Split Commercial A/C. Commercial Air Conditioners S1610. R410A 50Hz. Commercial Air Conditioner Division Midea Group

Similar documents
Commercial Air Conditioners Split Commercial A/C. R410A 50Hz

Commercial Air Conditioners Rooftop Package. R410A 50Hz

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units

R410A VRF Indoor Unit 50Hz AC Series

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

COMMERCIAL AIR CONDITIONERS

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

Commercial Air Conditioners 2017/2018

Lennox Mini-Split Systems Year-Round Comfort and Performance

Product Line Introduction. Karl Zhang Technical support engineer

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Concealed Ducted Split Series R-407C MBH

Compact design & easy maintenance

LG VRF Systems. Air Conditioning Technologies

DC Inverter Smart VRF Products(R410A)

Residential and Light Commercial Ductless Systems Catalog

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

ROOFTOP PACKAGED AIR CONDITIONERS

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Midea CAC (MCAC) Year

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

R410 VRF Indoor Unit 50Hz

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Variable Refrigerant Flow

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

MODULAR CHILLER. R410a R22

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Mini unitary chiller. Mini unitary chiller

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

COMMERCIAL AIR CONDITIONERS. Air Handling Unit & Modular Air Handling Unit

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

High Heat COP. High/Low Stage

Advance Release September 2009

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

AHU Plus. DX Air Handling Units

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Commercial High-Efficiency Condensing Units

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

50TM TFF COMBINATION HEATING/COOLING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Modular Air Cooled Scroll Chillers

Commercial High-Efficiency Condensing Units

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

2 shp 13 lc 1 36 t - 1 a

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

TECHNICAL SPECIFICATIONS

TOSHIBA AIR CONDITIONING

LOW STATIC HYDRONIC DUCTED UNIT

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

A single answer for multiple zones.

Inverter Ducted Air Conditioners

Product Data. Fig. 1 - Unit 50VR -A

PACKAGE AIR CONDITIONER

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

CHAPTER 6 CONDENSING UNITS

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50TM COMBINATION HEATING/COOLING UNITS

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Heat Pump Air Conditioning Systems

PAJ3. Product Specifications

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

air systems Roomtop RTC-RTH 15 to 30 - L

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Amena s Globo series are a group of air conditioning products designed for markets where maximum

Air Cooled Scroll Chiller

Air Handling Unit & Modular Air Handling Unit

Transcription:

17051S1610 Coercial ir Conditioners 2017 Split Coercial /C R410 50Hz Coercial ir Conditioner Division Midea Group dd.: Midea Headquarters Building, 6 Midea venue, Shunde, Foshan, Guangdong, China Midea CC fterservice pplication Midea CC News pplication Postal code: 528311 Tel: +8675726338346 Fax: +8675722390205 cac.midea.com global.midea.com Note: Product specifications change from time to time as product improvements and ios Version ndroid Version ios Version developments are released and may vary from those in this document.

Midea CC Midea CC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and air conditioning solutions. Midea CC has continued with the tradition of innovation upon which it was founded, and emerged as a global leader in the HVC industry. strong drive for advancement has created a groundbreaking R&D department that has placed Midea CC at the forefront of a competitive field. Through these independent efforts and joint cooperation with other global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide. There are three production bases: Shunde, Chongqing and Hefei. MCC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and HU/FCU. MCC Chongqing: 14 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, ir Cooled Screw/Scroll Chillers, and HU/FCU. MCC Hefei: 11 product lines focusing on VRF, Chillers, and Heat Pump Water Heaters. Midea Company Introduction Midea CC Introduction 2015 JV with Carrier in China in chiller field, BOSCH in VRF production and Siix in smart control 2014 Launched the duct indoor unit with belt drive fan globally 2010 Built the 3rd manufacturing base in Hefei 2008 Launched the rooftop package ClimaMaster globally 2007 Won the first Midea centrifugal chiller project overseas 2006 Launched the first VSD centrifugal chiller 2004 cquired MGRE entered the chiller industry 2001 Partnered with Copeland to develop the digital scroll VRF system 2000 Developed the first inverter VRF With Toshiba 1999 Entered the CC field

Contents 04 Introduction Introduction Introduction 06 General Features Convenient for unit selection Outstanding reliability Easy to installation Flexible choise of accessories Mechanical specification 10 DX HU Series DX HU (ir Handler Unit) Midea split type air conditioners are designed and manufactured to meet the requirements of the home, office, hotel and others public occasion use. The units are completely assembled, internally wired, charged outdoor unit with refrigerant at the factory. DX HU (ir Handler Unit) Series pplication Power supply 220~240V, 1Ph~, 50Hz Series Indoor units (DX HU) Nominal cooling capactity 24k 36k 48k 60k 18 R410 T3 Duct Indoor Unit Floorstanding Indoor Unit 39 s 380~415V, 3Ph~, 50Hz Outdoor units 1. Product s cooling capacity as per specification. 03 04

