Electric Unit Heaters for Standard and Hazardous (Classified) Locations

Similar documents
Electric Unit Heaters for Standard and Hazardous (Classified) Locations

ELECTRIC UNIT HEATERS FOR STANDARD AND HAZARDOUS (CLASSIFIED) LOCATIONS

Brasch Hazardous Location Unit Heaters

FX5 Series Explosion-Proof Electric Air Heaters

FE1 Explosion-Proof Electric Air Heaters

Gas-Fired Unit Heaters Commercial & Industrial

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater

KUH. Horizontal Unit Heater. Applications. Description

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Description. Construction

Cabinet Unit Heaters Steam / Hot Water

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

STEAM/HOT WATER UNIT HEATERS

Refer to page 9 for information regarding the Breeze TM AccuSpec Sizing and Selection Program

Comfort. Description. Applications

EXH Series Explosionproof Electric Air Heaters

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

Description. Applications

Convectors Steam / Hot Water November, 2009

Description. Applications

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

SUBMITTAL SCHEDULE & DATA

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Rittling Unit Heaters. Catalog. Cooling

Ultra-Safe EXP Unit Heater

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

Gas-Fired Unit Heaters Commercial & Industrial

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Electric Unit Heaters

WARNING IMPORTANT. electric unit heaters H75690A

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

SECTION (15767) - UNIT HEATERS

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

UFGS (August 2008) UFGS (January 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Thermal Devices, Inc. Mount Airy, Maryland USA

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

SECTION CONVECTION HEATING AND COOLING UNITS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

CR1 Series Triton Corrosion Resistant Washdown Heaters

Industrial Air Heaters

Type UB-2502A and UB-3002A Forced-Air Heater

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air


Product Specifications. Vertical Floor Consoles By First Co.

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

SECTION CONVECTION HEATING AND COOLING UNITS

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

SECTION AIR DOORS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

ULTRA-SAFE Explosion-proof Duct Heaters

Explosion-Proof Forced Air Unit Heater - XGB

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

1.1 This section applies to air handling units for HVAC Systems.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Explosion-Proof Forced Air Unit Heater - XGB

Custom Duct Heaters. Special Applications

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

CX1 ProVector Explosion-Proof Heaters

ELECTRIC UNIT HEATER REGULAR DUTY

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

CF1 ProVector Explosion-Proof Heaters

SKYPAK II, 3 Ton Series, gives you a

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

SKYPAK II, 3 Ton Series, gives you a

bring value to your space

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS


Indirect Gas-Fired Make-Up Air

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Circulation Heaters Selection Guidelines

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

HD3D Forced-Air Heater

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Transcription:

2-116. January, 07 Electric Unit eaters for Standard and azardous (Classified) Locations MODEL ER MODEL VE MODEL PTE MODEL EX

table of contents Table of Contents Page Electric Unit eaters - Models ER, VE, PTE - Design Benefits Features... Unit Components...4 Unit Options...5 Performance/Dimensional Data Model ER - orizontal Delivery Unit eaters...6 Model VE - Vertical Delivery Unit eaters... 7-8 Model PTE - PowerThrow TM orizontal Delivery Unit eaters...9 Ordering Information...9 Model EX - Explosion Proof orizontal Delivery Unit eaters Features...10, 11 Performance Data... Dimensional Data...1 Specifications Models ER,VE,PTE...14 Model EX...15 Selectable using the Modine Breeze TM AccuSpec Selection Software. As Modine Manufacturing Company has a continuous product improvement program, it reserves the right to change design and specifications without notice. 2 2-116.

