Fan Coils & Accessories The World s Quietest Fan Coils
The Affordable GREEN Solution Efficiency Comfort Reduce carbon footprint, save energy, Reduced operating costs No refrigeration in the building Unmatched zoning capabilities Whisper quiet operation Environmentally friendly Simple, reliable and proven worldwide The World s Quietest Fan Coils Available in 8 sizes and versions: FCX US FCX USP speed fan unit Full compliance with safety regulations Soft, flowing lines Automatic poweroff function with closure of the air delivery louver Broad range of controls Metallic protective cabinet with rustproof polyester paint Low noise operation Reduced pressure drops across heat exchangers Motors with permanently connected condensers Easy installation and maintenance Air filter easily removed and cleaned Removable blades for easy and effective cleaning Water connections reversibility during installation
fcx us = Cooling = Heating Model FCX Heating capacity Heating capacity Water flow rate Water pressure drops Total cooling capacity Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drop Air flow rate Fans Sound pressure Sound power Water contents Max. motor power Max. input current Coil connections R Coil connections 1R Watts (max.) Watts (med.) Watts (min.) gpm ft. W.C. Watts (max.) Watts (med.) Watts (min.) gpm ft.w.c. cfm (max.) cfm (med.) cfm (min.) no. db (A) (med.) db (A) (min.) db (A) (med) db (A) (min.) gal Watts Amps Ø FPT Ø FPT US 8860 700 4980 595 060 1460 0.99 1.14 4980 4400 500 1460 190 105 690 60 590 0.99 1.46 170 10 80 1 9.5.0.0 41.5 1.5 0.1 5 0.4 US 1950 10650 8800 795 10 580 1.58.5 7950 6810 510 0 1995 155 5890 500 860 1.58 4.17 65 05 155 8.5.5 5.5 41.0 4.0 0.9 44 0.4 4 US 1960 16700 10 5645 4895 905..80 1160 980 7660 00 70 45 80 6870 5670..59 55 70 195 5.5 8.5 7.0 0.9 57 0.56 50 US 40 19600 14110 6575 5745 415.75.78 1890 1060 940 4070 55 760 1070 890 6960.75 4.85 45 55 5.5 4.0 0.9 67 0.70 6 US 640 8490 1680 9860 850 655.19.7 16110 15440 1090 470 455 85 1190 1140 9690.19.91 540 45 05 47.0 40.5 1.5 55.5 49.0 40.0 8 0.80 8 US 9410 4750 8050 11550 10185 80 4.54.65 890 180 15610 6710 540 4575 16940 1480 11550 4.54.9 670 550 410 5.5 106 0.98 10 US 4410 9680 710 1985 1160 9585 5.01.76 550 660 0780 7400 695 6090 18660 17500 1570 5.01 4.8 765 660 50 56.5 5.5 46.5 65.0 55.0 11 1.16 Power supply = 115 V 1 60Hz. Performance values refer to the following conditions: Sound pressure measured in an 000 cu ft semireverberant test chamber with reverberation time Tr = 0.5s. Cooling: room air temperature 80 F (6.7 C) D.B., 67 F (19.4 C) W.B.; water inlet temperature 45 F (7. C); max. speed; water Dt 10 F; (1 C) for medium and low speed, water flow rate remains same as at maximum speed. Dimensions (inches) Heating: room air temperature 70 F (1.1 C); R.H. 50%; water inlet temperature 140 F (60 C); maximum speed; water Dt 10 F; (1 C) for medium and low speed, water flow rate remains same as at maximum speed. Model FCX Weight A B lbs US 19.18 9.55.0 US 19.18.61 4 US 19.18 47.8 5.8 50 US 19.18 47.8 5.8 6 US.4 5.0 74.8 8 US.4 5.0 74.8 10 US.4 5.0 74.8
fcx usp = Cooling = Heating Mod. Heating capacity Heating capacity Water flow rate Water pressure drops Total cooling capacity Total cooling capacity Sensible cooling capacity Water flow rate Water pressure drops Air flow rate Fans Sound pressure Sound pressure FCX PO Sound power FCX PO Sound power Water contents Max. motor power Max. input current Coil connections (FPT) FCX USP Watts (max.) Watts (med.) Watts (min.) gpm ft. W.C. Watts (max.) Watts (med.) Watts (min.) gpm ft.w.c. cfm (max.) cfm (med.) cfm (min.) no. db (A) (med.) db (A) (min.) db (A) (med.) db (A) (min.) gal Watts Amps Ø (4R) Ø (R Ø (1R) 8860 700 4980 595 060 1460 0.99 1.14 4980 4400 500 1460 190 105 690 60 590 0.99 1.46 170 10 80 1 9.5.0.0 41.5 1.5 0.1 5 0.4 4 1090 85 570 015 440 1680 1.1 0.59 5715 4965 805 1675 1455 1115 45 670 815 1.1 0.75 170 10 80 1 41.5 4.5.5 49.5 58.0 50.0 4.0 