Introduction Conventional Split /C Series pplication Power Supply Series Medstatic Pressure Duct Nominal 76 k 96 k 120 k 150 k 192 k General Features General Features R410 T1 (Heat Pump) 220240V, 1Ph, 50Hz Indoor Unit Histatic Pressure Duct Convenient for unit selection Floorstanding Wide cooling capacity range 380415V, 3Ph, 50Hz Outdoor Unit Wide cooling capacity range. The duct type split /C is from 76,000 to 192,000. R410 T1 (DC Inverter) (Heat Pump) 220240V, 1Ph, 50Hz 380415V, 3Ph, 50Hz Indoor Unit Outdoor Unit Histatic Pressure Duct Long piping length Max. equivalent piping length is 50m. The outdoor unit can be installed at any ventilation locations. (Unavailable for HU type) Permitted value R410 T3 ( Only) 220240V, 1Ph, 50Hz Indoor unit Medstatic Pressure Duct Histatic Pressure Duct Floorstanding Max. Equivalent piping length Max. height drop between indoor and outdoor unit Outdoor unit up Outdoor unit down 50 m 25 m 30 m Max. equivalent piping length: 50m Max. height drop 380415V, 3Ph, 50Hz Outdoor Unit Medstatic Pressure Duct Outstanding reliability R410 T3 (Heat Pump) 220240V, 1Ph, 50Hz Indoor Unit Histatic Pressure Duct Durable construction Prepainted exterior cabinet panels pass 1000 hours Salt Spray Test for durability. Weatherresistant construction with capped steams and sloped top panels. Floorstanding G90 galvanized heavy gauge plate conforming to STM653. 380415V, 3Ph, 50Hz Outdoor Unit 1. Product s cooling capacity as per specification. 05 06

nticorrosion treatment as optional Flexible choise of accessories The large split air conditioners with special anticorrosion treatment are suitable for seaside areas or the areas exposed to acidic substances. s General Features Special anticorrosion treatment of heat exchanger provides 5 to 6 times greater resistance against acid rain and salt corrosion. ll PCB parts in the unit are coated with doubleside Wireless remote controller is available for conventional split /C series. can be directly connected with duct & floorstanding indoor unts. General Features moisture proof paint. The outer side of electric box metal cover is spraypainted. ll screws are antirust. Casings of the unit and motors are antirust. R51/CE KJR29B Reliable scroll compressor Centralized control function can be achieved through the centralized controller as optional. MDNIM01 should be connected between the indoor units and centralized controller. (Only available for conventional split /C series) Famous brand compressor: Hitachi, Danfoss, etc. More reliable. No complex internal suction and discharge valves for quieter operation and higher reliability. Compact, lightweight design, and fewer moving parts design. Multiprotection design Max.64 MDNIM01 MDNIM01 MDNIM01 MDNIM01 CCM30 Multimeasurement to ensure units operate normally and reliably: Multiaccessories System current protection, High/low pressure switch protection, Temperature sensor on/off protection, etc. Threephase protector is optional. HP/LP switch Temperature sensor Description Standard T1, Duct Tropical (T3), Duct T1 & Tropical (T3), Floorstanding Optional Standard Optional Standard Optional Easy for installation Filter Units are completely assembled, internally wired, charged outdoor unit with refrigerant at the factory. Outlet drainage The site work only needs to connect refrigerant pipes and counication wires between outdoor unit and indoor unit. EHK (Electric Heater Kits) Liquid pipe Gas pipe Connecting cable Threephase protector Wireless controller Centralized controller 07 08

Mechanical specification General Features Casing Unit casing is constructed of heavy gauge galvanized steel plate. Both side of the casing is waterproof and anticorrosion coated. Unit panel structure is allowed to maintain on one side of the unit. Service panels are removed easily and reinstalled by removing bolts. The inside of indoor unit panels will be covered with 10 insulation to prevent heat and noise coming out. Units are available for forklift transportation. Compressor ll units are equipped with directdrive, hermetic, scroll type compressor, and it s builtin motor is cooled with suction gas. The voltage utilization range is ±10% of unit nameplate voltage. The compressors, incorporating a builtin muffler, are mounted on springs within a steel housing to reduce noise. n electric heater around the compressor crankcase to ensure stability starting. DX HU Series DX HU (ir Handler Unit) DX HU Series Heatexchanger coils Innerthreaded copper tubes mechanically bonded to a configured hydrophilic aluminum fin is standard for the outdoor heatexchanger. The one which is equipped in indoor unit is standard configurated with copper tubes. ll the coils are leak tested at 4.4MPa at the factory to ensure the pressure integrity. ll the indoor units are standard configurated a condensate drain pan. Outdoor fan The outdoor fan is multiblade vaneaxial type, made of aluminum alloy for quiet operation and durability. It is directly driven by waterproof motor to ensure reliable continuous operations. Statically and dynamically balanced drive motor design with maintenancefree bearing for outdoor installation. Indoor fan The indoor fan is forwardcurved blade centrifugal fan. Impeller and casing are made of galvanized steel sheet. The high quality ball bearings are airsealed with preset lubricating oil. They are coated after assembly in order to provide corrosion resistance. The fan is directly driven by a waterproof motor. The fan and motor assembly is tested and dynamic balance is implemented in the factory. DX HU Flexible installation Flange of air flow is standard. Dual drainage spouts for versatile installation. Multiple airflow design: Vertical upflow, Vertical downflow, Horizontal leftflow and horizontal rightflow. Outdoor unit KJR23B (Optional) Threephase protector The unit with threephase power supply is equipped with phase sequence protector as optional. These devices protect motors and compressors against problems caused by phase lack, phase imbalance and phase reversal indication. When the voltage is above or below the normal range, it works and prevents unit from suffering voltage fluctuations. ir intake ir delivery Refrigerant pipes Controls Units are completely factorywired with necessary controls and wiring terminals for power wiring. Microprocessor controls the cooling, heating and ventilating modes in response to signals from sensors measuring indoor and outdoor temperatures. It will keep accurate temperature control, minimum drift from the set point and provide better building comfort. Horizontal installation Drainage spouts Washable filter as optional 09 10

