XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Similar documents
Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

Description. Applications

CF1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Explosion-proof Immersion Heater Type D-8660

FE1 Explosion-Proof Electric Air Heaters

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Performance Data. curus Component Recognized; File No. E IP 20

Circulation Heaters Selection Guidelines

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

Product Catalog. Air and Space Heaters. Section C

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Dräger Polytron 5100 EC Detection of toxic gases and vapors

FX5 Series Explosion-Proof Electric Air Heaters

Dräger Polytron 8700 IR Detection of flammable gases and vapors

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Explosion-proof Duct Heaters

LMV Series W Low Profile - Medium Base

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

EJB Custom-Built Control Panels

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Circulation Heaters Selection Guidelines

Installation Instructions U-RAD-LT Electric Radiant Heaters

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Sinus Jevi (Explosion-Proof) Condens Heaters

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

EXH Series Explosionproof Electric Air Heaters

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

Application. Specifications. Finish

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

Cable Glands DB Series: Drain, Breather Valves and Unions

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

Tubular Industrial Process

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Specialty Products SPECIALTY PRODUCTS. Description. Camera Housing. VCB series Video Camera Housings 548. Specialty Products

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Comfort. Description. Applications

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

DMV Series W For Combustible Dusts

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

Dräger Polytron 5720 IR Detection of carbon dioxide

UL HAZARDOUS LOCATIONS SERVICES

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Overview of Hazardous Locations as They Relate to Solenoid Valves

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Applications. Standard Materials

CF1 ProVector Series. Installation, Operation, & Maintenance Instructions. Electric Convection Air Heaters for Hazardous Locations

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

CR 027 PTC Fan Heater W

How Limit Switches Can Stop Machines from Going Boom

INSTRUCTION MANUAL (ATEX / IECEx)

HLA Series Hazardous Location Fan Forced Unit Heater

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

EVLPF Series Compact Fluorescent

zonex enclosures hazardous locations

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

OPERATING INSTRUCTIONS. HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE Watt COD. EHSAFE20

Brasch Hazardous Location Unit Heaters

INTRINSICALLY SAFE LIGHTING RANGE

CU-MS & AH-HW Mini-Split Series

Refer to page 9 for information regarding the Breeze TM AccuSpec Sizing and Selection Program

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

INSTRUCTION & SERVICE MANUAL

CR1 Series Triton Corrosion Resistant Washdown Heaters

Hazardous Area Portable Fan Heater The Bulldog

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Dräger Polytron 8720 IR Detection of carbon dioxide

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

ULTRA-SAFE Explosion-proof Duct Heaters

S1L Series: Metal Bottom

Transcription:

The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals. All units can be fitted with an externally adjustable thermostat. With the, you get a safe and reliable heater with a handsome appearance and state-of-the-art design. Applications Typical applications for the include: control cabinets and small enclosures storage rooms for paints and cleaners grain elevators flour mills spray booths gas plants pump houses marine and offshore oil platforms cleaning and dyeing plants Selection of Refer to the atmospheric condition table (TABLE 2) at the beginning of this catalog for detailed selection data for the temperature code. To minimize cost and physical size of the heater, select the heater with the highest temperature code that suits the environment. In TABLE 8 and TABLE 9 a check mark (3) under the temperature code indicates that the surface temperature of the heater will not exceed the coded value listed in the atmospheric conditions table (TABLE 2) at the beginning of this catalog. Construction and Installation The XP and the explosionproof convection heaters utilize CCI Thermal s unique copper free aluminum extruded convector and patented x-max terminal housing. Large convector surface area and high mass fins ensure safe and efficient low temperature heat transfer to the environment. Convectors are black anodized to resist oxidation and maximize heat transfer. Convection Heater The x-max housing can be equipped with multiple tapped conduit entries throughout its length to facilitate installation. A track and trolley system and threaded covers at each end allow easy access to internal components. All units, except the single heat sink units, have a built-in terminal block for simplified electrical connection. The units are intended for wall or floor mounting with the heater positioned vertically as shown. Dual purpose brackets for floor or wall mounting and wire guards are supplied as standard. Special Wattage and s The following table lists the maximum design wattages for the four standard heat sink lengths and configurations. If standard units listed in TABLE 8 and TABLE 9 do not suit your application, a special unit based on TABLE 10 can be supplied (check factory).