electric unit heaters - MODELS ER, VE, PTE Features Wide Range of Sizes and Types orizontal air delivery unit heater type (ER series): 27 models, seven sizes from 5 kw through 25 kw. orizontal delivery units are recommended for use in buildings where ceilings are low and with few obstructions. They are equipped with air deflector blades that can be adjusted to lengthen or shorten heat throw as well as to direct heated air either up or down. Vertical deflector blades are also available (optional) to deflect air either to the left or right of the heater. Together, both sets of deflectors permit complete directional control over discharge of heated air. orizontal delivery units are normally placed around the perimeter of the building so that the air stream from each heater wipes the wall to produce a blanket of warm air along the building s outside walls where heat loss is greatest. Vertical air delivery unit heater type (VE series): 21 models, nine sizes from 5 kw through 50 kw. Vertical delivery units are generally installed in areas where ceilings are high and where obstructions do not permit good horizontal movement of air. Deflectors (optional) can be used to produce a variety of distribution patterns (see page ). Vertical unit heaters are usually oriented so that the heat spread from one overlaps the heat spread of another unit heater. Power-Throw unit heater type (PTE series): Three models, three sizes from 15 kw through 50 kw. Where there is a requirement for air velocity and heat throw greater than can be provided by cataloged horizontal delivery models, Power-Throw unit heaters with their longer horizontal heat throw should be considered. For hard-to-heat areas, such as the vicinity of frequently opened loading dock doors or large warehouses, Power-Throw units are frequently an ideal choice. They are equipped with air deflector blades that can be adjusted to lengthen or shorten heat throw as well as to direct heated air either up or down. Due to the higher velocity of discharge air, however, their air streams should not be directed at room occupants. A single Power-Throw unit heater can often be used to replace as many as three smaller horizontal delivery units, thereby reducing equipment, installation and maintenance costs. Low Installation Cost Transformers, contactors and fuses are factory-furnished and factory-wired when required. Terminal blocks are supplied to facilitate connection of power supply and control wiring. Standard wiring and conduit sizes are utilized. Modine electric unit heaters are lightweight - require no special reinforcement to suspend them. ang them, connect them to the power supply, controls and thermostat and they are ready to operate. Easy to Service Fan and motor are exposed and can be removed without lowering the unit heater. A hinged bottom panel permits full access to controls on models ER, horizontal units. Vertical delivery and Power-Throw models have separate control boxes externally mounted on the units. Motors are totally enclosed, permanently lubricated, and thermally protected. Electrical contactors, fuses, and transformers are all safely enclosed in control compartments. Control Flexibility Low-voltage control is available for both horizontal and vertical delivery models for low voltage thermostat control. Standard two-stage controls are used on 0, 40, and 50 kw vertical and Power-Throw unit heaters. Low-voltage control is not offered for use with two-stage thermostats on the three larger capacity vertical units nor on the Power-Throw units. Application Flexibility Total eating Units can meet the total heating requirement in most industrial plants, commercial and recreational buildings, and in specialpurpose structures such as animal shelters. The features that make them the ideal selection for these types of buildings are a long heat throw, uniform heat delivery and low installation and maintenance costs. igh up and out-of-the-way, unit heaters provide heat into work areas for clean, safe, economical heating comfort. Temporary eating The ease with which electric unit heaters are installed make them ideal for use in buildings under construction, where heat is needed temporarily. Supplemental eating They are ideal for spot heating applications during short periods of occupancy in the area to be heated. In out-of-theway locations, remote from areas served by the building s main heating systems, electric unit heaters can often eliminate the expense of extending gas, steam, or hot water lines. Stand-by/Back-up eating Where fossil fuel supplies are interruptible or undependable, electric unit heaters are recommended as a stand-by or backup heating system to supply comfort to an entire building or any part of it. Quiet Operation Fans are accurately balanced to move air quietly. Die-formed venturi openings reduce noise of air movement and shield motors on vertical delivery and Power-Throw models to dampen operational noise and to keep motors cool. Motors mounted to fan guards utilize rubber vibration absorbing material for quieter operation. Longer Unit eater Life Nickel chromium wire elements are enclosed in a powderfilled steel tube around which external fins are spiralled and permanently fused to provide maximum heat transfer. eating elements are resistant to thermal shock and vibration for a long, trouble-free life. 2-116.

DESIGN BENEFITS Unit Components Figure 4.1 - Model ER Controls and Features Safety fan guard Formed from heavy steel rod stock, the fan guard eliminates the hazards presented by an exposed fan. The guard is attached to the unit heater casing and provides a rigid support for the motor. Motor The totally enclosed, thermally protected, continuous-duty motor is mounted to the heavy steel fan guard utilizing rubber vibration absorbing material. Motors are selected to match fan requirements. Automatic re-setting overheat control In the event the unit heater becomes overheated, this interrupts the power supply to the heating elements. The control automatically resets itself once the unit has cooled to a safe temperature. Fan The large-bladed, lightweight aluminum fan is connected directly to the motor shaft and is statically balanced for peak performance. Adjustable air deflector blades Adjustable up and down, blades provide control over the horizontal air delivery of the unit heater. Casing The steel casing is rustand corrosion-treated prior to application of a baked-on, gray-green enamel finish. inged bottom panel swings down for full access to wiring and control compartment. eating Element Nickel-chromium wire elements are enclosed in powder-filled aluminum coated steel tubes to which fins are permanently fused for maximum heat transfer. Controls Terminal blocks and contactors are built into all units. Transformers and fuse blocks with fuses, when required, are factorymounted and wired. c Figure 4.2 - Drop Down Service Panel Drop the bottom hinged panel and all controls and electrical connections become completely accessible. A wiring diagram is attached to the panel for easy reference during installation and servicing. Figure 4. - Model VE Controls and Features Control Compartment Safely encloses power and control terminal blocks, contactor(s), fuses and transformer. Terminal block Provides easy access to heating element terminals and overhead control switch. Automatic resetting overheat control In the event of overheating, this control interrupts the power supply to the heating elements. The control automatically resets itself once the heater cools to a safe temperature. Control includes a switch located in terminal box and a capillary tube around bottom heating element. Motor heat shield Motor is protected from heated air passing through the unit heater by this heat shield. c eating element Nickel-chromium wire elements are enclosed in powder-filled aluminum coated steel tubes to which fins are permanently fused for maximum heat transfer. Protective screen This noncorrosive aluminum screen protects heating elements from accidental damage and further enhances the appearance of the unit heater. Motor Totally enclosed and thermal overload-protected. Motor is continuous-duty, selected to match fan requirements, and is attached to motor mount with rubber vibrationabsorbing material. Fan Large, lightweight statically balanced aluminum fan directly connects to motor shaft. Safety fan guard Formed from heavy steel rod stock, the fan guard eliminates the hazards presented by an exposed fan. 4 2-116.

