Industrial Lighting and Safety

Similar documents
NECA S System Approach to Electrical Safety for NFPA 70E

Electrical Safety Compliance: NFPA 70E

Licensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115

NECA S System Approach to Electrical Safety for NFPA 70E

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Fire ground electrocution

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

ONTARIO Electrical Safety Report. 10th Edition

Investigation Report Worker Fatally Injured after Fall from Height November 10, 2014

How many time has your company been asked by an owner or customer to work on equipment energized?

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

NFPA 70E Edition Update

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

Pocket Alarm. IPLOCA Health and Safety Award 2012

PROTECTING AGAINST ARC FLASH HAZARDS

WORKPLACE SAFETY INSPECTION CHECKLIST

Common Area Cleaning Guide

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

Directive on Laser Safety. NRC Occupational Safety and Health Manual

Arc Flash Protection Training - NFPA 70e Electrical Safety

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

NFPA 70E Electrical Safety & Arc Flash Training

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST

HEALTH AND SAFETY INDUCTION CHECKLIST

DISTRIBUTION OPERATIONS AND MAINTENANCE

Before you begin. Introduction About construction work 1. Topic 1 How health and safety laws apply to you 3

How to reduce exposure to arc flash hazards

6/23/ National Electrical Contractors Association and Intec, Inc.

OSHA-Required Trainings Offered by Ultimate Risk Services

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

Evaluating Your Property and Work for Safety Hazards

ThamesWater Metering Managed Service. Office SHEQ Induction

Section: TABLE OF CONTENTS Lighting. 07.A General B Lighting Levels Minimum Lighting Requirements

Department Of Public Works: Internal Operations

Electrical Safety for Facility Managers and Building Owners

Sample Safety Inspection Checklist for Schools

In this issue of the Environmental Health and Safety (EHS) Listserv, December 15, 2011:

Breezair RPA Series Installation Manual

The safe way to verify the absence of voltage.

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

VISITOR SAFETY AND ORIENTATION BOOKLET

SAFETY INSPECTION REPORT

NECA. Standard for Electrical Safety in the Workplace

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

SAFETY EXCELLENCE AWARD 2014 TECHNICAL SUPPORT SAFETY SURVEY FORM FINAL EVALUATION

Electrical Safety Requirements

Shell Canada Limited Hydrogen Sulphide (H2S) Release September 12, 2006

SEL Arc-Flash Solutions

FLOORS & WALKING SURFACES Y N N/A Corrective Actions Are ALL employees wearing approved slip-resistant footwear?

Warehouse Operations Safety Inspection Checklist

Explosion at Battery Site Date of Incident: Type of Incident: Fatal

Manual Handling. Safety Talks for Small Business Part 1 of 9

Online Training Catalog - Employee Safety and Health. October 2013

CONTRACTOR GUIDELINES

Sample Safety Inspection Checklist

-SAMPLE- Safety Inspection Checklist: Manufacturing

SEL Arc-Flash Solutions

Mini-Rooter Operating Instructions

General Safety Instruction. (for Technical Staff)

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

Various tools (facilities), cleaning equipment and other computing equipment. Washing machines, ZIP taps. TV screens.

Safety Best Practices Manual

NFPA 70E Elevates Safety. with Heightened Risk Awareness

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE

PORTABLE HAND POWER THREADER 1/2-2

Robin Clark Health & Safety Coordinator

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

Typical Installation Breaker Box Class A 50 amp, 120/240 volt, GFCI

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

Electrical Preventive Maintenance (EPM) Program

Oil Sands Safety Association (OSSA) Regional Orientation Program

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

Promoting Electrical Safety through NFPA 70E Standards Adherence

Brian McCauley December 2017

Workplace Safety Observation Tour Notes

96KY125. Date: 10 March Subject: Pug Mill Operator Killed After Entanglement SUMMARY

Rutgers Environmental Health and Safety (REHS)

Fire/General Safety Review Program Key Performance Indicators Environmental Health and Safety

Refurbishment or New Site Spot Check Checklist

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities Electrical Emergencies Revised

CVCSD Bakersfield March 19, 2015 Facility Incident Case Studies

Facilities Services Utilities Shutdown Request Form

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

ELECTRICAL PANEL SAFETY ALERT I N S T I T U T E

2014 National Electrical Code & NFPA 70E/Arc Flash

DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control

Electrical Hazards and NFPA-70E: Protecting Your Employees

Employee Health Protection

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

Electrical Safety Program.

