ECOi TM Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems
ECOi Building Your Business. Panasonic has a proud global heritage and over 5 years experience in the United States and we deliver more multizone options, space-saving designs and solutions to protect the environment. Our products reduce your energy costs and create a more comfortable environment. Today every conditioning solution must answer multitudes of project needs, including tighter budgets, flexibility, energy efficiency and ease of installation, to name a few. ECOi is the answer. It s an all-in-one solution that responds to the many commercial and residential applications. Panasonic's Brand Vision. Panasonic's HVAC consistently offers new ideas to help build your business. By delivering multi-zone options, space-saving and environmentally friendly designs, our solutions are evolving, improving solutions. Flexible Combinations: ECOi allows multiple indoor unit combinations that provide you with the utmost in flexible solutions. The system also allows multiple unit connectivity providing up to 13% of the total capacity of the condensing unit. This provides for up to 16 indoor units connected to one condensing unit. Inverter Control Compressor: All ECOi systems utilize highly advanced inverter controlled compressor technology. By varying the rotational speed of the compressor, the inverter control can precisely match the amount of refrigerant being delivered to the needs of each zone. This intelligent approach helps realize excellent efficiencies during partial-load conditions, which allows all occupants to enjoy consistent room temperature, regardless of any increases or decreases in the heat load during the day. ECOi quite simply knows what you need, and when you need it throughout the day. And even better, it does so with energy efficiency in mind. Lower running and life cycle costs: Panasonic Ecoi VRF systems are amongst the most efficient VRF systems on the market, offering COPs in excess of 4. at full load conditions. The system is also designed to make sure that we reduce the running cost of each system by using our unique road map control routine to ensure that the most efficient combination of compressors are running at any one time. Improved defrost sequencing also reduces running cost by defrosting each out door coil in turn when conditions allow. Table of Contents 2 INTRODUCTION...2 ECOi Building Your Business/Brand Vision...2 For the Living Inside & Out...3 ECOi Your Building Life Tool...3 The New Panasonic Group...4-5 MF 3-Way ECOi VRF Heat Recovery...6-7 LE and ME 2-Way ECOi VRF Heat Pump ECOi Series Model Code...6 OUTDOOR Units....8 MF 3-Way ECOi VRF Heat Recovery...8 Combined MF 3-Way ECOi VRF Heat Recovery...1 LE Mini ECOi Multi Split VRF Heat Pump...13 ME 2-Way ECOi VRF Heat Pump...14 Combined ME 2-Way ECOi VRF Heat Pump...16 INDOOR Units....19 MK Wall Mounted...19 Panasonic OUTDOOR Panasonic INDOOR MY Series 4-Way Ceiling Cassette...2 MU Series 4-Way Ceiling Cassette...21 MD Series 1-Way Ceiling Cassette...22 MT Series Ceiling Suspended...23 MP/MR Floor Mounted...24 MM Concealed Duct... MF Concealed Duct...26 ME Concealed Duct...27 Control System....28-31 ACCESSORIES...32 SERVICES...33 IEER Integrated Energy Efficiency Ratio...34 ECOi System Certified Efficiency Ratings...34-35 Company Information....36 Panasonic Control System
We are committed to becoming an indispensable element in the lives of people all over the world. For the Living Inside & Out. Contractors. Building Support. At Panasonic, we realize contractors are looking for turnkey installation and support. ECOi is quite simply the perfect building solution. With its modular design and ease of installation, it s a solution that can grow with any building project. In fact, ECOi may just make you remember why you got into the business in the first place. Engineers. Designing Confidence. ECOi is absolute confidence. Its flexibility allows multiple applications and installation configurations. With a maximum pipe length of up to 984 feet and up to 4 units connected to one outdoor system you can engineer a perfect solution for all your project needs. ECOi is a superior modular option that provides for floor-by-floor commissioning. ECOi Your Building Life Tool. Architects. Design Freedom. Now There s An Idea. Of course, nobody understands this more than the architects who design them. That s why the ECOi HVAC system provides more freedom to meet any design need. With space saving environmentally friendly designs, and ultimate efficiency, you can design your vision first then marry our system fluidly within your plans. Owners & Tenants. With immediate response to changing room capacity heat loads and varying sun exposures throughout the day, everybody stays cool and comfortable. ECOi also ensures individual zone temperature control so each office or room can be adjusted for personalized comfort. ECOi can grow with you. As remodeling occurs and building extensions are planned, ECOi s modularity lets you simply add on to the system. With intelligent controllers, VRF technology and R41A refrigerant, ECOi guarantees continued energy savings and environmental friendship for years to come. ECOi has a number of diverse features to meet all your conditioning needs, including: flexible combinations: ECOi allows multiple indoor unit combinations that provide you with the utmost in flexible solutions. The system also allows multiple unit connectivity providing up to 13% of the total capacity of the condensing unit. This provides for up to 16 indoor units connected to one condensing unit. precisely match the amount of refrigerant being delivered to the needs of each zone. This intelligent approach helps realize excellent efficiencies during partial-load conditions. This allows all occupants to enjoy consistent room temperature, regardless of any increases or decreases in the heat load during the day. ECOi quite simply knows what you need, and when you need it throughout the day. And even better, it does so with energy efficiency in mind. Inverter Control Compressor: All ECOi systems utilize highly advanced inverter controlled compressor technology. By varying the rotational speed of the compressor, the inverter control can 3
New Panasonic Group New Panasonic Group Contributing to the progress and development of society and enriching people s lives through manufacturing Offering wider & more comprehensive solutions for life Panasonic Corporation Panasonic Electric Works Co., Ltd.. Wide range of products, electrical appliances, business systems, residential, BtoB, healthcare. Cutting-edge technologies. Management infrastructures including sales platforms Our extensive range of products delivers customer satisfaction 1 4
Panasonic Group Technology Ideas from consumers viewpoint, ideas that are practical and useful, ideas that bring surprises and discoveries, ideas that make people happy, ideas that are innovative and interesting ideas for life. We Like to Challenge Our Ideas and Products The Panasonic robot-mascot powered by rechargeable EVOLTA batteries completed a two-month-long, 5-kilometer trip from Tokyo to Kyoto. The seven-inch-tall robot, Mr. EVOLTA, weighing just 1 kilogram (standardized metric measurement), is a small green character made of plastic and carbon fiber with two Panasonic rechargeable EVOLTA batteries on its back, pulling a trailer containing ten more EVOLTA batteries. Human team mates helped Mr. EVOLTA by pushing a device with an infra-red signal which the robot followed and by stopping once a day to recharge its batteries. Panasonic set this challenge to demonstrate the performance and durability of its new rechargeable AA batteries made from nickel-metal-hydride. The batteries combine the convenience of a disposable battery with the performance and cost benefits of a rechargeable battery. Two years ago, Mr. EVOLTA, powered by two EVOLTA alkaline batteries, climbed a 53-meter rope to the top of the Grand Canyon in six hours and 46 minutes. The following year, it finished the 24-hour Le Mans endurance race of 23.7km and was subsequently recognized in the Guinness World Records for the longest distance covered by a battery-operated remote control car. U-Vacua Technology Built for Extreme Conditions Panasonic U-Vacua is a high-performance vacuum insulation panel (VIP) with very low thermal conductivity that performs about 2 times better than standard urethane foam. U-Vacua s improved performance saves space while increasing the energy efficiency of refrigeration applications, home appliances, buildings, and any products that require low energy loss from heat transfer. It is powerful enough to make a snowman survive in a hot sauna for 24 hours. We have tested it. Toughbooks are, like the name indicates, perfect companion to conditions that require durability and liability. With a rugged build, they are also the choice for the German skijump team, which uses them in various weather conditions from rain to -2 C temperatures. Connected at 35, Feet Just Like on the Ground Beside being a world leader in state-of-art in-flight entertainment and communication systems manufacturer, Panasonic Avionics has teamed up with Lufthansa to provide passengers with in-flight broadband connectivity on Lufthansa flights. Passengers will be able to use their own devices, such as laptops and smart phones, to wirelessly connect to the Internet to browse, access social media sites, send/receive e-mails and more. 2 5 7
MF 3-WAY ECOi TM VRF Heat Recovery Series Commercial office buildings are subject to fluctuating heat levels generated from electronic office equipment, lighting and varying occupant levels. Also, hotels, nursing homes and other commercial living spaces often have times when occupants will want either heating or cooling at the same time. The heat recovery system offers the perfect solution for stabilizing the air temperature by providing all the features of a heat pump system - and the added flexibility of simultaneous cooling and heating from one refrigerant pipe network. For the buildings requiring simultaneous heating and cooling, Panasonic 3-Way ECOi system provides the perfect solution. LE AND ME 2-WAY ECOi TM VRF Heat PUMP Panasonic s Combined ECOi 2-Way conditioning solution offers superior heating and cooling coupled with cost effective installation. A smart conditioning solution for large capacity jobs. ECOi SERIES Model Code Indoor Unit Outdoor Unit S - 18 M K 1 U6 S - 18 M K 1 U6 1 2 3 4 5 6 1 2 3 4 5 6 1 Model Type 2 Capacity 3 Series 4 Category 5 Development 6 Voltage 7 Special Feature S : Indoor Unit Development L : Mini ECOi INDOOR UNITS Series Nominal in BTU/hr U6 : 28/23V, 6Hz, 1 Phase E : Salt Protection U : Outdoor Unit M : ECOi U : 4 Way Cassette Y : Mini 4 Way Cassette D : 1 Way Cassette K : Wall Mounted S : Wall Mounted (no EEV) T : Ceiling Suspended E : Ducted; High ESP F : Ducted; Med ESP M : Ducted; Low ESP P : Floor Mounted (with Panel) R : Floor Mounted (without Panel) U9 : 28/23V, 6Hz, 3 Phase OUTDOOR UNITS E : Heat Pump F : Heat Recovery 6
MF 3-WAY ECOi TM VRF Heat Recovery Series Excellent performance Panasonic 3-Way multi system is capable of simultaneous heating/cooling and individual operation of each indoor unit by only one outdoor unit. As a result, efficient individual air conditioning is possible in buildings having diverse room temperatures. 3-Way ECO-i MULTI enables simultaneous heating and cooling operation by each solenoid valve kit. Higher energy savings Effective heat recovery system enables higher energy savings The waste heat removed from the cooled room is effectively utilized as a heat source for the room to be heated. As a result, the load on the compressor and heat exchanger on the outdoor unit can be reduced, enabling excellent heat recovery operation. System example Hot Gas Discharge Pipe Improves discharge air temperature of indoor units during heating and simultaneous mode operation. [Stop] MU [] MK [] MF [] MD [] ME [] MT Flexible system design Solenoid Valve Kit CZ-P16HR1U, CZ-P56HR1U Solenoid Valve Kit can be piped up to 98ft. from Indoor Unit This enables flexible installation and system designs. Up to 4 indoor units are capable of simultaneous heating/cooling operation. Liquid pipe medium-temperature, medium-pressure liquid pipe Suction pipe low-temperature, low-pressure gas pipe Discharge pipe high-temperature, high-pressure gas pipe Optional parts Solenoid valve kit CZ-P56HR1U (For 7,5 BTU/H to 19, BTU/H) CZ-P16HR1U (For 19,1 BTU/H to 54,6BTU/H) * For conference rooms and other locations where low noise is required, pay attention to the installation location and install in a corridor etc.
