Contact person Date Reference Page Henrik Andersson F (4) Electronics

Similar documents
Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety

Contact person Date Reference Page Richard Johansson P (2) Fire Research

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008

CERTIFICATE of QUALITY TEST

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

EU-TYPE EXAMINATION CERTIFICATE

Contact person Date Reference Page Björn Folkeson P (15) Energy and bioeconomy

Contact person Date Reference Page Alen Rakovic P (19) Fire Research

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011

TEMPORARY IMMERSION AND DUST TEST REPORT

IMS INSTITUTE BELGRADE

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

TEST REPORT IEC60529 Edition TD990426C02

Contact person RISE Date Reference Page. Daniel Månsson P (13) Energy and circular economy

ENVIRONMENTAL TEST REPORT

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Contact person Date Reference Page Daniel Månsson P (13) Energy and circular economy

TEMPORARY IMMERSION AND DUST TEST REPORT

PQS Independent type-testing protocol

Environment Test Report

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

SPCR 183. RISE Research Institutes of Sweden AB Certification SPCR

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Additional deviations may possibly be found if a complete type test is carried out on the product.

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

PQS Independent type-testing protocol

Testing of dehumidifiers (1 appendix)

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

FLASHLIGHT ANSI STANDARDS

Independent, accredited testing station Member laboratory of STL and LOVAG

Edition 6, From serial no Publ. no Orwak 5030-CE. Operating manual

IECEx Certificate of Conformity

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK


OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 1: Electrical cone and piezocone penetration test

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Environmental testing Part 3-6: Supporting documentation and guidance Confirmation of the performance of temperature/humidity chambers

ISO CERTIFICATE nr/ no.5690 M. SP Sveriges Tekniska Forskningsinstitut

Certification Supplement Manual

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

SmartSensor 105 & Advance NEMA External Ice

Annubar Flowmeter Series

TEST REPORT. Junction Box (Dimension 123x78mm) MakelModel No. Raychem /- Serial No. l?qdcg/1641 Quantity/ No. of samples

INSTRUCTION MANUAL (ATEX / IECEx)

Standardization Programme ( ) Building & Construction Standards Committee

Accessories, interfaces, sensors and complete solutions.

Beck. The differential pressure transmitter for air

Economic and Social Council

Survey of electrical equipment installed in hazardous areas on tankers

CNBOP-PIB Standard Fire Protection

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30

A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism

INSTRUCTION MANUAL (ATEX / IECEx)

LOVAG TEST INSTRUCTION IEC/EN

This document is a preview generated by EVS

IECEx Certificate of Conformity

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Gas cylinder scale Model GCS-1

IECEx Certificate of Conformity

FLASHLIGHT ANSI STANDARDS

Fire Spread in Large Industrial Premises and Warehouses

INTERNATIONAL STANDARD

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

Exp, pressurized systems

PERFORMANCE REPORT. ARL Lab Number: Client: In-O-Vate Technologies Inc. 810 Saturn St. Jupiter, FL 33477

IECEx Certificate of Conformity

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

ISO 9001 CERTIFIKAT CERTIFICATE. nr/no Härmed intygas att:/this is to certify that:

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Certificate of constancy of performance

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

Type: Play house Length: 1195 mm Width: 1195 mm Height: 1740 mm Materials: 18,7 mm laminated wood

FALCON SERIES 12 METAL CLAD

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

The Hood Type Concept

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Portable central unit for several parameters

Transcription:

issued by an Accredited Testing Laboratory Contact person Henrik Andersson 2016-05-19 6F009034 1 (4) Electronics +46 10 516 55 74 henrik.andersson@sp.se Accred. No. 1002 Testing ISO/IEC 17025 ENOC SYSTEM AB Box 159 SE-334 23 Anderstorp Classification of degree of protection provided by enclosure (1 appendix) Test object One Fs1 cabinet. Electronics - Product Safety Performed by Examined by Signature_1 Henrik Andersson Signature_2 Anders Nilsson Postal address Office location Phone / Fax / E-mail Laboratories are accredited by the Swedish Board for Accreditation and SP Box 857 SE-501 15 BORÅS Sweden Västeråsen Brinellgatan 4 SE-504 62 BORÅS +46 10 516 50 00 +46 33 13 55 02 info@sp.se Conformity Assessment (SWEDAC) under the terms of Swedish legislation. This report may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Report format vers. 2015-03-27

2016-05-19 6F009034 2 (4) 1 Commission Classification of degree of protection provided by enclosure. Standard: IP-class: 2 Client EN 60529:1991 + A1:2000 + A2:2013. IEC 60529:1989 + A1:1999 + A2:2013. IP54, category 2 according to instructions given by the client. ENOC SYSTEM AB, Box 159, 334 23 Anderstorp, Sweden. 3 Test object One Fs1 cabinet. Dimensions 2000 mm x 800 mm x 800 mm (H x W x D). Refer to photographs in appendix 1. The test item was delivered to SP 2016-05-17. 4 Performance and result Testing was performed according to the specifications below. Standard: EN 60529:1991 + A1:2000 + A2:2013. IEC 60529:1989 + A1:1999 + A2:2013. IP-class: IP54, category 2. Method: SP-Method 1486:2015. Testing was carried by Henrik Andersson during the period from 2016-05-18 to 2016-05-19. The test results apply to the tested item only. 4.1 Atmospheric conditions Temperature: 20 C ± 1 C. Relative humidity: 35 % ± 5 %. Air pressure: 100 kpa ± 1 kpa. 4.2 General test conditions The tests were performed with the cabinet in its normal vertical position of use.

2016-05-19 6F009034 3 (4) 4.3 Test with probe (IP5X) The test was performed with a ø1 mm test probe pushed against the test item with a force of 1 N. Test equipment. Test probe: SP inventory No. 501890. Dynamometer: SP inventory No. 501913. Measuring uncertainty. Force: ± 0.11 N. 4.4 Dust test (IP5X) The test item was exposed to talcum powder in a dust chamber during 8 h. The amount of talcum powder was 2 kg per m 3 of the test chamber volume. Test equipment. Dust chamber. Stopwatch: SP inventory No. 501336. Measuring uncertainties. Time: ± 10 min. 4.5 Water spray test (IPX4) The test item was exposed to water spray from all directions during 7 min and 40 s (1 min/m 2 ), by means of a hand-held spray nozzle. The water flow was 10 l/min and the distance between the spray nozzle and the test item was 0.3 m-0.5 m. The temperature of the fresh water was 20 ºC. Test equipment. Spray nozzle: SP inventory No. 501250. Water flow meter: SP inventory No. 501880. Frequency counter: SP inventory No. 503436. Thermometer: SP inventory No. 502195. Stopwatch: SP inventory No. 501336. Measuring uncertainties. Water flow: ± 4.7 %. Time: ± 3.5 s.

2016-05-19 6F009034 4 (4) 4.6 Result The tested Fs1 cabinet fulfilled the IP54 category 2 requirements. The test probe did not penetrate the enclosure. No dust did penetrate the enclosure. No water did penetrate the enclosure. Appendix : Photographs

2016-05-19 6F009034 1 (5) Photographs Photograph 1: Fs1 cabinet

2016-05-19 6F009034 2 (5) Photograph 2: Fs1 cabinet

2016-05-19 6F009034 3 (5) Photograph 3: Fs1 cabinet, top Photograph 4: Fs1 cabinet, bottom

2016-05-19 6F009034 4 (5) Photograph 5: Fs1 cabinet, door opened

2016-05-19 6F009034 5 (5) Photograph 6: Fs1 cabinet, door opened