AIR HANDLING UNIT SCHEDULE AIR DEVICE SCHEDULE DESIGNATION MANUFACTURER MODEL NUMBER LOCATION ORIENTATION AHU-1 CARRIER 39LF10 2ND FL. MECH ROOM RIGHT HAND AREA SERVED COVERED WALKWAY EER @ ARI 9.7 OPERATING WEIGHT (LBS.) 796 LBS. UNIT SIZE (NOMINAL) 7.5 TONS FAN NOMINAL AIRFLOW (CFM) 4000 VENTILATION AIR (CFM) 350 POWER (HP) 5 RPM 1800 ESP (IN H2O) 3.23 NUMBER OF FANS 1 CHILLED WATER COOLING COIL EDB / EWB (F) 78.0 / 65.0 LDB / LWB (F) 57.38 / 55.73 NET SENSIBLE CAP. (MBH) 90.19 NET TOTAL CAP. (MBH) 113.09 FLOW RATE (GPM) 22.6 EWT, F 44.0 LWT, F 54.0 FACE VELOCITY (FPM) 503.1 ROWS / FINS PER INCH 4 / 11 HEATING COIL EAT / LAT ( F) 60.0 / 88.95 HEATING CAP. (MBH) 126.62 FLOW RATE (GPM) 12.7 EWT ( F) 180.0 LWT ( F) 160.0 FACE VELOCITY (FPM) 503.1 ROWS / FINS PER INCH 1 / 8 ELECTRICAL DATA VOLTS / PH / HZ 240/3/60 MCA 16.2 MOCP 25 NOTES: 1. AHU-1 SHALL BE EQUIPPED WITH FIELD MOUNTED SMOKE DETECTOR ARRANGED TO SHUT DOWN UNIT. SMOKE DETECTOR SHALL BE SUPPLIED AND INSTALLED BY THE MECHANICAL CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. 2. PROVIDE MANUAL VOLUME DAMPER FOR OUTSIDE AIR CONNECTION AT MIXING BOX FOR BALANCING. 3. PROVIDE WITH 7 DAY PROGRAMMABLE THERMOSTAT/CO2 SENSOR WITH AUTO COOLING / HEATING CHANGE OVER FOR ALL UNITS. 4. CONTRACTOR TO VERIFY WATER PIPE SIZING WITH EQUIPMENT MANUFACTURERS REPRESENTATIVE AND PROVIDE ENGINEER WITH CERTIFIED LETTER VERIFYING MANUFACTURERS SIZING. 5. CONTRACTOR TO PROVIDE RETURN AIR DAMPER OPERATION WITH AIR HANDLING UNIT FAN ON AHU-1. NOTES: (COOK AS STANDARD) NOTES: CENTRIFUGAL FAN SCHEDULE MARK MODEL SERVICE AIRFLOW E.S.P. DRIVE HP FAN SPEED POWER SUPPLY FLA WEIGHT NUMBER (CFM) (IN. H2O) (RPM) (VOLTS/PH/HZ) (LBS) EF-1 GC-144 EXHAUST 100.5 DIRECT 1/3 1200 115/1/60-55 1. PROVIDE FACTORY AVAILABLE AND INTEGRAL BACKDRAFT DAMPERS. 2. PROVIDE FACTORY AVAILABLE VIBRATION ISOLATORS. MARK FSD-1 FSD-2 FSD-3 FSD-4 FSD-5 OAD-1 NOTES: TYPE RATING DAMPER SCHEDULE SERVICE FIRE/SMOKE 1.5 HR CORRIDOR POTTORFF FSD-141 6"Ø 120VAC 1 FIRE/SMOKE 1.5 HR CORRIDOR POTTORFF FSD-141 6"Ø 120VAC 1 FIRE/SMOKE 1.5 HR CORRIDOR POTTORFF FSD-141 16x14 120VAC 1 FIRE/SMOKE 1.5 HR CORRIDOR POTTORFF FSD-141 16x14 120VAC 1 FIRE/SMOKE 1.5 HR CORRIDOR POTTORFF FSD-141 6"Ø 120VAC 1 VOLUME - AHU-1 POTTORFF CD-41 12x12-2 1. 120VAC ACTUATORS 2. MANUAL (GREENHECK AS STANDARD) NOTES: MFG HOOD SCHEDULE MODEL SIZE (INCHES) POWER NOTES MARK MODEL SERVICE AIRFLOW THROAT AREA MAX P.D. MAXIMUM DIMENSIONS (IN.) NUMBER (CFM) (SQ. FT.) (IN H2O) LENGTH WIDTH HEIGHT OAH-1 FGI AHU-1 300 1.0 0.04 24 22 21 1. PROVIDE FACTORY AVAILABLE ROOF CURB SUITABLE FOR INSTALLATION ON ROOF TYPE. 1005 N 11th Street Beaumont, TX 77702 04/08/2013 last saved: TRENT plotted: DRAWN BY: CHECKED BY: TLH DWD
04/08/2013
LIGHTING FIXTURE SCHEDULE 04/08/2013
04/08/2013
04/08/2013
04/08/2013
04/08/2013
04/08/2013 last saved: KENNY plotted: DRAWN BY: CHECKED BY: KR DWD
04/08/2013 last saved: KENNY plotted: DRAWN BY: CHECKED BY: KR DWD
04/08/2013 last saved: KENNY plotted: DRAWN BY: CHECKED BY: KR DWD