MF 3-WAY ECOi TM VRF Heat Recovery Series U-72MF1U9 / U-72MF1U9E U-96MF1U9 / U-96MF1U9E Panasonic s ECOi Heat Recovery series offers the ability to heat and cool different zones simultaneously. Panasonic was the first manufacturer in the world to develop this energy saving heat recovery solution. Offering all the features of our standard heat pump series, the 3-Way solution can offer even higher energy savings for the building owner. KEY FEATURES: * 3-Way Heat Recovery System. Simultaneous and. * ECO Friendly R41A Refrigerant * One Outdoor Unit Connects As Many As 16 Indoor Units (5%-13% ratio of indoor to outdoor capacity) * U-72MF1U9 includes one inverter driven Rotary compressor * U-96MF1U9 includes one inverter driven Rotary compressor and one AC Constant Speed Scroll Compressor * Nominal Operating Range (Outdoor Ambient) - 14 FDB to 113 FDB - -4 FWB to 59 FWB * Ultra Quiet Operation As Low As 51.5dB(a) * Variable Speed DC Fan Motor (ESP adjustable to.24 wc) * Flexible Piping Design: - 984 Feet - Maximum Total Liquid Line - 492 Feet - Maximum Outdoor To Most Distant Indoor Unit - 164 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Above Indoor) - 131 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Below Indoor) MODELS (Type: Nominal Capacity, Ducted) Nominal Tons Volt PH Connectable Indoor Units (Max.) U-72MF1U9 72, BTU Heat Recovery 6 28-23V/6 HZ 3 12 U-72MF1U9E 72, BTU Heat Recovery With Salt Protection - Special Order 6 28-23V/6 HZ 3 12 U-96MF1U9 95, BTU Heat Recovery 8 28-23V/6 HZ 3 16 U-96MF1U9E 95, BTU Heat Recovery With Salt Protection - Special Order 8 28-23V/6 HZ 3 16 8 * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers
MF 3-WAY ECOi TM VRF Heat Recovery Series DESCRIPTION U-72MF1U9 (E) U-96MF1U9 (E) Performance capacity: BTU/H Power input: kw capacity: BTU/H Power input: kw 72, 5.3 81, 5.79 95, 7.75 16,5 8.6 Panasonic OUTDOOR ELECTRICAL RATINGS Voltage rating Running amperes Running amperes Min. circuit ampacity Max. Overcurrent Protection (MOCP): (A) 28-23 V 15.1-14.2 A 16.5-15.5 A 24 A 4 A 28-23 V 23.2-21.6 A.4-23.7 A 34 A 45 A COMPRESSOR Type - Quantity Motor output Refrigeration Oil Type Refrigeration Oil Charge amount Crankcase heater Refrigerant amount at shipment Refrigerant control Defrost method Heat exchanger CAPACITY CONTROL Inverter Driven Rotary Type 4.1 kw FV68S (Ether oil - PVE) 1.4 gal w R41A -.9 lbs Electronic expansion valve Reverse-cycle, outdoor unit cycle Aluminum plate fin / Copper tube 1-1% Inverter Driven Rotary 1 Fixed Scroll Hermetic (2.7 + 3.5) kw FV68S (Ether oil - PVE) 1.96 gal + 32 w R41A -.9 lbs Electronic expansion valve Reverse-cycle, outdoor unit cycle Aluminum plate fin / Copper tube 8-1% Fan device Type - Quantity Motor output Protective devices CFM EXTERNAL STATIC PRESSURE Propeller fan x 1.7 kw High pressure switch, overcurrent (CT method) 5.3. /.24 WC Propeller fan x 1.7 kw High pressure switch, overcurrent (CT method) 5.65. /.24 WC TUBING Refrigerant tubing Gas tube Refrigerant tubing Liquid tube Ref. Tubing Discharge Tube Refrigerant tubing Balance tube External air temp. Operation range Operation sound (Hi) 3/4" (Brazing) ø3/8" (Brazing) ø5/8" (Brazing) ø3/8" (Flare) : 14 to 113 (DB) / : -4 to 59 (WB) F 54.5 (Quiet mode: 51.5) db-a ø7/8" (Brazing) ø3/8" (Brazing) ø3/4" (Brazing) ø3/8" (Flare) : 14 to 113 (DB) / : -4 to 59 (WB) F 55. (Quiet mode: 52.) db-a UNIT DIMENSIONS Inches (") / lbs. Color (Munsell code) 82.5"/ 35"/ 35"/ 573 lbs. Silky shade (1y 8.5/.5) 82.5"/ 35"/ 35"/ 672 lbs. Silky shade (1y 8.5/.5) (E) indicates with salt protection - Special Order * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers NOTE: Values represent nominal capacities for Ducted combinations. 9
COMBINED MF 3-WAY ECOi TM VRF Heat Recovery Series WU-144MF1U9 / WU-168MF1U9 WU 144 WU 168 WU-216MF1U9 / WU-24MF1U9 WU-264MF1U9 / WU-288MF1U9 WU 216 WU 24 WU 264 WU 288 Panasonic s Combined ECOi 3-Way conditioning solution offers superior heating and cooling coupled with cost effective installation. Providing a single refrigerant pipe network means there s only one penetration into the building and ultimately less piping material required, saving you time and money. A smart conditioning solution for large capacity jobs that require simultaneous heating and cooling. KEY FEATURES: * Three-Way Heat Recovery * Combine 3 outdoor units up to 24 tons * ECO Friendly R41A Refrigerant * 28/23V, 3 Phase, 6Hz * Multiple Compressors For Extra Reliability and Partial Redundancy * Nominal Operating Range (Outdoor Ambient) - 14 FDB to 113 FDB - -4 FWB to 59 FWB * Ultra Quiet Operation As Low As 55dB(a) * Variable Speed DC Fan Motors * Flexible Piping Design: - 984 Feet - Maximum Total Liquid Line - 492 Feet - Maximum Outdoor To Most Distant Indoor Unit - 164 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Above Indoor) - 131 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Below Indoor) WU Heat recovery Combined Series. System Outdoor Unit & Ducted Nominal Tons Power input Control Range Connectable Indoor Units (Max) WU-144MF1U9 U-72MF1U9 (quantity of 2) 139, & 157, BTU/H 12 1.6/ 11.6 kw 6-1% 24 WU-168MF1U9 U-72MF1U9 U-96MF1U9 164, & 184, BTU/H 14 13.1/ 14.4 kw 6-1% 29 WU-216MF1U9 U-72MF1U9 (quantity of 3) 23, & 228, BTU/H 18 15.9/ 17.4 kw 6-1% 37 WU-24MF1U9 U-72MF1U9 (quantity of 2) U-96MF1U9 23, & 265, BTU/H 2 18.4/ 2.2 kw 6-1% 4 WU-264MF1U9 U-96MF1U9 (quantity of 2) U-72MF1U9 8, & 288, BTU/H 22 2.8/ 23. kw 6-1% 4 WU-288MF1U9 WU-96MF1U9 (quantity of 3) 281, & 312, BTU/H 24 23.3/.8 kw 6-1% 4 1 (E) indicates with salt protection - Special Order * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers
COMBINED MF 3-WAY ECOi TM VRF Heat Recovery Series DESCRIPTION WU-144MF1U9 WU-168MF1U9 Performance capacity: BTU/H Power input: kw capacity: BTU/H Power input: kw Mode Nominal Conditions Indoor: F WB/ F DB Outdoor: F DB Pipe Length: Feet Level Difference: Feet Includes (1) U-72MF1U9 and (1) U-72MF1U9 139, 1.6 157, 11.6 8/67 95 Includes (1) U-72MF1U9 and (1) U-96MF1U9 164, 13.1 184, 14.4 8/67 95 Panasonic OUTDOOR Mode Nominal Conditions Indoor: F DB Outdoor: F DB/ F WB Pipe Length: Feet Level Difference: Feet 7 47/43 7 47/43 Nominal Operating Range : F DB : F WB 14 to 113-4 to 59 14 to 113-4 to 59 Compressor Type/Quantity Capacity Control Range: % 2 Inverter driven Twin Rotary 6-1% 2 Inverter driven Twin Rotary & 1 fixed speed scroll 6-1% Fan Type/Quantity Fan Motor Output: (kw) External Static Pressure 1 Propeller (ea).7 kw (ea). /.24 WC 1 Propeller (ea).7 kw (ea). /.24 WC Power Supply V/PH/Hz Minimum Circuits Amps (MCA): (A) Max. Overcurrent Protection (MOCP): (A) 28-23/ 3/ 6 52 8 28-23/ 3/ 6 6 85 Weight: (lbs) 1146 1245 Coil: Coil Face Area:(sq. Ft.) Number of Rows: Protection Devices High Pressure Switch/Overcurrent (CT Method) Crankcase Heaters:(W) 29.5(ea) 4(ea) Yes + 29.5(ea) 4(ea) Yes + + 32 Each outdoor unit requires a separate electrical FUSED DISconnect, see individual outdoor requirements. (E) indicates with salt protection - Special Order * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers NOTE: Values represent nominal capacities for Ducted Indoor Units. 11
COMBINED MF 3-WAY ECOi TM VRF Heat Recovery Series DESCRIPTION WU- 216MF1U9 WU- 24MF1U9 WU- 264MF1U9 WU- 288MF1U9 Performance capacity: BTU/H Power input: kw capacity: BTU/H Power input: kw Mode Nominal Conditions Indoor: F WB/ F DB Outdoor: F DB Pipe Length: Feet Level Difference: Feet Includes (3) U-72MF1U9 23, 15.9 228, 17.4 8/67 95 Includes (2) U- 72MF1U9 and (1) U-72MF1U9 23, 18.4 265, 2.2 8/67 95 Includes (1) U-72MF1U9 and (2) U-96MF1U9 8, 2.8 288, 23. 8/67 95 Includes (3) U-96MF1U9 281, 23.3 312,.8 8/67 95 Mode Nominal Conditions Indoor: F DB Outdoor: F DB/ F WB Pipe Length: Feet Level Difference: Feet 7 47/43 7 47/43 7 47/43 7 47/43 Nominal Operating Range : F DB : F WB 14 to 113-4 to 59 14 to 113-4 to 59 14 to 113-4 to 59 14 to 113-4 to 59 Compressor Type/Quantity Capacity Control Range: % 3 Inverter driven Twin Rotary 6-1% 3 Inverter driven Twin Rotary & 1 fixed speed scroll 6-1% 3 Inverter driven Twin Rotary & 2 fixed speed scroll 6-1% 3 Inverter driven Twin Rotary & 3 fixed speed scroll 6-1% Fan Type/Quantity Fan Motor Output: (kw) External Static Pressure 1 Propeller (ea).7 kw. /.24 WC 1 Propeller (ea).7 kw. /.24 WC 1 Propeller (ea).7 kw. /.24 WC 1 Propeller (ea).7 kw. /.24 WC Power Supply V/PH/Hz Minimum Circuits Amps (MCA): (A) Max. Overcurrent Protection (MOCP): (A) 28-23/ 3/ 6 78 12 28-23/ 3/ 6 86 1 28-23/ 3/ 6 94 13 28-23/ 3/ 6 12 135 Weight: (lbs) 1719 1818 1917 216 Coil: Coil Face Area:(sq. Ft.) Number of Rows: 29.5(ea) 4(ea) 29.5 (ea) 4 29.5 (ea) 4 29.5 (ea) 4 Protection Devices High Pressure Switch/Overcurrent (CT Method) Crankcase Heaters:(W) Yes + + Yes + + + 32 Yes (2 X + 32) + Yes 3 X + 32 12 Each outdoor unit requires a separate electrical FUSED DISconnect, see individual outdoor requirements. (E) indicates with salt protection - Special Order * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers NOTE: Values represent nominal capacities for Ducted Indoor Units.
LE MINI ECOi TM MULTI SPLIT VRF HEAT PUMP Series U-36LE1U6 (E) / U-52LE1U6 (E) Panasonic s Mini ECOi is suited for numerous commercial and premium residential applications. KEY FEATURES: * Single Phase 28/23 volts * One Outdoor Unit Connects As Many As 9 Indoor Units (5%-13% ratio of indoor to outdoor capacity) * Inverter Driven Twin Rotary Compressor * Nominal Operating Range (Outdoor Ambient) - 14 FDB to 113 FDB - -4 FWB to 59 FWB * Ultra Quiet Operation As Low As 48dB(a) * Variable Speed DC Fan Motor * Piping: -656 Feet - Maximum Total Liquid Line -164 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Above Indoor) -131 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Below Indoor) * Defrost control, Reverse cycle, microprocessor control * External finish: Galvanized steel plate with powder paint * Refrigerant control: Electronic expansion valve * Control Range 1-1% Panasonic OUTDOOR DESCRIPTION U-36LE1U6 (E) U-52LE1U6 (E) POWER SOURCE 28-23V/1PH/6Hz 28-23V/1PH/6Hz Performance CAPACITY SEER capacity HSPF Air CIRCULATION (Hi) ELECTRICAL RATINGS Voltage rating AVAILABLE voltage range Running amperes Max. Running amperes Power input Max. Power input Min. circuit ampacity Max. Overcurrent Protection (MOCP) REFRIGERANT TUBING Limit of tubing length Limit of elevation difference Between the 2 units Refrigerant tube diameter Liquid tube in. Gas tube in. UNIT DIMENSIONS Inches (") / lbs. Shipping weigh / volume External air temp. Operation range Ducted Non-Ducted Mix 37, 39, 38, BTU/H 13.1 17. 15. 38,5 43, 4,75 BTU/H 7.8 9.8 8.8 3,53 CFM HEATING 28 / 23 V 28 / 23 V 187 3 V 187 3 V 14.6 / 13.6 A 14.6 / 13.6 A 23.6 / 23.6 A 23.6 / 23.6 A 2.76 / 2.76 Kw 2.88 / 2.88 Kw 4.85 / 4.85 Kw 4.85 / 4.85 Kw 18 A 3 A 656 ft Outdoor unit is higher than indoor unit: 164 Outdoor unit is lower than indoor unit: 131 3/8" 5/8" 49 / 37 / 14 / 229 lbs. 247 lbs. / 19.8 ft. 3 :14 to 113 (DB)/: -4 to 59 (WB) Ducted Non-Ducted Mix 51,5 52, 51,75 BTU/H 14.6 17.4 16. 57,5 58,5 58, BTU/H 7.7 9.6 8.6 3,53 CFM HEATING 28 / 23 V 28 / 23 V 187 3 V 187 3 V 23.5 / 21.9 A 23.5 / 21.9 A 28 / 28 A 28 / 28 A 4.57 / 4.57 Kw 4.58 / 4.58 Kw 5.72 / 5.72 Kw 5.7 2 / 5.72 Kw 29 A 5 A 656 ft Outdoor unit is higher than indoor unit: 164 Outdoor unit is lower than indoor unit: 131 3/8" 3/4" 49 / 37 / 14 / 229 lbs. 247 lbs. / 19.8 ft. 3 :14 to 113 (DB)/: -4 to 59 (WB) Connectable Indoor Units (MaX) 6 9 CERTIFICATION STANDARD AHRI 21 / 24 * NOTE: *(E) in Model # indicates Salt Protection - Special Order 13