7.25 (184 mm) 16.125 (410 mm) 25 (635 mm) 33.875 (860 mm) L Figure 6 Single Unit (1) Figure 7 Double Unit (2) Figure 8 Triple Unit (3) Figure 9 Quadruple Unit (4) 8 (205 mm) 8 (205 mm) Heat Sinc Heat Sinc 3.8125 (97 mm) or 1.25 (32 mm) Thermostat well with sensing bulb 3.5 (89 mm) Figure 10 Side View Floor Mounting Figure 11 Side View Wall Mounting Note: All units are shown with optional thermostat kit installed. Watts TABLE 8 - Explosion-Proof - Standard Heaters Standard Voltages Part No. Class I Division 1, 2 120 208 240 480 600 L Group A, B, C & D Dimension Weight Class II Division 1, 2 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø Group E, F & G Class III Division 1 Class I Division 1 Group A, B, C & D 475 3 3 3 10.0 (254) 3 10 (4.5) 1-1047T2D 750 3 3 3 16.7 (424) 3 15 (6.8) 1-3075T2D 1000 3 3 3 3 3 23.4 (594) 3 20 (9.1) 1-4100T2D 1250 3 3 3 3 3 30.1 (765) 3 25 (11.3) 1-6125T2D 1500 3 3 3 3 3 3 16.7 (424) 3 30 (13.6) 2-3150T2D 2000 3 3 3 3 3 3 3 3 3 23.4 (594) 3 40 (18.1) 2-4200T2D 3000 3 3 3 3 3 3 3 3 3 23.4 (594) 3 60 (27.2) 3-4300T2D 3750 3 3 3 3 3 3 3 3 3 30.1 (765) 3 75 (34.0) 3-6375T2D 4500 3 3 3 3 3 3 3 3 30.1 (765) 3 100 (45.4) 4-6450T2D CCI Thermal Technologies Inc.

Watts TABLE 9 - Explosion-Proof - Other Available Heaters Standard Voltages Part No. Class I Division 1, 2 120 208 240 480 600 L Class I Group A, B, C & D Dimension Weight Division 1 Class II Division 1, 2 Group 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø Group E, F & G A, B, C & D Class III Division 1 50 3 10.0 (254) 3 3 3 3 10 (4.5) 1-1005T6 100 3 10.0 (254) 3 3 3 10 (4.5) 1-1010T4A 175 3 10.0 (254) 3 3 3 10 (4.5) 1-1017T4A 200 3 3 3 30.1 (765) 3 3 3 3 25 (11.3) 1-6020T6 300 3 10.0 (254) 3 3 10 (4.5) 1-1030T3B 400 3 3 3 3 3 30.1 (765) 3 3 3 3 50 (22.7) 2-6040T6 450 3 3 3 3 3 30.1 (765) 3 3 3 25 (11.3) 1-6045T4A 475 3 3 3 16.7 (424) 3 3 15 (6.8) 1-3047T3B 600 3 3 3 3 3 30.1 (765) 3 3 3 3 75 (34.0) 3-6060T6 750 3 10.0 (254) 3 20 (9.1) 2-1075T2D 800 3 3 3 3 3 30.1 (765) 3 3 3 3 100 (45.4) 4-6080T6 850 3 3 3 3 3 30.1 (765) 3 3 3 50 (22.7) 2-6085T4A 1000 3 10.0 (254) 3 30 (13.6) 3-1100T2D 1000 3 3 3 3 3 23.4 (594) 3 3 40 (18.1) 2-4100T3B 1000 3 3 3 3 3 3 16.7 (424) 3 3 45 (20.4) 3-3100T3B 1250 3 3 3 3 3 3 3 3 3 30.1 (765) 3 3 3 75 (34.0) 3-6125T4A 1250 3 10.0 (254) 3 30 (13.6) 3-1125T2D 1350 3 3 3 3 3 3 30.1 (765) 3 25 (11.3) 1-6135T2D 1500 3 10.0 (254) 3 40 (18.1) 4-1150T2D 1500 3 3 3 3 3 3 3 23.4 (594) 3 3 60 (27.2) 3-4150T3B 1500 3 3 3 3 3 3 3 3 3 30.1 (765) 3 3 50 (22.7) 2-6150T3B 1600 3 3 3 3 3 3 3 3 30.1 (765) 3 3 3 100 (45.4) 4-6160T4A 2000 3 3 3 3 3 16.7 (424) 3 45 (20.4) 3-3200T2D 2250 3 3 3 3 3 23.4 (594) 3 3 80 (36.3) 4-4225T3B 2250 3 3 3 3 3 3 3 3 3 30.1 (765) 3 3 75 (34.0) 3-6225T3B 2500 3 3 3 3 3 3 3 3 16.7 (424) 3 60 (27.2) 4-3250T2D 2500 3 3 3 3 3 3 3 3 3 30.1 (765) 3 50 (22.7) 2-6250T2D 3000 3 3 3 3 3 3 3 3 3 30.1 (765) 3 3 100 (45.4) 4-6300T3B 3750 3 3 3 3 3 3 3 3 3 23.4 (594) 3 80 (36.3) 4-4375T2D 5000 3 3 3 3 3 3 3 3 30.1 (765) 3 100 (45.4) 4-6500T2D

