KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

Similar documents
KWX- N1 N2 N3 N4 Remote Monitored PDU

General. General. Input. (1) 16 AMP Circuit Breaker. Communication. (1) RJ45 for Ethernet. Current Meter. Operation. Nominal Input Voltage 230V

RACK MONITORING SYSTEM - RAMOS Ultra

RACK MONITORING SYSTEM RAMOS Ultra

ECO PDU PE7214/PE7216/PE7324/PE7328

Typical applications include the vibration detector. Detection of vibrations and shocks

CAN unit for Analog Sensors

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Innovative Circuit Technology Ltd.

Outdoor Temperature Sensor

DTS MOBATime's Distributed Time System

IndigoVision Alarm Panel. User Guide

Innovative Circuit Technology Ltd.

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Knürr RMS Compact II. Knürr RMS Compact II 2.81

GPS or DCF 77. DTS Masterclock

SYSTEM OVERVIEW. Environmental Monitoring. Simplified.

PSM CONTROL & MANAGEMENT PRODUCT CATALOGUE. GAMATRONIC, A SolarEdge Division. 17 Hartom Street, Jerusalem , Israel

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Galaxy Pulsar Plus Digital Battery Plant Controller

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Alarm module for leak detection with webserver

>>> Rack Environmental Management

ACTIVE INFRARED BARRIER

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

Monitoring Solutions

Instruction Manual. Satellite Switched, Power Monitoring Unit. RS2 Series

AirFlow Sensor for Dry Contact connection

Dominion PX. Intelligent Rack Power Distribution. Dominion PX Series. Broadest portfolio of smart PDUs to enable energy management in the data center

Instruction Manual. Digital Recorder. Model SDR-304. Make sure all the accessories are supplied together. Introduction Connection. Operation.

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

LORAIN CIP 4890/48120 DC Power System

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

LORAIN CSP DC Power System

Remote / Network Control for Rack Cabinet Access - DL Series

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

DATAssure. Laboratory wireless alarm & monitoring system

Operating instructions MEW01643 Revision -

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

CAREL heatersteam Electric Element Steam Humidifiers

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Compact Ultra Low Temperature Chamber

securityprobe SNMP-based Environmental and Security Monitoring Solution

Supervisor OPERATIONS MANUAL. Heat-Tracing Controller Configuration and Monitoring Software. Versions up to 2.7xx. INSTALL-118 (Europe)

CMC-TC Basic CMC DK

MiNi Server environment MoNitoriNg SySteM

X.90 Access Control System

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

CMC-TC Processing Unit II Assembly, Installation and Operation Manual

ThermoControl 0 C - 10 C - 20 C - 30 C

User-Manual MultiSensor-RACK. From Firmware Version 3.xx.xx.

VDC-HD3300/HD300P VDC-HD3100/HD3100P

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Configuration and Operation Manual for the Unipos

Universal Monitoring System. TrapServer Description

Didactum Monitoring System 50

Trident User s Manual

Installation Manual COPYRIGHT NOTICE

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

Powercom Ltd Powercom Building A, Ramat Hakovesh Israel Tel: +972 (9) Fax: +972 (9)

CMC- Top Concept A redefinition of rack security

Rack Airfl ow Control. User Manual. CMS-02-S, Master IP Fan unit GUI & SNMP. Designed and manufactured by Austin Hughes

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

PowerLogic ION Setup Meter Configuration Software Configuration Guide

CMC-TC Processing Unit II DK

1.1 Ethernet Remote Annunciator Controller (RAC) using the up to 4 ATC-300+ connected via RS-485 to TCP/IP gateway

Liebert LDMF Distribution Monitoring. User Manual

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.

idware Idware Remote Site Monitoring Solution

Soft Start Series MP700 Solid State, Reduced Voltage

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

EC-BOS-602/616 AX Security

SIMPLICITY BY DESIGN M52 CONTROLLER

USER MANUAL CONTEG USER MANUAL. for the next decade! CONTEG SOLUTIONS. ...to complete your network. version: CONTEG, spol. s r.o.

NU2 Smart Power Supply (SPS) Manual

Lighting Xpert Insight User Manual

Protecting Network Data

Added password for IP setup page : Password must be in IP format!

