EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Similar documents
5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

ALTAIR 5X Multigas Detector Product Specification

Monitores Personales. Personal Monitor

Equipment. Model R002. Description. SF6 leak detector

ALTAIR 5X Multigas Detector

GasAlertMicroClip X3 Specifications

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Model GX-2003 Operator s Manual

ALTAIR 5X Multigas Detector

Instruction Manual Eagle Series

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

RAE Systems Systems. User Presentation. October Protection Through Detection

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

VENTIS PRO SERIES. Product Guide

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

T.ex Single Gas Detector VISA

Using the QRAE Plus personal multigas monitor

INSTRUCTION MANUAL MODEL GX-82A

up to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Polytector III G999 for Ex zone 0

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

PRODUCT GUIDE. Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management MUNICIPAL SERVICES

Dräger X-am 7000 Multi-Gas Detection

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

MSA Portable Gas Detection

GX-2009 Portable Gas Monitor Operator s Manual

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Operate the Mutli-Gas Monitor PID

GX-2009 MSHA Certified Version CH 4 /O 2 /CO/H 2 S Portable Gas Monitor Operator s Manual

SENSIT PROPANE GAS. 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators ENERGY INDUSTRIES

For the Safety of Your

INSTRUCTION MANUAL MODEL GX-82A

GX-2009 Portable Gas Monitor Operator s Manual

Dräger X-am 7000 Multi-Gas Detection

Sieger Apex. Flexibility that meets your requirements

INNOVA Series INSTRUCTION MANUAL P/N REV. D

Model GX Operator s Manual

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

GX-2009 Portable Gas Monitor Operator s Manual

E1000 Portable gas detector

Toxic Gas Detection. Model F12. Toxic Gas Detection

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

SAFESITE Multi-Threat Detection System

SENSIT FIRE SERVICE. 4Hazardous Gas Monitors 4Gas Leak Detectors 4Calibration Stations 4Data Management EMERGENCY RESPONSE

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Model GX-2001 Canadian Version Operator s Manual Part Number: RK Revision: 0 Released: 1/17/05

An easy and flexible way to do gas detection.

Two-Channel Gas Controller

Innova Series Operator s Manual

INNOVA Series. Instruction Manual Part Number

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

IMR EX610. Portable Gas Detector. Operation Manual

IMR IX176 Portable Gas Detector User Manual

Model GX Operator s Manual

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

SC-01 Operator s Manual

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Choosing the best confined space gas detector

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Gas Detection For Life

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

Warranty Registration

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

incontrol Systems Inc. Flame and Gas Detection

G450. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Instruction Manual Model GX-86 Portable Four Gas Monitor

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Industrial Grade Gas Detection

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Xgard. Fixed detectors For flammable, toxic or oxygen gases

SENSIT GOLD G2 II 2 G INSTRUCTION MANUAL. Gas Detection Instrument. Read and understand instructions before use.

SP-220. Features. Combustible handheld gas leakage detector

ATX620. Instruction Manual. Multi-Gas Monitor. P/N REV 02 Printed Specifications Subject to Change GUARANTEED. FOR LIFE.

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Model D12. Digital Gas Transmitter

Safe Operation Manual. Honeywell IQ Force Gas Detector

M2A Transmitter Operator s Manual

T82. Instruction Manual. Single Gas Monitor GUARANTEED. FOR LIFE. P/N REV 0 PRINTED ,000 Specifications Subject to Change

SENSIT MUNICIPAL. 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators GOVERNMENT SERVICES

SENSIT GOLD G2 INSTRUCTION MANUAL For use with combustible gases and optionally available oxygen and toxic gases.