DESIGN BENEFITS Unit Options Thermostats The unit-mounted thermostat in Figure 5.1 is provided as a field installed kit for a horizontal delivery unit heater (ER series only). Temperature range of the dial setting is from 40 F to 90 F. Other thermostats offered (not unit-mounted) are: Line-voltage single stage thermostat (various ratings) Line-voltage, 2-stage thermostat (available on vertical delivery and Power-Throw models 00, 400 and 500) Low-voltage single stage thermostat (various ratings, requires Low-Voltage Control kit.) Low-Voltage Control This control permits use of a low-voltage thermostat temperature control of electric unit heaters. igh capacity models VE00, VE400, VE500 and all PTE series heaters cannot operate in two stages with a low-voltage thermostat; however, they will respond in one stage with full operation of all elements. On horizontal models (ER series), this control cannot be combined with the unit-mounted thermostat. Summer-Winter Switch To allow a choice of fan operation, a summer-winter toggle switch kit is available for field installation. In the winter position, the thermostat will cycle the fan and heating elements on and off. In the summer position, the switch will permit the fan to run continuously while the heating elements are controlled by the thermostat. Maximum switch rating is 10 amperes at 250 volts. Kit includes toggle switch, conduit box, wire nuts, and installation instructions. Vertical Unit Air Deflector Blades Blades used to deflect airflow in directions left or right of unit heater. Used in addition to standard horizontal deflector blades. Not available for Power Throw TM models. Vertical Unit Air Deflectors The cone-jet allows the discharge air stream to be adjusted from a concentrated high velocity jet to a broadened air stream to cover a larger area. See page 8 for additional information. The truncone causes a broad discharge air stream covering a larger area than possible with the cone-jet. See page 8 for additional information. The one-way louver allows the discharge air stream to be adjusted in one direction. See page 8 for additional information. The two-way louver allows the discharge air stream to be adjusted in two directions. See page 8 for additional information. Figure 5.1 - Unit-Mounted Thermostat Figure 5.2 Low-Voltage Control Pipe Suspension Adapter Kit Figure 5. Summer-Winter Switch To facilitate threaded-pipe suspension mounting, a pipe-adapter kit is available that includes two drilled pipe caps and two /8-16 x 1 1/2" capscrews. One kit is required to pipe-mount a horizontal unit (ER series) and two kits must be ordered to mount vertical (VE series) unit heaters. (On vertical models VE50 through VE250 supplied with volt, phase service, clearance is not adequate for utilization of this kit.) This kit cannot be used with Power-Throw (PTE series) unit heaters. Wall Mounting Bracket For easier unit installation, where ceiling suspension is not feasible, a wall-mounting bracket is available for horizontaldelivery models ER50 through ER250 and PTE00 through PTE500. The one-point suspension illustrated in figure 5.4 permits swiveling the unit 90 horizontally for most effective air flow direction. Fasteners for mounting to wall are not furnished. Figure 5.4 - Wall Mounting Bracket 2-116. 5

horizontal delivery unit heaters - MODEL ER Dimensional Data Table 6.1 - Outline Dimensions in Inches Electrical Unit eater Models Dim. ER50 ER75 ER100 ER5 ER150 ER0 ER250 A 16-7/8 16-7/8 16-7/8 16-7/8 16-7/8 18-7/8 18-7/8 B -7/8-7/8-7/8-7/8-7/8 24 24 C 14-/4 14-/4 14-/4 14-/4 14-/4 D 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 16-1/2 16-1/2 E 1 1 1 1 1 16 16 F 8-7/8 8-7/8 9-5/8 9-5/8 9-5/8-5/8-5/8 G 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 15-1/2 15-1/2-1/4-1/4 21-1/4 21-1/4 21-1/4 26-1/2 26-1/2 K 2-1/4 2-1/4 2-1/4 2-1/4 2-1/4-1/4-1/4 L -1/4-1/4-1/4-1/4-1/4 4-1/4 4-1/4 M 2-1/4 2-1/4 2-1/4 2-1/4 2-1/4 2-1/2 2-1/2 O -/4 -/4 -/4 -/4 -/4 14-1/2 14-1/2 Fan Dia. 14 14 Wt. 1 Lbs. 52 52 67 65 74 97 98 Figure 6.1 - Dimensions of Unit eaters ➀ Approx. Shipping Weight Add 7 lbs. for Volt Models. Table 6.2 - Motor Specifications Motor Bearing Model P Amp. Voltage RPM Type Type ER50 1/40 0.50 8-/60z/1ph 1550 ER75 ER100 thru 1/15 1.28 8-/60z/1ph 1050 ER250 Totally Enclosed, Shaded Pole with Thermal Overload Sleeve c Table 6. Performance Ratings of orizontal Unit eaters eating Capacity fan and Air Delivery Data Max. Electrical Data Outlet Temp1 eat➁ Mtg. Model Inlet Velocity Rise Throw t.➁ Power Supply Total No. kw Btu/r CFM (FPM) (F) (FT.) (FT.) Code Volts Phase Amps 11 8 1 24.5 240 1 21. ER 50 5 17,100 50 4 0 14 8 1 8 14. 2 240.5 6.5 11 8 1 6.5 240 1 1.7 ER 75 7.5 25.600 50 40 45 14 8 1 8 21. 2 240 18.5 9.5 11 8 1 49.4 240 1 42.9 ER 100 10 4,100 80 670 8 9 1 8 29.0 2 240 25. 1. 1 8 6.0 ER 5.5 42,700 80 680 48 10 2 240 1.4 16. 1 8 42.9 ER 150 15 51,0 80 690 57 10 2 240 7.4 19. 1 8 56.8 ER 0 68,00 100 760 49 25 11 2 240 49.4 25. 1 8 70.7 ER 250 25 85,400 100 780 61 25 2 240 61.4 1.4 1 With 70 F Ambient Air ➁ eat throw with 70 F ambient and louvers directed to the floor at 45. Mounting the unit higher or lower that these mounting heaights will increase or decrease the heat throw. 6 2-116.