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

Laboratory Inspection Checklist

OH&S WORKPLACE ASSESSMENT INSPECTION CHECKLIST

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

MONTHLY SAFETY INSPECTION REPORT

ETCI Safety Committee TC5. Report for 2013

Transcription:

Industrial Lighting and Safety Can Can you see the problem? WMEA Meeting, Calgary, June 9, 2005 Mick Walton Tim Driscoll George Brady Richard Loiselle BJ Electric Sales Shell Canada Syncrude Canada Suncor Energy 1

Agenda Introduction References Background Information Actual Data - Surveys & Incident Data Illumination Considerations - Design & Maintenance Safe Work Practices - Fatality Case Study Conclusions & Recommendations Fatality Case Study 2 (if time permits) 2

Introduction Do we pay enough attention to lighting? Is there data to substantiate a closer look? Can safety performance be improved by paying attention to lighting? We can not run our facilities without lighting! The round-the-clock industrial revolution was enabled by lighting 3

References Much of the data presented in these slides comes from ANSI/IESNA RP-7-01,Recommended Practice for Lighting Industrial Facilities Occupational Health & Safety (OH&S) rules quoted are from the Alberta (Canada) code The statistical data and incidents are quoted from major petroleum companies operating in Alberta, Canada 4

Background The better the lighting conditions, the more productive we are. Relative illumination needed by different age groups to carry out a specific eye-task Age Seeing Ability 10 Years 1 20 Years 1.5 30 Years 2 40 Years 3 50 Years 6 60 Years 15 5

Background In 2002, David Berson of Brown University detected a novel third photoreceptor in the retina of mammals which is directly connected to the biological clock of the brain. In short and simple terms, application or reduction of light to the eye can switch our bodies on and off. 6

Background Illuminance vs Incident Frequency 7

Actual Data - Survey Is there a good understanding among workers about what is safe light working conditions? Anonymous survey sent to plant technicians 3 major petroleum companies data next page 8

Actual Data - Survey Positive Responses 30% 86% 83% 96% 75% No. of electricians aware of incidents related to lighting No. of electricians reluctant to change some lamps due to location Lighting maintenance seen as a low priority Feel their facilities lighting is inadequate 0% 20% 40% 60% 80% 100% 120% Do Not understand lighting levels or specs 9

Actual Data - Incident Statistics A small percentage of overall incidents but suspect significant under-reporting In the last 3 years, a large petroleum facility has experienced, due to inadequate illumination 2 Lost Time Incidents 5 Medical Aids 28 First Aids 10

Actual Data - Incident Statistics Another company s 5-year records show that due to slips, trips and falls 18% are Medical Aids 58% of all serious injuries occurred, and A disproportionate number occur at night Rarely during investigations was poor lighting considered! 11

Actual Data - Incident Statistics Incidents by Time of Day 300 250 200 150 100 50 0 1992 1993 1994 12

Actual Data - Reporting Data is sometimes available through the incident reporting systems. Until a better focus and knowledge base is achieved, the data is likely distorted. There is a great deal of circumstantial evidence: Work order requests Industrial Hygiene complaints Accidents during night time hours. 13

Actual Data - Incident Samples First Aid - Employee was walking in poorly illuminated area between trailers and slipped on ice resulting in bruised knee. First Aid - Employee was descending poorly illuminated steps carrying tools and caught 1/2 of a step resulting in a sprained ankle. First Aid - Employee was responding to fire alarm, walking down poorly illuminated piperack, when he stepped on an object, tripped and hurt knee. 14