Dräger X-am 5000 Multi-Gas Detection

Bacharach Bodyguard 4 User's Guide

Portable Gas & Flame Detection Product Overview

G-TECTA TM. Portable Gas Detection Instruments

WATCHMAN MULTIGAS MONITOR

Sirius MultiGas Detector

X5 Personal Gas Detector. Operating Manual

Transcription:

EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective overlay 3 Display modes: Display all gases Single gas view large type-auto scroll Single gas view large type-manual scroll Powerful internal sample pump with 125 range Programmable gas channel positions 4 button operation with glow in the dark text 3 Operating modes: Normal operating Leak check Bar hole sampling Glove friendly handle and buttons Chemical, water, and dust resistant, RFI / EMI protected high impact case PID sensor for low ppm VOC detection Smart plug & play sensors for toxic gases PPM, % LEL, or % Vol. auto-ranging combustible detection Combine catalytic and IR sensors for combustible detection Methane elimination for environmental use Standard 4 Gas Channels Combustible O2 H2S CO 6 Channel Capacity Option 1 Option 2 Option 3 3 Specialty Channels PID (VOC) Toxics NH3, ASH3, HCN, PH3, SO2 Infrared (IR) CO2, CH4, HC Multi lingual (5 languages) Thermal Conductivity * Some combinations NOT compatible CH4, H2 Interchangeable Alkaline / NiMH removable battery compartment Battery compartment thumbscrew

Specifications Enclosure Weatherproof, chemical resistant, anti RFI / EMI coated high impact polycarbonate - PBT blend. Can operate in rain or be set into 2.0 of water without leakage. Ergonomically balanced with rugged top mounted handle. Dimensions 9.5 L x 5.25 W x 5.875 H (241mm L x 140mm W x 149mm H) Weight Detection Principle Sensor Life Sampling Method Display Language Alarms Alarm Method Controls Continuous Operation Power Source Operating Temp. & Humidity Response Time 3.8 Lbs (1.72kg) (standard 4 gas with batteries) Catalytic combustion, electrochemical, galvanic, infrared, photo ionization, and thermal conductivity. 2 Years under normal conditions. Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH Backlit 128 x 64 graphics display. Viewed through window in case top. Displays readings & status of all 6 channels simultaneously. Backlight, illuminates for alarms and on demand with adjustable time. Optional mode allows automatic or manual scrolling display of just one gas at a time with very large characters. Readout can display in 5 languages (English, French, German, Italian, or Spanish). 2 Alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable. Buzzer 95 db at 30 cm, four high intensity LED s. 4 External glove friendly push buttons for operation, demand zero, and autocalibration. Buttons also access LEL/ppm, % Vol. alarm silence, peak hold, TWA/STEL values, battery status, conversion factors, and many other features. At 70 F, (21 C) 16 hours using alkaline batteries, or 18 hours using Ni-MH. 4 Alkaline or Ni-MH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines). -4 F to 122 F (-20 C to 50 C) 0 to 95% RH, non-condensing. 30 Seconds to 90% of range (for most gases) using standard 5 ft hose. Intrinsically Safe, Class I, Division 1, Groups A, B, C, D. Safety Rating Approvals: Standard Accessories Optional Accessories Warranty Shoulder strap, alkaline batteries, hydrophobic probe, 5 foot hose, and internal hydrophobic filter Dilution fitting (50/50) Ni-MH batteries Battery charger, 115 VAC, 220 VAC, or 12 VDC (charge time 4 hours)/ continuous operation adapter, 115 VAC or 12 VDC Extension hoses Two year material and workmanship, one year for PID sensor Specifications subject to change without notice www.rkiinstruments.com 800 754-5165

