RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Similar documents
Tank Gauging System Special Safety Instruction

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

4) Intrinsic Safety Certification

Annubar Flowmeter Series

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

INSTRUCTION MANUAL (ATEX)

SET Installation and Operating Instructions. Level switch for one sensor

IECEx Certificate of Conformity

SET-2000 Oil/Sludge 12 VDC

SET-2000 Hi Level/Oil

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Operating Instructions Edition 02/2007

MICROpeL 75 Combustible Gas Sensor Part Number: PM

User s Manual YTA610 and YTA710 NEPSI Certification

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Rosemount 752 Fieldbus Remote Indicator

OilSET-1000 (12 VDC)

Model 144H. Product Data Sheet , Rev DB February Content

DB5 Intrinsically Safe Sounder Type DB-5

OPTIBAR P 1010/2010 C Supplementary instructions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Model 144H. Product Data Sheet , Rev DB February Content

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Declaration of conformity

E2S Datasheet v10a

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

14300 MAINS SEPARATOR ALARM MANUAL

OPTIBAR DP 7060 Supplementary Instructions

OPTIWAVE X500 Supplementary Instructions

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

IRceL CH4 Methane (CH 4

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Certificate of Compliance

Technical Data. Dimensions

Installation and Operating Instruction

Supplementary Installation and Operating Instructions. Category II2G

RT FLOW RATE TOTALISER

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Rosemount 4500 Hygienic Pressure Transmitter. Start

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

Rosemount 3490 Series

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Solar Separator Alarm Type Installation, Operation & Maintenance

IECEx Certificate of Conformity

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

VERSAFLOW VORTEX Supplementary instructions

Universal Tank Alarm Type Installation, Operation & Maintenance

Rosemount 4500 Hygienic Pressure Transmitter

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

Inductive slot sensor

Intrinsically Safe Flame Detector Installation Guide

AND INSTALLATION MANUAL

Rosemount 8800D Series Vortex Flowmeter

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

PEPPERL+FUCHS GmbH

Intrinsically Safe Solutions

Safety instructions VEGAPULS 64

Technical Data. General specifications. Rated operating distance s n 5 mm

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Product Information to the manual

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 702 Wireless Discrete Transmitter

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Technical Data. Dimensions

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Installationsmanual GWSL1100/2100, GWML3100

Dräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Rosemount 8800D Series Vortex Flowmeter. Quick Start Guide , Rev FE October 2018

SOLAR SEPARATOR ALARM

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

Rosemount 3100 Series Ultrasonic Level Transmitters

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Transcription:

Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification code............................................. 2 Intrinsically safe (IS) entity parameters.............................................. 2 Instructions specific to hazardous area installations.................................... 3 Special Conditions for Safe Use (X)................................................ 4 2210 Display Unit European ATEX Directive Information............................. 5 ATEX marking and Ex Certification code............................................. 5 Intrinsically safe (IS) entity parameters.............................................. 5 Instructions specific to hazardous area installations.................................... 5 Symbols............................................................ Back cover www.rosemount-tg.com

en Special Safety Instruction European Union Directive Information TANKRADAR PRO EUROPEAN ATEX DIRECTIVE INFORMATION This document lists specific requirements which have to be fulfilled to secure a safe installation and use of TankRadar Pro in a hazardous area. Omission may jeopardize safety, and Rosemount Tank Radar AB will not take any responsibility if requirements as listed below are not fulfilled. Identification of output configuration Serial number: yyyy xxxxx year number Figure 1-1. Approval labels for the TankRadar Pro Radar Unit and antenna. ATEX marking and Ex Certification code Intrinsically safe (IS) entity parameters ATEX marking Safety coding Outputs II 1/2 G II (2) (1) 1/2 G II (1) 1/2 G EEx de IIC T6 (-40 to +70 C) EEx de [ib] [ia] IIC T6 (-40 to +70 C) EEx de [ia] IIC T6 (-40 to +70 C) Non-Intrinsically Safe (Non-IS) Primary and/or Secondary outputs IS Display output. IS Primary output, and/or IS Secondary output IS Display output. Non-IS Primary output The unit can be equipped with various types of outputs, each type of IS configuration has specific entity parameters. The output configuration is shown on the main label of each unit. Passive analog output 4-20 ma, Label identification = HART passive Voltage compliance 7-30 V, U i < 30 V, I i < 200 ma, P i < 1.3 W, C i = 0 µf, L i = 0 mh Active analog output 4-20 ma, Label identification = HART active Max load 300 Ω, U o = 23.1 V, I o = 125.7 ma, P o = 0.726 W, C ext < 0.14 µf, L ext < 2.2 mh FOUNDATION fieldbus, Label identification = FOUNDATION fieldbus U i < 30 V, I i < 300 ma, P i < 1.3 W, C i = 0 µf, L i = 0 mh 2