vertical delivery unit heaters - MODEL VE Dimensional Data Table 7.1 Dimensions in Inches Model No. Dim. VE50 VE75 VE100 VE150 VE0 VE250 VE00 VE400 VE500 A➀ 18 18 18 18 18 18 18 18 18 B 11 /8 11 /8 11 /8 11 /8 11 /8 11 /8 18 /8 18 /8 18 /8 C 14 1/2 14 1/2 14 1/2 14 1/2 14 1/2 14 1/2 19 1/2 19 1/2 19 1/2 D 24 7/8 24 7/8 24 7/8 24 7/8 24 7/8 24 7/8 4 7/8 4 7/8 4 7/8 E 4 1/4 4 1/4 5 5 5 5 8 5/8 8 5/8 8 5/8 F 4 /4 4 /4 4 /4 4 /4 4 /4 4 /4 2 1/8 2 1/8 2 1/8 G 4 /4 4 /4 4 /4 4 /4 4 /4 4 /4 4 /4 4 /4 4 /4 6 1/4 6 1/4 6 1/4 6 1/4 6 1/4 6 1/4 6 1/4 6 1/4 6 1/4 Fan Dia. 14 14 14 14 14 14 19 19 19 Approx. Wt. Lbs. 62 64 66 70 72 7 2 5 9 ➀ Minimum Table 7.2 Motor Specifications Model Motor Type Bearing No. P Amp. Voltage RPM W/T.O.L. Type VE50-VE100 1/15 1.28 8-/60z/1ph 1050 Totally Enc. Sleeve Shaded Pole VE150-VE-250 1/8 1.00 8-/60z/1ph 1725 Totally Enc. Ball PSC VE00-VE500 1/6 1.54 8-/60z/1ph 1075 Totally Enc. Ball PSC c Figure 7.1 Unit eater Dimensions VE 50 VE 75 A VE100 VE150 MINIMUM CLEARANCES: AT LEAST 18" FROM CEILING AND 24" ORIZONTALLY FROM NEAREST ENCLOSURE. C CEILING SIDE VIEW G E F (4) MTG OLES 1/2 1 N.C. TAP B TOP VIEW D DIAMETER KNOCKOUTS FOR POWER SUPPLY AND CONTROL WIRES. MODELS VE50 TROUG VE250 SOWN Table 7. Performance Ratings of Vertical Unit eaters Model No. eating Data kw (Btu/r) 5.0 (17,100) 7.5 (25,600) 10 (4,100) 15 (51,0) Outlet cfm 800 800 940 140 Air Data➀ Discharge Velocity FPM 700 700 8 1170 Temp. Rise ( F) 21 1 6 8 Power Code 1 2 1 2 1 2 1 2 Electrical Data Supply Volts 240 8 240 240 8 240 240 8 240 8 240 Phase 1 1 1 B Total Amps. 21.4 14.5.7 6.7 1.9 21.4 18.6 9.7 42. 28. 24.6.7 42.5 7.0 19.0 VE0 19 (64,900) 1600 1400 41 2 240 49 25 VE250 25 (85,400) 1600 1400 55 1.0 igh: 15 1-stage (51,0) VE00 Low:0 2-stage (102,222) 2575 40 40 19.5 7.6 igh: 1-stage (68,00) VE 400 Low:40 2-stage (17,000) 2575 40 54 25.5 49.6 igh: 25 1-stage (85,400) VE500 Low: 50 2-stage 171,000) 2575 40 70 1.5 61.5 ➀ With 70 F ambient air and heating at full capacity 2-116. 7

vertical delivery unit heaters - MODEL VE Performance Data Table 8.1 Vertical Air Outlet Accessories Model Truncone Cone-Jet Louvers No. M X L T P Z VE50-VE250 1/2 22 6 1/2 18 7/8 6 1/2 16 7/8 VE00-VE-500 1/2 27 7 1/2 24 /4 7 1/2 19 /4 Figure 8.2 Without Deflector Figure 8.1 - Unit with Truncone CONE-JET TRUNCONE T L X M Figure 8. With Truncone s LOUVER P Z s Table 8.2 eat Spread and Mounting eight (Ft.) ➁ Figure 8.4 With Cone-Jet With No Deflector Truncone With Deflector Cone-Jet Louvers Model No. VE 50 VE 75 VE100 VE150 VE0 VE250 VE00 VE400 VE500 ➁ ➂ Vertical➂ Max. Spread eight (S) S S 1 11 17 17 18 16 17 18 26 0 26 1 27 24 9 8 8 11 1 11 15 1 24 22 0 6 1 6 2 29 18 15 17 2 27 2 28 24 22 2 22 0 5 1 6 2 29 With 70 F ambient air and heating at full capacity eat Spread and Mounting eight Vertical➂ S 1 11 17 18 21 18 16 45 ➂ Refer to Table 8.2 for the recommended mounting heights and accompanying heat spread of vertical units without an air deflector and with the three air deflectors offered. 15 1 14 2 24 21 19 8 8 8 10 10 11 10 S 2 22 0 5 1 6 2 29 Indicates pitch of adjustable louvers. 45 louvers are available for one- or twoway deflection Figure 8.5 With Louvers Vertical S One-Way Deflection Two-Way Deflection s s s 8 2-116.