Sensor Technologies Standard 4 Gas Specialty Sensors Smart Toxic Sensors Catalytic Photo ionization Detection (PID) Smart Electrochemical Hydrocarbons (CH 4, standard) 0-100% LEL 0-5% Vol. (CH 4 ) 0-50,000 ppm (CH 4 ) ± 5% of reading or ± 2% of full scale (*) ± 50 ppm or ± 5% of reading (*) Combustible level detection displayed in % LEL, PPM, or % volume. Methane is the standard configuration. Other combustible gases available. Galvanic Gas Volatile Organic Compound (VOC) Monitor low ppm VOC gases. Infrared Range 0-50 ppm 0-2,000 ppm Ammonia (NH 3 ) 0-75 ppm Arsine (AsH 3 ) Chlorine (Cl 2 ) Hydrogen Cyanide (HCN) Phosphine (PH 3 ) Sulfur Dioxide (SO 2 ) 0-1.5 ppm 0-3 ppm 0-15 ppm 0-1 ppm 0-6 ppm ± 10% of reading or ± 5% of full scale (*) Monitor a wide variety of toxic gases. Smart plug and play sensors are auto recognized and can be remotely calibrated. Oxygen (O 2 ) 0-40% Vol. ± 0.5% O 0-100% Vol. 2 A specific electrochemical sensor for oxygen monitoring. Carbon Dioxide (CO 2 ) Methane (CH 4 ) Hydrocarbons 0-10,000 ppm 0-5% Vol. 0-60% Vol. ± 5% of 0-100% LEL 0-100% Vol. 0-100% LEL 0-30% Vol. Monitor combustible gases in inert environments. Monitor wide range of CO 2. reading or ± 2% of full scale (*) Standard Electrochemical Thermal Conductivity Carbon Monoxide (CO) Hydrogen Sulfide (H 2 S) 0-500 ppm ± 5% of 0-100 ppm reading ± 2 ppm (*) Extra long-life CO and H 2 S sensors. Methane (CH 4 ) 0-100% Vol. ± 5% of reading Hydrogen (H 2 ) or ± 2% of 0-10% Vol. 0-100% Vol. full scale (*) Monitor % volume methane or hydrogen. Note: (*) = Whichever is greater 110620/5000

CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples up to 125 Maintain steady sample flow to sensors Audible and visual alarms 2 Ways to communicate with workers Ideal for refinery applications LEAK INVESTIGATION Provides ppm detection of combustible gas Barhole mode for tracking leak migration Leak check with changing blink / pulsing rate LED s and alarm tones increase in frequency as gas concentration increases Audible alarm silence Perform leak investigations without alarming residents LINE PURGE TESTING Thermal conductivity sensor 0 to 100% volume Methane / Hydrogen range Autoranging IR Automatically changes from % LEL to % Vol. Displays appropriate unit of measure VOC MONITORING Robust photo ionization detector (PID) Two ranges available, 0-50 ppm or 0-2,000 ppm Can be combined with other sensors to maximize capability Method 21 compliant TRANSFORMER TESTING Determine transformer health by sampling head space Measure Hydrogen (and other flammable gases) and Oxygen in nitrogen blanket Increasing flammable gas levels in head space indicates failing transformer LANDFILL MONITORING LEL / PPM and 0-100% volume Methane 0-60% Carbon Dioxide range Can be combined with other sensors (O2/H2S/CO) to maximize capability RKI Instruments, Inc.

Accessories B. A. Calibration station B. Battery charger / continuous operation adapter, AC and DC versions C. Variety of sample hose lengths D. Float probe, auto shut off when probe contacts water E. PID service kits C. D. AC DC F. Calibration kits E. G. Carrying cases H Rechargeable Ni-MH batteries G. A. F. Made in USA User Selectable Options Date and Time Date Format Battery Type Configuring Channels Combustible Gas Selection Catalytic Detection Units Relative Response On or Off Alarm Points Alarm Latching Alarm Silence User and Station ID Autocal Values Backlight Delay Auto Fresh Air Data Log Interval Data Log Overwrite Data Log Memory LCD Contrast Calibration Reminder Calibration Past Due Action Calibration Interval Leak Check / Bar Hole Mode Bar Hole Measurement Time Operation Confirmation Alert Password Function On or Off Factory Default Lunch Break Language Span Factor Authorized Distributor: Toll Free: (800) 754-5165 Phone: (510) 441-5656 Fax: (510) 441-5650 www.rkieagle2.com World Leader In Gas Detection & Sensor Technology