Special Safety Instruction en Instructions specific to hazardous area installations The TankRadar Pro has been certified to comply with Directive 94/9/EC of the European Parliament and the Council as published in the Official Journal of the European Communities No. L 100/1. The following instructions apply to equipment covered by certificate numbers Sira03ATEX1294X: 1. The equipment may be used with flammable gases and vapours with apparatus Group IIC. 2. The Transmitter Head is certified for installation in a category 1 (cat 1) area and for use in ambient temperatures in the range of -40 C to +70 C and should not be used outside this temperature range. 3. The antenna including tank seal is designed to be mounted across the boundary between a cat 1 and cat 2 area. There are various cat 1 areas within the range from -40 C to +400 C, -1 to 55 bar that can be considered. It is the responsibility of the user to select the appropriate antenna including tank seal to match the tank process conditions, see table below. Antenna type, size and tank seal material can be found on the antenna label. Antenna Type Cone Pipe Pipe ITG Cone Pipe Pipe ITG Size Tank Seal Material Temperature range All PTFE -40 to +200 C Pressure range (linear interpolation between breakpoints) -1 to 10 bar @ -40 C -1 to 10 bar @ 100 C -1 to 5 bar @ 200 C All Quartz -40 to +400 C -1 to 55 bar Cone/purging All PTFE -40 to +200 C -1 to 10 bar Cone/purging All Quartz -40 to +400 C -1 to 10 bar Process seal 4 / DN100 PTFE -40 to +150 C -1 to 5 bar @ -40 C 0 bar @ +150 C Process seal 6 / DN150 PTFE -40 to +150 C -1 to 2 bar @ -40 C 0 bar @ +150 C Process seal 4 / DN100 Ceramic -40 to +400 C -1 to 16 bar Process seal 6 / DN150 Ceramic -40 to +400 C -1 to 6 bar Rod All PTFE -40 to +200 C Rod100 Rod250 All PTFE -40 to +200 C -1 to 35 bar @ -40 C -1 to 35 bar @ 100 C -1 to 25 bar @ 101 C -1 to 25 bar @ 200 C 25 bar @ -40 C 25 bar @ 100 C 16 bar @ 200 C Parabolic 18 / Welded PTFE -40 to +230 C -1 to 10 bar Parabolic 18 / Clamped PTFE -40 to +230 C -0.5 to 0.5 bar 4. The product must be installed by suitably trained personnel and carried out in accordance with all appropriate international, national and local standard codes of practice and site regulations for intrinsically safe apparatus and in accordance with the instructions contained within this manual. 5. Repair of this equipment shall be carried out by the manufacturer or in 3