Power-Throw horiz. delivery unit heaters - MODEL PTE Dimensional Data Table 9.1 Motor Specifications Motor Type Bearing Model P Voltage RPM w/tol Type PTE00 thru 500 1/6 8-/60z/1ph 1075 Totally Enc. PSC Ball Note: Shipping weight of each of these models is 1 lbs. Figure 9.1 Dimensions of Unit eaters Table 9.2 Performance Ratings of Power-Throw Unit eaters 1-stage PTE 400 2-stage 1-stage PTE 500 2-stage eating Data kw Outlet cfm Model (Btu/r) FPM➁ 1-stage 15 2575 PTE (51,0) 00 0 2-stage 40 (102,000) (68,00) 40 (17,000) 25 (85,400) 50 2575 40 2575 40 (171,000) Temp. Rise ( F) 40 54 70 Air Data➀ Mounting eat eight ➀ Throw (Ft.) T➀ (Ft.) ➀ With 70 F ambient air and heating at full capacity. ➁ Discharge Velocity FPM Figure 9.2 17 15 14 75 60 45 Power Code Electrical Data Supply Volts Total Phase Amps. 19.5 7.6 25.5 49.6 1.5 61.5 T Ordering Information To order a Modine electric unit heater, specify: 1. MODEL NUMBER: Select model number from Table 9. and indicate unit heater type, i.e., horizontal (ER), vertical (VE) or Power-Throw (PTE) Table 9. Kilowatt Rating 5.0 7.5 10.0.5 15.0.0 25.0 0.0** 40.0** 50.0** orizontal Unit eater Model No. ER50 ER75 ER100 ER5 ER150 ER0 ER250 Vertical Unit eater Model No. VE50 VE75 VE100 VE150 VE0* VE250 VE00 VE400 VE500 Power-Throw Unit eater Model No. PTE00 PTE400 PTE500 * VE0 19.0 kw/64,900 Btu/r ** On igh Stage Btu/r 17,100 25,600 4,100 42,700 51,0 68,00 85,400 102,000 17,000 171,000 2. POWER CODE: Select power code from Table 9.4 to agree with power supply to be used to operate unit heaters. Table 9.4 Power Supply (Volts/Phase) 8/1φ 240/1φ 8/φ 240/φ /φ Power Code 11 1 2. CONTROL CODE: Use control code 01 for electric unit heaters. EXAMPLES On a horizontal delivery unit heater order: Model ER 100//01 refers to a horizontal electric unit heater with a 10- kilowatt rating for a 240 volt, single-phase power supply. The unit heater has factory-installed standard components. On a vertical delivery unit heater order: Model VE500//01 refers to a vertical electric unit heater with a 50 kilowatt rating for a volt, phase power supply. The unit heater has factory-installed standard components. 2-116. 9

explosion-proof horizontal unit heaters - MODEL EX Features WARNING Before installing and operating heaters confirm location, classification and properties of flammable vapors, liquids, gases, dusts and fibers which may be present. Each room, section or area should be considered individually. For further information consult National Electric Code and National Fire Prevention Association (ANSI) standards. Designed for hazardous locations. 26 models from through 5 kw. Explosion-Proof orizontal Delivery Unit eaters These heaters are designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of flammable gases, vapors, powdered metals or dusts. eaters are UL Listed for Class I, Divisions 1 & 2, Groups C and D; Class II, Division 1, Groups E, F and G, and Class II, Division 2, Groups F and G. UL temperature code shall be TB 29 F (165 C) for Class I and II, indicating maximum operating surface temperatures. Figure 10.1 Controls and Features Abbreviated descriptions of UL classes, groups and divisions. Before selecting any heater for a particular application, refer to Article 500 as well as other standards referenced in the National Electric Code. Class I: Locations in which flammable gas or vapors may be present. Class II: Locations in which combustible dusts may be present. Group C: Atmospheres such as, but not limited to, Ethylene, Alcohol, Carbon Monoxide, or ydrogen Sulfide. Group D: Atmospheres such as, but not limited to, acetone, gasoline, natural gas, propane or other gases or vapors of equivalent hazard. Group E: Atmospheres containing combustible metal dust regardless of resistivity, or other combustible dust of similar hazard characteristics. Group F: Atmospheres containing carbon black, charcoal, coal or coke dust or dust of similar hazard characteristics. Group G: Atmospheres containing flour, starch, grain dust or dusts of similar hazards. Division I: A location in which ignitable concentrations of flammable material exist under normal operating conditions. Division II: Locations in which flammable materials will normally be confined within closed containers and escape only in the case of accidental rupture, breakdown or during maintenance operations. Any equipment approved for Division I is automatically also approved for Division II. Built-In Load Carrying Contactor with Severe Duty Coil 100 PSIG (690 kpa) pressure relief valve Integral Aluminum Finned Steel eat Exchanger Tubes Direction Control of Airflow Printed Circuit Board NEMA Type 7 & 9 Enclosures Teflon Liner Keeps Elements Away from Outer Surfaces Built-In Control Transformer Liquid Filled Lower Tank Convenient Terminals for Room Thermostat Connection Metal Sheathed Immersion Type eating Elements - Low Watt Density Built-In Fuse Protects Contactor Coil Spare Fuse Located in Convenient older Tin Plated Copper Bus Bars Threaded Explosion-Proof Covers Automatic Reset Bimetal igh-limit Core Easily Removable Through Bottom of eater Cabinet Teflon is a registered trademark of E.I du Pont de Nemours & Co. 10 2-116.

