Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR

Similar documents
Instruction Manual April sitrans AS 100

Instruction Manual August sitrans CU 02

Quick Start Manual July pointek CLS100

CU-02 with Senaco Plus

Instruction Manual December 2001 ENACOCU02

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

multiranger 100 / 200

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Acoustic Sensors. Title page without bleed in RGB SITRANS AS100. Operating Instructions

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

PRODUCT CONFORMITY CERTIFICATE

Functional Safety Manual June pointek CLS500/LC500

PRODUCT CONFORMITY CERTIFICATE

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

POINTEK CLS 200 OINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E

Explosion Proof Line Powered Telephone Ringer

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

Fiber Optic Cable Fence Disturbance Sensor

Motion Sensors. Milltronics MFA 4p. Operating Instructions

G.O.L.D. GAS OPERATIONS LEAK DETECTION USER MANUAL

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

Isolated Thermocouple Module

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

CONTROL BE MADE CHANGES MAY NOT. Page 1

Installation and Operating Instructions

Eclipse 90 UV Scanner Model A Version 1

POINTEK CLS 300 OINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

Continuous level measurement Ultrasonic transmitters

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Level Measurement Continuous level measurement Ultrasonic transmitters

T7079A,B Solid State Remote Temperature Controllers

SITRANS. Temperature sensors SITRANS TSinsert/TS100/TS200/ TS500. Introduction 1. Safety information 2. Description 3. Installation 4.

Eclipse Self-Check UV Scanner

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Rosemount 3100 Series Ultrasonic Level Transmitters

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

EH3508/EH3512/ EH3515 Series Environmental Enclosure

Rosemount 3100 Series Ultrasonic Level Transmitters

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Installation Guide

A99B Series Temperature Sensors

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

OPERATION MANUAL Part No. MIL8001V4C

Certificate of Compliance

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Level Measurement Continuous level measurement - Ultrasonic transmitters

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Installation & Operation Manual

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Certificate of Compliance

CINEMA 500. Home theater speaker system QUICK-START GUIDE THANK YOU FOR CHOOSING THIS JBL PRODUCT INCLUDED ITEMS

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

Operating Instructions Edition 02/2007

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Installation Guide SmartRadar FlexLine

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

ENDURANCE Conductivity Sensors

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

DD205RF/TX Detector Installation Sheet

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

PoleStar Smart Refrigerated Air Dryers don t just cycle, cycle Smart.

Raychem Heating System

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

KM300 Carbon Monoxide Detection System Installation Manual

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

GAS MONITOR Model Model

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

The A-series Eletta Flow Monitor with local indication and analog output

Document No

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Certificate of Compliance

Hazardous Area Ringdown Telephone

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

Technical Manual. LeakFilm Sensor. Film Type Liquid Leak Detection Sensor

Transcription:

Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR

Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: The user is responsible for all changes and repairs made to the device by the user or the user s agent. All new components are to be provided by Siemens Milltronics Process Instruments Inc. Restrict repair to faulty components only. Do not reuse faulty components. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc. 2008. All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications European Authorized Representative at the following address: Technical Publications Siemens AG Siemens Milltronics Process Instruments Inc. Industry Sector 1954 Technology Drive, P.O. Box 4225 76181 Karlsruhe Peterborough, Ontario, Canada, K9J 7B1 Deutschland Email: techpubs.smpi@siemens.com For a selection of Siemens Milltronics level measurement manuals, go to: www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual archive listed under the product family. For a selection of Siemens Milltronics weighing manuals, go to: www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the manual archive listed under the product family. Siemens Milltronics Process Instruments Inc. 2008

Operation This product is intended for use in industrial areas. Operation of this equipment is a residential area may cause interference to several frequency based communications. The TS-2 Temperature sensor is used in conjunction with specified Siemens ultrasonic level measuring devices to monitor the temperature of the air between the transducer and the target surface. The TS-2 consists of a passive circuit which varies its resistance linearly with temperature. Thus it is used as the temperature input to the compensation circuitry of the associated Siemens transceiver. The resistance can be calculated by the following: R T = 127.096 T + 12175 ohms where : R = resistance in ohms T = temperature in C 7ML19985EW01 TS-2 Temperature Sensor INSTRUCTION MANUAL Page 1

Specifications Temperature Sensor Model: TS-2 Range: 40 to 70 C ( 40 to 158 F ) Construction: PVC body totally encapsulated Resistance 9.53 K. ( nominal ) at 20 C ( 68 F ) Separation equal to associated transducer separation Approvals CSA, FM and CE Shipping Weight 0.5 Kg ( 1 lb ) Accuracy +/- 1 C Page 2 TS-2 Temperature Sensor INSTRUCTION MANUAL 7ML19985WE01

Outline and Wiring cable terminal block in junction box black white black white Siemens transceiver shield shield extension cable 1 NPT 59 mm (2.31 ) Notes: 41 mm (1.63 ) 1. The temperature sensor should be mounted in a location which represents the temperature fluctuations likely to occur between the transducer and the target. 2. To avoid false readings, mount the temperature sensor out of direct sunlight. Radiant heating can cause a significant difference between air and sensor temperature. 3. Temperature sensor cable can be run with the transducer cable in a grounded metal conduit. Ground shield only at transceiver. Insulate shield at junctions to prevent inadvertent grounding. Extension cable: Belden 8760, 1 pair shielded / twisted, 18 AWG or equivalent. 4. Temperature sensor wiring must be done in conjunction with approved conduit, boxes and fittings and to procedures in accordance with all governing regulations. 5. For BASEEFA Zone 0, cable must be terminated externally to Zone 0 in an appropriate manner. The cable must be protected against mechanical damage, and arrangements sealed to prevent migration of atmosphere from Zone 0. 6. To reduce risk of electrostatic discharge, housing (except face) must be covered with copper mesh and grounded. 7ML19985EW01 TS-2 Temperature Sensor INSTRUCTION MANUAL Page 3

Typical TS-2 Installation transducer TS-2 Maximum material level 1. Temperature sensor should not cross sound beam of transducer. 2. Temperature sensor should not extend past maximum material level. Page 4 TS-2 Temperature Sensor INSTRUCTION MANUAL 7ML19985WE01

Typical Stilling Well Application blind flange air vent temperature sensor transducer standpipe primary measuring device stilling well standpipe inlet 7ML19985EW01 TS-2 Temperature Sensor INSTRUCTION MANUAL Page 5

Notes

Notes

Notes

www.siemens.com/processautomation Siemens Milltronics Process Instruments Inc. 1954Technology Drive, P.O. Box 4225 Peterborough, ON, Canada K9J 7B1 Tel: (705) 745-2431 Fax: (705) 741-0466 Email: techpubs.smpi@siemens.com Siemens Milltronics Process Instruments Inc. 2008 Subject to change without prior notice *7ml19985EW01* Printed in Canada Rev. 1.0