MultiSite Manager. Setup Guide

APPLICATION DATA SHEET

Instruction Manual Environmental Monitoring Unit with Output Relay

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

User manual for CPR32-NET network controller

Remote fiber testing to improve SLA s

TELSEC MINI PRO User Guide

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Didactum Monitoring System 100 III

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Data Center. Cold Storage

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

KMF Environmental test chamber for constant climate

HPE Modular Cooling System 200 User Guide

Annunciator Unit SACO 16 D1. Product Guide

Chilled Water Precision Air Conditioner for Critical Application

Transcription:

PDUeX as standard where others don t!! The most innovative PDU on the market Monitor Each Sockets Current Control each outlets on/off Sequential power on/off User can define the sequence of order in which outlets will be switched on. Power Status Holding Monitor the Total Current Intelligent, Rack Mounted, Power Distribution Units Monitor the Input Voltage Monitor the total kwh Power Factor Recognition Monitors Input & Output Voltage 10 x Individually Fused Sockets KWX N4 PDU KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU 55 C Hot Rack Operating SMS, SNMP & Email Notification C13 IEC Locking as Standard Built in Environmental Monitoring Technology as Standard Up to 8 Sensors, Plug n Play Sensors Humidity Water Logging Infrared Alarm INPUT CURRENT Total kwh INPUT VOLTAGE Current Display Energy Display Voltage Display Door Alarm Temperature Smoke Alarm SNMP MP P Dry Connector for Audible Alarms Protocol Intelligent Outlet Type & Number Recognition Teln nett/s /SSH /SS com m E-mail Alarm 24v and 48v, Single Phase 120v & 240v, 3 Phase 400v RS 485 48 85 link Daisy Chain RS 485 Web Browsing Bade Server Ready Dry Connector 19 or Vertical

KWX-N4 Remote Monitored PDU KWX-N4 series is our remote monitored PDU that supports multitask and multiuser access. The software supports various TCP/IP protocols, Including: HTTP, HTTPS, SSL, SNMP, TELNET, SSH, SMTP etc. to monitor the voltage, total current, the rack environment and the KWX-N2 & KWX-N4 also monitors each ports current and switch on/off per port. Socket Types SNMP MP P Teln nett/s /SSH /SS Example of the reverse of KWX-N16A8C3 E-mail Alarm Web Browsing Protocol Temperature Humidity Water Logging Smoke Alarm Infrared Alarm Dry Connector 19 or Vertical RS 485 48 85 Dimension 19 Horizontal (W x D x H) 19 x 206.9mm x 44.4mm Vertical mounted (L x W x D) A x 58mm x 44.4mm A = length can be customized Door Alarm RS 485 INPUT CURRENT Total kwh INPUT VOLTAGE Current Display Energy Display Voltage Display Each Port on/off

8.8 245 8.8 245 8.8 245 8.8 245 KWX-N16A10C3-H4F KWX-N4 series is the new generation of PDU. It combines network power distribution, environmental monitoring technology and provide real-time remote power consumption of total current load and voltage. Total PDU Current Monitoring, Outlet Switching, KWX series can be accessed via LAN /WAN or over serial interface. KWX-N4 series is a remote monitor PDU with embedded multithreading inner core RTOS (Real Time Operating Systems), that supports multitask and multiuser access. The software supports various TCP/IP protocols, including HTTP, HTTPS, SSL, SNMP, TELNET, SSH, SMTP etc. Provides: Sensors recognition, Ability to cascade up to 4units, Monitor the total current, Monitor the total kwh, and Monitor the input voltage Alarm settings: Total current limit, Temperature limit, Total current over limit alarm, Humidity over limit alarm, Smoke Alarm, Water logging alarm, Infrared enter alarm, Door open alarm, dry connection. It offers: Monitor only PDU Power consumption, Switchable, Power factor recognition, Monitor the input voltage, 10 x Individually fused outlets, 10 x lockable IEC C13. : Temperature and humidity, Smoke alarm, Water logging alarm, Infrared alarm, Door open alarm. Radiation Connection KWX-N GROUP 1 KWX-N Slave KWX-N Slave KWX-N Master KWX-N Group 2 KWX-N Group 3 KWX-N Group... KWX Hub Daisy-chain 4pcs KWX-N at most Switch Remote Operator Local Operator KWX-N Slave Router WAN