Specifications Tropical (T3) application, DX HU Indoor unit s T3 application, DX HU Indoor unit Indoor unit model MV24CWN113 MV36CWN113 MV48CWN113 MV60CWN113 Indoor unit power supply (T1/T3) (T1) MOVT24CN113C 220240V, 1Ph~, 50Hz 24,000 / 20,400 7.0 MOVT36CN1(R)13C 220240V, 1Ph~, 50Hz 36,000 / 30,400 10.4 MOVT48CN1R13C 220240V, 1Ph~, 50Hz 48,000 / 40,500 14.0 MOVT60CN1R13C 220240V, 1Ph~, 50Hz 58,000 / 49,000 17.0 High voltage connection 262 Flanges are provided for field installation W DX HU Series SEER (T1) ir flow (Hi) Standard external static pressure (Hi) Max. external static pressure (Hi) (Hi) CFM Pa Pa 13 13 920 1,470 45 60 150 150 49 55 13 13 1,900 2,010 70 75 150 150 57 59 Breaker switch (For electric heater only) DX HU Series KJR23B (Optional) KJR23B (Optional) KJR23B (Optional) KJR23B (Optional) H Supply duct dimension (W D) Net (W H D) 406 262 457 262 460 1,050 520 500 1,180 550 534 1,104 580 573 1,234 610 50 / 56 64 / 70 495 262 495 262 560 1,385 610 560 1,385 610 634 1,438 670 634 1,438 670 78 / 85 78 / 85 Vapor line connection copper Liquid line connection copper MV24CWN113 (Unit: ) H W D 1,050 460 520 406 Tropical (T3) application, DX HU Outdoor unit MOVT24CN113C MOVT36CN113C MOVT36CN1R13C MOVT48CN1R13C MOVT60CN1R13C 220240V, 1Ph~, 50Hz 380415V, 3Ph~, 50Hz (Outdoor unit) W 2,650 3,950 4,050 5,950 6,800 uxiliary drain connection uxiliary drain connection Primary drain connection D MV36CWN113 MV48CWN113 MV60CWN113 1,180 500 550 456 1,385 560 610 496 1,385 560 610 496 62 64 64 68 68 Compressor Refrigerant Type Quantity Type Charged Scroll Scroll 1 1 R410 R410 2.52 3.57 Scroll 1 R410 3.62 Scroll 1 R410 3.92 Scroll 1 R410 4.32 T3 application, DX HU Outdoor unit ir flow CFM 1,766 3,000 3,000 3,396 4,031 Fan Type Drive type xial xial xial xial xial Direct Direct Direct Direct Direct W Refrigerant piping size mbient temperature C Φ9.52 / Φ19 Φ9.52 / Φ19 17~52 17~52 Φ9.52 / Φ19 17~52 Φ9.52 / Φ22 17~52 Φ9.52 / Φ22 17~52 L Weight Body (W H D) 600 633 600 628 667 628 710 759 710 738 793 738 Net 59 86 Gross 62 90 710 759 710 738 793 738 81 85 710 843 710 738 877 738 89 93 740 843 740 768 877 768 98 102 ir inlets Louvered panels H L W (Unit: ) H 1. T1 capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. The standard external static pressure and air flow is based on cooling performance without filter in place. 4. Specifications are subject to change without prior notice for product improvement. Service access MOVT24CN113C MOVT36CN113C MOVT36CN1R13C MOVT48CN1R13C MOVT60CN1R13C 600 600 633 710 710 759 710 710 759 710 710 843 740 740 843 11 12