1.0 0.6 54 0.50 1950 10650 8800 795 10 580 1.58.5 7950 6810 510 0 1995 155 5890 500 860 1.58 4.17 65 05 155 8.5.5 5.5 41.0 4.0 0.9 44 0.4 4 155 165 1000 4465 700 940 1.84 1.76 980 810 6790 70 80 1990 6875 6005 5015 1.84.6 65 08 155 9.5.5 5.5 5.5 41.0 4.0 0.40 97 0.90 4 1960 16700 10 5645 4895 905..80 1160 980 7660 00 70 45 80 6870 5670..59 55 70 195 5.5 8.5 7.0 0.9 57 0.56 44 80 18050 1545 6560 590 970.9 5.10 14740 155 9845 40 670 885 10900 965 785.9 6.5 55 70 195 5.5 8.5 50.0 58.5 7.0 0.50 111 1.0 50 40 19600 14110 6575 5745 415.75.78 1890 1060 940 4070 55 760 1070 890 6960.75 4.85 45 55 5.5 4.0 0.9 67 0.70 54 690 810 1640 7705 6685 4760.48 6.86 17555 15795 11995 5145 460 515 1990 11690 8875.48 8.79 45 55 5.5 50.5 59.0 4.0 0.50 8 0.7 6 640 8490 1680 9860 850 655.19.7 16110 15440 1090 470 455 85 1190 1140 9690.19.91 540 45 05 47.0 40.5 1.5 55.5 49.0 40.0 8 0.80 64 75 9955 140 10910 8780 6490 4.17 4.51 105 1890 14910 6165 560 470 15560 150 11040 4.17 5.78 540 45 05 48.5.5 5.5 6.0 57.0 4.0 0.90 97 0.96 8 9410 4750 8050 11550 10185 80 4.54.65 890 180 15610 6710 540 4575 16940 1480 11550 4.54.9 670 550 410 5.5 106 0.98 84 4450 755 9170 1050 11000 8550 5.65 4.70 8490 5180 0780 850 780 6090 1085 1860 1570 5.65 6.0 670 550 410 5.5 55.5 64.0 0.90 15 1.4 10 4410 9680 710 1985 1160 9585 5.01.76 550 660 0780 7400 695 6090 18680 17500 1570 5.01 4.8 765 660 50 56.5 5.5 46.5 65.0 55.0 11 1.16 Power supply = 115 V 1 60Hz. Performance values refer to the following conditions: Sound pressure measured in an 000 cu ft semireverberant test chamber with reverberation time Tr = 0.5s. Cooling: room air temperature 80 F (6.7 C) D.B., 67 F (19.4 C) W.B.; water inlet temperature 45 F (7. C); max. speed; water Dt 10 F; (1 C) for medium and low speed, water flow rate remains same as at maximum speed. Heating: room air temperature 70 F (1.1 C); R.H. 50%; water inlet temperature 140 F (60 C); maximum speed; water Dt 10 F; (1 C) for medium and low speed, water flow rate remains same as at maximum speed.
Ventilcassaforma VentilCassaforma has been designed to respond to the needs to rationalise spaces to suit modern interior architecture. VentilCassaforma is a galvanised template that makes it possible to make a space to house fan coils in the wall. Whisper Quiet Comfort. Dimensions (inches) CH U 1 L 17 L 7 L 7 L A 7. 7. 7. 7. A1 5.5 5.5 5.5 5.5 B 7.4 1.6 40.6 49.9 B1 5.5 9.7 8.74 47.4 Depth C 7. 7. 7. 7. CH F 17 4 6 A 8.66 8.66 8.66 8.66.79 A1 6.9 6.9 6.9 6.9 1.06 B 8.81.15 4.4 50.90 55.67 B1 6.9 1.6 40.5 49.0 5.78 Depth C 9.45 9.45 9.45 9.45 9.45 Outer frame and closure panel CH U 1 L 17 L 7 L 7 L A 8.5 8.5 8.5 8.5 A1 5 5 5 5 A.75.75.75.75 A 19.45 19.45 19.45 19.45 B 8.07.4 41.46 50.11 B1 4.9 9.5 8.0 47 CH F 17 4 6 A 9.9 9.9 9.9 9.9 4.1 A1 6.77 6.77 6.77 6.77 0.91 A.66.66.66.66.66 A 19.41 19.41 19.41 19.41.54 A4.7.7.7.7.7 B 9.65 4 4.07 51.7 56.5 B1 6.5 0.8 9.9 48.6 5.5 A4
Flexible Applications Free Standing InWall Ducted Thermostats UV Light Technology: Improving Indoor Air Quality The Aermec Fan Coils can be equipped with a state of the art UV tube which improves indoor air quality by killing off air born dust mites, pollen mold and bacteria, which are harmful to our bodies. FMT 10 The FMT 10 Control Panel for FCX US series fancoils can be installed on board the conditioning unit.the assembly kit consists of the panel, the panel bracket for onboard assembly and electrical connectors. Each panel controls a single fancoil. The control panel includes: On/Off switch; speed fan operation selector FMT 0 The FMT 0 digital thermostat with basic functions, is a control panel for remote control of the FCX US series fancoils. The panel consists of an electronic thermostat that orders fan operation cutout when the set ambient temperature has been reached. Each panel controls a single fancoil. The control panel includes: Digital Display On/Off switch; speed fan operation selector Thermostat F/C; Summer/Winter operation switch.