Illumination Rules OH&S Governs Workplace Safety and states, in General Safety Requirements Rule 186.1, that an employer must ensure that lighting at the work site is sufficient to enable work to be done safely OH&S Refers to the IES (Illumination Engineering Society) for Recommendations for Safe Lighting Levels 15

Illumination - IES IES (ANSI RP 7-01) is the prime reference RP 7-01states that any factor that aids visual effectiveness increases the probability that a worker will detect the potential cause of an accident Main recommendations for illumination levels, interior and outdoors respectively 16

Illumination - IES Interpretation & Considerations Suggests a minimum of 20 foot-candles on all industrial tasks where there is a sustained seeing requirement 3 Dimensional Viewing (Time, Location, Plane) Uniform lighting levels (low Max / Min ratios) Minimize Glare with appropriate refractors High efficiency / long lasting light sources used in hard to reach areas ( Induction Lamps) 17

Illumination - IES Interpretation & Considerations Long term maintenance (considers lamp degradation, environmental factors) Lamp Degradation Cleanliness 18

Illumination Design Lighting specification sources User specifications Manufacturer and engineering company standards, specifications, software Some of these may be weak and/or inconsistent, construction often not audited. Not generally a high priority with users 19

Illumination Design Other Considerations Installation details - maintenance friendly? Appropriate controls to ensure lighting is off when not needed (energy consumption, longer lamp life, less maintenance) Documentation Often poorly done as cabling is field run Sub-optimal for O&M 20

Illumination Maintenance Group re-lamping programs Help maintain the designed min. lighting levels Therefore improving long term safety (trips, slips, etc.) Better management of waste material containing mercury, lead, arsenic, cadmium Lighting controls - higher end microprocessor based solutions available Minimizes lumen degradation over time Also energy savings 21

Safe Work Practices 22

Safe Work Practices Prime Hazards Fixtures located at Inaccessible Locations Usually elevated, therefore risk of falling High percentage of work is Energized Difficult to find disconnect device Considered low voltage and low risk by many electricians Both hazards often occur together making Lighting Work Extremely Hazardous! 23

24

Safe Work Practices Elevated Locations Examples Ceilings Stanchion mounts off walkways, platforms Light poles Sides of buildings Accessing Ladders, scaffolds Fall protection Worker must be protected by railing Above a specified height, fall protection is required. 25

Safe Work Practices Elevated Locations Issues Troublesome to get proper equipment for small job Ladders, scaffolds $$$ and/or time consuming Accessing often involves reaching Appropriate procedures E.g. securing ladders Use of correct equipment E.g. fall arrest, non-conductive ladders 26

Safe Work Practices Energized Work Considered Low Voltage However, many voltages >120 V often found E.g. 240, 277, 347, 480, 600 Volt Info. (drawings/schedules) identifying the breaker/disconnect often missing or inaccurate Disconnect is often inconveniently located Troubleshooting often considered easier if done energized Energized work considered part of electrician s job Others in area want lights on while you fix a light 27

Hazardous Locations Safe Work Practices Other Hazards Arcing (e.g. wiring work, lamp changing) Hot surfaces Hot Work procedures / permits needed Lighting considered low priority in Industrial Process and engineered equipment has priority Hazardous Task Analysis or Field Level Risk Assessment often not conducted 28

Safe Work Practices Lighting Case Study - Fatality Petroleum Facility, October 1998 Job: Repair light fixture that was not working The Incident Electrician to fix fixture at elevated location Remote ballasted Aluminum ladder to access the fixture Majority of work was performed energized Electrician was startled by an arc or shock Fall resulted in a fatal injury 29

An Aluminum (conductive) ladder was selected. It was supported by the conduit and tied-off with rope. The fixture was unhooked from it s JB, lowered and secured with rope so that the wiring could be accessed 30

One wire had become disconnected on the fixture and was pulled into the fixture s conduit when it was dropped down. (This is why the fixture was not working) The wire then contacted the fixture s conduit. 31