explosion-proof horizontal unit heaters MODEL EX Features Figure 11.1 Evacuated liquid to air heat exchanger with low watt density heating elements in ethylene glycol solution that provides freeze protection to -49 F (-45 C). Figure 11.2 EX 4 unit heaters are U.L. approved for Class I, Division 1 & 2, Groups C & D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F & G azardous Locations. They are designed for rugged industrial applications such as oil refineries, petrochemical plants, pulp and paper mills, coal mines, grain elevators, etc. where specific explosive gases or dusts are present. Liquid to air, finned tube heat exchanger core. Ethylene Glycol and water mixture used as heat transfer fluid in the heater core, providing -49 F (-45 C) freeze damage protection. Thermally protected, automatic reset explosion-proof motor driven fan moves air across finned tubes for even heat distribution. Automatic reset, bimetal, high-limit provides over temperature protection and is rated for 100,000 cycles of service. Pressure relief valve handles over-pressure. Epoxy coated 14 gauge steel cabinet contains heater core, motor and fan assembly. Narrow gap two-piece safety fan guard shields all moving parts. Adjustable extruded aluminum louvers allow directional control of air. All fasteners are plated for corrosion protection. Copper conductor wires enclosed in steel conduits carry all electrical power. Before selecting any heater for a particular application, refer to Article 500 as well as other standards referenced in the National Electric Code. Figure 11. 1 Volt Control Epoxy Coated 14 Ga. Steel Cabinet Aerodynamic Extruded Aluminum Louvers Narrow Gap Split Fan Guard eavy Gauge Embossed Fan Blades Easy access to controls in explosion-proof enclosure with screw-on cover makes for easy access for installation and maintenance. Factory Wired Motor Connections Large, eavy-duty Aluminum Data Plate for Easy Legibility Optional Built-In Thermostat Protective Cover Prevents Burns Thermally Protected Automatic Reset Explosion-Proof Motor Reverse Threaded Conduit for Easy Motor Removal 2-116. 11

EXPLOSION-PROOF ORIZONTAL UNIT EATERS - MODEL EX Performance Data Table.1 - Performance Data Max. Total Temp Max orizontal nominal Altitude Voltage Current, Rise, Airflow @ Mounting eat Model kw A.S.L. (ft) (60z) Amps (1) Btu/r F 70 F, CFM eight, ft. Throw, ft. EX4-8160- EX4-240160- EX4-860- EX4-24060-,000 8V/1ph 240V/1ph 8V/ph 240V/ph 14.4.5 8. 7.2 10,250 19 EX4-60- V/ph.6 EX4-8160-5 8V/1ph 24 500 7 15 EX4-240160-5 EX4-860-5 EX4-24060-5 EX4-60-5 EX4-8160-7.5 EX4-240160-7.5 EX4-860-7.5 EX4-24060-7.5 5 7.5 8,000 10,000 240V/1ph 8V/ph 240V/ph V/ph 8V/1ph 240V/1ph 8V/ph 240V/ph.8 1.9 6 6.1 1..8 18 17,050 25,600 1.6 27.9 EX4-60-7.5 V/ph 9 EX4-240160-10 240V/1ph 41.7 850 10 0 EX4-860-10 EX4-24060-10 EX4-60-10 EX416-860-15 10 7,000 8V/ph 240V/ph V/ph 8V/ph 27.8 24.1 41.6 4,100 7.2 EX416-24060-15 240V/ph 6.1 15 10,000 51,0 27.1 EX416-60-15 V/ph 18 1750 10 40 EX416-60- 7,000 V/ph 24.1 68,250 6.1 EX4-60-25 25 10,000 V/ph 0.1 85,00 21.9 600 EX4-60-0 0 7,000 V/ph 6.1 102,50 26. 70 EX4-60-5 5 6,000 V/ph 42.1 119,450 28 950 Model Coding EX4 60 25.0 KILOWATT RATING ERTZ PASE VOLTAGE FAN SIZE (INCES) MODEL SERIES Installation Conditions 1. The EX4 VacuCore Series Electric Air eaters are listed by U.L. for maximum surface temperatures. Use only in atmospheres having an ignition temperature higher than 29 F (165 C) (TB) for class I & II. 2. Altitude restrictions apply see Specifications.. eaters must be installed in a permanently mounted upright position and be connected to a fixed power supply. 4. Read and be aware of the terms of our Warranty. 5. Refer to Owner s Manual. 2-116.

explosion-proof horizontal unit heaters - MODEL EX Dimensions Figure 1.1 - Physical Dimensions (TO FIELD WIRING OPENING) (FOR REMOTE ROOM TERMOSTAT OPENING) Table 1.1 - Operating and Shipping Weight (lbs.) Model Operating Shipping Size Weight Weight EX4 111 151 EX416 1 17 EX4 154 4 Table 1.2 - Motor/Fan Specifications fan Model Motor Bearing Diameter, Size P Type Type in. EX4 EX416 EX4 1/4 1/2 Totally Enclosed, Explosion Proof Ball 16 Accessories TEX-1 azardous Location Thermostat As an option, this thermostat is available factory installed and unit mounted. (copper free) (Temperature range 6 to 82 F/2-28 C). 22 amps resistive, 1/2 p@5 VAC, 1 p@250 VAC WMK Wall Mounting Kit Ideal for use in buildings that have substantial walls. the Z sections provide additional support where necessary. MK anging Mounting Kit Simple and economical if adequate overhead structure exists. Requires 1/2" pipe, cut and threaded (not supplied) BMK Basic Mounting Kit The BMK is suitable for applications where the support arm can be bolted or welded directly to structural steel or concrete. 2-116. 1

