixed Fire Extinguishing Equipment and Systems

Employee Health Protection

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

[Fire Knock Out] [Brought to India by NexusNovus]

Transcription:

No fire is too big to beat. Ceasefire Watermist Hydrant Systems

Never underestimate a fire. With enough oxygen and other fuels, even the smallest flame can turn into a full-scale blaze, destroying everything in its path in just six minutes. The problem is, even if firefighters are rushing to your aid, external factors such as traffic and construction could prevent them from reaching you in time. time and a powerful firefighting equipment that s easily accessible on the premises. Equipment that gives you the power to take on any kind of fire, of any size. Ceasefire has just the solution. Introducing CF 2000 and CF 3000, the most advanced standalone Watermist hydrant systems in the market today. Which means that to beat a fire, you need two important things on your side: Quick response Why CF 2000 and CF 3000? CF 3000 CF 2000 Powered by revolutionary Watermist technology, CF 2000 and CF 3000 maximise the firefighting and cooling properties of water, and then increase it manifold. These advanced standalone Watermist hydrant systems are highly dependable. Being standalone firefighters, you don t need to worry about issues like malfunctioning pipelines and wear and tear on parts that affect commercially available hydrants. What s more, while other hydrants run dry and other fire extinguishers are exhausted before putting out all the flames, CF 2000 and CF 3000 continue the fight against fire. Featuring the same potent firefighting power as conventional hydrants with much more efficient usage of water, CF 3000 use just 60 litres of water where a normal hydrant would needs thousands of gallons to achieve the same results. CF 2000 on the other hand can be connected to existing water pipes, ensuring an unlimited water supply.

How Watermist works. Revolutionary technology break water down into a fine mist. This mist is then thrown at the fire with a great kinetic force, covering a large surface area. As soon as the mist comes into contact with the fire, it instantly turns into steam. Enveloping the flames, cutting down the oxygen supply and reducing the temperature to below combustion levels. Ensuring that even the largest fire succumbs to Watermist technology. In minutes. Fine mist Air Mist thrown with great kinetic force Steam Water O 2 About CF 2000 Nozzle The Watermist hose reel CF 2000 practically guarantees an unlimited water supply. It can be easily connected to an existing water pipe/hydrant and pressure line effectively making hundreds of litres of air and water readily available for fighting the flames. It also features an AFFF Foam additive option for increased extinguishing power. In other words, there is virtually no limit to its fire suppression power. AFFF Foam additive Hose Water pipe About CF 3000 CF 3000 is a self-contained, standalone firefighting device, suitable for locations with no ready supply of compressed air and water. This easy-to-use system features an in-built pressure container, water storage unit and an optional foam supply unit. In an emergency, all you need to do is pull out the long hose, activate the device and instantly, you ll be armed with CF 3000 s immense firefighting power. Nozzle Hose In-built pressure container Water storage unit

CF 2000 and CF 3000 features. The advanced standalone Watermist hydrant systems CF 2000 and CF 3000 are powered by the following features, guaranteeing your premises fire protection, 24x7. Effective use of water In the case of conventional water hydrants, just 5% of water directed at the fire actually helps put out the fire effectively. But in the case of CF 2000 and CF 3000, 100% water is converted into mist, which thanks to a vast evaporation surface, evaporates in the fire environment. Making CF 2000 and CF 3000 far more effective compared to a conventional water hydrant. Smaller droplets to fight larger fires As water extinguishes fire by reducing the temperature, the more area covered, the higher the cooling. CF 2000 and CF 3000 ensure 3 times further reach than normal Watermist hydrants that emit droplets of 100µ to 150µ by converting water into small droplets of < 40µ. Thermal barrier Thanks to large surface coverage, the mist s cross-section of water droplets create a barrier against radiation. As a result of the mist curtain, the firefighter is insulated from the heat being radiated and can approach the blazing fire fearlessly. A,B,C,D,F, Can be used on all classes of fires CF 2000 and CF 3000 work on all classes of fire as well as electrically started fires (E). Making them the perfect firefighters. Compatible with electronic equipment The extinguishing agent, water, is converted to a dry to the touch gas and does not cause thermal shock when it comes in contact with electronic equipment. As a result, CF 2000 and CF 3000 conduct no electricity (up to 35 kv) and can be safely used on electrically started fires. Which means that there s no risk of getting electrocuted, even if there is a leakage of electrical current around the fire on which the mist is sprayed. Independent of power supply As the system uses water stored in an inbuilt tank, in case of CF 3000, or from a water main, in the case of CF 2000, and the pressure for the throw/dispensing mechanism and mist creation is facilitated by the pressurised nitrogen gas, the system needs no power supply for pressurising the water or for manufacturing compressed air. Foam Facility of using the same system for Mist Mist as well as for Foam CF 2000 and CF 3000 s preconfigured settings let you switch from Watermist to AFFF foam and vice versa at a switch of a button. Safe on people The mist from CF 2000 and CF 3000 is made of water or inorganic salt solutions and does not harm people or the environment in the way that fire extinguishers using chemically active substances would. Safe on buildings As there s no thermal shock damage, there s no risk of cracks to structural elements, steel casings and power line ceramics. Safe on property In case of conventional fire solutions, about 80% damage is not directly caused by the flames, but by flooding with water or contamination by foam or active chemical extinguishing powder. In case of CF 2000 and CF 3000, the water evaporates on contact with the fire, ensuring minimal collateral damage. Easy on the environment The mist generated by these firefighting systems is 100% non-toxic and eco-friendly.

