ASA linear smoke detector

Similar documents
FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Input module, input/output modules

Multi line separator module

Input module, input/output module

FDOOT241-9, FDOOT241-A, FDO241, FDT241

OH720, OP720, HI720, HI722

Output module (230 V)

FDL241-9 Linear smoke detector Mounting Commissioning

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

FDOOT221, FDO221, FDT221

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Mimic display driver, LED ribbon cable

FDCIO223 (ES 45) Transponder

FDOOT241-A9-Ex Multisensor fire detector

FDCL221-M Multi line separator module

FDCL221-Ex Line adapter (Ex)

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

OOH740, OOHC740 Automatic fire detectors

DT1101A / DT1102A / DO110xA Automatic fire detectors

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDL241-9 Linear smoke detector Technical Manual

OOH740-A9-Ex Multisensor fire detector

SWING radio fire detection system

DM1131 / DM1133 / DM1134 Manual call points

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

OOH740-A9-Ex Multi-sensor fire detector

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

DF1101-Ex Infrared flame detector

Fire control panels FC360

FDBZ290 Air sampling smoke detection kit

Test units and accessories

FDBZ290 Air sampling smoke detection kit

Test units and accessories

DC1192 Input /Output module

Fire control panels FC726 FC726-XA

Radio fire detection system

FC2040. Fire control panel. Sinteso. FS20 series, MP6

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

Fire control panel for modernization

FC724 Fire control panel

DF1151-Ex Infrared flame detector

FDCW241 Radio gateway Mounting

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Test units and accessories

FC722 Fire control panel

FC724 Fire control panel

FC722 Fire control panel

FC2020 Fire control panel

Synova TM product catalog.

DOW1171 / DCW1151 Radio fire detection system

FDCL221 Line separator

FC723 Fire control panel

FD20 Sinteso Detector system

XC10 Extinguishing control panels

FT2080 Fire terminal (Touch) Mounting Installation

Sinteso TM product catalog.

OH110, OP110, HI110 Automatic fire detectors

FP120-Z1 Power supply kit A (70 W) Technical Manual

FT2080 Fire terminal (Touch) Mounting Installation

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Room thermostat with 24-hour time switch and large LCD

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

FDBZ290 Air sampling smoke detection kit Technical Manual

FDA241, FDA221 Siemens ASD

FDCI221, FDCIO221 Input module, input/output module Technical Manual

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Electronic timeswitch

FDM273 Radio manual call point Mounting

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FDOOT241-A9-Ex Automatic fire detector Technical Manual

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

FDS229 Alarm sounder with supplementary optical indication Technical Manual

Call stations and extensions

Fireray 2000 Linear Smoke Detector

FS20 Fire detection system

XC10 combined fire detection and extinguishing control

XC10 combined fire detection and extinguishing control

Cerberus FIT conventional system

Frost Protection Thermostat

Room thermostats with LCD RDD100..

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

Fire & Security Products. Siemens Building Technologies Group

FDA241, FDA221 Aspirating Smoke Detector Technical Manual

Frost Units for air temperature monitoring

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Flush-mounted room thermostat

Duct Temperature Sensors

Line Smoke Detector LRMX

FDA241, FDA221 Siemens ASD

FDOOT221, FDOOT241-A3, FDOOT241-A4, FDOOT241-8, FDOOT241-9, FDOOT241-A9, FDO241, FDO221, FDT241, FDT221 Automatic fire detectors Technical Manual

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Fire safety products and accessories siemens.com/cerberus

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Transcription:

Sinteso / Cerberus PRO ASA linear smoke detector FDL241-9 Linear smoke detector, used addressed or collectively, ASAtechnology TM Reliable smoke detection in large spaces (indoor application) Detection distance 5...100 m Signal processing with ASAtechnology Works according to the principle of light attenuation by smoke Microprocessor-controlled signal processing Automatic compensation for soiling High immunity to extraneous light and electromagnetic interference Transmitter and receiver in one housing Distance measurement between transmitter and receiver Communication via FDnet/C-NET (individually addressed) or collective detector line (switchover) 2017-09-25 Control Products and Systems