specifications - MODELS ER, VE, PTE orizontal Delivery Unit eaters General The contractor shall furnish and install MODINE horizontal air delivery electric unit heaters of the size, capacity, and voltage specified on the plans and/or specifications. eaters shall be installed according to manufacturer s recommendations and applicable local and national codes, and shall be UL and C-UL listed. Unit Casing Unit shall have a steel casing. Casing shall be treated to prevent corrosion and painted with a corrosion resistant, polyester powder coat gray-green finish. Top of casing shall have two threaded holes (/8" - 16 TAP) for threaded rod suspension. Bottom of casing shall have a hinged panel for service access to wiring and controls. eating Elements Elements shall consist of a nickelchromium resistance wire surrounded with magnesium oxide and sheathed in steel spiral-finned tubes. Elements shall have kilowatt rating as specified. Motor and Propeller Fan Each unit shall have a single 8/ volt motor and propeller. The motor shall be totally enclosed, continuous-duty, with automatic resetting, thermaloverload protection. Propeller fan shall be directly connected to the motor shaft and be statically balanced. Motor mounted to unit with rubber vibration absorbing material. Electrical All units shall have built-in contactors and control circuit transformers (where required) to provide single-source power connection. Built-in fuse blocks and factory-supplied fuses shall be installed on all models except ER 50 and ER 75 with 8 volt or volt single- or -phase power supply. A wiring diagram and grounding lug shall be included in each control compartment. Air Deflectors Removable and adjustable horizontal air deflectors shall be furnished on all models. Vertical Delivery Unit eaters General The contractor shall furnish and install MODINE vertical air delivery electric unit heaters of the size, capacity, and voltage specified on the plans and/or specifications. eaters shall be installed to manufacturer s recommendations and applicable local and national codes, and shall be UL and C-UL listed. Unit Casing Casings shall consist of two circular steel covers that are bolted together with the heating element supports. The bottom cover shall have a die-formed fan venturi. The top cover shall include an inner cone for motor mounting to provide a heat shield form radiant and convected air from the heating elements. Casing shall be treated to prevent corrosion and painted with a corrosion resistant, polyester powder coat gray-green finish. eating Elements Elements shall consist of nickel-chromium resistance wire surrounded with magnesium oxide and sheathed in steel spiral-finned tubes. Elements shall have kilowatt rating as specified. Motor and Propeller Fan Each unit shall have a single 8/ volt motor and propeller. The motor shall be totally enclosed, continuous-duty, with automatic resetting, thermaloverload protection. Propeller fan shall be directly connected to the motor shaft and be statically balanced. Motor mounted to unit with rubber vibration absorbing material. Electrical All units shall have built-in contactors and control circuit transformers (where required) to provide a single-source power connection. Models VE00, VE400 and VE500 shall have two sets of contactors to provide two-stage heating operation with a two-stage thermostat. Built-in transformers and build-in fuse blocks with factory-supplied fuses shall be installed on all models with volt, -phase power supply to permit volt motor operation. Electrical control components shall be safely enclosed in a separate junction box. A wiring diagram and a grounding lug shall be included in each power junction box. Power-Throw (orizontal Delivery) Unit eaters General The contractor shall furnish and install MODINE Power-Throw (Model PTE); horizontal air delivery electric unit heaters of the size, capacity, and voltage specified on the plans and/or specifications. eaters shall be installed according to manufacturer s recommendations and applicable local and national codes, and shall be UL and C-UL listed. Unit Casing Each unit shall consist of two circular steel covers securely bolted together with the heating element supports to form a single unit. Air discharge side cover shall have a dieformed fan venturi. Back cover shall have a depression for motor mounting with openings for cooling-air circulation for the motor. Four hanging brackets shall be provided for 5/8-inch diameter suspension rods to be furnished by installer. Casing shall be treated to prevent corrosion and painted with a corrosion resistant, polyester powder coat gray-green finish. eating Elements Elements shall consist of a nickelchromium resistance wire surrounded with magnesium oxide and sheathed in a steel spiral-finned tube. Elements shall have kilowatt rating as specified. Motor and Propeller Fan Each unit shall have a single 8/-volt motor and propeller. The motor shall be totally enclosed, continuous-duty, with automatic resetting, thermaloverload protection. Propeller fan shall be directly connected to the motor shaft and be statically balanced. Motor mounted to unit with rubber vibration absorbing material. Electrical All units shall have built-in contactors and control circuit transformers (where required) to provide a single-source power connection. Models PTE00, PTE400, and PTE500 shall have two sets of contactors to provide two-stage thermostat. Built-in transformers and built-in fuse blocks with factorysupplied fuses shall be installed on all models with volt, phase power supply to permit volt motor operation. Electrical control components shall be safely enclosed in a separate junction box. A wiring diagram and a grounding lug shall be included in each power junction box. Air Deflectors An adjustable horizontal air deflector assembly shall be furnished on all models. 14 2-116.