ME 2-way ECOi TM VRF HEAT PUMP Series U-72ME1U9 / U-72ME1U9E U-96ME1U9 / U-96ME1U9E Panasonic s ECOi is an all-in-one modular conditioning solution. Suited for numerous commercial and industrial applications it offers flexible installation, superior heating and cooling. KEY FEATURES: * One Outdoor Unit Connects As Many As 16 Indoor Units (5%-13% ratio of indoor to outdoor capacity) * U-72ME1U9 one Inverter Driven Rotary Compressor * U-96ME1U9 includes one Inverter Driven Rotary Compressor and One AC Constant Speed Scroll Compressor * Nominal Operating Range (Outdoor Ambient) - 14 FDB to 113 FDB - -4 FWB to 59 FWB * Ultra Quiet Operation As Low As 52dB(a) * Variable Speed DC Fan Motor (ESP adjustable to.24 wc) * Flexible Piping Design: - 984 Feet - Maximum Total Liquid Line - 492 Feet - Maximum Outdoor To Most Distant Indoor Unit - 164 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Above Indoor) - 131 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Below Indoor) (E) indicates with salt protection - Special Order DESCRIPTION (Type: Nominal Capacity, Ducted) Nominal Tons Volt PH Connectable Indoor Units (Max U-72ME1U9 * 72, BTU Heat Pump 6 28-23V/6 HZ 3 12 U-72ME1U9E * 72, BTU Heat Pump With Salt Protection - Special Order 6 28-23V/6 HZ 3 12 U-96ME1U9 * 95, BTU Heat Pump 8 28-23V/6 HZ 3 16 U-96ME1U9E * 95, BTU Heat Pump With Salt Protection - Special Order 8 28-23V/6 HZ 3 16 14 * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers
ME 2-way ECOi TM VRF HEAT PUMP Series DESCRIPTION U-72ME1U9 (E) U-96ME1U9 (E) Performance capacity: BTU/H Power input: kw capacity: BTU/H Power input: kw 72, 5.28 81, 5.79 95, 7.69 16,5 8.6 Panasonic OUTDOOR ELECTRICAL RATINGS Voltage rating Running amperes Running amperes Min. circuit ampacity Max. Overcurrent Protection (MOCP) 28-23 V 15.1-14.1 A 16.5-15.5 A 26 A 4 A 28-23 V 23. - 21.4 A.4-23.7 b A 34 A 45 A COMPRESSOR Type - Quantity Motor output Refrigeration Oil Type Refrigeration Oil Charge amount Crankcase heater Refrigerant amount at shipment Refrigerant control Defrost method Heat exchanger CAPACITY CONTROL Inverter Driven Twin Rotary Type 4.1 kw FV68S (Ether oil - PVE) 1.4 gal w R41A -.9 lbs Electronic expansion valve Reverse-cycle, outdoor unit cycle Aluminum plate fin / Copper tube 1-1% Inverter Driven Twin Rotary and 1 Fixed Speed Scroll (3 + 3.75) kw FV68S (Ether oil) 1.56 gal + 32 w R41A -.9 lbs Electronic expansion valve Reverse-cycle, outdoor unit cycle Aluminum plate fin / Copper tube 8-1% Fan device Type - Quantity Motor output Protective devices CFM EXTERNAL STATIC PRESSURE Propeller fan x 1.7 kw High pressure switch, overcurrent (CT method) 5.3. /.24 WC Propeller fan x 1.7 kw High pressure switch, overcurrent (CT method) 5.65. /.24 WC TUBING Refrigerant tubing Gas tube Refrigerant tubing Liquid tube Refrigerant tubing Balance tube External air temp. Operation range Operation sound (Hi) 3/4" (Brazing) ø3/8" (Brazing) ø3/8" (Flare) : 14 to 113 (DB) / : -4 to 59 (WB) F 54.5 (Quiet mode: 51.5) db-a 7/8" (Brazing) 3/8" (Brazing) ø3/8" (Flare) : 14 to 113 (DB) / : -4 to 38 (WB) F 55. (Quiet mode: 52.) db-a UNIT DIMENSIONS Inches (") / lbs. Color (Munsell code) 82.5"/ 35"/ 35"/ 584 lbs. Silky shade (1y 8.5/.5) 82.5"/ 35"/ 35"/ 683 lbs. Silky shade (1y 8.5/.5) (E) indicates with salt protection - Special Order * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers NOTE: Values represent nominal capacities for Ducted Indoor Units. 15
COMBINED ME 2-way ECOi TM VRF HEAT PUMP Series WU 144ME WU 168ME WU-144ME1U9 / WU-168ME1U9 WU-216ME1U9 / WU-24ME1U9 WU-264ME1U9 / WU-288ME1U9 ME Combined Series. WU 216ME WU 24ME WU 264ME WU 288ME Panasonic s Combined ECOi outdoor units offer superior heating and cooling coupled with cost effective installation. Providing a single refrigerant pipe network means there s only one penetration into the building and ultimately less piping material required, saving you time and money. A smart conditioning solution for large capacity jobs. KEY FEATURES: * Heat Pump * Combine 3 outdoor units up to 24 tons * Combined Series Allows Up to 4 Indoor Units (5%-13% ratio of indoor to outdoor capacity) * ECO Friendly R41A Refrigerant * 28/23V, 3 Phase, 6Hz * Multiple Compressors For Precise and Efficient Operation * Nominal Operating Range (Outdoor Ambient) - 14 FDB to 113 FDB - -4 FWB to 59 FWB * Ultra Quiet Operation As Low As 51.5dB(a) * Variable Speed DC Fan Motors * Flexible Piping Design: - 984 Feet - Maximum Total Liquid Line - 492 Feet - Maximum Outdoor To Most Distant Indoor Unit - 164 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Above Indoor) - 131 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Below Indoor) System Outdoor Unit & Nominal Tons Power input 28/23 Control Range Connectable Indoor Units (Max) WU-144ME1U9 U-72ME1U9 (quantity of 2) 139, & 157, BTU/H 12 1.56/11.58 kw 6-1% 24 WU-168ME1U9 U-72ME1U9 U-96ME1U9 164, & 184, BTU/H 14 12.97/ 14.39 kw 6-1% 29 WU-216ME1U9 U-72ME1U9 (quantity of 3) 23, & 228, BTU/H 18 15.84/ 17.37 kw 6-1% 37 WU-24ME1U9 U-72ME1U9 (quantity of 2) U-96ME1U9 23, & 265, BTU/H 2 18./ 2.18 kw 6-1% 4 WU-264MEIU9 U-96ME1U9 (quantity of 2) U-72ME1U9 8, & 288, BTU/H 22 2.66/ 22.99 kw 6-1% 4 WU-288ME1U9 U-96ME1U9 (quantity of 3) 281, & 312, BTU/H 24 23.7/.8 kw 6-1% 4 16 (E) indicates with salt protection - Special Order * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers NOTE: Values represent nominal capacities for Ducted Indoor Units.