Specifications T1 pplication Medium static pressure duct, heat pump Duct Indoor Unit Indoor unit model / Quantity Indoor unit power supply MTB76HWN1 MOV76HN1R / 1 220240V, 1Ph~, 50Hz 76,000 22.3 7.5 MTB76HWN1 MTB120HWN1 MTB120HWN1 MOV120HN1R / 1 220240V, 1Ph~, 50Hz 120,000 35.0 11.9 EER 2.97 2.94 Convenient installation COP 85,300 25.0 8.3 3.01 129,700 38.0 12.7 2.99 Compact design. Concealed installation without floor space requirement. Hidden in the ceiling, unit installation is not hindered by the location of lighting fixtures or room structure. ir inlet & outlet flange are standard for easy duct connection. Easy maintenance through the inspection port. ir flow (Hi) Standard external static pressure (Hi) W m 3 /h Pa 1,300 5.2 4,250 (2,500CFM) 100 56 2,000 9.0 6,375 (3,750CFM) 100 63 Free air duct design Multi diffusers from one indoor unit, airconditioned multi rooms at the same time. Three speeds of air supply can be chosen via controller. The indoor unit is suitable for various applications where there are many rooms or halls, such as restaurant, concert halls and hotels. Flexible duct design for different room styles. Fan Type Drive type Net (W H D) Centrifugal Direct 1,452 462 797 1,555 500 875 94 / 106 Centrifugal Direct 1,452 462 797 1,555 500 875 97 / 109 1. capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. uto Restart Function uto Defrosting Independent Dehumidification Timer PTC Heater nticold ir Function Wired 13 14

Specifications T1 pplication High static pressure duct, heat pump MOV76HN1R MOV120HN1R MOV76HN1R MOV120HN1R 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 11.7 (Outdoor unit) 17.3 (Outdoor unit) 19.3 (Outdoor unit) 28.6 (Outdoor unit) ir flow rate m 3 /h 12,500 13,000 68 69 Compressor (Type / Quantity) Scroll / 1 Scroll / 1 Refrigerant (Type / Quantity) R410 / 5.4 R410 / 7.5 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) Φ12.7 (Liquid), Φ28.6 (Gas) mbient temperature C 17~46 17~46 C 7~24 7~24 Body (W H D) 1,260 908 700 1,260 908 700 1,320 1,060 730 1,320 1,060 730 174 / 193 201 / 217 1. capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. Indoor unit model / Quantity Indoor unit power supply EER COP ir flow (Hi) Standard external static pressure (Hi) Type Fan Drive type MHB76HWN1 MHB76HWN1 MOV76HN1R / 1 220240V, 1Ph~, 50Hz 76,000 22.3 7.5 2.97 85,300 25.0 8.3 3.01 W 1,300 5.2 m 3 /h 4,250 (2,500CFM) Pa 196 56 Centrifugal Direct MH150HWN1 MH192HWN1 MH150HWN1 MOV150HN1R / 1 220240V, 1Ph~, 50Hz 150,100 44.0 16.3 2.70 160,300 47.0 15.7 2.99 2,730 12.1 8,500 (5,000CFM) 196 63 Centrifugal Direct MH192HWN1 MOV192HN1R / 1 220240V, 1Ph~, 50Hz 192,000 56.3 22.0 2.56 200,000 58.6 19.3 3.04 4,690 20.9 10,800 (6,350CFM) 196 65 Centrifugal Direct Net (W H D) 1,452 462 797 1,555 500 875 1,988 669 906 2,095 800 964 1,988 669 906 2,095 800 964 94 / 106 208 / 220 215 / 230 1. capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. 15 16

Specifications T1 pplication DC inverter high static pressure duct, heat pump MOV76HN1R MOV150HN1R MOV192HN1R MOV76HN1R MOV150HN1R MOV192HN1R 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 11.7 (Outdoor unit) 26.9 (Outdoor unit) 32.2 (Outdoor unit) 19.3 (Outdoor unit) 47.9 (Outdoor unit) 53.8 (Outdoor unit) ir flow rate m 3 /h 12,500 16,000 16,000 68 70 73 Compressor (Type / Quantity) Scroll / 1 Scroll / 3 Scroll / 3 Refrigerant (Type / Quantity) R410 / 5.4 R410 / 10.0 R410 / 11.8 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) Φ16 (Liquid), Φ32 (Gas) Φ16 (Liquid), Φ32 (Gas) mbient temperature C 17~46 17~46 17~46 C 7~24 7~24 7~24 Body (W H D) 1,260 908 700 1,250 1,615 765 1,390 1,615 765 1,320 1,060 730 1,305 1,790 820 1,455 1,790 830 174 / 193 288 /308 320 / 336 Model / Quantity Power supply ir flow (H) \ MHC176HWD1N1 MHC96HWD1N1 MHC96HWD1N1()N1 MHC176HWD1N1 MHC96HWD1N1 MHC96HWD1N1() MOVG176HD1N1R / 1 MOVG176HD1N1R / 1 MOU96HD1N1R / 1 220240V~, 1Ph, 50Hz 220240V~, 1Ph, 50Hz 220240V~, 1Ph, 50Hz 85300 102300 95500 25.0 30.0 28.0 7.50 9.80 9.00 EER 3.23 3.23 3.11 85,300 102,300 107,000 25.0 30.0 31.5 7.5 9.8 8.50 COP 3.23 3.31 3.71 W 650 850 850 4 4.5 4.5 m 3 /h 5000 5000 4800 1. capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. External static pressure (H) Fan Pa 0 ~ 200 0 ~ 200 0~150 56 56 52 Type \ Centrifugal Centrifugal Centrifugal Drive type \ Direct Direct Direct \ \ Refrigerant pipe Liquid Ф12.7 Ф12.7 Ф9.52 Gas Ф28.6 Ф28.6 Ф25.4 Body (W H D) 1,470 510 795 1,470 510 795 1,470 512 775 1,555 545 875 1,555 545 875 1,555 545 875 83 / 94 83 / 92 83 / 92 1. T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. 17 18