KWX-N16A10C3-H4F Part number KWX-N16A10C3-H4F Product series KWX-N series 4 Product Size W x D x H = 19 x 206.9 mm x 44.45 mm Mounting length 465 mm Case color Net Weight Socket type Output Socket Power Input Black 3KG 10 x Lockable IEC-C13 IEC-320 C20 16A Function Illustration Parameter Note Working voltage Normal working AC90~250V Input/output current Max input/output current 16A 10A Working band Under normal working 47~60Hz Net port Via WAN or LAN monitor access 10/100Mb Adaptive Networking Access Serial port Via Serial port monitor access RS485 port Sensor port Sensors access RS485 port HTTP/HTTPS Web browser access Adapt IE Fire fox inner core browser, support SSL; Access way TELNET Simple command lines access / SSH Encryption command lines access Support SSHV2 version SNMP Support SNMP for centralized monitor Adapt SNMP v1, V2 Operation system compatibility Support various operation system Windows/winsta/win7/linux etc. Secondary development Software upgrade Alarm limit settings Display, Indicate Menu button operation Management Log record Used for system integrate Opening protocol TELNET SSH RS485 Customized protocol Manage software load Support manage software upgrade Software on circuit Support software upgrade on the circuit of hardware Total current limit Temperature limit Auto identify limit rationality Humidity limit Outlets indicators Each outlets with a indicator Nixie tube show the current/voltage, 6 digital indicators inquiry products information, Alarm information; Inquiry information On/off Alarm sound, Dry connect User right limit Outlets grouping clock synchronization Alarm log Inquiry product information, Alarm information, current etc. Close/ open alarm sound and dry connect output, Dry connect have normal open/off two choice, passive, touch spot can connect 2A 250VAC Administrator, Normal user Make group over PDU self sockets limit Regulate PDU system clock Alarm log circle, Inquiry, export, stock, delete available

Control each outlets on/off Each outlet breaking capacity 16A 250VAC Control Monitor Outlets alarm settings Protection Intelligent recognition Sensors in Cascade chain The interval of sequential power off time: Sequential power on/off 0.5s, Sequential power on 1~250s, user-defined Power status holding When PDU restart power, Each outlets will remain the status before Manage software load Support manage software upgrade Resolution:1V Monitor the input voltage Meter range: 90~350V Resolution: 0.1A Monitor the total current Meter range: 0.1~40A Monitor the total kwh Resolution: 0.1KW H Accuracy: 1 grade Resolution: 1 Monitor Environment Temperature Meter range: -30~100 Resolution: 1% Monitor Environment Humidity Meter range: 01~99% Monitor Environment Smoke Max: 25 m² available Monitor water logging Water logging or drop monitor Infrared monitoring The max monitor distance: 16m Door open monitor Min. 5mm open distance available Surge protection failure monitor PDU still normal working when failure Each fuse failure alarm Total current over limit alarm PS/PN series local alarm ways: PDU buzzer alarm, sound and light alarm, Dry Temperature over limit alarm connect; Humidity over limit alarm PN series remote alarm: E-mail, SMS, SNMP TRAP, WEB page notice, Smoke Alarm TELNET/SSH notice Water logging alarm Infrared enter alarm Door open alarm Surge protection failure alarm KWX-N series remote alarm: E-mail, SMS, SNMP TRAP, WEB page notice, Surge protection Difference mode:±2kv Common mode ±2KV flux: 3KA The max discharge current: 5KA Each way with fuse Breaking capacity : 1500A; Protect main line break, facility, power line suffering, Fuse range: 0.1~16A Circuit Breaker protection Breaking capacity : 6000A Recoverable overload protector Overload protection Outlets recognition Automatic read the sockets type and numbers Sensors recognition Sensors port no need be defined, Automatic read the sensors type and numbers Limit recognition When over limit, setting failure The MAX output current and PDU power Help user to limit facilities connect number and type Power factor recognition Help user to know the current consuming apparatus 1 ~ 8pcs same or different sensors connect in one PDU KWX-N with KWX-N Cascade KWX-N with KWX-S Cascade Flexible sensor input, extend and choose, Customized for new sensors Directly connection via net cable; Via HUB 4 sets Cascade at most Directly connection via net cable, 4 sets Cascade at most

KWX Model Numbers Please specify series by character highlighted in red and your model type in green eg: KWX-N16A10C3-H4F KWX-N/S16A8C3-H1/2/3/4F KWX-N/S16A10C3-1/2/3/4 KWX-N/S16A8Schuko-1/2/3/4 KWX-N/S16A12C3-1/2/3/4 KWX-N/S16A12C3C94-1/2/3/4 KWX-N/S16A20C3C94-1/2/3/4 Bespoke Requests Custom build options With our UK manufacturing capability PDUeX can build to your specifications with our market leading 2 week turn round, including: ݱ Surge Protection and SMS SNMP Email Alarm ݱ Individually Fused Outlets ݱ Recoverable Overload protection ݱ Socket types & number ݱ 1u/2u Up to 72 outlets ݱ Modbus RS485 Please contact the PDUeX team for assistance: Tel: 01823 662414 or email: info@pduexpertuk.com

KWX PDU SENSORS Door Sensor Infrared Sensor Temperature/ Humidity Sensor Smoke Sensor Water Logging Sensor