TABLE 10 - Maximum Heater Wattages Heat Sink 5 (130 mm) 12 (300 mm) 19 (470 mm) 25 (640 mm) Type 1 475 300 190 95 2 938 3 1314 4 1524 1 783 498 294 142 2 1520 988 570 266 3 2173 4 2608 1 1021 684 380 209 2 2033 1282 722 342 3 3049 1881 1026 456 4 3780 1 1353 831 451 237 2 2688 1615 864 408 3 4018 2308 1254 612 4 5130 3230 1653 836 Thermostats CCI Thermal offers a wide variety of explosion-proof thermostats to suit most every need. All series heaters can be fitted with integral line voltage thermostats which are available either externally adjustable or tamper-proof; factory installed or as field installed kit. Remote thermostat mounting is also available. Refer to page 23 of this catalog when selecting the appropriate thermostat for the desired application. Accessories Wire Guards and Baffles All units are equipped with wire guards. Gull wing shaped bright aluminum rear baffles are standard with units rated for T2D temperature code (shipped separately). Model Coding 3-4300 T2D 31 T heater model HEAT SINK QUANTITY heat Sinc length 1 = 130 mm 3 = 300 mm 4 = 470 mm 6 = 640 mm WATTAGE x 10 Temperature code T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C) Heater Voltage 1 = 120V 2 = 208V 3 = 240V 7 = 480V 8 = 600V phase 1 = 1-Phase 3 = 3-Phase OPTIONS T = Thermostat R = Moisture-Resistant Design CE = ATEX Approved G = Gost Approved M = Special Mechanical E = Special Electrical Note: This nomenclature illustration is intended primarily to explain how a product part number is defined. Not all wattage, size and temperature code combinations are available please consult TABLE 9 on page 16 for availability. CCI Thermal Technologies Inc.

CE / ATEX Explosion-Proof Convection Heater Standard Features Suitable for the following hazardous location classification: EX II 2G Ex d IIC T3 or T4 Gb ITS 05ATEX13473 (See TABLE 11) universal support leg for wall or floor mounting high surface area black anodized heat emitter with integral tubular heating elements patented x-max housing with slide out terminal block trolley simplifies installation and servicing nickel plated wire guards on all models Watts Reference Figure (Page 15) TABLE 11 - CE/ATEX Explosion-Proof Convection Heater Specifications for T3 and T4 Units - Hazardous Location Rating Volts Phase L Dim. Approx. Weight Cataloge 399 Figure 6 110 1 1-3040T3B T3 475 Figure 6 120 1 1-3047T3B T3 399 Figure 6 220 1 16.7 (424) 15 (6.8) 1-3040T3B T3 436 Figure 6 230 1 1-3043T3B T3 475 Figure 6 240 1 1-3047T3B T3 840 Figure 7 110 1 2-4084T3B T3 1000 Figure 7 120 1 2-4100T3B T3 840 Figure 7 220 1 23.4 (594) 40 (18.1) 2-4084T3B T3 918 Figure 7 230 1 2-4092T3B T3 1000 Figure 7 240 1 2-4100T3B T3 1260 Figure 8 110 1 3-4126T3B T3 1500 Figure 8 120 1 3-4150T3B T3 1260 Figure 8 220 1 23.4 (594) 60 (27.2) 3-4126T3B T3 1378 Figure 8 230 1 3-4138T3B T3 1500 Figure 8 240 1 3-4150T3B T3 714 Figure 7 220 1 2-6071T4B T4 781 Figure 7 230 1 30.1 (765) 50 (22.7) 2-6078T4B T4 850 Figure 7 240 1 2-6085T4B T4 1891 Figure 8 220 1 3-6189T3B T3 2066 Figure 8 230 1 30.1 (765) 75 (34.0) 3-6207T3B T3 2250 Figure 8 240 1 3-6225T3B T3 2101 Figure 8 220 1 3-4210T3B T3 2296 Figure 8 230 1 23.4 (594) 60 (27.2) 3-4230T3B T3 2500 Figure 8 240 1 3-4250T3B T3 2521 Figure 8 220 1 3-6252T3B T3 2755 Figure 8 230 1 30.1 (765) 75 (34.0) 3-6276T3B T3 3000 Figure 8 240 1 3-6300T3B T3 1260 Figure 8 380 3 3-4126T3B T3 1378 Figure 8 400 3 23.4 (594) 60 (27.2) 3-4138T3B T3 1500 Figure 8 415 3 3-4150T3B T3 1891 Figure 8 380 3 3-6189T3B T3 2066 Figure 8 400 3 30.1 (765) 75 (34.0) 3-6207T3B T3 2250 Figure 8 415 3 3-6225T3B T3 2101 Figure 8 380 3 3-4210T3B T3 2296 Figure 8 400 3 23.4 (594) 60 (27.2) 3-4230T3B T3 2500 Figure 8 415 3 3-4250T3B T3 2521 Figure 8 380 3 3-6252T3B T3 2755 Figure 8 400 3 30.1 (765) 75 (34.0) 3-6276T3B T3 3000 Figure 8 415 3 3-6300T3B T3 No. T-Class