Applications CF 2000 and CF 3000 can be used for all kinds of applications. Not only do these advanced standalone Watermist hydrant systems provide critical backup in areas where there is a multiple fire risk, they are Power Plants and Thermal Power Stations Restaurants, Kitchens, Food Packaging Units Factories Warehouses Assembly Lines Varnishing Plants, Offices, Hospitals and other large Commercial Spaces Printing Industry Packaging industry Corrugated Boxes Manufacturing Units Garments Manufacturers a necessity in premises that are far away from Fire Stations and at plants/factories that are prone to fires that can quickly reach critical/blaze stage. CF 2000 and CF 3000 are suitable for: Footwear Industry Furniture Industry Paper Industry Malls Theatres Hotels and Restaurants Studios Movie Sets Departmental Stores Farm Houses and many more premises CF 2000 gives you more. Unlimited water supply CF 2000 sources water from a water main, allowing for continuous operation. That s hundreds of readily available litres of water, so that you can be sure your firefighter doesn t go out before the fire does. One-time installation cost Comprising components such as overhead water tanks, pipelines, and fittings, etc, once installed the system is easy to maintain and does not require re-installation. Designated location for easy accessibility Being a permanent fixture, the location of the Hydrant system would be known to all personnel and staff as well as prominently marked and can be accessed quickly during an emergency.

CF 3000 gives you more. The CF 3000 has its very own pressure and water supply. Which means that it never lets you down. Low maintenance In conventional hydrant systems, components such as the overhead water tank, pipelines, jockey pump, etc, require regular maintenance. Since CF 3000 uses water and gas stored in inbuilt tanks, it has virtually no maintenance requirement. Can be shifted In a conventional hydrant system, the installation involves a permanent investment in piping, water tank, etc, which cannot be shifted from one building to another. CF 3000 s portability is advantageous to businesses that run from rented premises, as it can be easily shifted to another premise. No installation cost Comprising numerous components such as overhead water tanks, pipelines, electrical wiring and fittings, etc, the installation costs of conventional hydrant systems tend to be very high. As CF 3000 is a standalone unit and needs no installation or fittings to become operational, there are a minimum to no installation costs. Flexible location Most conventional hydrant systems are designed to be installed near staircases. But in case of CF 3000, the installation point or the location is as per the choice and convenience of the user, giving the customer the option to place the hydrant closer to high-risk areas. Technical Features: CF 2000: Overall Dimensions: 850 x 370 x 1450 mm Total Weight of Cabinet and Device: 85 kg Length of Fire Hose: 20 or (optionally) 30 m Media Connectors: rigid connectors, type G 3/4 Water Quality: particulate matter below 200 µm Water Pressure Required: 0.40 Mpa Water Usage: 14 dm³/min Air Usage: 4 m³/min Gas Pressure Regulator: (optional) Compressed Air/Gas Pressure Required: 0.60 Mpa CF 3000: Overall Dimensions: 1200 x 370 x 1800 mm Total Weight of Cabinet and Device: 300 kg Length of Fire Hose: 20 or (optionally) 30 m Nitrogen Gas Cylinder Capacity: 70 l Nitrogen Gas Pressure: 300 bar Water Tank Capacity: 60 l Continuous Operating Time: 4 min

FIRE SOLUTIONS SECURITY FIRE ALARM SYSTEMS HOME SAFETY CEASEFIRE INDUSTRIES PVT.LTD. Plot No. - 4, Sector - 135, Noida - Greater Noida Expressway, Noida - 201301, Uttar Pradesh (India). Tel.: +91-120-7154114 Fax: +91-120-7154115 Web: www.ceasefire.in Mail: response@ceasefire.in