en Special Safety Instruction accordance with the applicable code of practice. 6. All externally connected intrinsically safe apparatus must comply with the specified IS entity parameters. 7. The Flameproof/Explosionproof enclosure may not be opened while energized. 8. The certificate marking is detailed on drawing numbers 9150076-931 and 9150076-932. 9. The certificate has special conditions for safe use associated with it, denoted by the X on the end of the certificate no., which must be observed when the equipment is installed. 10. If the equipment is likely to come into contact with aggressive substances, then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. Aggressive substances - e.g. solvents that may affect polymeric materials Suitable precautions - e.g. regular checks as part of routine inspections or establishing from the material's data sheet that it is resistant to specific chemicals Special Conditions for Safe Use (X) 1. As alloys may be used as the enclosure (or other parts) material and be at the accessible surface of this equipment, in the event of rare incidents, ignition sources due to impact and friction sparks could occur. This shall be considered when the equipment is being installed in locations that specifically require group II, category 1G equipment. 2. Under certain extreme circumstances, the non-metallic parts of the equipment may be capable of generating an ignition-capable level of electrostatic charge. Therefore, when used for applications that specifically require group II, category 1 equipment, the equipment shall not be installed in a location where the external conditions are conducive to the build-up of electrostatic charge on such surfaces. Additionally, the equipment non-metallic parts shall only be cleaned with a damp cloth. 4

Special Safety Instruction en 2210 DISPLAY UNIT EUROPEAN ATEX DIRECTIVE INFORMATION The 2210 Display Unit can be installed as a remote mounted local readout unit for Rosemount TankRadar Pro or be factory mounted attached directly to the Radar Transmitter Head enclosure. The remote version has an optional I/O terminal card TP40 for temperature measurement. The 2210 Display Unit is certified to comply with Directive 94/9/EC of the European Parliament and the Council as published in the Official Journal of the European Communities No. L 100/1. Serial number: yyyy xxxxxx year number Identification of optional TP40 temperature card Figure 1-2. Approval label for the 2210 Display Unit. ATEX marking and Ex Certification code Intrinsically safe (IS) entity parameters 2210 DU without TP40: II 2 G EEx ib IIC T4 (Ta = -40ºC to +70ºC) 2210 DU including TP40: II 2 (1) G EEx ib ia IIC T4 (Ta = -40ºC to +70ºC) Connector X2: Ui = 12V, Ii = 400mA, Pi = 0.7W Optional TP40, connector X17 and X18: Uo = 5.88V, Io = 172.4mA, Po = 0.253W The capacitance or either the inductance or the inductance to resistance (L/R) ratio of the cable connected to the connectors X17 and X18 must not exceed the following values: Gas group Capacitance µf Inductance µh or L/R ratio µh/ohm IIC 43 0.7 140 IIB 1000 5.2 560 IIA 1000 10 1120 Instructions specific to hazardous area installations The following instructions apply to equipment covered by certificate number Sira 00ATEX2062: 1. The equipment may be used with flammable gases and vapours with apparatus groups IIC, IIB and IIA and with temperature classes T1, T2, T3 and T4. 2. The equipment is only certified for use in ambient temperatures in the range -40 C to +70 C and should not be used outside this range. 3. Installation shall be carried out in accordance with the applicable code of practice. 4. Repair of this equipment shall be carried out in accordance with the applicable code of practice. 5. Certification marking as detailed in drawing numbers 9150 074-980 and 9150 074-981. 5

en Special Safety Instruction SYMBOLS The following symbols can be found on the TankRadar Pro and 2210 Display Unit. The CE marking symbolises the conformity of the product with the applicable Community requirements. The device uses non-harmonized radio frequencies. Protective Earth The Ex Certificate is a statement of an independent Certification Body declaring that this product meets the requirement of the applicable European Intrinsic Safety directives. Ground Power Supply The FM symbol indicates that the marked equipment is certified by FM - Factory Mutual Research Corporation according to FMRC standards and are applicable for installation in hazardous loactions. External cabling must be approved for use in min. 75 C. Emerson Process Management Rosemount Tank Gauging Box 130 45 S-402 51 Göteborg SWEDEN Tel: +46 31 337 00 00 Fax: +46 31 25 30 22 E-mail: sales.srt@emersonprocess.com Website: www.rosemount-tg.com 2003 Rosemount Tank Radar AB. All rights reserved.