Specifications - Model EX 1.0 General 1.1 The explosion-proof unit heater(s) shall be supplied and installed in accordance with the plans and specifications, with ratings as listed in the schedule of electrical heating equipment, and shall be MODINE EX4 Series Explosion-Proof Electric Air eaters. 1.2 The unit heater(s) shall be 60 ertz models and be Underwriters Laboratories Inc. listed for use in Class I, Divisions 1 & 2, Groups C & D; Class II, Division 1, Groups E, F & G; Class II, Division 2, Groups F & G; and Class I, Zones 1 & 2, Groups IIA & IIB azardous Locations, and shall be rated for National Electrical Code Temperature Code TB, 165 C (29 F). 1. The unit heater(s) shall be manufactured under a registered ISO 9002 quality system. 1.4 Temperature limitationsd are: Operational: -49 F to 104 F (-45 C to 40 C). Storage: -49 F to 176 F (-45 C to 80 C), short term to 248 F (1 C). 2.0 eater Exchanger 2.1 The heat exchanger shall be fluid-to-air type consisting of steel tubes with roll-formed aluminum fins and be vacuum charged. 2.2 The heat exchanger shall be protected by a preset 100 psig(690 kpa) pressure-relief valve, aluminum body, no serviceable parts. 2. The heat exchanger shall be filled to design level with a custom-blended, long-life solution of ethylene-glycol, water, and corrosion inhibitors for freeze pretection to -49 F (-45 C). 2.4 The heat exchanger shall have three heavy-duty immersion heating elements brazed into a heavy steel bulkhead. The elements shall consist of high-quality resistance wire embedded in a compacted magnesium oxide refractory and sheathed in a metal tubing. The heater is to be protected by a snap-action bimetal temperature high-limit cutout rated 100,000 cycles at 10 amps. The high-limit shall not be effected by altitude or changes in atmospheric pressure. The high-limit shall be an automatic reset type, and will shut off the heater if the exchanger temperature rises due to a lack of heat dissipation..0 Fan and Motor assembly.1 The fan assembly shall include a ball bearing, permanently lubricated, thermally protected explosion-proof motor rated for continuous duty, 1725RPM..2 The fan blades shall be aluminum to prevent sparking. The fan shall be directly connected to the motor, balanced, and designed specifically for heater application.. The fan shall be shielded with a heavy-duty epoxy coated guard. To provide easy maintenance and cleaning of the fan and motor, the fan guard shall be of a two-piece construction. The guard shall not allow a 1/4 or larger probe to enter. and tested, and enclosed in an explosion-proof control enclosure with a large threaded cover for easy access. 4.2 The control center shall include a magnetic contactor sized to handle the heater and motor current. The contactor shall be rated for 500,000 mechanical operations. The coil shall be 1V encapsulated severe duty and separately fuse-protected. 4. The control center shall include a control circuit transformer, the primary voltage being the same as the heater voltage and the secondary being a 1V grounded circuit. 4.4 The control center shall include printed circuit board with a terminal block for room thermostat connection. 4.5 The control circuit shall include in-line fuse protection on secondary side of transformer. The fuse holder shall be mounted on the printed circuit board and contain both an operating fuse and a spare fuse. 4.6 Conduit shall be heavy wall, 0.2 in. (.1 mm). steel, cadmium plated. 5.0 Cabinet assembly 5.1 The cabinet assembly shall be fabricated from 14 gauge steel with a baked epoxy powder coating over a 5-stage pretreatment including iron phosphate, for protection from corrosive atmospheres. 5.2 The cabinet shall include two (2) 9/16 inch (14. mm) mounting holes located on the top. 5. Louvers shall be individually adjustable and made of anodized extruded aluminum. 6.0 Mounting Kits 6.1 The heater shall be provided with a steel mounting kit, with wet applied enamel paint, specifically designed to bear the weight of the heater assembly. 6.2 The mounting kit shall be - (select one): Type BMK - basic mounting kit Type WMK - wall mounting kit Type MK - hanging mounting kit 7.0 Thermostat Options 7.1 The heater shall be supplied with - (select one): Built-in, Copper free, 6-82 F (2-28 C) Explosion-proof. room thermostat mounted on the control enclosure side of the heater. Field installed, Copper free, 6-82 F (2-28 C) Explosion-proof room thermostat. 4.0 Control Center 4.1 The control center shall be completely factory prewired 2-116. 15

The Modine brand has been the industry standard since Arthur B. Modine invented and patented the first lightweight, suspended hydronic unit heater in 192. No other manufacturer can provide the combined application flexibility, technical expertise and fast delivery found at Modine. Consult your local Modine distributor for help in solving your indoor air problems. Products from Modine are designed to provide indoor air-comfort solutions for commercial, institutional and industrial applications. Whatever your heating, ventilating and cooling requirements, Modine has the product to satisfy your needs, including: Gas-fired unit heaters Gas-fired duct furnaces Gas-fired high-intensity infrared heaters Gas-fired low-intensity infrared heaters Steam/hot water unit heaters Steam/hot water cabinet unit heaters Steam/hot water commercial fin tube radiation Oil-fired unit heaters Electric unit heaters Indoor gravity vented single and multiple duct furnace make-up air units Indoor separated combustion single and multiple duct furnace make-up air units Outdoor single and multiple duct furnace make-up air units Direct-fired make-up air units With burner capacities up to 7,862,000 Btu/hr and air-handling capacities as high as 60,000 CFM, Modine products are compatible with every fuel type, including: Natural or Propane Gas Steam/ot Water Oil Electric Specific catalogs and computer-generated heat-loss calculations are available for each product. Catalogs 75-16 and 75-17 provide details on all Modine VAC equipment. Distributed By: Commercial Products Group Modine Manufacturing Company 1500 DeKoven Avenue Racine, Wisconsin 540-2552 Phone: 1.800.828.428 (EAT) Fax: 800.4.6011 www.modine.com Modine Manufacturing Company 07 Litho in USA 2-116.