Specifications Tropical (T3) pplication Medium static pressure duct, heat pump Model ir flow MOVG176HD1N1R MOVG96HD1N1R MOU96HD1N1R MOVG176HD1N1R MOVG96HD1N1R MOU96HD1N1R \ 380415V~, 3Ph, 50Hz 8 (Whole unit) 380415V~, 3Ph, 50Hz 9.25 (Whole unit) 380415V~, 3Ph, 50Hz 11.7 (Whole unit) 16 16 16 66 66 59 m 3 /h 13,500 13,500 9,800 MT76HRN1 Indoor unit model / Quantity Indoor unit power supply (T1/T3) (T1/T3) MTB1T96HWN1 MT76HRN1 MOV76HN1C / 1 220240V, 1Ph~, 50Hz 75,100 / 64,100 22.0 / 18.8 7.5 / 8.85 MTB1T96HWN1 MOVT96HN1R / 1 220240V, 1Ph~, 50Hz 96,000 / 87,860 28.1 / 25.75 9.6 / 15.00 MT120HRN1 MT120HRN1 MOV120HN1C / 1 220240V, 1Ph~, 50Hz 119,400 / 102,400 35.0 / 30.0 12.0 / 13.25 Compressor Rdfrigerant Fan type Refrigerant pipe mbient temperature Type \ Inverter scroll Inverter scroll Rotary Quantity \ 1 1 1 Type \ R410 R410 R410 Quantity \ 9.0 10.0 7.2 \ xial fan xial fan xial fan \ Liquid Ф12.7 Ф12.7 Ф9.52 Gas Ф28.6 Ф28.6 Ф25.4 C 15~48 15~48 15~48 C 15~24 15~24 15~24 Body (W H D) 948 1,585 968 948 1,585 968 1,120 1,558 400 1,010 1,705 1,000 1,010 1,705 1,000 1,270 1,720 565 231 / 242 231 / 256 148 / 164 1. T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. EER (T1) 2.92 85,000 106,000 130,000 25.0 31.1 38.0 8.3 10.3 12.6 COP 3.01 3.02 3.02 ir flow (Hi) Standard external static pressure W m 3 /h Pa 11,700 (Whole units) 19.3 (Whole units) 4,250 (2,500CFM) 100 1,400 (IDU) 5.8 (IDU) 5,100 (3,000CFM) 100 17,300 (Whole units) 28.6 (Whole units) 6,375 (3,750CFM) 150 (Hi) 58 56 63 Wireless controller Wireless controller Net (W H D) 1,443 450 846 1452 462 797 1,988 669 906 1,549 476 917 1,555 500 875 2,095 800 964 105 / 120 97 / 109 188 / 220 1. T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. 19 20

Specifications Tropical (T3) pplication Medium static pressure duct, cooling only MOV76HN1C MOVT96HN1R MOV120HN1C MOV76HN1C MOVT96HN1R MOV120HN1C 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 17.3 (Whole units) 19.3 (Whole units) 23.7 (ODU) 28.6 (Whole units) ir flow rate m 3 /h 12,500 12,500 13,000 65 68 69 Compressor(Type / Quantity) Scroll / 1 Scroll / 1 Scroll / 1 Refrigerant(Type / Quantity) R410 / 5.4 R410 / 6.0 R410 / 7.2 Refrigerant piping size Φ9.52(Liquid), Φ22(Gas) Φ9.52(Liquid), Φ25(Gas) Φ12.7(Liquid), Φ28.6(Gas) mbient temperature Body (W H D) C 17~52 1,260 908 700 17~52 1,312 919 658 17~52 1,260 908 700 C 7~24 1,320 1,060 730 7~24 1,320 1,060 730 7~24 1,320 1,060 730 174 / 193 177 /192 201 / 217 MT76CRN1 MTB1T96CWN1 MT120CRN1 MT150CRN1 Indoor unit model MT76CRN1 MTB1T96CWN1 MT120CRN1 MT150CRN1 / Quantity MOV76CN1C / 1 MOVT96CN1R / 1 MOV120CN1C / 1 MOV76CN1C / 2 Indoor unit power supply 220240V, 1Ph~, 50Hz 220240V, 1Ph~, 50Hz 220240V, 1Ph~, 50Hz 220240V, 1Ph~, 50Hz 75,100 / 64,100 96,000 / 87,860 119,400 / 102,400 150,100 / 130,300 (T1/T3) 22.0 / 18.8 28.1 / 25.75 35.0 / 30.0 44.0 / 38.2 (T1/T3) 7.5 / 8.85 9.6 / 15.0 12.0 / 13.25 15.1 / 18.00 EER (T1) 2.92 2.91 COP 11.7 (Whole units) 19.3 (Whole units) 1.4 (IDU) 5.8 (IDU) 17.3 (Whole units) 28.6 (Whole units) 21.2 (Whole units) 35.0 (Whole units) ir flow (Hi) Standard external static pressure m 3 /h Pa 4,250 (2,500CFM) 100 5,100 (3,000CFM) 100 6,375 (3,750CFM) 150 7,650 (4,500CFM) 150 (Hi) 58 56 63 79 1. T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. Wireless controller Wireless controller Wireless controller Net (W H D) 1,443 450 846 1,452 462 797 1,988 669 906 1,988 669 906 1,549 476 917 1,555 500 875 2,095 800 964 2,095 800 964 105 / 120 97 / 109 188 / 220 188 / 200 1. T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. 21 22