COMBINED ME 2-way ECOi TM VRF HEAT PUMP Series DESCRIPTION WU-144ME1U9 WU-168ME1U9 Performance capacity: BTU/H Power input: kw capacity: BTU/H Power input: kw Mode Nominal Conditions Indoor: F WB/ F DB Outdoor: F DB Pipe Length: Feet Level Difference: Feet Includes (2) U-72ME1U9 139, 1.56 157, 11.58 8/67 95 Includes (1) U-72ME1U9 and (1) U-96ME1U9 164, 12.97 184, 14.39 8/67 95 Panasonic OUTDOOR Mode Nominal Conditions Indoor: F DB Outdoor: F DB/ F WB Pipe Length: Feet Level Difference: Feet 7 47/43 7 47/43 Nominal Operating Range : F DB : F WB 14 to 113-4 to 59 14 to 113-4 to 59 Compressor Type/Quantity Capacity Control Range: % 2 Inverter driven Twin Rotary 6-1% 2 Inverter driven Twin Rotary & 1 fixed speed scroll 6-1% Fan Type/Quantity Fan Motor Output: (kw) External Static Pressure 1 Propeller (ea).7 kw (ea). /.24 WC 1 Propeller (ea).7 kw (ea). /.24 WC Power Supply V/PH/Hz Minimum Circuits Amps (MCA): (A) Max. Overcurrent Protection (MOCP): (A) 28-23/ 3/ 6 52 8 28-23/ 3/ 6 6 85 Weight: (lbs) 1168 1267 Coil: Coil Face Area:(sq. Ft.) Number of Rows: Protection Devices High Pressure Switch/Overcurrent (CT Method) Crankcase Heaters:(W) 29.5(ea) 4(ea) Yes + 29.5(ea) 4(ea) Yes + + 32 Each outdoor unit requires a separate electrical FUSED DISCONNECT, see individual outdoor requirements. (E) indicates with salt protection - Special Order * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers NOTE: Values represent nominal capacities for Ducted Indoor Units. 17
COMBINED ME 2-way ECOi TM VRF HEAT PUMP Series DESCRIPTION WU-216 WU-24 WU-264 WU-288 Performance capacity: BTU/H Power input: kw capacity: BTU/H Power input: kw Includes (3 )U-72ME1U9 23, 15.84 228, 17.37 Includes (2) U-72ME1U9 and (1) U-96ME1U9 23, 18. 265, 2.18 Includes (1) U-72ME1U9 and (2) U-96ME1U9 8, 2.66 288, 22.99 Includes (3) U-96ME1U9 281, 23.7 312,.8 Mode Nominal Conditions Indoor: F WB/ F DB Outdoor: F DB Pipe Length: Feet Level Difference: Feet 8/67 95 8/67 95 8/67 95 8/67 95 Mode Nominal Conditions Indoor: F DB Outdoor: F DB/ F WB Pipe Length: Feet Level Difference: Feet 7 47/43 7 47/43 7 47/43 7 47/43 Nominal Operating Range : F DB : F WB 14 to 113-4 to 59 14 to 113-4 to 59 14 to 113-4 to 59 14 to 113-4 to 59 Compressor Type/Quantity Capacity Control Range: % 3 Inverter driven Twin Rotary 6-1% 3 Inverter driven Twin Rotary & 1 fixed speed scroll 6-1% 3 Inverter driven Twin Rotary & 2 fixed speed scroll 6-1% 3 Inverter driven Twin Rotary & 3 fixed speed scroll 6-1% Fan Type/Quantity Fan Motor Output: (kw) External Static Pressure 1 Propeller (ea).7 kw (ea). /.24 WC 1 Propeller (ea).7 kw (ea). /.24 WC 1 Propeller (ea).7 kw (ea). /.24 WC 1 Propeller.7 kw. /.24 WC Power Supply V/PH/Hz Minimum Circuits Amps (MCA): (A) Max. Overcurrent Protection (MOCP): (A) 28-23/ 3/ 6 78 12 28-23/ 3/ 6 86 1 28-23/ 3/ 6 94 13 28-23/ 3/ 6 12 135 Weight: (lbs) 1752 1851 195 249 Coil: Coil Face Area:(sq. Ft.) Number of Rows: 29.5(ea) 4(ea) 29.5(ea) 4(ea) 29.5(ea) 4(ea) 29.5(ea) 4(ea) Protection Devices High Pressure Switch/Overcurrent (CT Method) Crankcase Heaters:(W) Yes + + Yes + + + 32 Yes (2 X + 32) + Yes 3 X + 32 Each outdoor unit requires a separate electrical FUSED DISCONNECT, see individual outdoor requirements. 18 (E) indicates with salt protection - Special Order * NOTE: *46 Volt Step Down Transformers (46-23) available for 6 and 8 ton condensers NOTE: Values represent nominal capacities for Ducted Indoor Units.
MK WALL MOUNTED UNIT S-7MK1U6 / S-9MK1U6 / S-12MK1U6 / S-18MK1U6 S-19MS1U6 / S-24MK1U6 Panasonic s wall-mounted units work well with any interior design. Flexible and compact, offering individualized zoned comfort for complete temperature control throughout the day. Over five different air flow directions and wireless remotes provide control in the palm of your hand. KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * Easy Wall Mount for Any Application * Washable Long Life Filter * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control * Light Weight, Only 31 lbs. (S-24MK1U6 is 46 lbs.) * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed control * Easy Service MODELS (Type: Nominal Capacity, etc) Volt PH S-7MK1U6 75 BTU 28-23V/6 HZ 1 S-9MK1U6 96 BTU 28-23V/6 HZ 1 S-12MK1U6 12 BTU 28-23V/6 HZ 1 S-18MK1U6 18 BTU 28-23V/6 HZ 1 S-19MS1U6 19 BTU (special order) 28-23V/6 HZ 1 S-24MK1U6 BTU 28-23V/6 HZ 1 CZ-P56SVK1U External EEV (required for use with S-19MS1U6) N/A N/A Panasonic INDOOR DESCRIPTION S-7MK1U6 S-9MK1U6 S-12MK1U6 S-18MK1U6 S-19MS1U6 needs CZ-P56SVK1U S-24MK1U6 Performance CAPACITY capacity 7,5 BTU/H 8,5 BTU/H 9,6 BTU/H 11, BTU/H 12, BTU/H 14, BTU/H 18, BTU/H 2, BTU/H 19, BTU/H 21, BTU/H, BTU/H 27, BTU/H Current.2/.21 A.2/.21 A.2/.21 A.2/.21 A.2/.21 A.2/.21 A.3/.32 A.3/.32 A.3/.32 A.3/.32 A.37/.39 A.38/.32 A Power Input 5/56 W 5/56 W 5/56 W 5/56 W 5/56 W 5/56 W 61/72 W 61/72 W 61/72 W 61/72 W 72/83 W 72/83 W Heat Exchanger Fan TYPE X QUANTITY Fan AIRFLOW RATE CFM-(H/M/L) FAN Motor TYPE FAN Motor OUTPUT Cross Flow X1 35/28/21 AC 3 w Cross Flow X1 35/28/21 AC 3 w Cross Flow X1 35/28/21 AC 3 w Cross Flow X1 565/495/353 AC 3 w Cross Flow X1 565/495/353 AC 3 w Cross Flow X1 565/495/35 AC 3 w Refrigerant Pipe Dimensions LOW PRESSURE (FLARE) HIGH PRESSURE (FLARE) 3/8" 5/8" UNIT DIMENSIONS Inches (") / lbs. 11.5"/ 39.5"/ 8"/ 31 LBS. 13"/ 45"/ 9"/ 46 LBS. Drainpipe Dimension 3/4" OD Sound Levels (LOW-MED-HIGH) db(a) @ 23V 28/32/36 28/32/36 28/32/36 35/38/42 35/38/42 35/38/42 19
MY series 4-way ceiling cassette 23" x 23" with condensate pump S-12MY1U6 / S-18MY1U6 Panasonic s 4-Way semi-concealed ceiling units are flexible, efficient and space-saving. Now available to fit within standard 24"x24"ceiling grids. KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * Four Way Air Throw * Washable Long Life Air Filter * Built-In Drain Pump Inch Lift * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control * A Low Profile Unit Perfectly Suited for Compact Ceiling Voids (as little as 12-14 inches) * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed control * Easy Service * Optional Outside Air Intake System/model Components (Type: Nominal Capacity, etc) Volt PH S-12MY1U6 S-18MY1U6 System 12 BTU 4-Way Ceiling cassette " x " (includes grille) 28-23V/1ø/6 HZ 1 S-12MY1U6 cassette 28-23V/1ø/6 HZ 1 CZ-18KPY1U grille System 18 BTU 4-way Ceiling cassette " x " (includes grille) 28-23V/1ø/6 HZ 1 S-18MY1U9 cassette 28-23V/1ø/6 HZ 1 CZ-18KPY1U grille DESCRIPTION S-12MY1U6 Performance CAPACITY capacity Current Power Input Heat Exchanger Fan TYPE X QUANTITY Fan AIRFLOW RATE CFM-(H/M/L) FAN Motor TYPE FAN Motor OUTPUT 12, BTU/H 14, BTU/H.22/.2 A.19/.17 A 38/43 W 3/35 W Turbo X1 32/28/ DC 2 w S-18MY1U6 19, BTU/H 21, BTU/H.3/.32 A.27/.3 A 52/56 W 48/47 W Turbo X1 44/37/32 DC 2 w Refrigerant Pipe Dimensions LOW PRESSURE (FLARE) HIGH PRESSURE (FLARE) UNIT DIMENSIONS Inches (") / lbs. Drainpipe Dimension 12.5"/ 23"/ 23"/ 41 lbs. 1 OD Sound Levels (LOW-MED-HIGH) db(a) @ 23V 27/29/31 33/37/41 4-way air discharge " x " system (Includes grille) 2