Properties Features Integrated line separator: The section of the detector line affected by the short-circuit is located by the fire control panel and isolated between two FDnet/C-NET devices. The detector and base housing is made from hard-wearing glass-fiber-reinforced plastic. Protected electronics Built-in alarm indicator Self test function Detector heating unit in case of danger of moisture condensation 3 sensitivity levels and event-driven detection behavior Addressed signal processing: Transmission of 4 danger levels to the control panel: Enables activation of differentiated measures and an early warning in the case of incorrect applications 4 functional states: As well as the normal state, the detector transmits a notice, an impairment, or a fault (depending on the significance of the cause of the problem). Collective signal processing: The detector transmits alarm states and fault states to the control panel. Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated 2

Functions The linear smoke detector smoke detector consists of a transmitter and a receiver and works according to the principle of light attenuation by smoke. The transmitter transmits to the reflector a highly focused infrared ray. If no smoke is present, a large part of the infrared ray reaches the reflector and is returned to the receiver. The incoming light generates an electric signal on the receiver's photo diode. Smoke entering the measuring section weakens the infrared ray. If the signal reaches specific measured values, the detector transmits the corresponding danger level to the control panel. Distance measurement to detect foreign bodies The alarm state is signaled locally with the built-in alarm indicator. 1 2 3 max. 5...100 m 1 Detector / receiver 3 Detector / transmitter 2 Reflector Environmental influences Digital signal compensation: Slow changes to the received infrared signal as a consequence of dusty lenses or other environmental influences are automatically compensated by the detector. Multiple-coincidence circuit: Suppresses electrical and optical fault signals. In the case of an extremely strong incidence of extraneous light, the extraneous light filter DLF1191-AC is used in addition. Prism-shaped reflectors: Incident rays of light are reflected in parallel. The detector is not affected by mounting surface vibration phenomena. Fields of application Large warehouse spaces and production halls Rooms with complex ceiling structures or ceilings that are of value in terms of art history Covered courtyards Atrium buildings Entrance halls 3

Accessories DLR1191 reflector for long distance (prism) For reflecting the infrared ray of the linear smoke detector Prism-shaped reflector Reflection distance: 20 100 m With a built-in heating unit DLR1192 reflector for middle distance (foil) For reflecting the infrared ray of the linear smoke detector Micro-prismatic film Reflection distance: 30 65 m Dimensions: 200 x 200 x 2.5 mm Hole diameter: 4 mm DLR1193 reflector for short distance (foil) For reflecting the infrared ray of the linear smoke detector Micro-prismatic film Reflection distance: 10 30 m Dimensions: 100 x 100 x 2.5 mm Hole diameter: 4 mm DLH1191A detector heating unit For applications where there is danger of moisture condensation or icing Incl. terminal block for the connection DLF1191-AA short distance filter (7 10 m) DLF1191-AB short distance filter (5 8 m) DLF1191-AC extraneous light filter For toning down the infrared ray over short distances Distance: 7 10 m For toning down the infrared ray over short distances Distance: 5 8 m For filtering extraneous light during a high level of extraneous light FDLU291 adjustment kit for linear smoke detector For commissioning the linear smoke detector Scope of delivery: Adjustment device, alarm test filter, visor, magnet, spiral cable, MC link cable, 9 V battery, suspension fixture with cable gripper and chain, case 4