Specifications Tropical (T3) pplication High static pressure duct, heat pump & cooling only Heat pump: Heat pump: MHB76HRN1 MHB1T96HWN1 MOV76CN1C MOVT96CN1R MOV120CN1C MOV76CN1C MOVT96CN1R MOV120CN1C 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 17.3 (Whole units) ir flow rate m 3 /h 19.3 (Whole units) 12,500 23.7 (ODU) 12,500 28.6 (Whole units) 13,000 65 68 69 Compressor (Type / Quantity) Scroll / 1 Scroll / 1 Scroll / 1 Refrigerant (Type / Charged) R410 / 5.4 R410 / 6.0 R410 / 7.2 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) Φ9.52 (Liquid), Φ25 (Gas) Φ12.7 (Liquid), Φ28.6 (Gas) mbient temperature C 17~52 17~52 17~52 only: MHB76CRN1 Indoor unit model / Quantity Indoor unit power supply (T1/T3) (T1/T3) EER (T1) COP MHB76HRN1 MOV76HN1C / 1 220240V, 1Ph~, 50Hz 75,100 / 64,100 22.0 / 18.8 7.5 / 8.85 85,000 25.0 8.3 3.01 11.7 (Whole units) only: MHB1T96CWN1 MHB1T96HWN1 MHB76CRN1 MHB1T96CWN1 MOVT96HN1R / 1 MOV76CN1C / 1 MOVT96CN1R / 1 220240V, 1Ph~, 50Hz 220240V, 1Ph~, 50Hz 220240V, 1Ph~, 50Hz 96,000 / 87,860 28.1 / 25.75 9.6 / 15.00 106,000 75,100 / 64,100 22.0 / 18.8 7.5 / 8.85 96,000 / 87,860 28.1 / 25.75 9.6 / 15.00 31.1 10.3 3.02 1.4 (IDU) 11.7 (Whole units) 1.4 (IDU) Body (W H D) 1,260 908 700 1,320 1,060 730 1,312 919 658 1,320 1,060 730 1,260 908 700 1,320 1,060 730 ir flow (Hi) m 3 /h 19.3 (Whole units) 4,250 (2,500CFM) 5.8 (IDU) 5,100 (3,000CFM) 19.3 (Whole units) 4,250 (2,500CFM) 5.8 (IDU) 5,100 (3,000CFM) 171 / 190 168 / 183 199 / 215 Standard external static pressure Pa 196 196 196 196 (Hi) 58 56 58 56 1. T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. Net (W H D) Wireless controller Wireless controller 1,443 450 846 1,549 476 917 1,452 462 797 1,555 500 875 1,443 450 846 1,549 476 917 1,452 462 797 1,555 500 875 105 / 120 97 / 109 105 / 120 97 / 109 1. T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. 23 24

Floorstanding Indoor Unit Heat pump: MOV76HN1C MOVT96HN1R only: MOV76CN1C MOVT96CN1R MOV76HN1C MOVT96HN1R MOV76CN1C MOVT96CN1R 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 11.7 (Whole units) 14.4 (ODU) 19.3 (Whole units) 23.7 (ODU) 19.3 (Whole units) 23.7 (ODU) ir flow rate m 3 /h 12,500 12,500 12,500 12,500 Strong wind, long distance air supply R51/CE R51/E 65 68 65 68 Compressor(Type / Quantity) Scroll / 1 Scroll / 1 Scroll / 1 Scroll / 1 Refrigerant(Type / Quantity) R410 / 5.4 R410 / 6.0 R410 / 5.4 R410 / 6.0 Refrigerant piping size Φ9.52(Liquid), Φ22(Gas) Φ9.52(Liquid), Φ25(Gas) Φ9.52(Liquid), Φ22(Gas) Φ9.52(Liquid), Φ25.4(Gas) mbient temperature C 17~52() / 7~24() 17~52() / 7~24() 17~52() 17~52() Body (W H D) 1,260 908 700 1,312 919 658 1,260 908 700 1,312 919 658 1,320 1,060 730 1,320 1,060 730 1,320 1,060 730 1,320 1,060 730 174 / 193 177 /192 171 / 190 168 /183 1. T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. Touch screen control Washable inlet air filter Screw Screw cap ir intake panel Electrical box, ir filter nticold ir Function uto Restart Function uto Defrosting Independent Dehumidification Timer PTC Heater Features: Standard Optional 25 26