MU series 4-way ceiling cassette 33" x 33" with condensate pump S-24MU1U6 / S-36MU1U6 Panasonic s 4-Way semi-concealed ceiling units are flexible, efficient and space-saving. Two sides can be adjusted simply to accommodate corner airflow. KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * Four Way Air Throw * Washable Long Life Air Filter * Built-In Drain Pump Inch Lift * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control * A Low Profile Unit Perfectly Suited for Compact Ceiling Voids (as little as 12-14 inches) * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed control * Easy Service * Branch Duct Available * Optional Outside Air Intake System/model Components (Type: Nominal Capacity, etc) Volt PH S-24MU1U6 S-36MU1U6 System BTU 4-Way Ceiling cassette 37- x 37- (includes grille) 28-23V/6 HZ 1 S-24MU1U6 cassette 28-23V/6 HZ 1 CZ-36KPU2U grille System 36 BTU 4-Way Ceiling cassette 37- x 37- (includes grille) 28-23V/6 HZ 1 S-36MU1U6 cassette 28-23V/6 HZ 1 CZ-36KPU2U grille Panasonic INDOOR DESCRIPTION S-24MU1U6 Performance CAPACITY capacity Current Power Input Heat Exchanger Fan TYPE X QUANTITY Fan AIRFLOW RATE CFM-(H/M/L) FAN Motor TYPE FAN Motor OUTPUT, BTU/H 27, BTU/H.29/.26 A.3/.31 A 38/4 W 33/33 W Turbo X1 75/565/495 DC 5 w S-36MU1U6 36, BTU/H 39, BTU/H.51/.46 A.54/.49 A 74/79 W 76/76 W Turbo X1 99/81/74 DC 9 w Refrigerant Pipe Dimensions LOW PRESSURE (FLARE) HIGH PRESSURE (FLARE) UNIT DIMENSIONS Inches (") / lbs. Drainpipe Dimension 3/8" 5/8" 12"/ 33"/ 33"/ 58 lbs. 1 1/4 "OD Sound Levels (LOW-MED-HIGH) db(a) @ 23V 28/31/34 33/36/39 3/8" 5/8" 12" / 33" / 33" / 58 LBS. Height/WIDTH/DEPTH/NET WEIGHT 21
MD series ONE way ceiling cassette with condensate pump S-7MD1U6 / S-9MD1U6 / S-12MD1U6 Panasonic s semi-concealed ceiling units are flexible and space-saving. A perfect conditioning solution for small spaces. Barely visible, the unit blends with any interior design. Powerful enough to cool and comfort those inside. KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * One-Way Air Throw Perfect for Small Spaces * Washable Long Life Air Filter * Built-In Drain Pump 24 Inch Lift * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control *Only 13 Inches Tall (Not Including Decorative Panel), 3 Inches Wide and Inches Deep * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed control * Optional Outside Air Intake * Easy Service System/model Components (Type: Nominal Capacity, etc) Volt PH System 75 BTU 1-Way Ceiling cassette (includes grille) 28-23V/6 HZ 1 S-7MD1U6 S-7MD1U6 cassette 28-23V/6 HZ 1 CZ-12KPD1U grille System 9 BTU 1-Way Ceiling cassette (includes grille) 28-23V/6 HZ 1 S-9MD1U6 S-9MD1U6 cassette 28-23V/6 HZ 1 CZ-12KPD1U grille System 12 BTU 1-Way Ceiling cassette (includes grille) 28-23V/6 HZ 1 S-12MD1U6 S-12MD1U6 cassette 28-23V/6 HZ 1 CZ-12KPD1U grille 22 DESCRIPTION S-7MD1U6 S-9MD1U6 S-12MD1U6 Performance CAPACITY capacity Current Power Input Heat Exchanger Fan TYPE X QUANTITY Fan AIRFLOW RATE CFM-(H/M/L) Fan Ext. STATIC PRESS (23V) FAN Motor TYPE FAN Motor OUTPUT Refrigerant Pipe Dimensions LOW PRESSURE (FLARE) HIGH PRESSURE (FLARE) UNIT DIMENSIONS Inches (") / lbs. Drainpipe Dimension 7,5 BTU/H 8,5 BTU/H.29/.28 A.28/.26 A 48/5 W 44/46 W Centrifugal X1 282/247/212 In. WC DC 6 w 9,6 BTU/H 11, BTU/H.29/.28 A.28/.26 A 48/5 W 44/46 W Centrifugal X1 282/247/212 In. WC DC 6 w 12, BTU/H 14, BTU/H.32/.31 A.34/.32 A 52/55 W 5/52 W Centrifugal X1 32/28/ In. WC DC 6 w 13"/ 3"/ 24.5"/ 43 lbs. 1 OD Sound Levels (LOW-MED-HIGH) db(a) @ 23V 29/31/33
MT series CEILING SUSPENDED UNIT S-12MT1U6 / S-18MT1U6 / S-24MT1U6 Panasonic's ceiling suspended units are an ideal solution to any medium to light commercial application need. Well suited for retail stores, schools, and restaurant applications. These units utilize large supply air openings to provide comfortable airflow and ultra quiet operation. KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * Low Profile Design Fits Into Numerous Ceiling Suspended Locations * One Way Air Discharge with Vanes and Auto Louvre for Efficient Air Distribution * Washable Long Life Air Filter * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control * Less Than 9 Inches Tall and Less than 36 Inches Wide (47 Inches Wide For S-24MT1U6) * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed control * Easy Service Panasonic INDOOR MODELS (Type: Nominal Capacity, etc) Volt PH S-12MT1U6 12, BTU 28-23V/6 HZ 1 S-18MT1U6 18, BTU 28-23V/6 HZ 1 S-24MT1U6 24, BTU 28-23V/6 HZ 1 DESCRIPTION S-12MT1U6 S-18MT1U6 S-24MT1U6 Capacity 12, BTU 14, BTU 19, BTU 21, BTU, BTU 27, BTU Current.14/.17 A.14/.15 A.15/.14 A.15/.17 A.34/.31 A.34/.36 A Power Input 15/16 W 15/16 W 16/16 W 16/18 W 38/37 W 4/4 W UNIT DIMENSIONS Inches (") / lbs. 8.5"/ 36"/ 27"/ 46 lbs. 8.5"/ 46.5"/ 27"/ 55 lbs. Heat Exchanger Fan Type X Quantity Fan AIRFLOW RATE CFM-(H/M/L) Fan Motor Type Fan Motor Output Centrifugal X1 45/39/32 DC 6 - w Centrifugal X1 45/39/32 DC 6 - w Centrifugal X1 653/53/495 DC 6 - w Refrigerant Pipe Dimensions Low Pressure (Flare) High Pressure (Flare) 3/8" 5/8" Drainpipe Dimension 1" OD 1" OD 1" OD Sound Levels (Low-Med-High) 3/32/35 - db(a) @ 23V 3/33/36 - db(a) @ 23V 33/36/38 - db(a) @ 23V 23
MP/MR FLOOR MOUNTED SERIES S-7MP1U6 / S-9MP1U6 / S-12MP1U6 S-15MP1U6 / S-18MP1U6 / S-24MP1U6 FLOOR MOUNTED WITH DECORATIVE PANEL KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed Control * Easy Service * Washable Long Life filter S-7MR1U6 / S-9MR1U6 / S-12MR1U6 S-15MR1U6 / S-18MR1U6 / S-24MR1U6 FLOOR MOUNTED WITHOUT DECORATIVE PANEL KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed Control * Easy Service * Washable Long Life filter DESCRIPTION S-7MP1U6 / S-7MR1U6 S-9MP1U6 / S-9MR1U6 S-12MP1U6 / S12MR1U6 S-15MP1U6 / S15MR1U6 S-18MP1U6 / S18MR1U6 S-24MP1U6 / S-24MR1U6 Capacity 7,5 BTU 8,5 BTU 9.6 BTU 11, BTU 12, BTU 14, BTU 15, BTU 17, BTU 19, BTU 21,, BTU 24, BTU 27, BTU Current.22/.24 A.22/.23 A.22/.24 A.22/.23 A.42/.44.4/.42.58/.6.53/.55.58/.6.53/.55.61/.63.56/.58 Power Input 45/54 W 43-5 W 45/54 W 43-5 W 86/11 83/96 116/134 16/122 116/134 16/122 119/138 19/1 FHX UNIT DIMENSIONS Inches (") / lbs. 24."/42"/9"/64 lbs. HT / W / D / NT WT 24.2"/42"/9"/64 lbs. HT / W / D / NT WT 24.2"/42"/9"/64 lbs. HT / W / D / NT WT 24."/54.5"/9"/86 lbs. HT / W / D / NT WT 24."/54.5"/9"/86 lbs. HT / W / D / NT WT 24."/54.5"/9"/86 lbs. HT / W / D / NT WT FMHX UNIT DIMENSIONS Inches (") / lbs. 24."/35.5"/9"/46 lbs. HT / W / D / NT WT 24."/35.5"/9"/46 lbs. HT / W / D / NT WT 24."/35.5"/9"/46 lbs. HT / W / D / NT WT 24."/48"/9"/62 lbs. HT / W / D / NT WT 24."/48"/9"/62 lbs. HT / W / D / NT WT 24."/48"/9"/62 lbs. HT / W / D / NT WT Heat Exchanger Fan Type X Quantity Fan Airflow Rate CFM-(H/M/L) Fan Motor Output Centrifugal 247/212/177 1 W Centrifugal 247/212/177 1 W Centrifugal 318/247/212 2 W Centrifugal 424/318/283 2 W Centrifugal 53/459/389 3 W Centrifugal 61/495/424 6 W Refrigerant Pipe Dimensions Low Pressure (Flare) High Pressure (Flare) 3/8" 5/8" Drainpipe Dimension 1 OD 1 OD 1 OD 1 OD 1 OD 1 OD Sound Levels (Low-Med-High) 28/3/33 28/3/33 29/35/39 31/35/38 31/36/39 35/38/41 24
