DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Similar documents
DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Concealed Ducted Split Series R-407C MBH

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units

EHH SERIES DRAW THROUGH FAN COILS CFM

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

PAJ3. Product Specifications

Advance Release September 2009

MAC N-407 Air-Cooled Chiller

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

CENTRAL SPLIT UNIT UNIC

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

SECTION WATER-SOURCE UNITARY HEAT PUMPS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Call us today! (800)

PACKAGE AIR CONDITIONER

AIR COOLED PACKAGED CHILLER

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

SKYPAK II, 3 Ton Series, gives you a

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Call us today! (800)

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Call us today! (800)

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MAC-120HE-03 Air-Cooled Chiller

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Product Specifications. Vertical Floor Consoles By First Co.

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

30GT FLOTRONIC AIR-COOLED CHILLERS

SKYPAK II, 3 Ton Series, gives you a

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

C13-Series Engineering Guide

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Construction Standards Page

YAH SERIES FAN COIL UNITS

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

CHAPTER 6 CONDENSING UNITS

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

30GN FLOTRONIC II AIR-COOLED CHILLERS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

.2 Section Waste Management and Disposal.

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

VertiCool Aurora Engineering Guide

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

VariCool VAV Engineering Guide

TABLE OF CONTENTS INTRODUCTION NOMENCLATURE AC P S J 035 C CO AR Q - 2 -

SKYPAK II Heating & Cooling Self Contained Packages

EMI ENGINEERING SUBMITTAL

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PAR5. Product Specifications

Air-Cooled Water Chiller Air-Cooled Water Chiller with Heat Pump Option 3~30 Tons

Centeral Station Air Handling Unit

Air-Cooled Condensing Units with Compact Screw Compressors

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Self-Contained Reverse Cycle Air Conditioners

Transcription:

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure Electrical control panel System protection Technical data Pages 6 to 7 R407C Extended capacity performance data Pages 8 to 13 Evaporator fan performance data Pages 14 to 16 Sound Data Page 17 Electrical Data Page 18 Units drawings and dimensions Pages 19 to 22 2

GENERAL FEATURES GAMI ducted split unit air conditioners are designed and manufactured with the following characteristics. Operating efficiently using environmental friendly R407C Operating up to 52 C ambient temperature due to efficient size of condenser coil. Easy monitoring and troubleshooting due to use of PLC control. Easy maintenance as access is provided for all the operating items. Easily accessible sight glass at the refrigeration circuits indicates the proper refrigerant charge and operation. Thermostatic expansion valve as standard for all the models,to ensure efficient operation even at variable load conditions. The evaporator fan motor and the pulleys are set for 125 pa external static pressure. Higher ESP s are also possible. (Consult the factory for details) FEATURES Operating at low noise and vibration level. Evaporator side has 10 mm thick,closed cell rubber type with aluminum foil insulation. Adjustable evaporator fan drive set for easy air flow adjustment. COMPONENTS FEATURES 1. COMPRESSORS The compressors are hermetic scroll. Scroll compressors have the following characteristics High efficiency Low sound levels. Limited wear due to few moving parts and suction gas motor cooling. Unique ability to handle liquid refrigerant in the suction line. 2. CONDENSERS The condensers are manufactured of plain seamless copper tubes 3/8 O.D mechanically bonded to corrugated aluminum fins to ensure optimum heat transfer. All the condensers are designed for the unit operation up to 52 C ambient temperature whereby the fin spacing selected (12 fpi) provides long life and maintenance free operation with the least possibility of operational blockage of the condenser. The coils are pressure leak tested by dry air pressure 35 bar(510 psig) under water. 3