Type Overview Linear smoke detector FDL241-9 Type Designation Order number Weight [kg] FDL241-9 Linear smoke detector A5Q00002298 0.440 Accessories for linear smoke detector FDL241-9 Type Designation Order number Weight [kg] FDLB291 Base for linear smoke detector A5Q00003941 0.305 Metal cable gland M20 x 1.5 A5Q00004478 0.036 DLF1191-AA Short distance filter (7 10 m) BPZ:4933030001 0.005 DLF1191-AB Short distance filter (5 8 m) BPZ:4933160001 0.005 DLF1191-AC Extraneous light filter BPZ:5221480001 0.005 DLH1191A Detector heating unit BPZ:4787970001 0.010 DLR1191 Reflector for long distance (prism) BPZ:4787710001 0.510 DLR1192 Reflector for middle distance (foil) BPZ:4788490001 0.075 DLR1193 Reflector for short distance (foil) BPZ:4787840001 0.025 FDLU291 RE10 Adjustment kit for linear smoke detector Detector tester for linear smoke detectors A5Q00004905 0.840 BPZ:3685190001 0.345 TF04 Alarm test filter (absorption 77 %) BPZ:4931090001 0.005 Product documentation Document ID Name 007016 Technical manual for linear smoke detector FDL241-9 008164 Sinteso detector system FD20 equipment overview 008331 List of compatibility (for 'Sinteso ' product line) A6V10225323 A6V10229261 A6V10332811 Cerberus PRO detector system FD720 equipment overview List of compatibility (for 'Cerberus PRO' product line) Mounting/commissioning of linear smoke detector FDL241-9 Related documents such as the environmental declarations, CE declarations, etc., can be downloaded from the following Internet address: http://siemens.com/bt/download 5

Notes Mounting Mounting options Easy mounting of the housing on stable surfaces. Wood and steel girder constructions are usually unsuited, as temperature and humidity fluctuations, wind or snow pressure can affect them. 6 openings for M20 metal cable gland External alarm indicator can be connected Between the detector and the reflector there must be an uninterrupted and clear line of sight. Obfuscation of sight caused by operational generation of dust, vapor or smoke may decisively impair the system. The monitoring ray must not be interrupted by moving objects, e.g., overhead cranes, ladders, transportable objects, cobwebs, etc. The adjustment kit FDLU291 provides an effective means of aligning the lens with the reflector single-handedly. Corresponding reflectors are available for different distances. Disposal For disposal purposes, the device is considered as waste electrical and electronic equipment within the meaning of European Directive 2012/19/EU and must not be disposed of as household waste. Use the appropriate channels for disposing of the device. Local and currently valid legislation must be observed. 6

Technical data Linear smoke detector FDL241-9 Operating voltage addressed / collective Operating current (quiet) addressed / collective Number of external alarm indicators that can be connected Detection distance DC 12 33 V / DC 14 28 V 0.8 ma / 0.7 ma 2 5 100 m Operating temperature -25 +60 C Storage temperature -30 +75 C Air humidity (no moisture condensation) Communication protocol Conductor cross section Color Protection category (IEC 60529) 95 % rel. FDnet/C-NET or collective (with and without current limitation) 0.2 1.5 mm² ~RAL 9010 pure white Standards EN 54-12, EN 54-17, EN 62471 Approvals VdS LPCB FM System compatibility FDnet C-NET Collective system compatibility IP65 G204063 126bd/02 3029351 FS20, AlgoRex, SIGMASYS FS720, FC360 CZ10, BC10, FC10, XC10, CS11, FC700A, FC330A, SIGMASYS, BMS, SM80/88/D100 Detector heating unit DLH1191A Operating voltage Operating current (quiescent) Resistance DC 20 33 V 30 50 ma 600 07 0786 FDL241-9 Siemens Switzerland Ltd; Gubelstrasse 22 CH-6301 Zug Technical data: see doc. 007016 FDL241-9 - Linear optical smoke detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-12 / EN54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20014; DoC No.: CED-FDL241-9 7

Dimensional drawings ASA linear smoke detector FDL241-9 with base FDLB291 135 M20 x 1.5 153 135 115 4.5 Reflector for long distance (prism) DLR1191 with base FDLB291 135 M20 x 1.5 153 135 45 65 4.5 Reflector for short distance (foil) DLR1193/ Reflector for middle distance (foil) DLR1192 2.5 100/200 4.0 100/200 Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2007 Technical specifications and availability subject to change without notice. 8 Document ID FD20/FD720 manual Edition 2017-09-25 Register 3/3