MM CONCEALED DUCT LOW PROFILE WITH CONDENSATE PUMP SERIES S-7MM1U6 / S-9MM1U6 / S-12MM1U6 / S-15MM1U6 / S-18MM1U6 8 inches high - Low Profile fits into tight ceiling spaces. "Panasonic's MM units are ideal for drop ceiling applications including apartments, condominiums, and hotel rooms. Compact design permits installation within conditioned space." KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control * Adjustable External Static Pressure * Built-In Drain Pump 2 Inch Lift * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed Control * Bottom or Rear Return Air * Easy Service * 8 inches high" * Low Profile fits into tight ceiling spaces * Optional Outside Air Intake * Washable Long Life Filter MODELS (Type: Nominal Capacity, etc) Volt PH S-7MM1U6 75 BTU ESP =.4 /.12 28-23V/6 HZ 1 S-9MM1U6 96 BTU ESP =.6 /.12 28-23V/6 HZ 1 S-12MM1U6 12 BTU ESP =.6 /.16 28-23V/6 HZ 1 S-15MM1U6 15 BTU ESP =.6 /.16 28-23V/6 HZ 1 S-18MM1U6 19 BTU ESP =.6 /.16 28-23V/6 HZ 1 Panasonic INDOOR DESCRIPTION S-7MM1U6 S-9MM1U6 S-12MM1U6 S-15MM1U6 S-18MM1U6 Performance CAPACITY capacity Current Power Input Heat Exchanger Fan TYPE Fan AIRFLOW RATE CFM-(H/M/L) Fan Ext. STATIC PRESS (23V) FAN Motor TYPE FAN Motor OUTPUT 7,5 BTU/H 8,5 BTU/H.22/.21 A.23/.22 A 32/3 W 32/3 W Centrifugal 212 / 247 / 283.4 /.12 In. WC DC 5 w 9,6 BTU/H 11, BTU/H.26/. A.28/.28 A 35/37 W 37/4 W Centrifugal 23 / 265 / 3.6 /.12 In. WC DC 5 w 12, BTU/H 14, BTU/H.28/.26 A.3/.37 A 37/39 W 39/4 W Centrifugal 247 / 283 / 318.6 /.16 In. WC DC 5 w 15, BTU/H 17, BTU/H.34/.33 A.36/.35 A 44/46 W 47/49 W Centrifugal 283 / 336 / 371.6 /.16 In. WC DC 5 w 19, BTU/H 21, BTU/H.47/.43 A.51/.47 A 59/61 W 63/64 W Centrifugal 353 / 46 / 442.6 /.16 In. WC DC 5 w Refrigerant Pipe Dimensions LOW PRESSURE (FLARE) HIGH PRESSURE (FLARE) UNIT DIMENSIONS Inches (") / lbs. 7 7/8", 29 17/32", 13/64", 42 LBS Drainpipe Dimension 1 OD Sound Levels (LOW-MED-HIGH) db(a) @ 23V /27/28 27/29/3 28 / 3 / 32 3 / 32 / 34 31 / 33 / 35
DESCRIPTION S-7MF1U6 S-9MF1U6 S-12MF1U6 S-15MF1U6 S-18MF1U6 S-24MF1U6 S-36MF1U6 S-48MF1U6 S-54MF1U6 Performance CAPACITY capacity Current Power Input MF CONCEALED DUCT MEDIUM STATIC SERIES Panasonic s concealed ceiling units are compact and space saving with advanced zoning capabilities and efficient design. A perfect conditioning solution for shorter duct runs. 7,5 BTU/H 8,5 BTU/H.45/.49 A.42/.46 A 92/112 W 87/14 W 9,6 BTU/H 11, BTU/H.45/.49 A.42/.46 A 92/112 W 87/14 W 12, BTU/H 14, BTU/H.52/.55 A.49/.54 A 17/1 W 1/122 W S-7MF1U6 / S-9MF1U6 / S-12MF1U6 S-15MF1U6 / S-18MF1U6 / S-24MF1U6 S-36MF1U6 / S-48MF1U6 / S-54MF1U6 KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * Includes 8" round duct connections (two 8" duct collars for 7-15, BTU units three 8" duct collars for 18-24, BTU unit and four 8" duct collars for 36-54, BTUs units) can be removed for plenum ducting. * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control * Adjustable External Static Pressure * Built-In Drain Pump 2 Inch Lift * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed Control * Bottom or Rear Return Air * Easy Service * Optional Outside Air Intake MODELS (Type: Nominal Capacity, etc) Volt PH S-7MF1U6 75 BTU.28 /.4 ESP 28-23V/6 HZ 1 S-9MF1U6 96 BTU.28 /.4 ESP 28-23V/6 HZ 1 S-12MF1U6 12 BTU.28 /.4 ESP 28-23V/6 HZ 1 S-15MF1U6 15 BTU.28 /.44 ESP 28-23V/6 HZ 1 S-18MF1U6 19 BTU.32 /.48 ESP 28-23V/6 HZ 1 S-24MF1U6 BTU.32 /.48 ESP 28-23V/6 HZ 1 S-36MF1U6 36 BTU.32 /.49 ESP 28-23V/6 HZ 1 S-48MF1U6 48 BTU.31 /.45 ESP 28-23V/6 HZ 1 S-54MF1U6 546 BTU.31 /.45 ESP 28-23V/6 HZ 1 15, BTU/H 17, BTU/H.52/.55 A.49/.54 A 17/1 W 1/122 W 19, BTU/H 21, BTU/H.9/.96 A.89/.95 A 183/219 W 182/214 W, BTU/H 27, BTU/H.9/.96 A.89/.95 A 183/219 W 182/214 W 36, BTU/H 39, BTU/H 1.15/1. A 1.1/1.18 A 235/282 W 224/267 W 47,8 BTU/H 54,6 BTU/H 1./1.34 A 1.13/12 A 4/31 W 23/271 W 54,6 BTU/H 61,4 BTU/H 1./1.34 A 1.13/12 A 4/31 W 23/271 W Heat Exchanger FAN TYPE FAN AIRFLOW RATE CFM-(H/M/L) FAN Ext. STATIC PRESS (23V) FAN Motor TYPE FAN Motor OUTPUT Centrifugal x1 353/3/247.4 In. WC AC 5 w Centrifugal x1 353/3/247.4 In. WC AC 5 w Centrifugal x1 424/371/318.4 In. WC AC 7 w Centrifugal x1 424/371/318.44 In. WC AC 7 w Centrifugal x1 671/565/459.48 In. WC AC 1 w Centrifugal x1 671/565/459.48 In. WC AC 1 w Centrifugal x1 16/919/742.49 In. WC AC 14 w Centrifugal x1 1166/16/883.45 In. WC AC 14 w Centrifugal x1 1166/16/883.45 In. WC AC 14 w Refrigerant Pipe Dimensions Low PRESSURE (FLARE) HIGH PRESSURE (FLARE) 3/8" 5/8" 3/8" 5/8" 3/8" 5/8" 3/8" 5/8" UNIT DIMENSIONS Inches (") / lbs. 12.5"/ 27.5"/ "/ 53 lbs. 12.5"/ 39.5"/ "/ 71 lbs. 12.5"/58.5"/ " 14 lbs. 26 Drainpipe Dimension Sound Levels (LOW-MED-HIGH) db(a) @ 23V 1 OD 24/28/31 24/28/31 24/28/31 26/3/33 27/32/36 27/32/36 31/33/38 33/37/4 33/37/4
ME CONCEALED DUCT MEDIUM-HIGH STATIC SERIES S-36ME1U6 / S-48ME1U9 Panasonic s concealed ceiling units are flexible and space saving, helping maximize floor and wall space. Advanced zoning capabilities condition large areas simply and efficiently. Completely concealed, they offer simple installation. KEY FEATURES: * ECO Friendly R41A Refrigerant * 28/23V, 1 Phase, 6Hz * Electronic Expansion Valve (EEV) for Accurate Refrigerant Control * Perfect for Long Duct Runs * Wired or Wireless Remote Control * Automatic or Fixed Fan Speed Control * Easy Service * Built-in float safety A perfect application for longer duct run installations. Panasonic INDOOR MODELS (Type: Nominal Capacity, etc) Volt PH S-36ME1U6 36, BTU ESP =.7" 28-23V/6 HZ 1 S-48ME1U6 48, BTU ESP =.67" 28-23V/6 HZ 1 DESCRIPTION S-36ME1U6 S-48ME1U6 Capacity Current Power Input UNIT DIMENSIONS Inches (") / lbs. Heat Exchanger Fan Type X Quantity Fan AIRFLOW RATE CFM-(H/M/L) Fan Ext. Static Press (23V) Fan Motor Type Fan Motor Output Refrigerant Pipe Dimensions Low Pressure (Flare) High Pressure (Flare) 36, BTU 39, BTU 2.84/2.89 A 2.74/2.8 A 548/62 W 528/62 W 16.5"/ 42"/ 24.5"/ 11 lbs. CENTRIFUGAL X1 1,6/988/883.7 - In. WC AC 2 - W 3/8" 5/8" 47,8 BTU 54,6 BTU 3.24/3.19 A 3.17/3.42 A 644/695 W 627/756 W 18"/ 42"/ 24.5"/ 119 lbs. CENTRIFUGAL X1 1,272/1,237/1,16.67 - In. WC AC 4 - W 3/8" 5/8" Drainpipe Dimension 1 OD 1 OD Sound Levels (Low-Med-High) 42/44/45 - db(a) @ 23V 44/46/47 - db(a) @ 23V 27