FEATURES The condenser fans are axial type directly driven by external rotor motors. The motors are six pole, with class F insulation and IP 55 protection. 3. CONDENSER FANS The evaporator side of the unit is insulated with closed cell rubber type 10 mm thickness insulation. The structure permits easy access to all the working parts of the unit,so the maintenance of the unit is very easy. The combination of an external rotor motor and axial fan, on rubber isolators,with a properly dynamically balanced impeller,gives an efficient, quiet and reliable operation. The motors are factory wired to the control panel,to a separate contactor with overload for each fan. 4. EVAPORATORS The evaporators are manufactured of inner grooved seamless copper tubes 3/8 O.D mechanically bonded to louvered aluminum fins to ensure optimum heat transfer. 7. ELECTRICAL CONTROL PANEL The unit is controlled by a PLC (as optional) feature. The electrical panel enclosure is made from galvanized sheet metal electrostatic powder coated. The panel is located at the evaporator side of the unit and is being cooled by the unit cool air. Access to the panel can be made while the unit is working without any disturbance in the operation of the unit. Seamless copper tube suction headers and properly sized distributor at the refrigerant inlet along with the thermostatic expansion valve ensures smooth and reliable operation. All the evaporators are rated as per AHRI 410 standard. The coils are leak pressure tested by dry air pressure 35 bar(510 psi) under water. 5. EVAPORATOR FAN AND DRIVE The evaporator fan is forward curved centrifugal DIDW,statically and dynamically balanced,complete with shaft, self aligning and permanently lubricated ball bearings. The fan is driven by a single speed,4 pole,insulation class F and IP55 protection motor,rated for continuous operation at the rated conditions. The motor is factory wired to the control panel where a dedicated contactor is located, and is protected by an overload relay. The group of fan and motor is located on a rigid base which is isolated from the rest of the unit by rubber vibration isolators. 6. CASING/STRUCTURE. The unit casing is made of zinc coated galvanized steel sheets conforming to ASTM A653, electrostatic powder coated with approximate 75 microns coat,to ensure more than 1000 hours endurance at salt spray test as per ASTM B117. The drain pan of the unit is also manufactured with the same way as standard. 4

In the control panel the following are included. 8. SYSTEM PROTECTION Separate contactor with overload relay for each compressor. Separate contactor with overload relay for each condenser fan motor. Separate contactor with overload relay for the evaporator fan motor. PLC with backlit LCD screen for I/O status. (Optional feature) The safety features which are standard for our units and factory installed are: Low suction pressure switch High pressure switch Compressor (s) overload Condenser fan (s) overload Evaporator fan overload. FEATURES 24 V AC transformer to supply power to the PLC (Optional), the PLC inputs and the unit thermostat, with fuse protection. Phase loss and phase rotation protection device Phase loss in the power supply. All the above safety switches are controlled with the PLC (Standard feature) to ensure proper,reliable and safe operation of the unit. Power and control terminal blocks. Overcurrent protected main switch is field installed The control of the unit is made through external thermostat (optional) which provides the inputs to the PLC. The external thermostat should be powered by 24 V AC which should be taken from the unit and need to provide 24 V AC output for the system and the evaporator fan, which can operate in AUTO (controlled by the temperature) or ON (continuous on) mode Internal or duct heaters also can be controlled by the PLC (Optional) and the thermostat (consult the factory for details) NOMENCLATURE GCUN/GDS XX-D-T3-B x10 Nominal MBH C:COOLING 50 HZ D:COOLING 60 HZ T3 Climate specifications T3 (Tropical) A: REFRIGERANT R22 B: REFRIGERANT R407C 5

TECHNICAL DATA 6

TECHNICAL DATA 7

8

9

10

11

12

13

FAN PERFORMANCE DATA 14

FAN PERFORMANCE DATA 15

FAN PERFORMANCE DATA Data highlighted in grey are within the standard motor operating range, outside that area larger motor size to be used. 16

SOUND DATA 17

ELECTRICAL DATA 18

DRAWINGS-DIMENSIONS 19

DRAWINGS-DIMENSIONS 20

DRAWINGS-DIMENSIONS 21

DRAWINGS-DIMENSIONS 22

P.O. Box : 28131, ICAD-1, Mussafah, Abu Dhabi UAE Tel : +971-2-5506777 Fax : +971-2-5506622 E-mail: info@gami.ae Website: www.gami.ae Specifications in this catalogue are subject to change without notice in order that may bring latest innovations to the customers.