ELECTRICAL QUANTITY WEIGHT (LB)

Similar documents
Engineering Data Book

Architecture - Engineering - Planning

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons


FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

C13-Series Engineering Guide

4-Way Cassette type. Contents MMU-AP 2H2UL

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Multi-Path RTU-TYPE 2

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

VertiCool Aurora Engineering Guide

Commercial High-Efficiency Condensing Units

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50TM TFF COMBINATION HEATING/COOLING UNITS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

technical guide Water-Cooled Self-Contained Units

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Commercial High-Efficiency Condensing Units

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Advance Release September 2009

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

50TM COMBINATION HEATING/COOLING UNITS

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]


Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

DESIGN MANUAL R410A. Indoor Unit. Outdoor Unit FILE NO. A Cooling Only Model <Inverter Unit> Heat Pump Model <Inverter Unit>

Concealed Ducted Split Series R-407C MBH

PAJ3. Product Specifications

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Water-Cooled Self-Contained Units

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Launch SHRMi

PAR5. Product Specifications

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Unit Features & Benefits RQPM/RQRM Series

Product Data INDUSTRY LEADING FEATURES / BENEFITS

TECHNICAL SPECIFICATIONS

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

Air to Air Heat Exchanger

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Roof Top Packaged Unit (RTU-1) Specification

Index. Toshiba Solutions. Absolute comfort

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

DESIGN MANUAL R410A. Outdoor Unit. FS unit FILE NO. A RBM-Y1122FE RBM-Y1802FE RBM-Y2802FE

NFZP Variable Refrigerant Flow Guide Specification

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

PACKAGE AIR CONDITIONER

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Submittal Data Performance Data Electrical Data

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Single Fan MiNi VRF Apartment Ready

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

Corp L2 Revised

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Engineering. Super Heat Recovery Multi System

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Transcription:

VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø / HZ RLA MOCP (LB) MODEL DB WB WB (CFM) LOW (db) REMARKS FCU-6 MMU-AP0362H2UL 4-Way Cassette Zone 6 74.2 62.2 73.4 31.71 23.87 14.10 1160 37 208/1/60 1.0 15 59 1, 2, 3, 4, 5, 7, 8 VRF-1 FCU-7 MMU-AP0302H2UL 4-Way Cassette Zone 7 74.1 62.2 73.2 24.06 17.48 9.80 730 34 208/1/60 0.8 15 48 1, 2, 3, 4, 5, 7, 8 FCU-8 MMU-AP0242H2UL 4-Way Cassette Zone 8 73.9 62.1 70.0 20.11 13.52 2.91 670 31 208/1/60 0.8 15 48 1, 2, 3, 4, 5, 7, 8 FCU-9 MMU-AP0121MH2UL Compact 4-Way Cassette Zone 9 73.9 62.2 70.0 9.91 7.09 1.64 330 32 208/1/60 0.4 15 35 1, 2, 3, 4, 5, 7, 8 FCU-10 MMD-AP0094BH2UL Medium Static Ducted Zone 10 73.9 62.2 70.0 7.09 5.40 1.18 312 28 208/1/60 0.8 15 64 1, 2, 3, 4, 5, 7, 8, 10 VRF-2 FCU-11 MMD-AP0184BH2UL Medium Static Ducted Zone 11 74.1 62.2 70.6 15.15 12.00 3.08 635 29 208/1/60 0.9 15 93 1, 2, 3, 4, 5, 7, 8, 10 FCU-12 MMD-AP0184BH2UL Medium Static Ducted Zone 12 73.9 62.2 70.0 14.78 10.39 2.36 635 29 208/1/60 0.9 15 93 1, 2, 3, 4, 5, 7, 8, 10 FCU-13 MMU-AP0181MH2UL Compact 4-Way Cassette Zone 13 73.9 62.2 70.0 15.95 11.24 2.56 450 36 208/1/60 0.5 15 35 1, 2, 3, 4, 5, 7, 8 FCU-14 MMD-AP0724H2UL High Static Ducted Zone 14 74.8 62.4 74.7 49.57 45.86 34.73 2470 47 208/1/60 7.1 15 353 1, 2, 3, 4, 5, 7, 8, 10 FCU-15 MMU-AP0212H2UL 4-Way Cassette Zone 15 74.6 62.4 74.5 15.43 15.39 14.63 670 31 208/1/60 0.8 15 48 1, 2, 3, 4, 5, 7, 8 VRF-3 FCU-16 MMU-AP0181MH2UL Compact 4-Way Cassette Zone 16 74.1 62.2 73.5 16.40 11.70 8.38 450 36 208/1/60 0.5 15 35 1, 2, 3, 4, 5, 7, 8 FCU-17 MMU-AP0182H2UL 4-Way Cassette Zone 17 74.1 62.2 73.6 16.94 12.24 8.91 550 31 208/1/60 0.6 15 46 1, 2, 3, 4, 5, 7, 8 FCU-18 MMD-AP0364BH2UL Medium Static Ducted Zone 18 74.3 62.3 74.2 28.40 23.36 21.67 1088 35 208/1/60 1.8 15 119 1, 2, 3, 4, 5, 7, 8, 10 FCU-19 MMU-AP0212H2UL 4-Way Cassette Zone 19 74.9 62.5 70.5 14.64 14.02 0.58 670 31 208/1/60 0.8 15 48 1, 2, 3, 4, 5, 7, 8 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. PROVIDE VRF DIRECT-EXPANSION INDOOR UNIT WITH DC INVERTER DRIVEN FAN MOTOR, PIPING CONNECTORS, PULSE MODULATING VALVE (METERING DEVICE), INTEGRAL LEAVING/RETURN TEMPERATURE SENSORS, AND HANGING BRACKETS. UNIT SHALL BE PROVIDED WITH FACTORY INSTALLED RETURN AIR TEMPERATURE SENSOR. PROVIDE INTERNAL CONTROL SYSTEM WHICH EMPLOYS AN ALGORITHM FOR TEMPERATURE CONTROL TO AN ACCURACY OF 0.9 F. PROVIDE METERING DEVICE THAT SHUTS OFF COMPLETELY WHEN THE ZONE IS SATISFIED. PROVIDE WIRED ZONE CONTROLLER RBC-AMS51E-ES. PROVIDE WIRED REMOTE SENSOR TCB-TC21LUL. PROVIDE CONDENSATE LIFT AND OVERFLOW SAFETY SWITCH. PROVIDE FACTORY SUPPLIED BRANCHING KITS CONSISTING OF EITHER Y JOINTS AND/OR HEADERS TO ENSURE EVEN REFRIGERANT FLOW. INSULATE UNITS WITH 1" RUBATEX SHEET USING AN ADHESIVE. KEEP ALL UNITS SCREWS ACCESSIBLE FOR UNIT MAINTENCE. PROVIDE AUXILLARY DRAIN PAN UNDER UNIT AND FLOAT SWITCH. DRAIN PAN SHOULD BE A MINIMUM OF 3" LARGER THAN UNIT ON ALL SIDES. TOSHIBA-CARRIER VRF HEAT PUMP - OUTDOOR EQUIPMENT SCHEDULE MARK OUTDOOR UNIT CAPACITY QUANTITY MIN # OF NOMINAL COOLING NOMINAL HEATING ELECTRICAL POSITION SYSTEM NAME MODEL MANUFACTURER RANK OUTDOOR INDOOR IEER COMPRESSORS CAPACITY (BTUH) CAPACITY (BTUH) V / Ø / Hz RLA MOCP WEIGHT (LB) REMARKS VRF-1 VRF Condensing Unit 1 MMY-AP0724HT6UL TOSHIBA-CARRIER 6 TON 1 3 11.2 2 72,000 81,000 CENTER 460/3/60 6.7 20 621 1, 2, 3, 4, 5, 6, 7, 8, 10 VRF-2 VRF Condensing Unit 2 MMY-AP0724HT6UL TOSHIBA-CARRIER 6 TON 1 5 12.2 2 72,000 81,000 CENTER 460/3/60 6.7 20 621 1, 2, 3, 4, 5, 6, 7, 8, 10 VRF-3 VRF Condensing Unit 3 MMY-AP1684HT6UL TOSHIBA-CARRIER 14 TON 2 6 11.2 6 168,000 189,000 CENTER 460/3/60 8.8 / 6.7 25 / 20 817 / 621 1, 2, 3, 4, 5, 6, 7, 8, 10 NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. OUTDOOR TEMPERATURE COOLING/HEATING 95 F / 43 F. SCHEDULED EFFICIENCIES ARE MINIMUM REQUIRED. PROVIDE INVERTER DRIVEN TWIN ROTARY COMPRESSOR CAPABLE OF FULL RANGE OF CONTROL TO A LEVEL OF 0.1 HZ. ALL COMPRESSORS SHALL BE OF THE SAME TYPE. PROVIDE DIRECT DRIVE INVERTER DRIVEN OUTDOOR FAN MOTOR. PROVIDE 4 SIDED OUTDOOR COIL WITH FACTORY APPLIED CORROSION RESISTANT FINISH. PROVIDE FACTORY MOUNTED COMPRESSOR SOUND BLANKETS, CRANKCASE HEATERS, OVER-TEMPERATURE OPERATION PROTECTION, HIGH/LOW PRESSURE SWITCHES, AND INVERTER OVERLOAD PROTECTOR. PROVIDE FUSES, FUSIBLE PLUG, OVER CURRENT RELAY FOR COMPRESSORS, THERMAL PROTECTORS FOR COMPRESSOR AND FAN MOTOR, COMPRESSOR TIME DELAY, OIL RECOVERY SYSTEM, OIL LEVEL SENSOR, OVER-CURRENT SENSOR, COMPRESSOR SUCTION AND DISCHARGE TEMPERATURE AND PRESSURE SENSOR. PROVIDE AN OIL MANAGEMENT SYSTEM THAT BALANCES OIL BETWEEN COMPRESSORS WITHIN A MODULE, REPLENISHES OIL FROM THE OIL SEPARATOR, AND ALLOWS MOVING OIL AND REFRIGERANT BETWEEN TWINNED UNITS, EVEN IF ONE OF THE UNITS IS NOT RUNNING. PROVIDE CENTRAL WEB BROWSER CONTROL SYSTEM BMS-SM1280HTLUL. TOSHIBA-CARRIER VRF - INDOOR EQUIPMENT SCHEDULE FOR COMPLETE ACCURATE WIRING AND PIPING DIAGRAM, ENGINEERING SUPPORT, AND SALES ASSISTANCE CONTACT TOSHIBA-CARRIER, CHRIS SMELLEY, AT 713-939-6001. 1A 1B 1C 1D 2 3 4 5A 5B 5C 6A 6B 6C 7 8 9 10 11 12 13 15 16 17 18 19 20 21 22 23 R N-0 20-3 -0-E B0 9-1 6A: UAD E-U 0F-D RF- D0A -DH FAH YF - 00-0 0C0 000 AB Tag: OAU-1 5000 CFM with Wheel Job Information Job Name: Job Number: Site Altitude: Refrigerant Static Pressure External: Evaporator: Filters Clean: Dirt Allowance Re-Heat Coil Cooling Section NRG Call Center Job #1253 0 ft R-410A 1.00 in. wg. 0.25 in. wg. 0.09 in. wg. 0.35 in. wg. 0.03 in. wg. Unit Information Approx. Op./Ship Weights: Supply CFM/ESP: Final Filter FV / Qty: Exhaust CFM/ESP/TSP: Outside CFM: Ambient Temperature: Economizer: Heating: Cabinet: Heatwheel: Total: Heating Section 3544 / 3544 lbs. (±5%) 5000 / 1 in. wg. 240.00 fpm / 6 5000 / 0.25 / 1.49 in. wg. 5000 98 ºF DB / 80 ºF WB 0.11 in. wg. 0.11 in. wg. 0.05 in. wg. 0.95 in. wg. 2.93 in. wg. Equivalent Total Capacity: Gross Net 468.42 MBH 458.81 MBH PreHeat Type: Std (No Preheat) Total Capacity: Sensible Capacity: Latent Capacity: HW Total Cooling Capacity: Mixed Air Temp: Entering Air Temp: Lv Air Temp (Coil): Lv Air Temp (Unit) Digital Comp. Capacity Ratio: Supply Air Fan: SA Fan RPM / Width: Exhaust Air Fan: EA Fan RPM / Width: Evaporator Coil: Evaporator Face Velocity: Energy Recovery Wheel: Rating Information 237.51 227.90 MBH 153.77 144.16 MBH 83.74 MBH 230.91 MBH 82.41 ºF DB 69.18 ºF WB 82.41 ºF DB 69.18 ºF WB 53.39 ºF DB 53.19 ºF WB 55.15 ºF DB 53.92 ºF WB 100% 1 x 220 @ 3.38 BHP 1496 / 4.871" 1 x RM220A @ 1.99 BHP 1322 / 4.920" 19.9 ft² / 6 Rows / 12 FPI 251.7 fpm 1 x ERC-5262C Cooling Capacity (MBH): 238.0 Cooling EER: 12.3 Cooling IEER: 14.8 Rated in accordance with AHRI 340/360 Application EER @ Op. Conditions: 19.7 Electrical Data Rating: Unit FLA: 460/3/60 85 Heating Type: Heating CFM: Total Capacity: OA Temp: RA Temp: Entering Air Temp: Leaving Air Temp: Input: Heater Qty: Electric Heat FLA: Re-Heat Coil: Electric Heat 5000 204.8 MBH 27.0 ºF DB / 25.0 ºF WB 72.0 ºF DB / 60.0 ºF WB 57.5 ºF DB / 50.3 ºF WB 95.4 ºF DB / 64.7 ºF WB 60.0 kw 6 72.2 Capacity: 90 MBH LA DB / WB: 70.00 ºF / 59.68 ºF RH: 55% Minimum Circuit Amp: Maximum Overcurrent: Qty HP VAC Phase RPM FLA RLA Compressor 1: 1 460 3 16.7 Compressor 2: 1 460 3 16.7 Condenser Fans: 2 0.75 460 3 1080 1.8 Supply Fan: 1 5.00 460 3 1760 7.6 Exhaust Fan: 1 3.00 460 3 1760 4.8 Heatwheel: 1 0.1667 460 1 1770 0.6 88 100