The remote ballast was located Voltage was measured leaving the ballast 32

The electrician proceeded to check that voltage was present at the fixture. Note that the fixture frame is now disconnected from ground, so it will not trip the breaker. 33

The fixture was swinging loosely, and contacted the ladder, which was leaning on the conduit (arcing was found on the ladder) The electrician was either startled by arcing or received a shock while working on the wiring. This caused a fall as he was not wearing any fall protection. 34

He fell through this gap in the platform and a further 6m below, receiving a fatal injury to the head. 35

Safe Work Practices Incident Learnings Hazardous Task Analysis Identify all hazards - shock, arc, fall Identify all mitigating measures e.g. PPE, fall arrest, grounding, special procedures Avoid energized work Fixture can be checked on the bench Wire continuity can be checked de-energized Use correct equipment Fall arrest Non-conductive ladder Gloves, etc. 36

Safe Work Practices Design Improvements Easily located disconnects Individual fixture disconnects Plugs / receptacles located near fixtures Switches / disconnect terminals in fixtures Automatic switch disconnects in HazLoc fixtures Drawings/Documentation Up-to-date identification of distribution panels Up-to-date identification of lighting circuits in those panels, and at those panels Lockable circuits in panels Use lower voltage lamps 37

Safe Work Practices Design Improvements Accessible Locations Several methods available to move the fixture to the worker (rather than worker to the fixture) Winch poles, rotating poles, stanchion mount sliders Use existing walkways / platforms / stairs Mount fixtures so they are easily reachable 38

Rotating/Swivel Pole 39

Conclusions and Recommendations Incidents Better awareness of lighting as a causal factor Systems which enable identifying lighting factors Recording, tracking and trending data Disseminate learnings Take corrective actions Mobile equipment lighting incidents are higher (the data presented was from fixed facilities) 40

Conclusions and Recommendations Design Illumination levels Ensure proper interpretation of standards Maintained minimum levels Consider Glare issues Consider operability and maintenance requirements Lighting obstructions 41

Conclusions and Recommendations Maintenance of Illumination levels Lighting surveys Group re-lamping & controls Consider temporary obstructions E.g. hoardings, scaffolds, etc. Safe Work Practices Education Recognition and management of the hazards #1 - Avoid Energized work Falls, LO/TO, HazLoc, Task Analysis, Tools, etc. 42

43

Case Study 2 Not originally part of this presentation Not Lighting related This incident demonstrates why We cannot rely on one barrier to prevent incidents We need to use many barriers, including: Inherent safety Training Work Practices & Procedures PPE Things Can Go Wrong! 44

Case Study 2 An experienced contract line crew just finished installing a 25 KV cable from an overhead power line to a transformer Safety Std s existed contractor was not informed Site Prime Contractor thought Utility was in control I.e. responsibilities (safety/work) were not clear Tailgate meeting held Line Crew only Numerous communication breakdowns Eng. Contractor, Prime Contractor, Owner, Line Crew, Utility Crew had tapped the 25 KV line energized Verbal approval by the Utility Line Crew and Utility worked together in many areas Owner was not aware of, nor the Prime Contractor 45

Case Study 2 Late in the day / long weekend / pressured to finish A test was required to verify voltage and phasing A Utility req't. not an Owner or Eng. Contractor req't. The lineman: Had a backhoe operator hold a 750 V meter Put on 17 KV gloves Then tested the 25 KV terminals at the transformer The result: Fatal shock to backhoe operator (worked with for 20 yrs.) Shock (step & touch) to observing apprentice 46

Primary side of 25,000 / 600 v transformer Primary-side door was open Secondary-side door (other end) was locked 47

Amprobe meter and leads - rated for 750 volts 48

Primary-side fuses and bushings Burn mark (from glasses?) Burn mark (from watch?) Points of contact with leads 49

Positional Re-Enactment Worker # 2 - deceased Worker # 1 - uninjured Worker # 3 - injured 50

? 51