Specifications T1 pplication Heat pump Specifications Tropical (T3) pplication Heat pump Indoor unit model / Quantity Indoor unit power supply EER COP W MF276HRN1 MOV76HN1R / 1 220240V, 1Ph~, 50Hz 76,000 22.3 7.5 2.97 85,300 25.0 8.3 3.01 700 Indoor unit model / Quantity Indoor unit power supply (T1/T3) (T1/T3) EER (T1) COP MF76HRN1 MOV76HN1C / 1 220240V, 1Ph~, 50Hz 75,100 / 64,800 22.0 / 19.0 7.5 / 8.98 85,000 25.0 8.3 3.01 11.7 (Whole units) MF3T96HRN1 MOVT96HN1R / 1 220240V, 1Ph~, 50Hz 96,000 / 87,860 28.1 / 25.75 9.6 / 15.00 106,000 31.1 10.3 3.02 0.7 (IDU) 3.0 19.3 (Whole units) 3.0 (IDU) ir flow (Hi) m 3 /h 4,300 (2,530CFM) ir flow (Hi) m 3 /h 4,250 (2,500CFM) 4,800 (2,825CFM) 56 58 56 Remote controller Remote controller Remote controller Net (W H D) 1,200 1,860 518 1,362 2,050 582 Net (W H D) 1,200 1,860 518 1,362 2,050 582 1,200 1,860 518 1,362 2,050 582 130 / 145 158 / 174 140 / 154 MOV76HN1R 380415V, 3Ph~, 50Hz 11.7 19.3 ir flow rate m 3 /h 12,500 68 Compressor (Type / Quantity) Scroll / 1 Refrigerant (Type / Quantity) R410 / 5.4 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) mbient temperature C 17~46 () / 7~24 () Body (W H D) 1,260 908 700 1,320 1,060 730 174 / 193 1. capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. MOV76HN1C MOVT96HN1R 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 19.3 (Whole units) 23.7 (ODU) ir flow rate m 3 /h 12,500 12,500 65 68 Compressor (Type / Quantity) Scroll / 1 Scroll / 1 Refrigerant (Type / Quantity) R410 / 5.4 R410 / 6.0 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) Φ9.52 (Liquid), Φ25 (Gas) mbient temperature C 17~52 () / 7~24 () 17~52 () / 7~24 () Body (W H D) 1,260 908 700 1,312 919 658 1,320 1,060 730 1,320 1,060 730 174 / 193 177 /192 1. T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB. 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB. 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB. 4. Refrigerant pipe length between indoor unit and outdoor 5. Specifications are subject to change without prior notice for product improvement. 27 28

Specifications s Tropical (T3) pplication only T1 application Duct indoor unit: MTB76HWN1, MTB120HWN1, MHB76HWN1, (Units: ) Indoor unit model / Quantity Indoor unit power supply (T1/T3) (T1/T3) EER (T1) COP MF76CRN1 MOV76CN1C / 1 220240V, 1Ph~, 50Hz 75,100 / 64,800 22.0 / 19.0 7.5 / 8.98 11.7 (Whole units) 19.3 (Whole units) MF3T96CRN1 MOVT96CN1R / 1 220240V, 1Ph~, 50Hz 96,000 / 87,860 28.1 / 25.75 9.6 / 15.00 0.7 (IDU) 3.0 (IDU) MFT120CRN1 MOV120CN1C / 1 220240V, 1Ph~, 50Hz 121,000 / 110,900 35.0 / 32.5 13.0 / 15.50 2.69 17.3 (Whole units) 28.6 (Whole units) 1,372 704 1,231 T1 application Duct indoor unit: MHC176HWD1N1,MHC96HWD1N1,MHC96HWD1N1() (Units: ) 1,372 775 462 462 224 47 24 196 112 797 758 153 30 ir flow (Hi) m 3 /h 4,250 (2,500CFM) 58 4,800 (2,825CFM) 56 6,060 (3,560CFM) 65 512 512 238 Net (W H D) Remote controller 1,200 1,860 518 1,362 2,050 582 Remote controller 1,200 1,860 518 1,362 2,050 582 Remote controller 1,200 1,860 518 1,362 2,050 582 1,246 75 45 112 24 158 / 174 140 / 154 148 / 174 T1 application Duct indoor unit: MH150HWN1, MH192HWN1 (Units: ) 1,834 858.5 106 123 47 MOV76CN1C MOVT96CN1R MOV120CN1C 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 380415V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 17.3 (Whole units) 19.3 (Whole units) 23.7 (ODU) 28.6 (Whole units) ir flow rate m 3 /h 12,500 12,500 13 00 65 68 69 645 1,895 24 56.5 180 749.5 180 15 Compressor (Type / Quantity) Refrigerant (Type / Charged) Refrigerant piping size mbient temperature Body (W H D) C Scroll / 1 R410 / 5.4 Scroll / 1 R410 / 6.0 Scroll / 1 R410 / 7.2 Φ9.52 (Liquid), Φ22 (Gas) Φ9.52 (Liquid), Φ25 (Gas) Φ12.7 (Liquid), Φ28.6 (Gas) 17~52 17~52 17~52 1,260 908 700 1,312 919 658 1,260 908 700 1,320 1,060 730 1,320 1,060 730 1,320 1,060 730 Tropical (T3) application Duct indoor unit: MT76HRN1, MT76CRN1 MHB76HRN1, MHB76CRN1 (Units: ) 1,350 760 656 469 45 171 / 190 168 / 183 1. T1 capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB. 2. T3 capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB. 3. Refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. 199 / 215 1,205 450 231 132 26 840 507 800 180 29 30