CONTROL SYSTEMS SIMPLE SYSTEM CONTROL NETWORK S-NET Panasonic s system control network is the heart and soul of the ECOi unit, enabling it to live with the living inside. With a simple two-wire loop installation, we put control in your hands, literally. No outside specialists required, it s an all-in-one solution for you, and a way to further build profits by keeping installation in-house. The logic resides in the ECOi system and the control is the gateway. CZ-RTC2 / CZ-RWSC1U / CZ-RWSU1U CZ-RWST1U / CZ-RWSY1U CZ-RWSK1U / CZ-RE2C2 / CZ-64ESMC1U CZ-ESWC2 / CZ-6ESMC1U / CZ-CFUNC1U CZ-CSRC2 / CZ-CLNC1U / BMS-CTRL1 CZ-CSWKC1U / CZ-CSWAC1U / CZ-CSWGC1U CZ-CSWBC1U / CZ-CSWWC1U No outside specialists required, it s an all-in-one solution for you. PART NUMBER CZ-RTC2 CZ-RWSC1U CZ-RWSU1U CZ-RWST1U CZ-RWSY1U CZ-RWSK1U CZ-RELC2 CZ-RE2C2 CZ-64ESMC1U CZ-ESWC2 CZ-6ESMC1U CZ-CFUNC1U CZ-CSRC2 CZ-CLNC1U BMS-CTRL1 CZ-CSWKC1U CZ-CSWAC1U CZ-CSWGC1U CZ-CSWBC1U CZ-CSWWC1U DESCRIPTION WIRED REMOTE CONTROLLER 7- day setback, mode, temp, service, etc. WIRELESS REMOTE CONTROLLER For use with MF, MM, ME, MP and MR models WIRELESS REMOTE CONTROLLER For use with MU models WIRELESS REMOTE CONTROLLER For use with MD and MT models WIRELESS REMOTE CONTROLLER For use with MY models WIRELESS REMOTE CONTROLLER For use with MK models SIMPLE REMOTE CONTROLLER with Back Light SIMPLE REMOTE CONTROLLER (wired) on/off, Mode, Temp, Fan Speed, Flap, Service Function SYSTEM CONTROLLER Set individual indoor unit temps for up to 4 zones, 16 indoor units max per zone SCHEDULE TIMER Thermal On/Off at program times only, no set back temperature INTELLIGENT CONTROLLER ( Web Enabled ) Controls Max of 6 indoor units with CZ-CFUNC1U COMMUNICATIONS ADAPTOR Used with INTELLIGENT CONTROLLER and BMS interface REMOTE SENSOR LONWORKS INTERFACE Maximum of 16 indoor units BMS INTERFACE BACnet, LONworks, N2 or MODBUS (also requires CZ-CFUNC1U) P-AIMS Base Software Package P-AIMS Electrical Power Distribution Proportioning Software (also requires CZ-CFUNC1U) P-AIMS Layout Graphic Display Software (also requires CZ-CFUNC1U) P-AIMS BACnet Interface Software (also requires CZ-CFUNC1U) P-AIMS Web Enabling Software (also requires CZ-CFUNC1U) 28
CONTROL SYSTEMS SIMPLE SYSTEM CONTROL NETWORK Wireless Remotes Control In The Palm Of Your Hand. CZ-RWSU1U For Use With MU Indoor Units CZ-RWSY1U For Use With MY Series They enable the user to truly take control of the entire system, from mode, temperature, airflow, and system diagnosis, all through an easy-to-read liquid crystal display. Control at your fingertips. CZ-RWST1U For Use With MD and MT Indoor Units CZ-RWSC1U For Use With MM, MF, ME, MP and MR Indoor Units CZ-RWSK1U For Use With MK Indoor Units KEY FEATURES: * Thin and Easy To Read * Simple To Install and Use * Can Be Adapted for Use On All ECOi Indoor Units * Fan Speed Control * Timer Mode Start/Stop * Timer Mode On/Off * Operating Mode * Inspection/Test Indication * Remote Can Be Configured To Sense Temperature Panasonic s wireless remotes control more than comfort. Simple remotes offer control where minimal functionality is best suited for those inside. Panasonic s Standard Remote with 7-Day Timer is perfectly suited for those requiring more programmed management over multiple zones. By offering immediate diagnostics and up to six-daily set temperature schedules, it s a perfectly controlled solution offering intuitive simplicity. Wired Remotes Simple To Install KEY FEATURES (STANDARD REMOTE/7 DAY TIMER): * Thin and Easy To Read * Simple To Install and Use * Can Be Adapted for Use On All ECOi Indoor Units * Fan Speed Control: Including Automatic or Fixed * Airflow Direction * Operating Mode (//Auto/Dry/Fan) * Vacation Mode for Continued Energy Efficiencies * Full 7-Day Set-Back Functionality, With Up To 6 Time Periods/Day * Full System Diagnostic Capability (Diagnostic History Provides Immediate View of System Past and Present. Panasonic Control System CZ-RELC2 Simple Remote Controller with Back Light CZ-RE2C2 Simple Remote Controller CZ-RTC2 Standard Remote/7-Day Timer For Use With All Indoor Units Panasonic s wired remote controls offer multiple conditioning solutions to meet the needs of any project. KEY FEATURES: (SIMPLE REMOTE) * Thin and Easy To Read * Simple To Install and Use * Can Be Adapted for Use On All ECOi Indoor Units * Operating Mode (//Auto/Dry/Fan) * Vacation Mode for Continued Energy Efficiencies (CZ-RE2C2 & CZ-RTC2 only) * Fan Speed Control: Including Automatic or Fixed * Set Temperature * On/Off * Airflow Direction * Perfectly Suited for Applications Where Simpler Functionality is Required (ie: Hotel Rooms, Nursing Homes, Offices) 29
CONTROL SYSTEMS SIMPLE SYSTEM CONTROL NETWORK Multiple Zone Controllers The heart and soul of conditioning. KEY FEATURES (SYSTEM CONTROL): * Controls Up To 64 Units Into 4 Individualized Zones * Alarm and Operational Signal Output * Single Access Points for All Connected Wired Remotes * System Control Timer Available CZ-64ESMC1U System Controller Controls Up To 64 Units Into 4 Individualized Zones Panasonic s system and intelligent controls are the central nervous system to the conditioning system. The gateway to all data, temperature and system diagnostics. Controls Up To 6 Indoor Units CZ-6ESMC1U Intelligent Controller Web Accessible/Real Time Diagnostics Through Individual IP Address KEY FEATURES (INTELLIGENT CONTROL): * 6.5 Inch Touch Screen Panel * Controls up to 6 Indoor units with added Communication Adapter (128 indoors without) * New Control Wiring System (S Net) Connects Up To 64 Units To a Single Control Line * Offers a Maximum Installation of Two System Controls (One Main, One Sub) * Provides Individual Tenant Billing data for 3 systems addition systems are done by adding Communication Adapters. Requires watt hour meters * Provides Individual Tenant Billing Data Through Calculations Based on a Per-Tenant Basis * Individual Zone Override Feature (High/Low Setting) * Web Accessible/Real Time Diagnostics Through Individual IP Address * Diagnostic History of System Past and Present 3
CONTROL SYSTEMS BUILDING MANAGEMENT INTEGRATION CZ-CLNC1U LonWorks Interface Panasonic s LonWorks interface integrates into many compatible Building Management Systems. Single point of control. Access to all of the ECOi conditioning mechanics. LonWorks Interface Single point of control KEY FEATURES: * Communicate With LonWorks Compatible Systems * Start/Stop * Controls Up To 16 Groups (Maximum 64 Indoor Units) * For 17 or more groups of indoor units connect additional interface units. * Temperature Setting, Fan Speed, etc. * Schedule Time Setting * Alarm Notification BMS-CTRL1 BacNet Interface Panasonic s BMS Controller sets a new standard for multiple equipment protocol conversion. BMS CONTROLLER BMS-CTRL1 KEY FEATURES: Network Diagram * Able to provide BMS integration to a variety of BMS protocols including BACnet, Modbus, LonWorks and N2 * Communicates with up to 9 indoor units and 1 Refrigerent Circuits (note; N2 can communicate with 4 indoor and 1 outdoor units) * Provides control of operating mode, fan, set temperature * Provides status of operating modes and alarm status Panasonic Control System Building Automation System BACnet LonWorks Modbus N2 BMS-CTRL1 (Up to 1 outdoor units & 9 indoor units) Communication Adaptor Outdoor unit Group control Remote Controller Remote Controller Weekly Timer Group control 31