Tropical (T3) application Duct indoor unit: MTB1T96HWN1, MTB1T96CWN1 MHB1T96HWN1, MHB1T96CWN1 (Units: ) T1 & Tropical (T3) application Floorstanding indoor unit: MF276HRN1, MF76HRN1, MF76CRN1, MF3T96HRN1, MF3T96CRN1, MFT120CRN1 (Units: ) 420 1,200 960 118 1,372 704 797 758 1,231 Tropical (T3) application Duct indoor unit: MT120HRN1, MT120CRN1 (Units: ) 462 462 224 47 24 196 112 30 153 1,860 93 1,196 140 T1 & Tropical (T3) application Outdoor unit: MOV76HN1R, MOV76HN1C, MOV76CN1C (Units: ) 1,260 654 762 460 1,834 858.5 106 123 47 908 700 676 645 1,895 24 56.5 180 749.5 180 15 179 T1 & Tropical (T3) application Outdoor unit: MOVT96HN1R, MOVT96CN1R (Units: ) 1,260 658 57 1,312 Tropical (T3) application Duct indoor unit: MT150CRN1 (Units: ) 919 105 435 1,288 87 91 1,834 858.5 106 123 47 69 206 645 1,895 168 259.5 24 56.5 108 749.5 180 15 T1 & Tropical (T3) application Outdoor unit: MOV120HN1R, MOV120HN1C, MOV120CN1C (Units: ) 1,260 654 908 762 700 676 31 32 519 737

T1 application Outdoor unit: MOU96HD1N1R (Units: ) 1,470 528 1,120 Remote R51 Parameter T1 pplication Outdoor unit: MOVG176HD1N1R, MOVG96HD1N1R (Units: ) s Model: R51/CE ( only type) R51/E (Heat pump type) (): 140 60 15 Power: 1.5V (LR03/) 2 1,572 s 970 T1 application Outdoor unit: MOV150HN1R (Units: ) 1,250 Standard features It provides a convenient way for users to control the air conditioners everywhere within a range up to 11m. Builtin daily timer offers the convenience of automatically starting and turning down the air conditioners according to the set time. 948 Wired KJR29B 765 1,250 Parameter 1,615 Model: KJR29B (Touchstyle key) 765 (): 120 120 20 Power: From the display panel, extra power is unnecessary. 736 T1 application Outdoor unit: MOV192HN1R (Units: ) Standard features 1,200 Keyboard locking function as standard, it can be used to prevent other people from using the controller. Builtin daily timer offers the convenience of automatically starting and turning down the air conditioners according to the set time. 1,390 1,615 1,2 60 33 Remote signal receiving function 765 KJR29B provides a signal receiver to receive the signal from remote controller. The received signal can be directly sent to the indoor unit by wired controller. It is convenient to control the air conditioner. Remote signal receiver Silent Key 6 73 34

Silent mode During the operating, when operate the silent mode, the units can reduce the running noise through setting the fan speed to low automatically. It will help you bring a quieter environment. Centralized CCM30 CCM30 MDNIM01 Centralized control Parameter Model: CCM30 + MDNIM01 (): 180 122 78 (CCM30BKEB) 180 122 68 (CCM30BKE) 81.8 46.8 15.5 (MDNIM01) Power: 198~242V, 50/60Hz (MDCCM30) DC+5V (MDNIM01) s MDCCM30, centralized controller, is a multifunctional device that can control up to 64 indoor units within a maximum connection length of 1200m. User can group control or individual control and the set temperature of each units can also different. The indoor units working status and error codes can be displayed in the screen of CCM30. Via checking the error codes table in the user manual, user can easily find out the malfunction and call the service engineer. Three lock modes Centralized controller provides a superior way to manage the indoor units. Users can be able to make their own choice from three locking mode: locking the wireless controller, locking the running mode or locking centralized controller keyboard as they wish. ccess to network monitoring MDCCM30 is able to bridge up to 64 indoor units to network monitoring system and building management system. s Max.64 MDNIM01 MDNIM01 MDNIM01 MDNIM01 CCM30 Easy installation Two structures design, easy installation. Structure (Model No. CCM30/BKE) should be embedded into the wall and structure B (Model No. CCM30/BKEB) doesn t need. Upper side outlet Rear side outlet Structure Structure B Under side outlet Structure B leadingout mode sketch 35 36